Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹28.9 L+₹56,196 (1.99%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹29.1 L+₹80,441.75 (2.84%)Admitted-Finance RC MINTRI ROAD KALIMPONG 734301 WB | KALIMPONG | KALIMPONG | WEST BENGAL | 734301 | L3 | Admitted-Finance | |
| 4 | L4₹29.4 L+₹1.1 L (3.83%)Admitted-Finance OPPOSITE GHOOM DRC PO GHOOM DISTT DARJEELING WB PIN 734 102 | DARJEELING | WEST BENGAL | 734102 | L4 | Admitted-Finance | |
| 5 | L5₹29.5 L+₹1.1 L (4.05%)Admitted-Finance 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SANJAY SAW MILL L2 | C. M. AGARWAL AND CO L3 | GEETA CONSTRUCTION L6 | S K ENTERPRISES L5 | PRASAD PRADHAN AND SON L1 | Damdoo Bhutia L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for Filtration and dehydration of transformer oil of distribution transformers indoor/outdoor type of 11/0.433 KV, 63 kVA to 400 kVA 11 kV, minimum three cycle to achieve di electric strength of 40 kV for 1 minute at 2.5 mm gap as per relevant IS with portable filtration plant, testing of the oil break down voltage before filtration and after filtration complete all as specified an directed by Engr in charge.
Note : (i) Centrifuging Machine with all T&P & testing machine of oil required for dehydration is arrange by contracter.
(ii) Oil required for topping up the transformer will be measured & paid separatly.
(iii) The Report before filtration and after filteration to be submited by contractor in the approved format | 4,430 | Litre | 40 ₹1,77,200 | 42 ₹1,86,060 | 98 ₹4,34,140 | 41 ₹1,81,630 | 39 ₹1,72,770 Lowest | 45.13 ₹1,99,925.9 |
| 2.00 | Supply , replacement and topping up transformer oil HV grade as per IS 335 of 1993 Part II having dielectric strength of not less than 40 KV in the transformer at various locations complete all as specified an directed by Engr in charge. | 260 | Litre | 220 ₹57,200 | 220 ₹57,200 | 230 ₹59,800 | 227 ₹59,020 | 218 ₹56,680 Lowest | 226 ₹58,760 |
| 3.00 | M&L for taking out old unserviceable defective HV bushings on site from outdoor/indoor type distribution transformers of 11/0.433 kV and 63 KVA to 400 kVA and Supply and fix porcelain bushing with heat resistant gasket complete all as specified an directed by Engr in charge. | 9 | Each | 780 ₹7,020 | 785 ₹7,065 | 780 ₹7,020 | 800 ₹7,200 | 770 ₹6,930 | 766 ₹6,894 Lowest |
| 4.00 | M&L for taking out old unserviceable defective LV bushings on site from outdoor/indoor type distribution transformers of 11/0.433 kV and 63 KVA to 160 kVA and Supply and fix porcelain bushing with heat resistant gasket complete all as specified an directed by Engr in charge. | 12 | Each | 335 ₹4,020 | 340 ₹4,080 | 350 ₹4,200 | 344 ₹4,128 | 330 ₹3,960 Lowest | 330.13 ₹3,961.56 |
| 5.00 | M&L for taking out old unserviceable defective LV bushings on site from outdoor/indoor type distribution transformers of 11/0.433 kV and 200 KVA to 400 kVA and Supply and fix porcelain bushing with heat resistant gasket complete all as specified an directed by Engr in charge. | 12 | Each | 480 ₹5,760 | 485 ₹5,820 | 490 ₹5,880 | 490 ₹5,880 | 470 ₹5,640 Lowest | 480 ₹5,760 |
| 6.00 | Supply and fix in repairs brass terminal stud, both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for HV side 11000 volts grade for 63 KVA to 400 KVA capacity of outdoor/indoor type transformer.complete all as specified an directed by Engr in charge. | 8 | Each | 900 ₹7,200 | 905 ₹7,240 | 890 ₹7,120 | 920 ₹7,360 | 885 ₹7,080 Lowest | 888 ₹7,104 |
| 7.00 | Supply and fix in repairs brass terminal stud both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for LV side 415 volts grade for 63 KVA to 160 KVA capacity of outdoor/indoor type transformer complete all as specified an directed by Engr in charge. | 4 | Each | 965 ₹3,860 | 970 ₹3,880 | 1,100 ₹4,400 | 990 ₹3,960 | 950 ₹3,800 Lowest | 1,000 ₹4,000 |
| 8.00 | Supply and fix in repairs brass terminal stud both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for LV side 415 volts grade for 200 KVA to 400 KVA capacity of outdoor/indoor type transformer. | 4 | Each | 1,900 ₹7,600 | 1,910 ₹7,640 | 1,990 ₹7,960 | 1,945 ₹7,780 | 1,870 ₹7,480 Lowest | 1,877 ₹7,508 |
| 9.00 | M&L for servicing/overhauling , Calibration and decorbonising of 11 kV (panel with breaker + Relay ) and setting of Relay parameters VCB of capacity 400/630 Amps, indoor type , taking shut down from MRS and disconnecting incoming & out going cables , control cables from VCB and replacement of un-serviceable spares, greasing of revolving assembly in VCB chamber, spring charging mechanism including decorbonising the VCB panel and check servicability all as specified and directed by Engr -in - charge.
Note: -
(i) : Spare parts/components required for replacement of above shall be measured and paid separately. (ii) Unit rate quoted against this item shall also include labour required for fixing of replaced items.
(iii) For item No. 10 to 30 fixing charge of items are considered in item no. 9. | 11 | Each job | 16,700 ₹1,83,700 | 16,800 ₹1,84,800 | 18,500 ₹2,03,500 | 17,000 ₹1,87,000 | 16,500 ₹1,81,500 Lowest | 17,000 ₹1,87,000 |
| 10.00 | Supply only Feeder protection numerical relay with features of earth fault, phase fault,Over current and fault recording Facility complete all as specified and directed. | 2 | Each | 27,450 ₹54,900 | 27,600 ₹55,200 | 28,550 ₹57,100 | 28,000 ₹56,000 | 27,000 ₹54,000 Lowest | 27,555 ₹55,110 |
Tender Value
₹25.3 L
EMD Value
₹50,500
Closing Date
30 Oct 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
REPAIR/REPLACEMENT/MAINT OF 11 KV HT OVERHEAD AND UNDERGROUND CABLES AND CONNECTED ITEMS AT KALIMPONG AND SERWANI MIL STN UNDER GE 867 EWS
2026_MES_792824_1
CWE/136-WE/60 OF 2026-27
Open Tender
Civil Works
Item Rate
180 days
Kalimpong
Class D, Category b(ii)
8 documents required · 8 mandatory
₹500
Yes
GE 867 EWS
₹50,500
Yes
12 Nov 2026
8 Oct 2026
31 Oct 2026
8 Oct 2026
30 Oct 2026
23 Oct 2026
8 Oct 2026 - 16 Oct 2026
60 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for Filtration and dehydration of transformer oil of distribution transformers indoor/outdoor type of 11/0.433 KV, 63 kVA to 400 kVA 11 kV, minimum three cycle to achieve di electric strength of 40 kV for 1 minute at 2.5 mm gap as per relevant IS with portable filtration plant, testing of the oil break down voltage before filtration and after filtration complete all as specified an directed by Engr in charge.
Note : (i) Centrifuging Machine with all T&P & testing machine of oil required for dehydration is arrange by contracter.
(ii) Oil required for topping up the transformer will be measured & paid separatly.
(iii) The Report before filtration and after filteration to be submited by contractor in the approved format | 4,430 | Litre | - | - |
| 2 | Supply , replacement and topping up transformer oil HV grade as per IS 335 of 1993 Part II having dielectric strength of not less than 40 KV in the transformer at various locations complete all as specified an directed by Engr in charge. | 260 | Litre | - | - |
| 3 | M&L for taking out old unserviceable defective HV bushings on site from outdoor/indoor type distribution transformers of 11/0.433 kV and 63 KVA to 400 kVA and Supply and fix porcelain bushing with heat resistant gasket complete all as specified an directed by Engr in charge. | 9 | Each | - | - |
| 4 | M&L for taking out old unserviceable defective LV bushings on site from outdoor/indoor type distribution transformers of 11/0.433 kV and 63 KVA to 160 kVA and Supply and fix porcelain bushing with heat resistant gasket complete all as specified an directed by Engr in charge. | 12 | Each | - | - |
| 5 | M&L for taking out old unserviceable defective LV bushings on site from outdoor/indoor type distribution transformers of 11/0.433 kV and 200 KVA to 400 kVA and Supply and fix porcelain bushing with heat resistant gasket complete all as specified an directed by Engr in charge. | 12 | Each | - | - |
| 6 | Supply and fix in repairs brass terminal stud, both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for HV side 11000 volts grade for 63 KVA to 400 KVA capacity of outdoor/indoor type transformer.complete all as specified an directed by Engr in charge. | 8 | Each | - | - |
| 7 | Supply and fix in repairs brass terminal stud both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for LV side 415 volts grade for 63 KVA to 160 KVA capacity of outdoor/indoor type transformer complete all as specified an directed by Engr in charge. | 4 | Each | - | - |
| 8 | Supply and fix in repairs brass terminal stud both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for LV side 415 volts grade for 200 KVA to 400 KVA capacity of outdoor/indoor type transformer. | 4 | Each | - | - |
| 9 | M&L for servicing/overhauling , Calibration and decorbonising of 11 kV (panel with breaker + Relay ) and setting of Relay parameters VCB of capacity 400/630 Amps, indoor type , taking shut down from MRS and disconnecting incoming & out going cables , control cables from VCB and replacement of un-serviceable spares, greasing of revolving assembly in VCB chamber, spring charging mechanism including decorbonising the VCB panel and check servicability all as specified and directed by Engr -in - charge.
Note: -
(i) : Spare parts/components required for replacement of above shall be measured and paid separately. (ii) Unit rate quoted against this item shall also include labour required for fixing of replaced items.
(iii) For item No. 10 to 30 fixing charge of items are considered in item no. 9. | 11 | Each job | - | - |
| 10 | Supply only Feeder protection numerical relay with features of earth fault, phase fault,Over current and fault recording Facility complete all as specified and directed. | 2 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
tenderdocumentspdf.pdf
Tender Documents • 1.03 MB
BOQ_889032.xls
BOQ • 0.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .