Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹2.6 L+₹8,835 (3.52%)Rejected-Finance | L2 | Rejected-Finance Second lowest |
Tender Value
₹2.2 L
EMD Value
₹3,340
Closing Date
10 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
BSNL Civil Dn Aizawl
Executive Engineer BSNL Admn building Upper khatla Aizawl
Mtce and repairs to 2 nos type I 12 nos type II and 3 nos type III staffqtrs in satellite compound at Aizawl Mizoram
2022_BSNL_130726_1
18/2022-23/CD/BSNL/AZL
Open Tender
Civil Works
Item Rate
90 days
BSLN Qtrs Satelite compound Aizawl
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
Account Officer (Cash), BSNL, Aizawl Mizoram
₹3,340
24 Nov 2022
1 Oct 2022
12 Oct 2022
1 Oct 2022
10 Oct 2022
1 Oct 2022
Amount
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
(a) 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes.
(a) 110 mm dia
Providing and fixing unplasticised PVC moulded fittings and accessories for unplasticised rigid PVC moulded fittings and accessories for unplasticised rigid PVC pipes including jointing with seal ring etc. complete.
(a) 110 mm Bend 87.5°
(b) 110 mm Single tee with door
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:
(a) Float glass panes of thickness 4 mm.
Renewing glass panes and refixing existing wooden fillets:
(a) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
Cleaning and de-silting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge.
Cleaning of under ground sump, Over Head R.C.C. Tank (independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i) Tank shall be emptied of water by pumping & bottom shall be cleaned of slit and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge.
Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineerin Charge. (a) Internal Work- Exposed on wall
Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
(a) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : a)15 mm to 40 mm nominal bore
Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
(a) 15 mm nominal dia. Pipes.
(b) 20 mm nominal dia. Pipes.
( C ) 25 mm nominal dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
(a) 15 mm nominal dia. Pipes.
(b) 20 mm nominal dia. Pipes.
( C ) 25 mm nominal dia .Pipes.
(d) 40 mm nominal dia .Pipes.
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
(a) 20mm nominal bore
(b) 25mm nominal bore
( C ) 40mm nominal bore
Providing and fixing PTMT bib cock of approved quality and colour.
(a) 15mm nominal bore, 86 mm long. Weighing not less than 88 gms.
Providing and fixing PTMT stop cock of approved quality and colour.
(a) 15 mm nominal bore, 86 mm long. Weighing not less than 88 gms.
Providing and fixing PTMT pillar cock of approved quality and colour .
(a) 15mm nominal bore, 107 mm long. Weighing not less than 110 gms.
Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps :
(a) 100 mm diameter
(b) 150 mm diameter
Cleaning of manholes by rodding, scrubbing and flushing to remove the clogged drain of sludge, waste & rubbish material and disposal of waste/ refuge/ filth etc. (recovered in this process) to a place permitted and approved by the Local Municipal corporation all as per the direction of Engineer-in-Charge.
Cleaning of sewer line by rodding, scrubbing and flushing to remove the clogged drain of sludge, waste & rubbish material and disposal of waste/ refuge/ filth etc. (recovered in this process) to a place permitted and approved by the Local Municipal corporation all as per the direction of Engineer-in-Charge. a)Sewer pipe line of dia. Upto 300mm.
P/F gun metal gate valve with lever of approved quality.
(a) 15mm nominal bore
Dismantling of gate valve including stacking of useful materials within 50 metres lead.
(a) Up to 150 mm diameter
Providing and fixing 4 mm thick ACG sheet incluing required nails etc complete as per direction of Engineer-in-charge.
Removal of sludge/ Night soil from septic tank and cleaning by engaging sewerman and stacking the night soil on ground for disposal and cleaning the surrouding area by using lime powder etc complete as per the direction of engineer in charge.(Septic tank of size up to (5.00 x 2.00 x 2.00) mt.
Providing and applying specified no of coats of acrylic polymer based waterproofing chemical coating of reinforced with micro-fibers & fungicides (NEWCOAT of Pidilite or equivalent) for waterproofing of terraces of any kind in following sequence of operations. a) Preparing existing plastered surface/ terrace etc. by scraping of loose flakes of algae/ paint/ dirt/ oil/ grease etc. with brush & scrapers etc. and wipe out all the loose dirt with profuse watering one day prior to treatment. b) Seal the exposed cracks if any with crack filling readymade putty (To be paid for separately under the relevant item) c) Apply a coat of seal primer of the same manufacturer diluted with water in 1 part water:2 part primer proportion and apply with brush. d) Allow primer coat to dry for 6 hours e) Apply two coat of acrylic polymer based waterproofing chemical coating successively with a gap of 6 hours between application of two coats without any dilution and quantity as stipulated by the manufacturer.
Providing,laying and jointing of PVC SWR grade drain pipes of M/S Supreme Co or equivalent including necessary fittings as per the direction of Engineer-in-charge.
(a) 160 mm dia
(b) 110 mm dia
Credit for the recovered items after dismantling or replacing the damaged items etc. (Note: 1. The rate quoted by the agency should be more than minimum reserve price. Any rate below the reserve price or no rate quoted will be considered as the rate of reserve price fixed and the amount of the item/s will be worked out on the basis of the minimum reserve price fixed for the item/s. 2. The materials will be handed over at site of work only, however BSNL reserves the right of using the recovered material, if required and the agency will not have any claim on any material if BSNL decides against handing over the items recovered from work at the quoted rate.)
(a) CP brass / bright brass / Gun metal fittings.
(b) PVC flush tanks, bib cocks, stop cocks etc
P.P. Engineering Works
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .