Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC | ₹1.8 Cr | L1 | Accepted-AOC Negotiated the Lowest rate Quoted tenderer accepted |
| 2 | L2₹1.9 CrRejected-AOC | ₹1.9 Cr | L2 | Rejected-AOC Rate quoted Higher than L1 Bidder |
| 3 | L3₹1.9 CrRejected-AOC | ₹1.9 Cr | L3 | Rejected-AOC Rate quoted Higher than L1 Bidder |
| Sl No | Description | Qty | Unit | L RAMESH L3 | BHARATHI ENGINEERING AND ELECTRICAL CONTRACTORS L2 | sms elevator company L1 |
|---|---|---|---|---|---|---|
| 1.00 | Renewal by Design, engineering, supply, fabrication, erection, testing, commissioning and handing over of 26 persons capacity, 1768kg, bed Cum Passenger Lift with M/C room, Speed 1 m/s with Stainless Steel Panels, Disable friendly, microprocessor based controller & VVVF drive with enhanced ride comfort and leveling functions, Fire rated doors and ARD, single side entry, gearless Lift as per the relevant IS up to date amendments.
(Casualty Block - 1No, 300 Bedded Block - 1No)
1.No. of floors: Ground +3floor, 4 stops
2.Total Travel: 10.8 metres(Apprx.)
3.Levelling Accuracy: High level accuracy with smooth and jerk free stopping.
4.Construction of Car: High quality stainless steel car with Neat hair line finish vinyl floorin and false ceiling .
5Position of machine: Directly above the lift shaft. (Gearless)
6.No. of landing entrance: 4
7.No. of car entrance: one
8.Car entrance door: Power operated V3F drive Centre/Side opening sliding stainless steel scratch proof door with hair line finish.
9. Landing entrance door: Centr opening stainless steel door with hair line finish with provision for emergency key opening at all landings.
10.Lift well existing : 3000mm x 2400mm (As per IS 14665 Part 1 2000)
11. Lift pit depth 1600mm (as ptr IS M665)(part l) - 2000)
12.Car size: 1600mm (width) x 2400mm (Depth) as per IS 14665 (part I) - 2000)/ as per standards upto date.
13.Car clear opening: 1200 mm width x 2000mm height (as per IS 14665) (part l) - 2000) /as per standards upto date. | 2 | Nos | 38,15,000 ₹76.3 L | 37,27,500 ₹74.5 L | 36,40,000 ₹72.8 L |
| 1.0114.Power supply: 400/440 V, 3 phase, 50 Cycles/sec A.C. supply for power and 230 V, 50 HZ, single phase, AC supply for light. 15.Control: Micro Processor based simplex selective collective control with/without attendant. 16.Car fittings: LED (JLPL 77) & Regular (Circular)-Fan with comfortable ventilation inside the car. 17.Lift well: R.C.C. construction with brick masonry. 18.Indication: UP/Down digital direction and position indicator for all landing and in car. 19.Emergency Alarm Bell: Battery operated alarm bell to be provided with Automatic charging device. 20.Emergency light: Battery operated light to be provided with Automatic charging device. 21.Fire Man's switch: To be provided at ground floor. 22.Minor builders work: included in the 23.Scaffolding: Included in the scope 24.Sill angles and facia plates: included in the scope. 25.Steel for lift machinery: Included in the Scope. 26.Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by lift contractor during the guarantee period of one year. 27.Automatic Rescue device: To facilitate the landing of the lift to the nearest floor at the time of power failure. This shall consists of suitable type battery system with charger, invertor, under voltage protection system etc., complete with all accessories. | ||||||
| 1.0228.Intercom:To be provided by the lift contractor with in-built intercom (push type) in car panel and with provision of push type intercom in machine room and ground floo entrance. 29.Floor annunciator with music wit announcement in both Tamil and English. 30.Special features: a. Infra-red door sensor with full height c.Voltage stabilizer for circuit control. d.Stainless Steel signal fixtures. e.Vandal proof S.S. Button with S.S. cover f.SS door frames for landing doors. g.VF door operator. h.Call Register signal i.Stainless steel facia plate for car operating panel and landing fixtures. j.On - Off switch for fan and light k.Over load warning indicator awith. audio announcement 31.Other standard features: Over speed governor, phase failure and phase reversal relay alarm bell, T. Guide brackets for car and counter weight, rubber padding under winding unit, motor of adequate capacity, electro magnetic brake with compression springs car safety gears buffer, electro mechanical door locks emergency key side supporting angles, motor over load protection devices final limit switch main suspension ropes counter weights lifting joint joist for mounting the machineries. 32.Guarantee: Guarantee for the materials and workmanship of equipments complete should be offered by lift firm fora period of not less than one year. 33.Site testing in accordance with IS 14665 / standards upto date should be carried out at the time of handing over. 34. Supply of operation and maintenance manual with necessary tools for operation. | ||||||
| 1.0335.Lift licence: Preparation of drawing payment of charges to CEIG and insurance policies if any and obtaining CEIG safety certificate as per lift act should be done by lift contractor. | ||||||
| 2.00 | Renewal by Design, engineering, supply fabrication, erection, testing, commissioning and handing over of 13 persons capacity 884kg, Passenger Lift with M/C room, Speed 1.5 m/s with Stainless Steel Panels, Disable friendly, microprocessor based controller VVVF drive with enhanced ride comfort and leveling functions, Fire rated doors and ARD, single side entry, gearless Lift as per the relevant IS up to date amendments. (Faculty Block - 2 Nos) | 2 | Nos | 22,89,000 ₹45.8 L | 22,36,500 ₹44.7 L | 21,84,000 ₹43.7 L |
| 2.011.No. of floors: Ground +3floor, 4 stops 2.Total Travel: 10.8 metres(Apprx.) 3.Levelling Accuracy: High level accuracy with smooth and jerk free stopping. 4.Construction of Car: High quality stainless steel car with Neat hair line finish vinyl flooring and false ceiling. 5.Position of machine: Directly above the lift shaft. Gearless 6.No. of landing entrance: 4 7.No. of car entrance: one 8.Car entrance door: Power operated V3F frive Centre opening sliding stainless steel ;cratch proof door with hair line finish. 9.Landing entrance door: Centre opening stainless steel door with hair line finish with provision for emergency key opening at all landings. 10.Lift well existing : 2500mm x 1900mm (As IS 14665) (Part 1)- 2000) 11.Lift pit depth 1600mm (as per IS 14665) part l) - 2000) 12.Car size:2000mm (width) x 1100mm (Depth) as per IS 14665 (part l) - 2000)/ as per standards upto date. | ||||||
| 2.0213.Car clear opening: 900 mm width x 2000mm height (as per IS 14665) (part I) 2000) /as per standards upto date. 14.Power supply: 400/440 V, 3 phase, 50 Cycles/sec A.C. supply for power and 230 V 50 HZ, single phase, AC supply for light. 15.Control: Micro Processor based simplex selective collective control with/without attendant. 16.Car fittings: LED (JLPL 77) & Regular (Circular)-Fan with comfortable ventilation inside the car. 17.Lift well: R.C.C. construction with brick masonry. 18.Indication: UP/Down digital direction and position indicator for all landing and in car. 19.Emergency Alarm Bell: Battery operated alarm bell to be provided with Automatic charging device. 20.Emergency light: Battery operated light to be provided with Automatic charging device. 21.Fire Man's switch: To be provided at ground floor. 22.Minor builders work: included in the scope. 23.Scaffolding: Included in the scope 24.Sill angles and facia plates: included in the scope. 25.Steel for lift machinery: Included in the scope. 26.Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by lift contractor during the guarantee period of one year. | ||||||
| 2.0327.Automatic Rescue device: To facilitate the landing of the lift to the nearest 'floor' at the of power failure. This shall consists of suitable type battery system with charger, invertor, under voltage protection system etc., complete with all accessories. 28.Intercom:To be provided by the lift contractor with in-built intercom (push type) in car panel and with provision of push type intercom in machine room and ground floor entrance. 29.Floor annunciators with music with announcement in both Tamil and English. 30.Special features: a. Infra-red door sensor with 'full 'height screen c.Voltage stabilizer for circuit control. d.Stainless Steel signal fixtures. e.Vandal proof S.S. Button with S.S. cover f.SS door frames for landing doors. g.VF door operator. h.Call Register signal i.Stainless steel facia plate for car operating panel and landing fixtures. j.On - Off switch for fan and light k.Over load warning indicator with audio announcement | ||||||
| 2.0431.Other standard features: Over speed governor, phase failure and phase reversa relay alarm bell, T. Guide brackets for car and counter weight, rubber padding under winding unit, motor of adequate capacity, electro magnetic brake with compression springs car safety gears buffer, electro mechanical door locks emergency key side, supporting angles, motor over load protection devices final limit switch main suspension ropes bounter weights lifting joint joist for mounting the machineries. 32.Guarantee: Guarantee for the materials and workmanship of equipments complete should be offered by lift firm for a period o not less than one year. 33.Site testing in accordance with IS 14665 should be carried out at the time of handing over. 34.Supply of operation and maintenance manual with necessary tools for operation. 35.Lift licence : Preparation of drawing, payment of charges to CEIG and insurance policies if any and obtaining CEIG safety certificate as per lift act should be done by lift contractor. | ||||||
| 3.00 | Renewal by Design, engineering, supply, fabrication, erection, testing, commissioning and handing over of 10 persons capacity,680kg, Passenger Lift with M/C room, Speed 1.5 m/s with Stainless Steel Panels, Disable friendly, microprocessor based controller & VVVF drive with enhanced ride comfort and leveling functions, Fire rated ft)ors and ARD, single side entry, gearless Lift per the relevant IS up to date amendments. (Casualty Block - 1 No, 300 Bedded Block - 1No) | 2 | Nos. | 20,84,250 ₹41.7 L | 20,44,550 ₹40.9 L | 20,04,850 ₹40.1 L |
Tender Value
₹1.8 Cr
EMD Value
₹99,550
Closing Date
11 Feb 2026, 3:00 pmClosed
Superintending Engineer
Office of Superintending Engineer PWD Buildings construction and maintenance circle Madurai
Renewal of 2 Nos. of 26 Persons bed cum passenger lifts and each 2 Nos. of 10 and 13 Persons passenger lifts at Theni Government Medical College and Hospital in Theni District.
2026_PWD_648881_1
47SE/Bldgs C and M Circle Madurai 2025-26-4 dated 27.01.2026
Open Tender
Electrical Works
90 days
Medical College Hospital
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹99,550
18 May 2026
2 Feb 2026
11 Feb 2026
2 Feb 2026
11 Feb 2026
2 Feb 2026
Renewal by Design, engineering, supply, fabrication, erection, testing, commissioning and handing over of 26 persons capacity, 1768kg, bed Cum Passenger Lift with M/C room, Speed 1 m/s with Stainless Steel Panels, Disable friendly, microprocessor based controller & VVVF drive with enhanced ride comfort and leveling functions, Fire rated doors and ARD, single side entry, gearless Lift as per the relevant IS up to date amendments. (Casualty Block - 1No, 300 Bedded Block - 1No) 1.No. of floors: Ground +3floor, 4 stops 2.Total Travel: 10.8 metres(Apprx.) 3.Levelling Accuracy: High level accuracy with smooth and jerk free stopping. 4.Construction of Car: High quality stainless steel car with Neat hair line finish vinyl floorin and false ceiling . 5Position of machine: Directly above the lift shaft. (Gearless) 6.No. of landing entrance: 4 7.No. of car entrance: one 8.Car entrance door: Power operated V3F drive Centre/Side opening sliding stainless steel scratch proof door with hair line finish. 9. Landing entrance door: Centr opening stainless steel door with hair line finish with provision for emergency key opening at all landings. 10.Lift well existing : 3000mm x 2400mm (As per IS 14665 Part 1 2000) 11. Lift pit depth 1600mm (as ptr IS M665)(part l) - 2000) 12.Car size: 1600mm (width) x 2400mm (Depth) as per IS 14665 (part I) - 2000)/ as per standards upto date. 13.Car clear opening: 1200 mm width x 2000mm height (as per IS 14665) (part l) - 2000) /as per standards upto date.
28.Intercom:To be provided by the lift contractor with in-built intercom (push type) in car panel and with provision of push type intercom in machine room and ground floo entrance. 29.Floor annunciator with music wit announcement in both Tamil and English. 30.Special features: a. Infra-red door sensor with full height c.Voltage stabilizer for circuit control. d.Stainless Steel signal fixtures. e.Vandal proof S.S. Button with S.S. cover f.SS door frames for landing doors. g.VF door operator. h.Call Register signal i.Stainless steel facia plate for car operating panel and landing fixtures. j.On - Off switch for fan and light k.Over load warning indicator awith. audio announcement 31.Other standard features: Over speed governor, phase failure and phase reversal relay alarm bell, T. Guide brackets for car and counter weight, rubber padding under winding unit, motor of adequate capacity, electro magnetic brake with compression springs car safety gears buffer, electro mechanical door locks emergency key side supporting angles, motor over load protection devices final limit switch main suspension ropes counter weights lifting joint joist for mounting the machineries. 32.Guarantee: Guarantee for the materials and workmanship of equipments complete should be offered by lift firm fora period of not less than one year. 33.Site testing in accordance with IS 14665 / standards upto date should be carried out at the time of handing over. 34. Supply of operation and maintenance manual with necessary tools for operation.
35.Lift licence: Preparation of drawing payment of charges to CEIG and insurance policies if any and obtaining CEIG safety certificate as per lift act should be done by lift contractor.
Renewal by Design, engineering, supply fabrication, erection, testing, commissioning and handing over of 13 persons capacity 884kg, Passenger Lift with M/C room, Speed 1.5 m/s with Stainless Steel Panels, Disable friendly, microprocessor based controller VVVF drive with enhanced ride comfort and leveling functions, Fire rated doors and ARD, single side entry, gearless Lift as per the relevant IS up to date amendments. (Faculty Block - 2 Nos)
1.No. of floors: Ground +3floor, 4 stops 2.Total Travel: 10.8 metres(Apprx.) 3.Levelling Accuracy: High level accuracy with smooth and jerk free stopping. 4.Construction of Car: High quality stainless steel car with Neat hair line finish vinyl flooring and false ceiling. 5.Position of machine: Directly above the lift shaft. Gearless 6.No. of landing entrance: 4 7.No. of car entrance: one 8.Car entrance door: Power operated V3F frive Centre opening sliding stainless steel ;cratch proof door with hair line finish. 9.Landing entrance door: Centre opening stainless steel door with hair line finish with provision for emergency key opening at all landings. 10.Lift well existing : 2500mm x 1900mm (As IS 14665) (Part 1)- 2000) 11.Lift pit depth 1600mm (as per IS 14665) part l) - 2000) 12.Car size:2000mm (width) x 1100mm (Depth) as per IS 14665 (part l) - 2000)/ as per standards upto date.
27.Automatic Rescue device: To facilitate the landing of the lift to the nearest 'floor' at the of power failure. This shall consists of suitable type battery system with charger, invertor, under voltage protection system etc., complete with all accessories. 28.Intercom:To be provided by the lift contractor with in-built intercom (push type) in car panel and with provision of push type intercom in machine room and ground floor entrance. 29.Floor annunciators with music with announcement in both Tamil and English. 30.Special features: a. Infra-red door sensor with 'full 'height screen c.Voltage stabilizer for circuit control. d.Stainless Steel signal fixtures. e.Vandal proof S.S. Button with S.S. cover f.SS door frames for landing doors. g.VF door operator. h.Call Register signal i.Stainless steel facia plate for car operating panel and landing fixtures. j.On - Off switch for fan and light k.Over load warning indicator with audio announcement
31.Other standard features: Over speed governor, phase failure and phase reversa relay alarm bell, T. Guide brackets for car and counter weight, rubber padding under winding unit, motor of adequate capacity, electro magnetic brake with compression springs car safety gears buffer, electro mechanical door locks emergency key side, supporting angles, motor over load protection devices final limit switch main suspension ropes bounter weights lifting joint joist for mounting the machineries. 32.Guarantee: Guarantee for the materials and workmanship of equipments complete should be offered by lift firm for a period o not less than one year. 33.Site testing in accordance with IS 14665 should be carried out at the time of handing over. 34.Supply of operation and maintenance manual with necessary tools for operation. 35.Lift licence : Preparation of drawing, payment of charges to CEIG and insurance policies if any and obtaining CEIG safety certificate as per lift act should be done by lift contractor.
Renewal by Design, engineering, supply, fabrication, erection, testing, commissioning and handing over of 10 persons capacity,680kg, Passenger Lift with M/C room, Speed 1.5 m/s with Stainless Steel Panels, Disable friendly, microprocessor based controller & VVVF drive with enhanced ride comfort and leveling functions, Fire rated ft)ors and ARD, single side entry, gearless Lift per the relevant IS up to date amendments. (Casualty Block - 1 No, 300 Bedded Block - 1No)
1.No. of floors: Ground +3floor, 4 stops 2.Total Travel: 10.8 metres(Apprx.) 3.Levelling Accuracy: High level accuracy with smooth and jerk free stopping. 4.Construction of Car: High quality stainless steel car with Neat hair line finish vinyl flooring and false ceiling.
21.Fire Man's switch: To be provided at ground floor. 22.Minor builders work: included in the scope. 23.Scaffolding: Included in the scope 24.Sill angles and facia plates: included in the scope. 25.Steel for lift machinery: Included in the scope. 26.Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by lift contractor during the guarantee period of one year. 27.Automatic Rescue device: To facilitate the landing of the lift to the nearest floor at the time of power failure. This shall consists of suitable type battery system with charger, invertor, under voltage protection system etc., complete with all accessories. 28.Intercom:To be provided by the lift contractor with in-built intercom ( push type) in car panel and with provision of push type intercom in machine room and ground floor entrance. 29.Floor annunciator with music with announcement in both Tamil and English. 30.Special features: a. Infra-red door sensor with full height c.Voltage stabilizer for circuit control. d.Stainless Steel signal fixtures. e.Vandal proof S.S. Button with S.S. cover f.SS door frames for landing doors. g.VF door operator. h.Call Register signal i.Stainless steel facia plate for car operating anel and landing fixtures. j.On - Off switch for fan and light.
k. Over load warning indicator with audio announcement 31.Other standard features: Over speed governor, phase failure and phase reversal relay alarm bell, T. Guide brackets for car and counter weight, rubber padding under winding unit, motor of adequate capacity, electro magnetic brake with compression springs car safety gears buffer, electro mechanical door locks emergency key side supporting angles, motor over load protection devices final limit switch main suspension ropes counter weights lifting joint joist for mounting the machineries. 32.Guarantee: Guarantee for the materials and workmanship of equipments complete should be offered by lift firm for a period of not less than one year. 33.Site testing in accordance with IS 14665 should be carried out at the time of handing over. 34. Supply of operation and maintenance manual with necessary tools for operation. 35. Lift licence : Preparation of drawing, payment of charges to CEIG and insurance policies if any and obtaining CEIG safety certificate as per lift act should be done by lift contractor.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.07 MB
Formthenighelectrical.pdf
Tender Documents • 1.31 MB
BOQ_777914.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid