Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 CrAccepted-AOC LUDHIANA | ₹5.0 Cr | L1 | Accepted-AOC low |
| 2 | L2₹5.0 CrRejected-AOC | ₹5.0 Cr | L2 | Rejected-AOC High |
| 3 | Rejected-Technical PUNJAB | - | - | Rejected-Technical Insufficient Bid Capacity |
| Sl No | Description | Qty | Unit | PARVEEN SEHGAL CONT. L2 | R S BUILDERS L1 |
|---|---|---|---|---|---|
| 1.00 | Earth work in excavation of foundations of bridges culverts, buildings including handling of material with a combined lead of 15 metres dressing of bed and sides stacking the excavated soil from the edge of excavation and subsequent filling (a) For ordinary gravel soil involving pick work | 1,063.26 | cum | 305 ₹3.2 L | 321 ₹3.4 L |
| 2.00 | Cement concrete 1:3:6 mixing by mechanical means using concrete mixer volumetric type | 83.35 | cum | 4,400 ₹3.7 L | 4,421 ₹3.7 L |
| 3.00 | Cement concrete 1:4:8 with stone ballast 20 mm gauge mixing by mechanical means | 124.07 | cum | 4,115 ₹5.1 L | 4,100 ₹5.1 L |
| 4.00 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. | 151.24 | cum | 6,420 ₹9.7 L | 6,700 ₹10.1 L |
| 5.00 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level | 79.2 | cum | 6,280 ₹5.0 L | 6,800 ₹5.4 L |
| 6.00 | 20mm thick cement plaster 1:4 in two coat work | 660.64 | sqm | 290 ₹1.9 L | 301 ₹2.0 L |
| 7.00 | 12.5 mm thick cement plaster 1:4 in two coat work | 851.12 | sqm | 210 ₹1.8 L | 251 ₹2.1 L |
| 8.00 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer asper IS:1791andvibrated by needle vibrator but excluding steel reinforcement centering and shuttering in foundation and plinth | 91.42 | cum | 6,000 ₹5.5 L | 6,251 ₹5.7 L |
| 9.00 | Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in foundation and Plinth | 7.37 | cum | 6,300 ₹46,431 | 6,500 ₹47,905 |
| 10.00 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in superstructure. | 39.58 | cum | 6,800 ₹2.7 L | 6,900 ₹2.7 L |
Tender Value
₹5.1 Cr
EMD Value
₹10.2 L
Closing Date
28 Mar 2026, 12:10 pmClosed
Executive Engineer
office of Executive Engineer,Ropar canal and GWD
Estimate for construction of pump house including all components at Village Chajja in Distrcit Ropar
2026_WR_162489_2
79/22A/2025-26
Open Tender
Civil Works
100 days
village chajja near nurpur bedi
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
₹10.2 L
office of Executive Engineer,Ropar canal and GWD
15 May 2026
17 Mar 2026
28 Mar 2026
17 Mar 2026
28 Mar 2026
17 Mar 2026
24 Mar 2026
Earth work in excavation of foundations of bridges culverts, buildings including handling of material with a combined lead of 15 metres dressing of bed and sides stacking the excavated soil from the edge of excavation and subsequent filling (a) For ordinary gravel soil involving pick work
Cement concrete 1:3:6 mixing by mechanical means using concrete mixer volumetric type
Cement concrete 1:4:8 with stone ballast 20 mm gauge mixing by mechanical means
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level
20mm thick cement plaster 1:4 in two coat work
12.5 mm thick cement plaster 1:4 in two coat work
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer asper IS:1791andvibrated by needle vibrator but excluding steel reinforcement centering and shuttering in foundation and plinth
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in foundation and Plinth
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in superstructure.
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer asper IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in superstructure.
Cement concrete 1:2:4 mixing by mechanical means using concrete mixer volumetric type with stone ballast 20mm gauge with stone ballast or shingle mixing by manual means
Supplying, fitting and placing HYSD bar reinforcement in sub structure complete as per drawing and Technical Specifications.
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Centering and shuttering for sides and soffits of beam,launching girders, bressumers, lintels.
Centring and shuttering for columns(Square or Rectangular)
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Preparation of plastered or concrete surface for painting (including sand papering the surface) using acryllic Wall Putty by applying two or more coats to get required finish including priming coat to make an even surface before applying acrylic wall putty on new plastered surface.Complete as per specifications
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre /10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in charge. (c) Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects
Providing and fixing 14gauge MS sheet garage doors with 40mmx40mmx6mm angle iron frame with diagonal braces 3.15mm gusset plates including locking arrangement with handles etc. complete in respects
Supplying and fixing rolling shutters, of approved make, made of 80mmx1.25mm, M.S. Laths, interlocked together through their entire length and jointed together, at the end, by end locks, mounted on specially designed pipe shaft, with brackets, side guides, 27.5cm long wire spring grade No. 2 and arrangement for inside and outside locking with push and pull operation complete, including top cover 0.80 mm thick (payment is to be made for the exact size of opening where rolling shutter is to be fixed)
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40 mm gauge and 100 mm fine sand filling using mechanical mixer for mixing of material
Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete.(600mm x600 mm)
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS:15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1cement:4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M-35 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in- Charge
Advance Direction sign board 1200 x 1800 mm rectangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. fixed over 4mm thick Aluminium Composite Material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on two square hollow steel section post 60x60x3.2mm conforming to IS 4923 firmly fixed to ground in foundation concrete M-25 of size 0.60x0.60x0.75m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012. d(i) Using high intensity Microprismatic grade retro reflective Sheeting Type IV as per ASTM D 4956 09 and as per IRC 67 2012
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. Size 550 mm x 400 mm x 815 mm
Providing & fixing in position vitreous Chinware white Indian make flat back or angular lipped front small urinals size 265x315x440mm approved make (to the approval of the Engineer-in-charge) with C.P. brass tube connection 300 mm long complete in all respect.
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. C.P. brass towel Rails size 15mm dia 610mm long
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) Size 600mmx450mm
Providing & fixing in position 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge) complete in all respect. C.P. brass Bib cock foam flow without flange
Providing & fixing in position stop cock / Angle valve of approved make (to the approval of Engineer-in-charge) complete in all respect. C.P. brass 15mm Angle valve without flange
Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 300 mm with C.P. Brass nut
Providing and fixing jet spray with 2'-6" long PVC pipe.(a) With C.P. Brass nut
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. Size 75 mm x 75 mm
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank (i) Triple Layer Tanks
Providing & fixing in position on terrace (at all floor levels) HDPE tank cover for water storage tanks of approved make (to the approval of Engineer-in-charge) complete in all respect. Upto 500 ltr capacity tank
Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. G.I. tank nipple 20mm i/d
Providing and fixing in position automatic brass Ball Cock in tanks. B Brass Ball Cock with rod and Plastic Ball (ii) 20 mm i/d
Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect.
Providing, fixing and jointing ISI Marked Gun Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete. (b) 20 mm i/d Gun Metal peet valve heavy pattern.
Making connection with the existing G.I. branch main up to 40mm size pipe including cutting of existing pipe line, threading of pipe lines from both ends and fixing of G.I Tee etc. in the pipe line (including cost of G.I Tee) complete in all respects existing G.I. branch main up to 40mm size pipe including cutting of existing pipe line, threading of pipe lines from both ends and fixing of G.I Tee etc. in the pipe line (including cost of G.I Tee) complete in all respects
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. a)110 mm o/d
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipesasper IS15778(ISImarked with the prior approval of Engineer-in Charge), havingthermalstabilityforhot& cold water supply, including all CPVC plain&brass threaded fittings i/c fixing thepipewithclamps at 1.00mspacing includingjointingofpipes& fittings,with onestepCPVCsolventcementan dtesting of pipes complete as per direction of Engineer-in-Charge. SDR11CPVCpipes& fittings20mm o/d
INTERNAL- EXPOSED ON WALL : ProvidingandfixingChlorinated Polyvinyl Chloride(CPVC) pipesasperIS15778(ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, includingallCPVCplain& brassthreaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointingof pipes&fittingswithonestep PVCsolvent cement andtestingofpipes completeasperdirectionofEngin eer-in Charge. SDR11CPVCpipes& fittings20mm o/d
EXTERNAL INTHEGROUND : Providing and fixingChlorinatedPolyvinylChlo ride (CPVC)pipesasper IS15778(ISImarked with the prior approval of Engineer-in Charge), havingthermalstabilityforhot& coldwatersupplyincludingallCP VCplain &brass threaded fittings. This includes jointingof pipes&fittingswithonestep CPVCsolvent cement,&testingof joints excludingcostofexcavationcom pleteas per direction of Engineer-in-Charge. SDR11CPVCpipes& fittings20mm o/d
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete1:2:4benching 12.50mm thick cement plaster 1:2 with a floatingcoat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping50mmthickwith455mm x 455mm, 455mm x 610mm inside R.C.C. inspectionchambercoverandfra me(Weight as per I.S.I specifications) painted with 3 coatsofblackbitumasticpaintco nformingto I.S.I complete as per standard design c) 600mmx900mminsidewith455 mmx455mm cover and frame light duty double seal
Constructing soakpit1.20x1.20x1.6mdeep, 230mmthick1: 5brickworkhoneycombwith bricks of Ist Class filled with brickbats includingS.W. drainpipe100mmDiametre and1.20m longcompleteasper standard design
Providingand fixing inpositionsingel socket SWRUPVCsoilwasteorantisyph onagepipes asper IS13592ofE.D.Cmanufactureor of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type A d) 90 mm o/dsinglesocket SWRUPVC pipe lines laid complete
Providingand fixing inposition15mmC.P. Pillarcock foamflow ofapprovedmake(to the approval of Engineer-in-charge)
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavygaugePVCconduitpipe20 mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealedmetal boxes (1.6mm thick with Brass lugs) required forsuitablenumberof modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered) 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp. switcheswith indicator etc. andcoveredwithFramePlate etc., PVCconnector (For FanBoxandCall Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junctionBoxes (FourwayPVC1½"deepfor wallsandCI3"deepforceiling), bondingto earthwithPVC insulatedcopper conductor singlecoreFRcable (ISImarked) 1sq.mm, 1100volts grade (For 6Amp. wall socket & plugcontrol point) andotherpettymaterial etc., including the cost of abovematerial, cutting and filling up of chases (with finishing the surface) Wiring fan point (With fan box)
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavygaugePVCconduitpipe20 mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealedmetal boxes (1.6mm thick with Brass lugs) required forsuitablenumberof modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp. switcheswith indicator etc. andcoveredwithFramePlate etc., PVCconnector (For FanBoxandCall Bell), Steel Hooks Sheet metal fan box (1.6mm thick shape hexagonal), Circular junctionBoxes (FourwayPVC1½"deepfor wallsandCI3"deepforceiling), bondingto earthwithPVC insulatedcopper conductor singlecoreFRcable (ISImarked) 1sq.mm, 1100volts grade (For 6Amp. wall socket & plugcontrol point) andotherpettymaterial etc., including the cost of abovematerial, cutting and filling up of chases (with finishing the surface) Wiring light point
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavygaugePVCconduitpipe20 mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealedmetal boxes (1.6mm thick with Brass lugs) required forsuitablenumberof modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp. switcheswith indicator etc. andcoveredwithFramePlate etc., PVCconnector (For FanBoxandCall Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junctionBoxes (FourwayPVC1½"deepfor wallsandCI3"deepforceiling), bondingto earthwithPVC insulatedcopper conductor singlecoreFRcable (ISImarked) 1sq.mm 1100volts grade (For 6Amp. wall socket & plugcontrol point) andotherpettymaterial etc., including the cost of abovematerial, cutting and filling up of chases (with finishing the surface) Wiring 6Amp. wall socket point
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavygaugePVCconduitpipe20 mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealedmetal boxes (1.6mm thick with Brass lugs) required forsuitablenumberof modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp. switcheswith indicator etc. andcoveredwithFramePlate etc., PVCconnector (For FanBoxandCall Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junctionBoxes (FourwayPVC1½"deepfor wallsandCI3"deepforceiling), bondingto earthwithPVC insulatedcopper conductor singlecoreFRcable (ISImarked) 1sq.mm, 1100volts grade (For 6Amp. wall socket & plugcontrol point) andotherpettymaterial etc., including the cost of abovematerial, cutting and filling up of chases (with finishing the surface) Wiring 16/20Amp. power plug control point
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavygaugePVCconduitpipe20 mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealedmetal boxes (1.6mm thick with Brass lugs) required forsuitablenumberof modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp. switcheswith indicator etc. andcoveredwithFramePlate etc., PVCconnector (For FanBoxandCall Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junctionBoxes (FourwayPVC1½"deepfor wallsandCI3"deepforceiling), bondingto earthwithPVC insulatedcopper conductor singlecoreFRcable (ISImarked) 1sq.mm, 1100volts grade (For 6Amp. wall socket & plugcontrol point) andotherpettymaterial etc., including the cost of abovematerial, cutting and filling up of chases (with finishing the surface) Wiring light point with double control switches.
DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:Supply and erection of sheet metal DoubleDoorDistributionBoards IP43 IK09metal door (dustprotected) asper IS8623-1&3, IEC61439-1&3suitable for flush mounting with fully insulated copperbusbars, shroudedneutral bars, earthbars,cementspillprotector ,color coded interconnecting wire set, cable ties, blanking plates and circuit identifications label andof requiredno. ofways formounting miniaturecircuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/RCCB's/RCBO'sasincom erand SPMCB's asoutgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer andSPMCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc SP& NDoubleDoorDistributionBoard 8way each
MINIATURE CIRCUIT BREAKERS SupplyanderectionofMiniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415volts 50cycles AC supply with breaking capacityof 10kA,Curve-Cand lowwatt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existingMCBdistributionboarda sper PWDGeneral Specifications including connections with suitable size of thimbles/lugs: MCB Single Pole 6-32amp. (10kA, Curve-C)
MINIATURE CIRCUIT BREAKERS SupplyanderectionofMiniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415volts 50cycles AC supply with breaking capacityof 10kA,Curve-Cand lowwatt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existingMCBdistributionboarda sper PWDGeneral Specifications including connections with suitable size of thimbles/lugs: MCBSinglePole50
SupplyanderectionofPVCinsula tedFR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS: 694/1990leftbareinpipeorcasin gof suitablesizecomplete inall respect as desired by the Engineer-in-charge: Overall size 1sq.mm (Un-sheathed)
SupplyanderectionofPVCinsula tedFR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS: 694/1990leftbareinpipeorcasin gof suitablesizecomplete inall respect as desired by the Engineer-in-charge: Overall size 1.5sq.mm (Un-sheathed)
SupplyanderectionofPVCinsula tedFR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS: 694/1990leftbareinpipeorcasin gof suitablesizecomplete inall respect as desired by the Engineer-in-charge: Overall size 2.5sq.mm (Un-sheathed)
SupplyanderectionofPVCinsula tedFR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS: 694/1990leftbareinpipeorcasin gof suitablesizecomplete inall respect as desired by the Engineer-in-charge: Overall size 4sq.mm (Un-sheathed)
SupplyanderectionofPVCinsula tedFR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS: 694/1990leftbareinpipeorcasin gof suitablesizecomplete inall respect as desired by the Engineer-in-charge: Overall size 6sq.mm (Un-sheathed)
Providing & fixing make ISI marked Cast steell class 300 Sluice valve Dia 250 mm SS flanges, Champion rubber join, jointing, testing, and all carriage etc all SS fittings complete in all respect . Quality as per satisfaction and with the approval of Engineer-In-Charge
Providing,Stringingout, cutting, Jointing and testing of ISIMarkedD.I.Pipe(S&S)asper IS8329and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage, cost of rubber ring (A) D.I. Pipe as per IS 8329 DI-K7 (e)250mm i/d pipe lines laid complete.
Providing,Stringingout, cutting, Jointing and testing of ISIMarkedD.I.Pipe(S&S)asper IS8329and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage cost of rubber ring (A) D.I. Pipe as per IS 8329 DI-K7 (f)300mm i/d pipe lines laid complete.
Providing and fixing LED Batten 36W
Providing and fixing Flood light 100 w
Providing and fixing Fans roof slab 48"
providing and fixing propeller type heavy exhauset fan(450mm )
Providing and fixing Invertor(1625 Va) & Battery (150 ah) complete in all respect with satisfaction of engineer incharge..
Providing and fixing LED bulb 20W
Providing & fixing make ISI marked Cast steel class 300 NRV Dia 250 mm including SS flanges, Champion rubber join, including jointing, testing, and all carriage etc all SS fittings complete in all respect. Quality as per satisfaction and with the approval of Engineer-In-Charge.
Providing and fixing electro-magnetic digital flow metre of dia 250mm as approved by Engineer Incharge
Providing Supplying & fixing of Vaccum Pump 5HP
Providing, fixing, testing & commissioning of Electrically driven horizontal split casing non-clogging centrifugal pumps for delivering 90 LPS clear/raw water against a Head of 48 metre with CI casing and CF8M impeller SS shaft and coupled on MS fabricated base frame including cost of foundation bolts, flexible coupling & coupling guard & other contingent material fixed in position coupled with Electric Squirrel Cage Induction Motors of suitable Rating commensurate to the capacity of pump at 1450 RPM complete in all respects. The pump shall be compatible while operating with VFD.
Providing, fixing, testing & commissioning of Electrically driven horizontal split casing non-clogging centrifugal pumps for delivering 109 LPS clear/raw water against a Head of 37 metre with CI casing and CF8M impeller SS shaft and coupled on MS fabricated base including cost of foundation bolts, frame flexible coupling & coupling guard & other contingent material fixed in position coupled with Electric Squirrel Cage Induction Motors of suitable Rating commensurate to the capacity of pump at 1450 RPM complete in all respects. The pump shall be compatible while operating with VFD
Providing, fixing, testing & commissioning premium make LT panel (TTA Type) having 1000A Four Pole micro-processor ACB, 50kA based motorized ACB with electronic trip unit, protections againts overload, short-circuit, earth fault etc with display including 6 nos starter panels having VFD-100 HP Heavy Duty with in built choke with bypass star-delta starters option having contractors, digital suitable ECOR, phase sequence relay, suitable rating MPCB/MCCB and 6 nos DOL 5HP starters for vaccum pumps(withsuitableratingof MPCB) for Riser-1 and 2. Isolation/Control Transformer of rating- 250VA , 415/230 Volt(for individual feeder) for control supply completewithAmperemeter, volt meter etc. Feeders for Lighting Load included. As per specification document (enclosed) with UPS of suitablecapacity(3KVA) with6hrsbatterybackup
Supply, Erection, Testing & Commissiong of 800 kVA Transformer - 11kV/0.433kV as specifications attached conforming to IS 1180 part 1 (2014) and IS 2026 (with latest ammendments).
APFC Capacitor Panel of 270KVAR capacitors (in steps) for improving power factor upto 0.99 lagging having APFC relay with detuned reactors and capacitor duty contactors & having IS 13340 or latest relevant IS compliant.
Supply, Erection, Testing & Commissiong of 11 KV VCB Panel - having 800 Amp, 26.1kA drawout type VCB with numeric O/C and E/F relays and IEC 61850 compliant with, PT, CT (suitable for 800kVA transformer), protection relays (buckolz relay, master trip relay etc),power pack, energy meters, indicators,alarm announcitors.
Providing & fixing of mtc. Free (chemical) Earthing with GI strip of suitable size ( 50*5 mm) for all HT/ LT breakers, feeders panels transformer and motros/pumps conforming to IS 3043: 2018 and IS 735 etc. having two seprate earthing pits for HT & LT. Earth resistance equal to or less than 1.0 ohm with GI electrode.
Erection, installation, testing and commissioning of cabling works (for above Proposed items at Sr. no 1 to 6) having suitable sizes and ratings XLPE LT cables between motors and panel, transformer LT side to panel, 11 KV HT XLPE cable from metering unit (CTPT unit) to transformer panel and from VCB panel to transformer (HT Side) etc conforming to IS 7098 Part 1 & PVC Sheated conforming to IS 5831/1984 with latest ammendments and cables shall have aluminum conducter H2 grade as per IS 8130/2013 (armoured/unarmoured). Both LT & HT Cables should be drawn into trenches/racks & clamped properly.
MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCBs of various sizes 2/3 pole for circuit protection against overload and short circuit current fault suitable for 240/415volts 50cycles AC supply with breaking capacityof 10kA, Curve-Cand lowwatt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs: (b) MCB Single Pole50 63amp. (10kA,Curve)
Providing and fixing in position Cast IronFoot valves flanged ends with rubber sheat as per IS4038 including cost of Nut Bolt , rubber insertion complete in all respect (300mm i/d Cast Iron Foot valves)
Providing and fixing of FIRE EXTINGUISHER,CO2typeasper IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. (B) 3 Kg. Capacity
Providing,laying,fixing,testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts,gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts. 200mm internal diameter
Proving, supplying and fixing Fully electric operated 5 tonne gantry crane with traveller beam including all fittings and accessories complete in all respects as per approved Engineer Incharge.
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing inposition
Extra rate for shuttering workdone above 4 metres height (where any single torey exceeds 4metres in height) for every additional height of 1 metres or part thereof
(13.91) Water proofing treatment of Roof Slab with High performance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats ( Dr Fixit Roofseal flex - Packaging Size: 12 .5 kg (7.5 kg powder + 5 kg polymer) / equivalent water proofing Solution ). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge.
(13.17) Tile terracing laid dry over roof consisitng of one layer of tiles 22.86x11.43x3.83 including grouting with cemet sand mortar 1:4 top surface to be left clean after wire brushing
(22.2) Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications.
Any Other Items
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.12 MB
BOQ_331879.xls
BOQ • 0.31 MB
retender1of79.pdf
Tender Documents • 0.13 MB
cltrcess.pdf
Tender Documents • 0.43 MB
gstletter.pdf
Tender Documents • 0.32 MB
Download all tender documents and submit your bid