| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹24.5 L+₹79,900 (3.37%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹24.8 L+₹1.1 L (4.53%)Rejected-Finance 0 CIVIL LINES TETARI BAZAR TETARI BAZAR NAUGARH SIDDHARTHNAGAR UTTAR PRADESH 272207 | SIDDHARTH NAGAR | UTTAR PRADESH | 272207 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹24.9 L+₹1.2 L (5.17%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹25.0 L+₹1.3 L (5.54%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
9 Feb 2021, 6:00 pmClosed
Garrison Engineer (East) Allahabad
Stanley Road, Teliyarganj, Allahabad
Repair/ replacement of internal wiring, sub-main wiring, electrical fittings and fixtures of MD officers and JCO/OR Accn and repair of heating appliances at Varanasi Cantt Under GE (East) Allahabad
2021_MES_413661_1
8437/E8
Open Tender
Civil Works
Item Rate
270 days
Varanasi
As Per NIT
8 documents required · 8 mandatory
₹500
Yes
GE East Allahabad
₹50,000
Yes
19 Mar 2021
18 Jan 2021
15 Feb 2021
18 Jan 2021
9 Feb 2021
2 Feb 2021
19 Jan 2021 - 25 Jan 2021
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. to match with the existing, complete all as specified and directed.
Point wiring complete with 1.5 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn through in and including 20mm dia rigid PVC conduit medium grade and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, including provision of 1.00mm thick factory made pressed steel terminal box of required size, duly painted both inside and outside with two coat of black bituminous paint over a coat of red oxide primer, duly covered with 2.8mm thick prelaminated sheet cover of colour as approved and duly concealed in walls for housing switches, sockets, regulators etc., including 1.5sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for one light point controlled by one 5 Amp one-way switch, complete all as specified and directed. NOTE:- (i) The quoted rate shall deemed to include the cost of pressed steel terminal boxes, prelaminated sheet cover etc. (ii) Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing
All as per Sl. Item No. 2.00 here-in-before but for one fan point controlled one 5 Amp one-way switch
All as per Sl. Item No. 2.00 here-in-before but for one 3-pin socket oiutlet 5 Amp on same board alongwith other switches
All as per Sl. Item No. 2.00 here-in-before but for one 3-pin socket oiutlet 5 Amp on independent board
All as per Sl. Item No. 2.00 here-in-before but for one light point controlled by one 5 Amp two-way switch
All as per Sl. Item No. 2.00 here-in-before but for one bell point controlled by one 5 Amp bell push
Point wiring complete with 4.0 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn through in and including 20mm dia rigid PVC conduit medium grade and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, including provision of 1.00mm thick factory made pressed steel terminal box of required size, duly painted both inside and outside with two coat of black bituminous paint over a coat of red oxide primer, duly covered with 2.8mm thick prelaminated sheet cover of colour as approved and duly concealed in walls for housing switches, sockets, regulators etc., including 4.0 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for one 15 Amp socket outlet, complete all as specified and directed. NOTE:- (i) The quoted rate shall deemed to include the cost of pressed steel terminal boxes, prelaminated sheet cover etc. (ii) Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing
Fixing only light fittings retrieved from Sl. Item No. 1 here-in-before at the old or new locations as directed with and including provsiion of all fixing accessories, complete all as specified and directed.
Switch piano, flush type single pole, one-way 5 Amp, white or ivory colour, ISI marked, complete all as specified and directed.
Switch piano, flush type single pole, one-way 15 Amp, white or ivory colour, ISI marked, complete all as specified and directed.
Switch piano, flush type single pole, two-way 5 Amp, white or ivory colour, ISI marked, complete all as specified and directed.
Bell push, flush type single pole, one-way 5 Amp, white or ivory colour, ISI marked, complete all as specified and directed.
Socket outlet 2 in 1, 3 pin, 5A, flush type, ISI marked, complete all as specified and directed.
Socket outlet 2 in 1, 6 pin, 5 and 15 Amp, flush type, ISI marked, complete all as specified and directed.
Bell Multi Music type, 230 V, ISI marked, complete all as specified and directed.
Ceiling rose three terminal surface bakelite type AC 50 Hz 230V, complete all as specified and directed.
Modular mounting GI metal box, 6-module, flush type, complete all as specified and directed. MAKE:- Cat No. CB91106WM00 of L&T or techno-commercially equivalent model in Havells / Legrand
Modular mounting GI metal box, 8-module, flush type, complete all as specified and directed. MAKE:- Cat No. CB91208WM00 of L&T or techno-commercially equivalent model in Havells / Legrand
Modular mounting GI metal box, 12x16-module, flush type, complete all as specified and directed. MAKE:- Cat No. CB91112WM00 of L&T or techno-commercially equivalent model in Havells / Legrand
Modular mounting GI metal box, 3-module, flush type, complete all as specified and directed. MAKE:- Cat No. CB91103WM00 of L&T or techno-commercially equivalent model in Havells / Legrand
Modular mounting GI metal box, 1 & 2-module, flush type, complete all as specified and directed. MAKE:- Cat No. CB91102WM00 of L&T or techno-commercially equivalent model in Havells / Legrand
Modular cover plate with grid frames, 6-module, flush type, complete all as specified and directed. MAKE:- Cat No. CB91106WM00 of L&T or techno-commercially equivalent model in Havells / Legrand
Modular cover plate with grid frames, 8-module, flush type, complete all as specified and directed. MAKE:- Cat No. CB91208WM00 of L&T or techno-commercially equivalent model in Havells / Legrand
Modular cover plate with grid frames, 12x16-module, flush type, complete all as specified and directed. MAKE:- Cat No. CB91112WM00 of L&T or techno-commercially equivalent model in Havells / Legrand
Modular cover plate with grid frames, 3-module, flush type, complete all as specified and directed. MAKE:- Cat No. CB91103WM00 of L&T or techno-commercially equivalent model in Havells / Legrand
Modular cover plate with grid frames, 1 & 2-module, flush type, complete all as specified and directed. MAKE:- Cat No. CB91102WM00 of L&T or techno-commercially equivalent model in Havells / Legrand
Modular switch 6 Amp, one-way, one module, 240V, complete all as specified and directed. MAKE:- Havells / L&T / Legrand
Modular switch 6 Amp, two-way, one module, 240V, complete all as specified and directed. MAKE:- Havells / L&T / Legrand
Modular switch 16 Amp, one-way, one module, 240V, complete all as specified and directed. MAKE:- Havells / L&T / Legrand
Modular Bell push 6 Amp, one module, 240V, complete all as specified and directed. MAKE:- Havells / L&T / Legrand
Modular socket 3/5-pin, 6/16 Amp, universal, two module, 240V, complete all as specified and directed. MAKE:- Havells / L&T / Legrand
Modular Socket, 6A - 2/3 pin combined, two module, 240V, complete all as specified and directed. MAKE:- Havells / L&T / Legrand
Modular Fan step regulator, 120W, two module, 240V, fixed in repairs, complete all as specified and directed. MAKE:- Havells / L&T / Legrand
Modular blanking / dummy plate, one / two module, 240V, complete all as specified and directed. MAKE:- Havells / L&T / Legrand
MCB DB, double pole and neutral, double door 6-way sheet metal enclosure with category of protection IP-42, 240V, with tinned copper 200Amp rated bus bar suitable for MCBs, complete all as specified and directed. MAKE:- Legrand / Havells / L&T / ABB
MCB DB, double pole and neutral, double door 8-way sheet metal enclosure with category of protection IP-42, 240V, with tinned copper 200Amp rated bus bar suitable for MCBs, complete all as specified and directed. MAKE:- Legrand / Havells / L&T / ABB
MCB DB, double pole and neutral, double door 12-way sheet metal enclosure with category of protection IP-42, 240V, with tinned copper 200Amp rated bus bar suitable for MCBs, complete all as specified and directed. MAKE:- Legrand / Havells / L&T / ABB
Decorative ultra slim LED tube light batten fitting suitable for and including provision of high efficiency, energy efficient, retrofit LED tube rod 20W / 22W, 6500K environmental friendly, direct surface mounted including connecting up with three core white PVC insulated copper conductor cable of suitable size, fixed in repairs, complete all as specified and directed. MAKE:- Havells / Philips / Wipro / Surya
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20Amp 240V, fixed in repair, complete all as specified and directed. MAKE:- Legrand / Havells / L&T / ABB
Sub main wiring complete with 2 runs of 4 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of PVC casing / caping 25mm dia and connecting terminal ends to DB's including providing 1 run of 4 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down old sub main wiring of any type and any size and making good disturbed surfaces to match with existing, complete all as specified and directed. NOTE:- (i) Two runs of 4 sq.mm copper conductor, one run of 4 sq.mm copper earth continuity conductor and one run of PVC casing / caping shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Sub main wiring complete with 2 runs of 2.5 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of PVC casing / caping 25mm dia and connecting terminal ends to DB's including providing 1 run of 2.5 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down old sub main wiring of any type and any size and making good disturbed surfaces to match with existing, complete all as specified and directed. NOTE:- (i) Two runs of 2.5 sq.mm copper conductor, one run of 2.5 sq.mm copper earth continuity conductor and one run of PVC casing / caping shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Sub main wiring complete with 2 runs of 6 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of PVC casing / caping 32mm dia and connecting terminal ends to DB's including providing 1 run of 6 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down old sub main wiring of any type and any size and making good disturbed surfaces to match with existing, complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of PVC casing / caping shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Stepped type electronic fan regulator flush type duly fixed on the existing phenolic laminated sheet etc. as required, 240V, humming free, complete all as specified and directed. MAKE:- Havells / L&T / Legrand
Decorative wall mounting fixture, white, MS body, opal glass suitable for and including provision of 2x15W retrofit LED, complete all as specified and directed. MAKE:- Cat No. LHFHDAE2TL1W-15 of Havells or techno-commercially equivalent model in Philips / WIpro
Decorative wall mounting fixture in durable plastic body and designer mesh in gold fish colour suitable for and including provision of14W retrofit LED, complete all as specified and directed. MAKE:- Cat No. LHFOECE1TZ1B014 of Havells or techno-commercially equivalent model in Philips / WIpro
Decorative wall mounting LED bed side lamp 7/9W with cover plate and making electric connection, complete all as specified and directed. MAKE:- Philips / Havells / Surya / Bajaj
Taking out unserviceable bulding security light any type, provision of LED street light 25W, complete all as specified and directed. MAKE:- Havells / Philips / Bajaj
MCB SP 6 - 32 Amp, 240 Volt, 'B' curve, 10KA breaking capacity, fixed in repairs, complete all as specified and directed.
MCB SPN 40 Amp, 240 Volt, 'B' curve, 10KA breaking capacity, fixed in repairs, complete all as specified and directed.
MCB SPN 63 Amp, 240 Volt, 'B' curve, 10KA breaking capacity, fixed in repairs, complete all as specified and directed.
MCB TPN 63 Amp, 240 Volt, 'B' curve, 10KA breaking capacity, fixed in repairs, complete all as specified and directed.
LED decorative bollard light with opal diffurser and aluminium reflectors fittings, 9W, fixed in repairs, complete all as specified and directed. MAKE:- Cat No. LTGLCW9WLED of C&S or techno-commercially equivalent model in Philips / Bajaj
Earthing complete with GI earth plate electrode 600mm x 600mm x 6.3mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth lead of 4mm dia by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 20mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover (1:2:4) mix with 6mm dia nominal reinforcement @ 150mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, fixed in repairs, complete all as speciifed and as directed. NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (b) If earth resistance is not found satisfactory, till satisfactory test result comes, the same shall be redone by the contractor without any extra cost to department.
LED retrofit lamp, 9W, B-22 type with holder base with polycarbonate body, fixed in repairs, complete all as specified and directed. MAKE:- Philips / Bajaj / Wipro / Havells / Surya
Taking down / out damaged existing louver shutter of exhaust fan and supply & fixing factory fabricated louver shutter suitable for 230-300 mm sweep with MS frame and galvanised tinned sheet of thickness 1mm and fixing with anchor bolt or fastner grouting in walls including provision of two coat of synthetic enamel painting over a coat of red oxide primer including preparation of surfaces, complete all as specified and directed.
Taking down / out damaged existing louver shutter of exhaust fan and supply & fixing factory fabricated louver shutter suitable for 380-400 mm sweep with MS frame and galvanised tinned sheet of thickness 1mm and fixing with anchor bolt or fastner grouting in walls including provision of two coat of synthetic enamel painting over a coat of red oxide primer including preparation of surfaces, complete all as specified and directed.
Taking down / out damaged existing louver shutter of exhaust fan and supply & fixing factory fabricated louver shutter suitable for 450 mm sweep with MS frame and galvanised tinned sheet of thickness 1mm and fixing with anchor bolt or fastner grouting in walls including provision of two coat of synthetic enamel painting over a coat of red oxide primer including preparation of surfaces, complete all as specified and directed.
Taking down existing geyser of any capacity, any type after disconnecting all electric and water supply connection, removing the geyser to E&M store yard for opening and dismantling the complete geyser, cleaning all the serviceable parts thoroughly, including descaling the geyser completely, replacing the defective / wornout parts / materials, reassembling the geyser after testing for proper functioning, including transporting to original location and re-fixing the same in position, reconnecting the geyser with electric and water supply line and testing, complete all as specified and directed.. NOTES : The quoted shall deemed to be inclusive of every minor items i.e., nut, bolts, screws, lugs etc., which are faily required for the smooth functioning of geyser.
Fixing in repair at site (without taking down Geyser), heating element threaded / screwed / square / round / triangular or any other type 1500 W, with rubber seal thermostat two way, 230 V, AC, ISI marked of make as approved, complete all as specified and directed.
Fixing in repair at site (without taking down Geyser), heating element threaded / screwed / square / round / triangular or any other type 2000 W, with rubber seal thermostat two way, 230 V, AC, ISI marked of make as approved, complete all as specified and directed.
Fixing in repair at site (without taking down Geyser) heating element of ceramic / porcelain or any other type, 1500 W, 230 V, complete all as specified and directed.
Fixing in repair at site (without taking down Geyser) heating element of ceramic / porcelain or any other type, 2000 W, 230 V, complete all as specified and directed.
Fixing in repair at site (without taking down Geyser), thermostat auto cut suitable for 25 or 50 litre capacity of geyser, range 20 degree to 80 degree, ISI marked, complete all as specified and directed.
Fixing in repair Inner tank made of copper metal 0.6 mm thick suitable for 25 litre capacity Geyser, complete all as specified and directed. MAKE:- (of existing geyser) Bajaj / Recold
Fixing in repair Inner tank made of copper metal 0.6 mm thick suitable for 50 litre capacity Geyser, complete all as specified and directed. MAKE:- (of existing geyser) Bajaj / Recold
Fixing in repair syphon assembly suitable for 25 litre capacity Geyser, complete all as specified and directed.
Fixing in repair syphon assembly suitable for 50 litre capacity Geyser, complete all as specified and directed.
Fixing in repair aperture plate assembly suitable for 25 litre capacity Geyser, complete all as specified and directed.
Fixing in repair aperture plate assembly suitable for 50 litre capacity Geyser, complete all as specified and directed.
Fixing in repair non-return valve 15 mm dia of cast copper alloy, complete all as specified and directed.
Fixing in repair pressure release valve 15 mm dia of cast copper alloy, complete all as specified and directed.
Glass wool in layers in geysers of 25/50 litre capacity including taking out old damaged glass wool, complete all as specified and directed.
Fixing in repair at site (without taking down Geyser) indicator lamp assembly with bulb suitable for geysers, round or square type of approved make, complete all as specified and directed.
Fixing in repair drain plug, complete all as specified and directed.
Fixing in repair PTMT float valve suitable for 15 mm dia galvanised iron pipe, complete all as specified and directed.
Flexible geyser connection pipe inliner EPDM and braided with 304 grade SS wire, 300mm long, suitable for 15mm dia pipe with chromium plated brass nipple / check nuts, heavy duty pressure grade and operating temprature upto 90 degree Centigrade, complete all as specified and directed.
Flexible geyser connection pipe inliner EPDM and braided with 304 grade SS wire, 450mm long, suitable for 15mm dia pipe with chromium plated brass nipple / check nuts, heavy duty pressure grade and operating temprature upto 90 degree Centigrade, complete all as specified and directed.
Flexible geyser connection pipe inliner EPDM and braided with 304 grade SS wire, 600mm long, suitable for 15mm dia pipe with chromium plated brass nipple / check nuts, heavy duty pressure grade and operating temprature upto 90 degree Centigrade, complete all as specified and directed.
Preparation of steel surfaces (of Geyser) of any description over 10cm width or girth and applying one coat painting, at site (without taking down Geyser of any type / capacity), by spray gun painting using synthetic enamel paint, re-writing or marking of MES Number with black colour, complete all as specified and directed.
PVC insulated aluminium conductor cable service wire, multi stranded of size 2-core, 10 sq.mm, complete all as specified and directed. MAKE:- KEI / Finolex / Plaza .
PVC insulated aluminium conductor cable service wire, multi stranded of size 2-core, 6 sq.mm, complete all as specified and directed. MAKE:- KEI / Finolex / Plaza .
LED post top lantern, 45W, aluminium die-cast body, suitable for fixing on 40mm / 50mm dia pipe, complete all as specified and directed. MAKE:- Surya / Philips / Havells
Fixing in repair building security light service bracket made out of 40mm dia medium grade GI pipe bend to shape required, including 2 No. heavy duty fixing clamp made out of not less than 3mm thick flat iron, including provision of nuts / bolts as requiredm, work shall be carried out at site, complete all as specified and directed.
Fixing in repair recess mounting 36W, 2' x 2' LED slim panel (595mm x 595mm), fittings including making connection with PVC insulated two core flexible copper conductor cable with connector block and making good the disturbed surfaces to match with the existing, complete all as specified and directed. MAKE:- Cat No. LTCRSLM36WATT2X2 of C&S or techno-commercially equivalent model in makes Philips / Wipro / Surya
Aesthetically desigend edgelit LED linear mirror light fittings 1x9W with high output PMMA diffuser for glare free light decorative, envoirement friendly, energy efficient, pre-wired and making necessary electric connections from ceiling rose with 23/.0076 flexible three core copper wire of length 1.20metre and fixed to wall firmly with and including provision of all fixsing accessories, complete all as specified and directed. MAKE:- Cat No. LHEXAPRP7PN1W009 of Havells or techno-commercially equivalent model in makes Crompton / Bajaj / Philips
Ultra slim edgelit LED down lighter, 7 W, high efficiency, glare free, powder coated aluminium housing, hanging on ceiling with steel chain, complete all as specified and directed. MAKE:- Philips / Havells / Crompton / Bajaj
Fixing in repair 18-20 W, four feet long, high efficiency, retrofit tube rod, suitable for fixing in existing fittings (existing fittings shall be of 36 Watt), complete all as specified and directed. MAKE:- Philips / Havells / Crompton / Bajaj / Surya/ Wipro
Lamp holder, insulated body with back plate suitable for batten fittings, complete all as specified and directed.
M/s A.K Construction
PANDEY TRADERS
M/s Rajeev Kumar
M/s A.KUMAR ELECTRICALS
H.B. Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .