Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.0 L+₹2.2 L (16.2%)Rejected-Finance 1476 SARASWATI COLONY CHERITAL JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹18.8 L+₹5.0 L (36.1%)Rejected-Finance 292 GROUND FLOOR D BLOCK SAI DHAM RAJ CITY LONI BANTHLA GHAZIABAD GHAZIABAD UTTAR PRADESH 201102 | GHAZIABAD | UTTAR PRADESH | 201102 | L3 | Rejected-Finance Being L3 |
Tender Value
₹13.9 L
EMD Value
₹27,800
Closing Date
5 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) (P) Fy Jabalpur
GE (I) (P) Fy Jabalpur PO-Khamaria PIN-482005
PROVISION OF INFRASTRUCTURE FOR NAVAL COMMUNICATION NETWORK (NCN) IN NAI AT JABALPUR UNDER GE (I) (P) FYS JABALPUR
2021_MES_409212_2
8371/KH/E8
Open Tender
Civil Works
Item Rate
240 days
Jabalpur
As per eNIT
7 documents required · 7 mandatory
₹500
GE (I) (P) Fy Jabalpur
₹27,800
Yes
18 Jun 2021
9 Feb 2021
11 Mar 2021
9 Feb 2021
5 Mar 2021
19 Feb 2021
60 days
Amount
Supply installation and testing of Room window type air conditioner electric driven (single phase), 230 Volt, 50 Hz, Cooling capacity 6000 K Cal per hour (2 Ton), 5 star rated, with inverter compressor, cordless remote control unit, Auto Air Swing, Air Flow Direction 4 Way and Speed Setting complete with all accessories, including cutting/opening the existing wall suitable for mounting the AC and make good disturbed surfaces all as directed. Make : LG Model No. JW-Q24WUZA or equiv of Voltas/Samsung/Godrej/Blue Star/Daikin/Carrier.
Supply installation and testing of Room window type air conditioner electric driven (single phase), 230 Volt, 50 Hz, Cooling capacity 4500 K Cal per hour (1.5 Ton), 5 star rated, with inverter compressor, cordless remote control unit, Auto Air Swing, Air Flow Direction 4 Way and Speed Setting complete with all accessories, including cutting/opening the existing wall suitable for mounting the AC and make good disturbed surfaces all as directed. Make : LG Model No. JW-Q18WUZA or equiv of Voltas/Samsung/Godrej/Blue Star/Daikin/Carrier.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA
S&F Single pole and neutral sheet metal enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amps all as specified and directed.
M&L for wiring with two single core, multi stranded, PVC insulated, 1100 Volt grade, FRLS, cable with copper conductor of size 6 Sq mm in and including/drawing through rigid non metalic PVC conduit including continuous PVC insulated copper conductor single core earth continuity conductor of size 6 Sqmm connected to common earth. (Note : 2x 6 Sq mm conductor cable, 1 x 6 Sq mm conductor earth continuity cable & PVC conduit shall be measured as one unit length).
Supply installation testing and commissioning of transformer step down, outdoor type, with all standard fittings, 11000Volts/433 Volts, AC, 3 phase, 4 wire, 50 Hz, Copper wound, oil immersed naturally air cooled with external cooling tubes, with off load tap changer on HT side to vary secondary voltage +5 % to -10% in steps of +/- 2.5 % as per IS : 2026 of capacity 63 KVA and oil shall conform to IS 335 of 1983 including first filling of oil complete, LV side cable termination end box, uni-directional roller, conservator, silica gel breather, drain, filter valves and LV cable gland including provision of all necessary standard fittings and mainly comprising of the following :- (a) Primary HT side having HT porcelain bushing 03 Nos with brass gun metal bushing rods complete with nuts and washers. (b) one cable box on secondary (LT) side consisting of 4 Nos porcelain bushings with GM bushing rods complete with GM nuts, and washers with one No. cable gland sitable for reception of outgoing LT PVC sheathed armoured cables of size 120 sqmm 3.5 core. (c) Oil conservator with filter type, drain valve and oil level gauge. (d) Dehydrating breather with first fill of dehydrating agent. (e) Explosive vents. (f) Thermometer pocket on tank cover. (g) One No. 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting device. (Note : Transformer shall be mounted on 2 Pole structure and 2 Pole structure will be measured and paid separately under relevent items of this schedule).
S&F Switch air break, gang operated, out door type, triple pole, HT 11000 volts, 200 Amps, vertical type with 3 insulators mounted with fixed contacts of phospor bronze and moving contacts of copper, manually operated from ground level with operating mechanism including mild steel galvanised light grade 25mm bore operating rod, pad locking arrangement, complete all as specified and directed.
S&F Drop out expulsion fuse assembly with fuse carrier, triple pole HT 11000 Volts, 200 Amps, out door type (having two Nos post insulators mounted on MS Channel for each pole) all as specified and directed.
S&F Lightening arrestors Expulsion type complete with all fitting, transmission class, discharge capacity 5 kilo Amps suitable for 9000 Volts and connecting to earth wire complete all as directed.
Supply and errect Steel tubular swaged poles type 410 SP-55, 11.0 metres long, complete with MS base plate, finial taper plug, bolts, nuts, screws and top cover all as specified and including the following:- (a) Excavation in trenches not exceeding 1.5 mtr wide and 1.9 mtr deep for pole foundation and getting out in soft/loose soil, returning filling in the excavation of soil after fixing the pole in foundation ramming earth around in layer not exc 25cm thick and disposal of surplus soil to a distance not exc 50 mtrs. (b) Material and labour for providing PCC 1:4:8 type D-2, using 40mm graded stone aggregate as in foundation, 600 mm x 600 mm cross section planting depth 1.8 mtr and 10 cm base for concrete casing the pole upto GL complete all as directed. (c) Material and labour for providing PCC 1:2:4 type B-2, using 40mm graded stone aggregate for plinth block/collar above GL 300 mm high and 450mm dia all as directed. (d) Material and labour for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block/concrete collar with two coat of aluminium paint over a coat of red oxide steel primer.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural mild steel sections conforming to Fe-290 Gde E-165 including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces complete all as specified. (Notes : (i) Sizes & types of members and shape of the cross arms etc shall be as required at site all as directed by the Engr-in-Charge.(ii) Un-exposed steel surfaces shall be given one coat of red-oxide zinc chromate primer only).
Supply & Stringing Aluminium conductor, steel reinforced (ACSR) on HT/LT poles and for jumper connections of size as ordered including providing coloured sleaves for jumper connections, complete all as specified and directed.
M&L for Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole).
S&F Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia. for 11000 volts grade complete all as specified.
S&F Disc type insulator, porcelain, vitreous, 145 mm high and 255mm dia, ball & socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified.
Supply and laying in trenches/through pipes or bare in road crossings/paths/drains/ ducts/floors/along poles/walls/ ceilings/ equipments etc. Cable Under ground, Heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of cross sectional area 120 Sqmm 3.5 core all as specified and directed.
All as per item No. 17 here-in-before but 70 Sqmm 3.5 core.
Supply and Fixing Sheet metal enclosure for DBs when MCBs to be Used, 4 way, TP & N, double door type, 440 Volt, suitable for MCCB incomer 63 A, 4 Pole, 16 KA. (Note : MCCB and MCBs will be Measured separately).
Supply and Fixing MCCB, four pole, 63 Amp, 415 Volt, of capacity breaking capacity 16 KA.
Supply and Fixing Miniature circuit Breakers, single pole, 240 Volts of capacity (6-32 Amps) as ordered breaking capacity 10 KA.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below ground level, connecting GI earth wire of size 4 mm dia from earth plate to body of the equipment by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 15 mm bore GI light grade pipe for protection of earth lead from earth plate (6 mtrs long), 20 mm GI light grade watering pipe, PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in earhing pit, PCC cover, charcoal or coke & salt filling and necessary excavation and earth work and all other relevant works including testing all as specified and shown in electrical plate No.3 of MES Schedule part-I.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below ground level, connecting GI strip of size 32mm x 6mm from earth plate to body of the equipment by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40 mm bore GI light grade pipe for protection of earth lead from earth plate(6 mtrs long), 20 mm GI light grade watering pipe, PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in earhing pit, PCC cover, charcoal or coke & salt filling and necessary excavation and earth work and all other relevant works including testing all as specified and shown in electrical plate No.3 of MES Schedule part-I.
Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and not exceeding 1.5 m in depth and getting out complete all as specified.
Returning, filling in, trenches including spreading leveling, watering and well ramming in layers not exc 25 cm.
Removing excavated material to a distance not exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point.
M&L for cushioning for protection of cable using dry river sand, free from particles all as specified and directed.
M&L for Protection to cable with one layer of new bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks.
Supply and lay in trenches/under roads/crossings are fixed to wall/pole, GI tubing light grade of following sizes for protection of UG cables of 80 mm dia. (Note : Payment for excavation and earth work shall be paid for separately under relevant items of Schedule)
All as per item No. 29 here-in-before but 50mm dia.
Supply and Fixing Exhaust fan, heavy duty, 230 Volt, 50 Hz, Single Pole, 450 mm sweep, complete with louvers and all accessories, including making necessary opening in the wall, fixing on wall using necessary nuts, bolts and washers all as directed.
Disconnecting in coming HT and out going LT cable connections and taking down Transformer of any type/size/make/capacity from 2/4 Pole structure and shifting to new location with in 100 mtr and install where directed, refixing HT/LT cable connections complete all as directed.
Supply & Laying Insulation Rubber Mat 12 mm thick 1 Mtr x 2 Mtr Size with ISI Marking including taking out old U/S mats and remove from site.
M& L for cutting the existing hard standing/PCC/WBM road at a depth not less than 30 cm and 25 cm in width for passing of cable through GI pipe, returning filling in, complete including finishing the surfaces by providing cement concrete type B-1 (1:2:4) with 20 mm graded aggregate upto 20 cm, finishing to a uniform smooth surface complete all as specified and directed.
M&L for loose filling of 40 mm graded stone aggregates in plinths of out door transformer, sub stns, panel boards yard complete all as directed.
Cleaning the vegetation around two/four pole structure & transformer yard/Sub stn including preparation of site for spreading stone aggregates etc all as directed at site.
Supply & Fixing in repairs Danger notice plate for HT of size 25cm x 20 cm x 1.60 mm thick, mild steel sheet, vitreous, enamelled white, with letters, figures and conventional skull & bones in single red colour and fixed with MS clamps, bolts of required size complete all as specified.
RAINA SALES AND SERVICES
Goodluck Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .