| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC | ₹1.7 Cr | L1 | Accepted-AOC ok |
| 2 | L2₹1.8 Cr+₹3.2 L (1.82%)Rejected-Finance 1849 JUGRAJPUR SACHENDI KANPUR KANPUR NAGAR UTTAR PRADESH 208023 UDYAM UP 43 0012110 | KANPUR NAGAR | UTTAR PRADESH | 208023 | ₹1.8 Cr+₹3.2 L (1.82%) | L2 | Rejected-Finance ok |
| 3 | L3₹1.8 Cr+₹4.0 L (2.31%)Rejected-Finance | ₹1.8 Cr+₹4.0 L (2.31%) | L3 | Rejected-Finance ok |
| 4 | L4₹1.7 Cr−₹8.9 L (5.12%)Rejected-Finance | ₹1.7 Cr−₹8.9 L (5.12%) | L4 | Rejected-Finance ok |
| 5 | L5₹2.1 Cr+₹36.9 L (21.1%)Rejected-Finance VPO BERLA TEHSIL AND DISTT CHARKHI DADRI HARYANA | CHARKI DADRI | HARYANA | 127022 | ₹2.1 Cr+₹36.9 L (21.1%) | L5 | Rejected-Finance ok |
Tender Value
₹2.4 Cr
EMD Value
₹4.8 L
Closing Date
2 Jun 2023, 12:00 pmClosed
SARWAN KUMAR
Hisar W.S. Divn. Hisar
Constructing Pump House for dewatering of flood water in fields of village Gurana and Dhad.
2023_HRY_283391_1
2023292A8650 4F7A 4592 B774 7FDBBFA19764109IRR
Open Tender
Civil Works
Works
365 days
DHAD DHANI MIRDAD GURANA
3 documents required · 3 mandatory
₹15,000
₹4.8 L
Yes
XEN HWS Div. Hisar
15 Jun 2023
19 May 2023
2 Jun 2023
19 May 2023
2 Jun 2023
19 May 2023
19 May 2023 - 19 May 2023
24 May 2023
Amount
Credit of old bricks @ Rs. 880/cum
Supply, erection, testing and commissioning of submersible motor pumping set non clog for sewerage having head 24.0 mtr as per the indicated requirements of discharge in 8500 LPM and power capacity in 75 BHP Make KSB, CRI, Kirlosker, crompton greeve, Lubi Aqua, Kishore, matter and Platt, Beacon Wier
Supply of fully autometic electric control panel board for tubewells or in pump chambers consisting of MS sheet of thickness 14 gauge dully painted box type floor mounted made of angle frame containing one no.. fully autometic air brake starter suitable for motor of the following capacity (min. switches of suitable range with HRC fuse, one no. volt meter, (0 to 500 Volt), one no. amp meter (0 to 10 amp) 3 set of indicative lambs capacitor of suitable capacity and 1 no. single phase prevent with the timer switch including wiring in panel board and suitable electirc energy meter wiring in electric control panel board complete i/c MCB suitable capacitor, wooden box etc. complete in all respect rates already approved vide CE/BWS No. 1591/5BWS/216/320 dated 11.03.2022
Recovery of old dismantled RCC NP-3 pipe
Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipe of PE-80 grade and PN- 4 for water supply as per IS 4984-2016 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment. 400 mm Outside Dia
Supply and laying of 100 micron polythene
Bidder Name
Amount
Ranjit Singh(GSTN-NA)
The Sandlana Adarsh Coop. Labour and Construction Society Ltd.(GSTN-NA)
M/s Balaji Construction Co.(GSTN-NA)
PREM KUMAR CONTRACTOR(GSTN-NA)
OM PARKASH CONT(GSTN-NA)
M/s Balaji Construction Co.
PREM KUMAR CONTRACTOR
Ranjit Singh
OM PARKASH CONT
PREM KUMAR CONTRACTOR
Ranjit Singh
The Sandlana Adarsh Coop. Labour and Construction Society Ltd.
OM PARKASH CONT
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .