Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC SANAT NAGAR SRINAGAR PIN 190005 J K | SRINAGAR | JAMMU AND KASHMIR | 190005 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.6 L+₹16,619.50 (0.58%)Rejected-Finance KRAL PORA BAGH I MEHTAB NEAR MANCHOWA PETROL PUMP DISTRICT BUDGAM 190019 J K | BUDGAM | BUDGAM | J K | 190019 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹28.7 L+₹27,805.50 (0.98%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹29.1 L+₹66,762 (2.35%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹32.9 L+₹4.5 L (15.9%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | CHINAR CONSTRUCTION TRADERS L6 | M/S MARSHAL TRADERS L3 | M/S Inder Pal Singh L5 | M/S Razdan Buildersand suppliers L4 | M/S SA INFRATECH L7 | M/S RATHER CONSTRUCTION CO L2 | M/S BHAT ENGINEERING WORKS L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply , fabrication , errection testing and commissioning of raising and lowering type 16 mtr high galvanized mast suitable for 9 lanterns symmetricaly fitted along with their control gears Flag Mast Pole Top Diameter – 150 mm, Bottom Diameter – 360 mm Base Plate Pick Circle Diameter ( PCD ) 460 mm( Inner Diameter ) X 650 mm, Outer Diameter 750 mm , Base Plate thickness – 30 mm , service door size 300mmx540mm Auto timer control panel and having tow point suspension systems steel wire 6 mm dia double drum winch trailing cable (PCP EPR) galvanized lantern carriage arrangement suitable for mounting 9 luminaries symmetrically and lightening arrester S&F feeder pillar having ML-4 timer MCCB 63 Amp TP for automatic operation. Falg mast pole shaft thickness bottom 5mm, middle 4mm, Top 4mm and 1.5/2 HP 3 phase motor duoble drum heavy duty, 6mm S S wire rope x 3 Nos, incl Aviation light & dome The MAST shall have integral type power tool at the base compartment for its operation. mast shaft shall be in two section hold dip galvanized inside and outside in singel dip suitable for wind loading as per IS-875 part 3 including M&L for construction of suitable shalllow foundatioin for high MAST with M-20 grade concrete considering the safe soil bearing capacity at site as 10 Ton /Sqm at 2 mtr depth including provision of suitable size and number of foundation bolts alongwith nus, washer anchor plates and templates as per the drawing and specification of manufacture of high MAST system.
Note Aviation Obstruction light IP-65 10W-50W fix on same quoted rate. | 5 | Each | 5,00,000 ₹25,00,000 | 2,57,777 ₹12,88,885 Lowest | 4,20,000 ₹21,00,000 | 3,45,000 ₹17,25,000 | 5,95,000 ₹29,75,000 | 3,00,000 ₹15,00,000 | 3,14,900 ₹15,74,500 |
| 2.00 | S&F LED flood light 120 Watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP-65 protection, with impact and corrosion resistant complete with driver and lamp complete all as directed.. | 40 | Each | 4,500 ₹1,80,000 | 6,500 ₹2,60,000 | 9,000 ₹3,60,000 | 5,000 ₹2,00,000 | 3,907 ₹1,56,280 Lowest | 12,000 ₹4,80,000 | 3,950 ₹1,58,000 |
| 3.00 | Supply, installation, testing, commissioning outdoor type LT Panel board floor mounted, self supporting compartmentalised design of suitable size, 440V 3 phase 4 wire system powder coating provided with suitable to make it dust/vermin proof. The panel shall be made with 3.15 mm thick CRCA Sheet for outer shell and inner shell made out of 1.6mm thick CRCA Sheet, double door with front openable with locking arrangement, provision of threaded earthing stud at buttom, inner cell be compartmentalised, front openable single door system lockable. Inner shell completely vermin proof and to accomodate incoming/outgoing MCCBs, MCBs, and TPN aluminium bus and extension links. Copper bus bar of capacity 200A-03 Nos and 01 for neutral of capacity 100A duly insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size/ rating of eposy resin insulator all housed in suitable bus bar chamber. All control panel wiring shall be 4 sqmm multistranded copper conductor for power wiring between busbar to each incoming and outgoing MCCB/MCB with adequate size and shall be properly bunched/ tied, ferulled for proper identifiction and crimped with adequate size of lugs and provision and fixing of voltmeter, ammeter with built selector swith, CTs of suitable rating, led lamp all as specifed and directed with following (Onload changeover switch 100 amps-01,MCCB TPN 100 Amps,16 KA-01,MCCB TPN 63 Amps,16 KA-04) | 1 | Each | 60,000 ₹60,000 Lowest | 1,10,000 ₹1,10,000 | 1,30,000 ₹1,30,000 | 99,000 ₹99,000 | 70,000 ₹70,000 | 1,00,000 ₹1,00,000 | 95,000 ₹95,000 |
| 4.00 | Supply, installation, testing, commissioning out door type LT Panel board floor mounted, self supporting compartmentalised design of suitable size, 440V 3 phase 4 wire system powder coating provided with suitable to make it dust/vermin proof. The panel shall be made with 3.15 mm thick CRCA Sheet for outer shell and inner shell made out of 1.6mm thick CRCA Sheet, double door with front openable with locking arrangement, provision of threaded earthing stud at buttom, inner cell be compartmentalised, front openable single door system lockable. Inner shell completely vermin proof and to accomodate incoming/outgoing MCCBs, MCBs, Motor starters and TPN aluminium bus and extension links. Copper bus bar of capacity 200A-03 Nos and 01 for neutral of capacity 100A duly insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size/ rating of eposy resin insulator all housed in suitable bus bar chamber. All control panel wiring shall be 4 sqmm multistranded copper conductor for power wiring between busbar to each incoming and outgoing MCCB/MCB with adequate size and shall be properly bunched/ tied, ferulled for proper identifiction and crimped with adequate size of lugs and provision and fixing of voltmeter, ammeter with built selector swith, CTs of suitable rating, led lamp all as specifed and directed with following (MCCB TPN 63 Amps,16 KA-01,MCB TPN 32 Amps,6 KA-03,MCB SPN 16 Amps,6 KA-01, motor starter) | 5 | Each | 60,000 ₹3,00,000 | 1,30,000 ₹6,50,000 | 35,000 ₹1,75,000 Lowest | 90,000 ₹4,50,000 | 56,980 ₹2,84,900 | 70,000 ₹3,50,000 | 97,500 ₹4,87,500 |
| 5.00 | Supply and laying of XLPE insulated,sheathed,armoured,heavy duty LT 1100 volts grade cable 70 Sqmm 3.5core with aluminium conductor laid in trenches/pipes, fixed to poles/walls with suitable saddle complete all as directed. | 250 | RM | 550 ₹1,37,500 | 350 ₹87,500 Lowest | 570 ₹1,42,500 | 490 ₹1,22,500 | 908 ₹2,27,000 | 500 ₹1,25,000 | 550 ₹1,37,500 |
| 6.00 | Supply and laying of XLPE insulated,sheathed,armoured,heavy duty LT 1100 volts grade cable 25 Sqmm 3.5core with aluminium conductor laid in trenches/pipes, fixed to poles/walls with suitable saddle complete all as directed. | 450 | RM | 450 ₹2,02,500 | 300 ₹1,35,000 | 340 ₹1,53,000 | 230 ₹1,03,500 Lowest | 352 ₹1,58,400 | 250 ₹1,12,500 | 350 ₹1,57,500 |
| 7.00 | Supply and laying of XLPE insulated,sheathed,armoured,heavy duty LT 1100 volts grade cable 10 Sqmm 4 core with aluminium conductor laid in trenches/pipes, fixed to poles/walls with suitable saddle complete all as directed. | 350 | RM | 150 ₹52,500 | 200 ₹70,000 | 170 ₹59,500 | 140 ₹49,000 Lowest | 310 ₹1,08,500 | 200 ₹70,000 | 190 ₹66,500 |
| 8.00 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out | 146.25 | Cum | 150 ₹21,937.5 | 350 ₹51,187.5 | 200 ₹29,250 | 180 ₹26,325 | 90 ₹13,162.5 Lowest | 100 ₹14,625 | 250 ₹36,562.5 |
| 9.00 | M&L River sand cushioning to underground cables 8cm thick before laying cable and 15cm thick after laying and streching the cable, complete all as specified and directed by Engr-in-Charge. Note :- For payment purpose punned thickness shall be measured | 52.65 | Cum | 600 ₹31,590 | 1,200 ₹63,180 | 600 ₹31,590 | 700 ₹36,855 | 2,000 ₹1,05,300 | 500 ₹26,325 Lowest | 900 ₹47,385 |
| 10.00 | M/L for brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable complete all as specified and directed. | 5.2 | Per 1000 Nos | 4,000 ₹20,800 Lowest | 16,000 ₹83,200 | 8,000 ₹41,600 | 10,000 ₹52,000 | 9,768 ₹50,793.6 | 6,000 ₹31,200 | 4,500 ₹23,400 |
Tender Value
₹42.3 L
EMD Value
₹85,000
Closing Date
20 Dec 2025, 6:00 pmClosed
Lt Col Sanjay Siwach, GE
GE 970 EWS C/o 56 APO PIN-913970
PROVN OF 5 X HIGH MAST LIGHTS OF UNIT 14 WEU AT OLD AIR FIELD MIL STN UNDER GE 970 EWS
2025_MES_742214_1
GE970EWS-67(T)/2025-26
Open Tender
Civil Works
Item Rate
180 days
OLD AIR FIELD SRINAGAR
As per tender documents
8 documents required · 8 mandatory
₹500
GE 970 EWS
₹85,000
Yes
1 Mar 2026
29 Nov 2025
22 Dec 2025
29 Nov 2025
20 Dec 2025
15 Dec 2025
29 Nov 2025 - 20 Dec 2025
Supply , fabrication , errection testing and commissioning of raising and lowering type 16 mtr high galvanized mast suitable for 9 lanterns symmetricaly fitted along with their control gears Flag Mast Pole Top Diameter – 150 mm, Bottom Diameter – 360 mm Base Plate Pick Circle Diameter ( PCD ) 460 mm( Inner Diameter ) X 650 mm, Outer Diameter 750 mm , Base Plate thickness – 30 mm , service door size 300mmx540mm Auto timer control panel and having tow point suspension systems steel wire 6 mm dia double drum winch trailing cable (PCP EPR) galvanized lantern carriage arrangement suitable for mounting 9 luminaries symmetrically and lightening arrester S&F feeder pillar having ML-4 timer MCCB 63 Amp TP for automatic operation. Falg mast pole shaft thickness bottom 5mm, middle 4mm, Top 4mm and 1.5/2 HP 3 phase motor duoble drum heavy duty, 6mm S S wire rope x 3 Nos, incl Aviation light & dome The MAST shall have integral type power tool at the base compartment for its operation. mast shaft shall be in two section hold dip galvanized inside and outside in singel dip suitable for wind loading as per IS-875 part 3 including M&L for construction of suitable shalllow foundatioin for high MAST with M-20 grade concrete considering the safe soil bearing capacity at site as 10 Ton /Sqm at 2 mtr depth including provision of suitable size and number of foundation bolts alongwith nus, washer anchor plates and templates as per the drawing and specification of manufacture of high MAST system. Note Aviation Obstruction light IP-65 10W-50W fix on same quoted rate.
S&F LED flood light 120 Watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP-65 protection, with impact and corrosion resistant complete with driver and lamp complete all as directed..
Supply and laying of XLPE insulated,sheathed,armoured,heavy duty LT 1100 volts grade cable 70 Sqmm 3.5core with aluminium conductor laid in trenches/pipes, fixed to poles/walls with suitable saddle complete all as directed.
Supply and laying of XLPE insulated,sheathed,armoured,heavy duty LT 1100 volts grade cable 25 Sqmm 3.5core with aluminium conductor laid in trenches/pipes, fixed to poles/walls with suitable saddle complete all as directed.
Supply and laying of XLPE insulated,sheathed,armoured,heavy duty LT 1100 volts grade cable 10 Sqmm 4 core with aluminium conductor laid in trenches/pipes, fixed to poles/walls with suitable saddle complete all as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out
M&L River sand cushioning to underground cables 8cm thick before laying cable and 15cm thick after laying and streching the cable, complete all as specified and directed by Engr-in-Charge. Note :- For payment purpose punned thickness shall be measured
M/L for brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable complete all as specified and directed.
Returing filling in incl spreading leveling, watering and well ramming in layer not less than 25 cum each layer all as specified.
Removing excavated material/ surplus soil not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above the starting point.
M&L Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 metre below normal ground level with top edge of the earth plate not less 1.5 metre below normal ground level connected with and including GI strip of size 32x 6 MM by means of bolts and nuts check nut and washer of galvanized iron with & including PCC pit in PCC 1:2:4 type B-1, precast RCC cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 7.5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point, and testing on completion including taking down old unsv earthing, complete all as specified and directed. Note :- (i) RCC pit cover shall be pre cast of RCC (1:2::4) type B , 80 mm thick reinforcement with 8 mm TOR steel @ 100 c/c in lie if CI cover and the rate includes in the unit rate . (ii) Earth electrode shall be protected upto test point using necessary arrangement with suitable size GI pipe and the rate includes in the unit rate. (iii) Earth pit Cover shall be painted in Red paint over a primer and the rate included in the unit rate.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
Tender67T_merged.pdf
Tender Documents • 2.33 MB
BOQ_831119.xls
BOQ • 15.86 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .