| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC | L1 | Accepted-AOC Accepted due to lowest bidder | |
| 2 | L2₹26.2 L+₹2.2 L (8.98%)Rejected-Finance | L2 | Rejected-Finance Higher bidder | |
| 3 | L3₹27.1 L+₹3.1 L (12.8%)Rejected-Finance | L3 | Rejected-Finance Higher bidder | |
| 4 | L4₹27.6 L+₹3.6 L (14.8%)Rejected-Finance | L4 | Rejected-Finance Higher bidder | |
| 5 | L5₹27.7 L+₹3.7 L (15.4%)Rejected-Finance JOTANKUR TEGHORIJOTEVIRAM PURBA MEDINIPUR | MEDINIPUR EAST | WEST BENGAL | 721627 | L5 | Rejected-Finance Higher bidder |
Tender Value
₹28.2 L
EMD Value
₹56,400
Closing Date
8 Jun 2020, 6:00 pmClosed
CWE FEROZEPUR CANTT
HQ CWE FEROZEPUR CANTT
CWE/FZR-02/2020-21 SPECIAL REPAIRS TO BLDG NO P-7 OF OTM ACCN AT GRENADIERS BN UNDER GE (EAST) FEROZEPUR
2020_MES_337100_2
CWE/FZR-02/2020-21
Open Tender
Civil Works
Item Rate
180 days
FEROZEPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (EAST) FEROZEPUR CANTT
₹56,400
Yes
30 Jun 2020
27 May 2020
11 Jun 2020
27 May 2020
8 Jun 2020
3 Jun 2020
Amount
Dismantling of brick tiles single layer jointed & pointed in cement mortar including removal of grass vegetation, complete all as specified.
Demolition of mud phuska in roofs, any thickness, including leeping plaster (whether full thickness removed or only a part thereof) complete all as specified.
M&L for screed 10mm in cement mortar (1:4) on brick/concrete surfaces of roof, mixed with WPC (WPC shall be measured and paid seaparately), etc complete all as specified.
S&F 150 micron thick (transparent) polythene film with 150mm end & side laps, laid over a coat of bitumen primer @ 0.30 kg to 0.50 kg per sqm, bonded with a coat of 80/100 industrial bitumen @ 1.20 Kg/sqm and laid on roof, complete all as specified.
M&L 80 mm thick average, consolidated thickness, mud phuska on flat roofs,including 25 mm thick mud plaster and 3 mm thick leeping plaster, complete all as specified.
S&F 40 mm thick brick tiles laid over a layer of 25mm thick mud mortar and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement, complete all as specified.
All as per item No 6 herein before but using old brick tiles retrieved from dismantling (Item No 1 hereinbefore) including cleaning and removal of mortar from tiles, complete all as specified.
M&L Cement concrete (1:2:4) type B-0 (12.5 mm graded stone aggregate) as in kerbs, mud stops, round or chamfered on edges etc including form work, weathering, slightly rounded or chamfered complete all as specified.
M&L for Cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregate as in 50mm thick plinth protection, surfaces finished even and fair without using extra cement, including provision of construction joints filled with bitumen and sand mix compound complete all as specified.
Demolition of reinforced cement concrete in any position, complete all as specified.
M&L for reinforced cement concrete (1:1.5:3) type A-1 (20 mm graded stone aggregate) as in slab supported on walls, beams, roofs, landing balconies, canopies, deck slabs and in shelves and like complete all as specified.
M&L for use & waste wooden form work (rough finished surfaces ) to sides & soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports overhangs, etc also splays between floors and beams, floor/roof slab, landings and similar work n. exc 200mm thick, complete all as specified
Demolition of brick work built in cement mortar of any specification and in any position complete all as specified.
M&L for Brick work in cement mortar 1:6 using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6 metre mean radius, complete all as specified.
All as per item 14 hereinbefore but using old bricks retrieved from demolition under item 13 hereinbefore including cleaning and removal of mortar from old bricks complete all as specified.
M&L for Brick work in cement mortar 1:4 using sub class ‘B’ old size bricks in half brick thick walls, straight or curved on plan exceeding 6 metre mean radius complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified.
M&L for (table dressed and pre-polished) green marble slab, 16 mm thick of size not less than 1.00 square metre each, as in cooking platforms, steps, jambs, pillars, window cills and like, set and bedded in grey cement slurry over & including 20 mm thick screed in cement mortar (1:4) and pointed in white cement (1:2) with admixture of pigment to match the shade of marble (mirror type polished) complete all as specified.
M&L for Glazed ceramic tiles, coloured, of size 300x200x7mm to 8mm thick on vertical surfaces such as in skirting/dado etc set and jointed in cement slurry and pointed in white cement with pigment to match the colour of tiles, laid over & including 10 mm thick rendering in cement mortar (1:4), complete all as specified.
M&L for Non skid Ceramic coloured (colour and shade as approved) tiles,any shape, 7mm to 8 mm thick area of each tile exc. 0.11 sqm and not exc 0.18 sqm as in flooring set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour of tiles laid over & including 15 mm thick screed in cement mortar (1:6), complete all as specified.
All as per Item No-20 hereinbefore but as on vertical surfaces skirting/dado over and including 10 mm thick rendering in cement mortar (1:4), complete all as specified.
S&F Mild steel TMT bars 10 mm dia and over cut to length, bent to shape required including cranking, bending spirally for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete, FE-500/550 confirming to IS-1786-1985 all as specified & directed.
M&L for Taking down wooden/steel chowkhats or frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 Square metre each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts,making good jambs with plaster in CM(1:4) to match with existing finish, complete all as specified.
All as per item No 23 herein before but size exceeding 1.5 Square metre and not exceeding 4 Square metre each, complete all as specified.
Taking down door shutter of any description, exc 1 Sqm but not exceeding 2 sqm each and refixing in the same opening after resecuring, or easing & adjusting,complete all as specified.
S&F Factory made solid PVC door frame (having density not less than 600 kg/cum) of size 50 mm x 47 mm made of 5 mm plain colour PVC sheet reinforced with mild steel square tube, complete all as specified in MES Schedule Part-I (2009),including making good jambs in CM(1:4) with finishes to match with existing, complete all as per specification & shown in drawing.
S&F Factory made solid panel PVC door shutter 30 mm thick (having density not less than 600 kg/cum) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site, complete all as per specification in MES Schedule Part-I (2009) & shown in drawing.
S&F Factory made pressed steel frames made of 1.25 mm thick MS sheet of profile 125 mm X 60 mm for door and window frames with one or more rebates including lock strike plate, shock absorber, 20 mm dia 60 mm long MS conduit for housing of a drop bolt,hinges, hold fasts/lugs etc, treating of internal surfaces of chowkhats with coal tar or black paint including hold fasts/lugs etc complete all as specified.
S&F Factory made pressed steel frames made of 1.25 mm thick MS sheet of profile 105 mm X 60 mm for door and window frames with one or more rebates including lock strike plate, shock absorber, 20 mm dia 60 mm long MS conduit for housing of a drop bolt,hinges, hold fasts/lugs etc, treating of internal surfaces of chowkhats with coal tar or black paint including hold fasts/lugs etc complete all as specified.
M&L Cement concrete (1:3:6) type C-1 (20 mm graded stone aggregate) as in filling of steel chowkhats and bed blocks of hold fast including necessary formwork, complete all as specified.
S&F Factory made 35 mm thick,2nd class hard wood (Hollock), glazed and skeleton shutters open rebated and prepared to receive glass/ gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass/gauge etc for doors, size of members as specified in clause 8.24 (a) of MES Schedule Part-I (2009) Section-8, complete all as specified.
S&F Factory made, 35mm thick, 2nd class hard wood (Hollock), plain framed, panelled shutters, any number of panels, panels shall be of 9 mm thick B.W.P. commercial ply or 12mm thick BWR grade veneered particle board medium density, wood particle board with commercial face veneers, size of members as specified in clause 8.24(a) of MES Schedule Part-I (2009) section-8 complete all as specified.
M&L Factory made box type side hung steel window with pintal hinges & 2 Nos 150 mm mild steel tower bolts to each shutter, steel handle and with glazing bars dovetailed or welded and treated with one shop coat of zinc chromate primer complete all as specified and shown on Drawing No CEJZ/TD-06/07 & CEJZ/TD-07/07.
S&F Factory made box type side hung steel window with pintal hinges & 2 Nos 150 mm mild steel tower bolts to each shutter, steel handle and without glazing bars dovetailed or welded and treated with one shop coat of zinc chromate primer complete all as specified and shown on Drawing No CEJZ/TD-06/07 & CEJZ/TD-07/07.
S&F Factory made box type steel ventilator side/top hung with glazing bars dovetailed or welded and treated with one shop coat of zinc chromate primer complete all as specified and shown on Drawing No CEJZ/TD-06/07 & CEJZ/TD-07/07.
S&F Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work, complete all as specified.
S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture not more than 1.18mm and fixed with tinned tacks or galvanized wire staples, complete all as specified .
S&F 3mm thick, plain sheet glass ordinary quality and glazing, with oil putty or with wooden beads (supplied alongwith shutters), in squares n.exc 0.50 Sqm complete all as specified.
S&F extruded aluminium alloy butt hinge, 100mm long, with galvanized mild steel hinges pin anodised type B-21, complete all as specified.
S&F aluminium anodized barrel tower bolts, stove enameled black, with bright bolt, 200 mm long and fixed with steel screws, complete all as specified.
S&F Aluminium bow handle, aluminium anodized, 125 mm long and fixed with steel screws complete all as specified.
S&F 300 mm long aluminium anodized, sliding door bolt, plate type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts,four on bolts plate and two on staple plate, complete all as specified.
S&F in repair 300 mm mild steel helical door spring including roller and roller plate complete all as specified.
Taking up or down existing steel water tubing, 15 mm bore alongwith connections fixed/laid in any situation, complete all as specified
Taking up or down existing steel water tubing, 20 mm bore alongwith connections fixed/laid in any situation, complete all as specified.
S&F Galvanised iron steel water tubing, 15mm bore, medium grade with all fittings and fixed to walls and ceiling, complete all as specified.
S&F Galvanised iron steel water tubing, 20mm bore, medium grade with all fittings and fixed to walls and ceilings,complete all as specified.
Re-Fixing only, after cleaning old steel water tubing, 15mm bore and connections in new or old position using new fittings fixing to wall/ceiling or laid in floors complete all as specified.
Re-Fixing only, after cleaning old steel water tubing, 20mm bore and connections in new or old position using new fittings complete all as specified.
S&F in repair Cast iron floor trap for 75 mm bore pipe with cast iron grating including jointing to waste pipe in run lead, complete all as specified.
S&F 100mm cast iron sanitary connection socket to fit WC out-let, complete all as specified.
S&F lead joints to cast iron pipes and fitting in liue of cement joints, complete all as specified.
S&F in repair 100mm cast iron bossed pipe basin and bath connector, single (for one pipe system) complete all as specified.
Demolition and breaking up of 100 mm drain pipes (PVC/AC) set in cement mortar, complete all as specified.
S&F 100mm bore cast iron soil, waste and vent pipe, sand cast, in any length with or without ears with cement joints laid in trenches or in floor, complete all as specified.
S&F 100 mm dia cast iron soil, waste and vent pipe, sand cast, in any length with or without ears with cement joints fixed to walls with and including suitable clamps, complete all as specified.
S&F 75mm bore cast iron soil, waste and vent pipe, sand cast, in any length with or without ears with cement joints laid in trenches or in floor, complete all as specified.
S&F 75 mm dia cast iron soil, waste and vent pipe, sand cast, in any length with or without ears with cement joints fixed to walls with and including suitable clamps, complete all as specified.
S&F 50 mm dia cast iron soil, waste and vent pipe, sand cast, in any length with or without ears with cement joints fixed to walls with and including suitable clamps, complete all as specified.
S&F in repair 100 mm bore, cast iron bend (any radius), diminishing pieces or tapers (larger bore measured) with cement joints complete all as specified.
All as per item No 60 herein before but with oval access, complete all as specified.
S&F in repairs 100mm branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, complete all as specified.
S&F in repairs 75mm branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, complete all as specified.
S&F in repairs 100 mm Swan necks (or off- sets) upto 152 mm projection or inverted (spigot or socket type) or with parallel branches, complete all as specified.
S&F Mild steel curtain rod 20mm dia PVC powder coated with fixing side brackets, end cups, rings @ 10 Nos per RM and fixed with PVC rawl plugs & steel screws as in repairs complete all as specified.
S&F in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified.
S&F in repair 15mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified.
S&F in repair 1000 litres capacity rotational moulded, triple layer polythene water storage tanks PVC (cylindrical vertical with closed top) hoisting and fixed in position on roofs including fittings, complete all as specified.
S&F in repair 20mm bore PVC ball valve high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule, complete all as specified.
S&F in repair 15mm bore PVC ball valve high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule, complete all as specified.
S&F in repair 15mm stop cock cast copper alloy with crutch or butterfly handle ,screwed down screwed for iron pipe or for brass ferrule with fancy shank and cup (concealed type),complete all as specified.
S&F in repair 15 mm bore bib tap of, cast copper alloy screwed down, high pressure with crutch or butter fly handle, complete all as specified.
S&F in repair 15mm bore pillar tap, cast copper alloy with capstan heads, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified.
S&F in repair Vitreous china white squatting pan orissa pattern of size 580mm x 440mm with integral foot rests including necessary lime concrete and 100 mm bore cast iron ‘P’ trap with 550 to 600 mm long neck for connecting WC to branch piece with cement joints, complete all as specified.
S&F Low density polythene pipe (LDPE) of pressure rating 6 Kg per Sq.cm, 450mm long, heavy duty with two sets of brass nuts & washers (one at each end) etc suitable for 15mm bore of pipe, complete all as specified.
S&F Soap Dish stainless steel of any type directed, having thickness not less than 1mm, fixed to walls with chromium plated brass screws and wooden/plastic cleats, complete all as specified.
S&F in repairs Wash hand basin, flat back 550mmx400mm vitreous china (white) including PTMT waste coupling/fittings, 32mm bore size, waste pipe, PVC, 32mm bore, angle iron/cast iron brackets of required size as directed & making good disturbed surfaces to match with the existing, complete all as specified.
S&F in repairs PVC syphonic action type low level flushing cistern (white) of 10 liters capacity with inlet ball float valve, 32 mm PVC flush pipe and necessary fixing arrangements and connecting to water pipe, complete all as specified .
S&F in repair 15mm stop valve cast copper alloy with crutch or butterfly handle ,screwed down screwed for iron pipe or for brass ferrule fancy type chromium plated with fancy type shank and cup, complete all as specified.
S&F in repair 15mm stop cock cast copper alloy with crutch or butterfly handle, screwed down screwed for iron pipe or for brass ferrule fancy type chromium plated with long shank and cup (concealed type), complete all as specified.
S&F in repair, PTMT shower roses swivel type 125mm size (Minimum Wt 40 Grms) with or without joints, including fixing to steel pipe or union, complete all as specified.
S&F in repair Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms), complete all as specified.
S&F in repair, 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls including distance pieces and including stack clamps with nuts & bolts, complete all as specified.
All as per item No 84 hereinbefore but except pipe fixed to walls including distance pieces and including stack clamps with nuts & bolts, complete all as specified.
S&F 110 mm bore PVC (SWR) bends/shoe and provided with access door any radius fixed to walls including distance pieces and stack clamps, including making good around complete all as specified.
M&L for Jointing only 100 mm cast iron pipes and fittings or AC pipes and fittings, in repairs, with cement joints, complete all as specified.
M&L for Jointing only 75 mm cast iron pipes and fittings or AC pipes and fittings, in repairs, with cement joints, complete all as specified.
M&L for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified.
S&F 110mm bore, PVC (SWR) branch piece, single (single Y) equal or unequal and making good, complete all as specified.
S&F 110mm bore, PVC (SWR) junction, single (single Y) equal or unequal and making good, complete all as specified.
S&F, 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls as in rain water pipe, including distance pieces and incld stack clamps with nuts & bolts, complete all as specified.
M&L Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified.
M&L Preparation of new wooden or wood based surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified.
M&L Preparation of old treated steel surfaces of any description, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified.
M&L Preparation of old treated wooden surfaces of any description, over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified.
Taking down cement plaster from brick walls of any description, racking out joints, hacking for key, scrubbing down with water etc, complete all as specified.
M&L for Rendering 10 mm thick in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement, complete all as specified.
M&L for Rendering 15 mm thick in cement mortar (1:4) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement, complete all as specified.
M&L for Rendering 5 mm thick in cement mortar (1:3) on ceiling concrete surfaces finished even and smooth without using extra cement, complete all as specified.
M&L Preparation of old decorated plastered or unplastered surfaces by brooming down with steel wire brush, scraping down smoke soot, mould, moss and efflorescent salts and trading oil, greasy spots and applying two coats of oil bound distemper over a coat of wall care putty, complete all as specified and as directed.
M&L for Preparation of newly plastered surfaces and applying two coats of oil bound distemper over of chalk whitening, complete all as specified and as directed.
M&L Preparation of newly plastered surfaces of walls & applying three coats of white wash, complete all as specified.
M&L Preparation of old decorated plastered or unplastered surfaces by brooming down with steel wire brush, scraping down smoke soot, mould, moss and efflorescent salts and trading oil, greasy spots and applying one coat of white wash on walls including cornices, pillasters etc, complete all as specified and as directed.
M&L for Preparation of newly plastered surfaces of ceiling & applying three coats of white wash, complete all as specified.
M&L Preparation of old decorated plastered or unplastered by brooming down with steel wire brush, scarping down smoke soot, mould,moss and efflorescent salts and trading oil, greasy spots and applying two coat of white wash on ceiling including cornices, pillasters etc, complete all as specified and as directed.
M&L Preparation of new plastered surfaces walls etc and applying two coats of cement base paint over a coat of primer complete all as specified.
M&L Preparation of old plastered surfaces of walls after complete removal of existing treatment and applying two coats of cement base paint complete all as specified.
S&F in repair Vitreous China (white) flat back urinal, size of 465 x 355 x 265 mm (minimum), with grating and union for discharge pipe,sprinkler glass bulb type 68 degree temperature rating pendent type, PVC waste pipe upto floor trap,flush pipe,union for discharge pipe complete all as specified.
M&L for Kota stone slabs, 20mm thick, machine cut as in flooring of size not less than 0.25 Square metre each, set and jointed in cement slurry and pointed in cement mixed with pigment to match the shade of slab laid over & including screed bed of 20 mm thick in cement mortar (1:6) including rubbing, cutting and polishing (mirror type), complete all as specified.
S&F Kota stone slabs, 20 mm thick, machine cut as in shelf, skirting, steps, dado, pillars etc, set and jointed in cement slurry and pointed in cement mixed with pigment to match the shade of slab laid over & including rendering coat of 10 mm thick in cement mortar (1:3) including rubbing, cutting and polishing ,complete all as specified.
M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations, complete all as specified.
M&L for Rendering 10 mm thick in cement mortar (1:3) on any face of brick walls or concrete surfaces of sunken floor and applying hot bitumen blown any grade, applied hot, two coats, to concrete surfaces at the rate of 1.5kg. per sq. m per coat, complete all as specified.
M&L for Cutting chases, pinning in brick walls making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sun shades, shelves, lintels, etc.; and cutting chases for concealed water tubing and making good, cutting not exc 10 cm girth, complete all as specified.
All as per item 114 above, but exc 10cm girth and n.exc 20cm, complete all as specified.
M & L cement conceret (1:5:10) type E-2 40mm graded aggregate in foundations, fillings and mass concrete, complete all as specified.
M&L for water proofing treatment for RCC sunken portion by laying APP based polymeric membrane 4 mm thick with minimum weight not less than 4 kg/sqm , reinforced with non woven polyster fabric (wt. not less than 160 gms/sqm) torching Joints/overlaps with a propane or a butane gas torch, laid with a minimum overlap of 150mm with thermo fusable finish laid /bonded over a coat of hot blown bitumen 85/25 @ 1.20kg/sqm, over forced application bitumen primer @ 0.40 liters per sqm, including preparation of plastered surfaces of sunken floor ,complete all as specified and as directed by Engineer -in -Charge. NOTE :- The water proofing treatment shall be got carried out by manufacturer or their authorised applicator.
Taking down carefully existing copper/alumimium point wiring for light/fan/socket out let points complete with fitting and fixtures, battens, wire etc and making good the disturbed surfaces of walls and ceilings, complete all as specified.
Taking down unserviceable main switches, electric metres and distribution boards single phase, complete all as specified.
Taking down carefully old unserviceable sub main wiring and making good disturbed sufaces and matching with existing complete all as directed and specified.
S&F Point wiring complete with 1100 volts grade PVC FRLS insulated unsheathed cable of copper conductor, multi stranded of size 1.5 Sqmm, single core, drawn through & including PVC rigid concealed conduit, medium grade of suitable size (not less than 20mm dia )duly ISI marked with all accessories such as bends, reducers, spacers, saddles, junction boxes, bakelite sheets, sizes for mounting switch/sockets, fan regulators etc complete with and including continuous earth wire of size 1.5 Sqmm, single core, PVC FRLS copper conductor, insulated, unsheathed,stranded (Green colour) connected to common earth dolly complete all as specified for following:- (a) One light/fan/bell/exhaust point controlled by one single pole one way switch.
(b) One 3 pin 5 Amp socket outlet point controlled by one switch on Independent board .
(c) One 3 pin 5 Amp socket outlet point controlled by one switch on same board.
All as per item 124 above, but one switch socket outlet multi purpose, 3 pin, 15 Amps, point to be controlled by one switch and wiring with 2.5 Sqmm PVC FRLS cable, insulated, stranded, unsheathed copper conductor on Independent board with continuous earth wire of size 2.5 sqmm, PVC copper conductor, insulated, unsheathed, stranded, complete all as specified.
All as per item 124 above, but one switch socket outlet multi purpose, 3 pin, 15 Amps, point to be controlled by one switch and wiring with 4 Sqmm PVC FRLS cable, insulated, stranded, unsheathed copper conductor on Independent board with continuous earth wire of size 4 sqmm, PVC copper conductor, insulated, unsheathed, stranded, complete all as specified.
S&F Switch, piano, flush type, single pole one way, 5 Amps, ISI marked,complete all as specified.
S&F Switch piano flush button type 15 Amps, single pole, one way,ISI marked, complete all as specified.
S&F Socket outlet,2 in 1, 5 pin, 5 Amp, piano flush type,ISI marked, complete all as specified.
S&F Socket outlet 2 in 1, 6 pin,5 Amp and 15 Amp, piano flush type, ISI marked, complete all as specified.
S&F Ceiling rose, surface type, backelite 65mmx50mm, 3 terminals complete all as specified.
S&F Lamp holder, insulated body, threaded dome pattern, suitable for bracket/batten fittings, complete all as specified.
S&F in repairs stepped type electronic fan regulator for ceiling fan 1200/1400mm size, 230 volts, 6 Amps, complete all as specified.
S&F in repair of regular batten for LED 18W indoor decorative batten with extruded aluminium housing & Opal diffuser IP-20 fixed to walls/ ceiling etc complete including LED tube 18 W, complete all as specified.
S&F LED bulb of 10 watts, complete all as specified.
S&F in repairs bldg security light LED fittings 25 watts complete with all accessories like lamp, bracket of not exc 1.2 metre 40 mm GI light grade tubing & bent at middle to shape by 120 degree from vertical du;ly painted with two coats of aluminium paint with mild steel clamps, nuts & bolts,sleek pressure die cast aluminium housing heat resistant glass IP-65 protection, cable insulated and PVC sheathed copper conductor multi stranded and connecting to conductor and testing, complete all as specified.
S&F in repairs Factory made sheet metal enclosures double door type made out of CRCA 1.2 mm thick M.S sheet,powder coated, TPN DB with 200 Amps rated bus bar, 8 way, FP-42 protection surface mounting, 415 volts, dust and vermin proof, suitable for incorporation of MCCBs duly concealed in wall, factory made,including making good disturbed surfaces with matching colour, complete all as specified.
S&F of MCCB Thermal based release adjustable type 4 pole 63 Amps 50 Hz 415 Volts with rupturing capacity 16 KA including testing, complete all as specified and as directed.
S&F in repairs Factory made sheet metal enclosures double door type made out of CRCA 1.2 mm thick M.S sheet,powder coated, SPN DB with 200 Amps rated bus bar, 8 way, FP-42 protection surface mounting, 240 volts, dust and vermin proof, suitable for incorporation of MCCBs duly concealled in wall, factory made,including making good disturbed surfaces with matching colour, complete all as specified.
S&F in repairs Factory made sheet metal enclosures double door type made out of CRCA 1.2 mm thick M.S sheet,powder coated, SPN DB with 200 Amps rated bus bar, 4 way, FP-42 protection surface mounting, 240 volts, dust and vermin proof, suitable for incorporation of MCCBs duly concealled in wall, factory made,including making good disturbed surfaces with matching colour, complete all as specified.
S&F in repairs MCB, SPN, 63 Amps, 240 volts 10KA duly ISI marked, complete all as specified.
S&F in repairs MCB, single pole, 240 Volt, 06 to 32 Amps, 10 KA complete all as specified.
S&F in repairs for sub main wiring with two single core PVC insulated unsheathed stranded copper conductor cable FRLS 2x10 Sqmm single core 650/1100 V, drawn through & including rigid PVC rigid conduit 25 mm dia including continuous earth wire of size 1x10 sqmm, PVC insulated and unsheathed cable copper stranded conductor (green colour), complete all as specified. NOTE:- Two runs of cable, 1 run of earth wire & one run of PVC conduit shall be measured as one length.
S&F in repairs for sub main wiring with two single core PVC insulated unsheathed stranded copper conductor cable FRLS 2x6 Sqmm single core 650/1100 V, drawn through & including rigid PVC non metallic concealed conduit 25 mm dia including continuous earth wire of size 1x6 sqmm, PVC insulated and unsheathed cable copper stranded conductor (green colour), complete all as specified. NOTE:- Two runs of cable, 1 run of earth wire & one run of PVC conduit shall be measured as one length.
S&F heavy duty, 900 RPM Exhaust fan AC single phase 230/240 Volts of 300mm sweep with louver plastic body, including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection, complete all as specified.
Cutting hole making good, the disturbed surface, grouting nuts & bolts for fixing of exhaust fans, complete all as specified.
Hanging only ceiling fan including taking down and connecting up including provision of cable from ceiling rose or connector to fan, complete all as specified.
M& L Earthing as in repairs complete, all as shown on electrical plate No 3 of MES schedule part-I, as in repairs and as specified including the following:- (i) Galvanised steel earth plate of size 60cmsx60cmsx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.50 metre below normal ground level.(ii) Earth plate surrounded by and packed with char-coal and common salt in alternative layers (n.exc 15cms each layer).(iii) 4 mm dia (8 SWG) G.I earth wire from earth plate to main switch board including necessary GI bolts, nuts check nuts, washers, thimbles etc.(iv) 15 mm bore light grade, GI pipe for protection to earth-strip.(v) 20mm bore, medium grade GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horizontally to the earth pit. (vi) 50mm thick pre-cast cover of cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate and MS angle iron 25x25x3mm frame including two coats of painting over a coat of red oxide to exposed steel surfaces.(vii) Excavation in soft/loose soil, returning filling & removal of surplus soil to a distance upto 50 metre as directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire, complete all as specified.
S&F as in repairs XLPE insulated, armoured,1100 volts grade, heavy duty cable of size 35 Sqmm nominal cross section, 4 core, flat or circular, PVC FRLS insulated aluminium conductor, served with inner sheathing of galvanized steel wire or tape and over-all PVC FRLS sheathed in service connections, laid in trenches, duct, through pipe, in floor, on pole including jointing and testing, complete all as specified .
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and not exc 10 Sqm on plan, for laying of cable and getting out,compete all as specified.
M&L Dry and clean fine sand for cable cushioning to underground cable protection, complete all as specified. (Excavation and earth work measured separately). Note- Punned down thickness shall be measured.
S&F in repair Cover to underground cable with one layer of bricks using sub class ‘B’ bricks (old size) laid flat across the cable complete all as specified. (Excavation and earth work measured separately.
Returning, filling in, earth including spreading, leveling watering and well ramming in layers each not exceeding 25cm thick each layer, complete all as specified.
Removal of surplus soil to a distance not exc 50 metre and depositing where directed at a level not exc. 1.5 metre above the starting point complete all as specified.
S&F Mild steel galvanised pipe, light grade, 50 mm nominal bore for passing of cable, fixed to poles/walls, laid under floor/road crossings, complete with and including clamps socket & elbow etc complete all as specified.
M/S Yashpaul Gulati
manoj and company
M/s Sanjiv Kumar
M/s S B Construction Company
M/s Mukand Lal Khanna
KAMALJIT SINGH CONTRACTOR
M/s Bansi Lal
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .