Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Not Admitted-Fee/PreQual/Technical RZ 128 A DHARAMPURA EXTENSION NAJAFGARH NAJAFGARH SOUTH WEST DELHI DELHI 110043 | WEST DELHI | DELHI | 110043 | Not Admitted-Fee/PreQual/Technical Others-OFFLINE ELIGIBILITY CREDENTIALS SUBMITTED BY THE FIRM ARE NOT AS PER NIT CONDITIONS, HENCE DISQUALIFIED |
Tender Value
Refer Docs
EMD Value
₹11,342
Closing Date
2 Apr 2022, 12:00 pmClosed
EXECUTIVE ENGINEER (ELECT.)
BSNL ELECTRICAL DIVISION-II, EASTERN COURT, JANPATH, NEW DELHI-110001
Repairing replacement and servicing of Split and Window AC Units and accessories of the offices under ESD Atul Grove Road and Residence of Sr. Officers of BSNL under the jurisdiction of BSNL Electrical Division II, New Delhi. Ch. to R M of AC Units
2022_BSNL_111252_1
29/NIT/E-Tender/2021-22/ED-II
Open Tender
Electrical Works
Item Rate
275 days
NEW DELHI
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
A.O.(Cash) o/o CGM BSNL, NTR, New Delhi
₹11,342
6 Apr 2022
25 Mar 2022
6 Apr 2022
25 Mar 2022
2 Apr 2022
25 Mar 2022
Dismantling 1.5TR/2TR window AC unit along with accessories and keeping all the dismantled items at desired location as per the directions of engineer in charge etc as required.
Dismantling 1.5TR/2TR Split AC unit along with refrigerant pipe lines, power cable and other accessories and keeping all the dismantled items at desired location as per the directions of engineer in charge etc as required.
ITC of 1.5/ 2.0 TR Split AC units at desired location, i/c fixing of refrigerant piping with insulation, drain pipe, flexible covering, power connections, testing, commissioning etc. complete as reqd.
1.5/2.0 TR Split A.C. Units
Installation of 1.5/2TR window type A.C. in the existing window i/c modification and fixing suitable wooden frame, loading unloading etc complete as reqd
Servicing of following capacity Window / Split AC / water cooler Units including washing & cleaning of filters, complete unit i.e evaporator unit, condensor unit i/c oiling, greasing of motors, testing, commissioning etc. complete as reqd.
1.5/2.0 TR Window/ Split A.C. Units & water cooler
Repairing & Testing of 1.5/2.0 TR Capacity Split AC Units, flushing the system, pressure testing with Nitrogen gas holding the pressure for 24 hours, vaccumising, removal of leakage in Indoor unit & out door unit including supply & charging of refrigerant gas (R-22) and oiling, greasing of motors, testing commissioning etc. complete as reqd.
Supply and topping up of refrigerant gas (R-22) in existing 1.5/2.0 TR capacity Split AC units, i/c tracing the leakage if any and rectfying the same, refinishing of refrigerant pipes, joints, testing & commissioning of A C unit etc. complete as reqd.
Replacement of following faulty motor with new copper wounded motor suitable for operation on single phase 230 V, A C supply in the existing Split/Window AC unit i/c removal of faulty motor, making electrical connections, testing, commissioning etc. complete as reqd. (M/s Crompton, Ashu or as per manufacturer recommendation) NOTE:- The motor shall be guaranteed for One Year
1/8 HP Condenser Fan Motor
1/4 HP Condenser Fan Motor/water cooler condensing fan motor
1/35 HP Indoor Unit Fan Motor
1/8 HP Double Shaft Fan/Blower Motor
Replacement of following defective/ unserviceable compressor in the existing Window / Split AC units with following new compressor suitable for operation on single phase, 50 Hz A C Supply i/c removal and re-installation of defective compressor, refrigerant piping & nut bolts of foundation, electrical connection and making connection with existing refrigerant pipe lines, brazing, electrical wire/ cable terminations, making joints (wherever required), testing, commissioning etc. complete as reqd. (NOTE:- Original Invoice and Test Certificate of the compressor shall be submitted.)
1.5 TR Capacity Rotary Sealed Compressor (M/s Hitachi/ LG/ Voltas)
2.0 TR Capacity Rotary Sealed Compressor (M/s Hitachi/ LG/ Voltas)
1.5 TR Capacity Reciprocating Hermetically Sealed Compressor (M/s Hitachi/ Daikin / LG/ Voltas/Emerson)
2.0 TR Capacity Reciprocating Hermitically Sealed Compressor (M/s Hitachi/ Voltas / LG/Emerson)
S/Fixing, pre-fabricated M S Frame made out of 35x35x5 mm thk M S angle stand for 1.5/ 2.0 TR Split AC condenser i/c 2 coats of paint, grouting/ fixing on floor etc. as required.
Replacement of existing faulty/unseriviceable 1.5 TR Indoor Units of Split AC Units by supplying new 1.5 TR Indoor Unit, suitable for operation on 230 V AC supply, complete with blower, cooling coil, filters, controls & all accessories and remote control, etc. complete as reqd. (Make : M/S Hitachi/ Blue Star/Carrier/Voltas make)
Replacement of condesnse coil of existing outdoor units of 1.5/2.0 TR split AC unit with new copper coil i/c removing the old coil nut bolt installing the new coil brazing testing commissioning etc complete as reqd.
Replacement of cooling coil 1.5/2.0 TR split AC unit i/c removong the old coil nut bolt fixing the new coil refrigerant piping brzing connetion testing commissioning etc as reqd.
Providing and fixing of 3mm thick ply wood in the existing window i/c cutting & fixing with the help of screws etc. complete as required.
Replacement /Fixing of following items in existing 1.5/2.0 TR capacity Split AC unit suitable for operation on Single phase, 240 Volt, AC Supply, testing, commissioning etc. complete as reqd.
Running capacitor 45 mfd/ 50+5 mfd
Starting Capacitor (120/150 mfd)
Copper wiring kit
Condensor Fan Blade (Transparent PVC/ Metallic)
Thermostat (Danfoss or Renutrol)
PCB repairing for remote control of A C unit
SITC of new PCB for remote control of AC unit
Supply/ Fixing of following Remote Hand Set with enclosure
i) Hitachi
iii) Gujral
Supply/ Fixing of 3 Pin 20 Amp, 240 Volt AC Industrial Top
S/Fixing 20 mm dia PVC drain pipe in recess or on surface for drainage of split AC units i/c connections etc complete as reqd.
S/Fixing PVC flexible pipe to cover the refrigerant pipes and power cables in the existing wall/on surface/ M S Tray with saddles, screws including S/F clamps etc. as required.
50 mm Dia
S/Fixing of following size 1.1 KV Grade PVC insulated copper conductor flexible cable in the existing M.S. Tray/Surface/Wall including S/F saddles, screws, thimbles i/c making connections, testing etc. complete as required.
3 Core 2.5 Sqmm
Pdg. & installing following size 22 Gauge of copper refrigerant pipe along with insulation including cutting bending, jointing, brazing , testing and commissioning etc as required.
1/4 inch size nominal dia
5/8 inch size nominal dia
Supplying and fixing of wall mounted relay operated line Voltage Stabilizer suitable to work for incoming main from 150 to 270 Volts, Output Voltage between 195 to 245 Volts of 4 KVA with High and Low Voltage cut-off and Time Delay Relay etc. complete as required. (M/S Bluebird/ Logicstat/Microtek make).
Repairing of existing faulty 4KVA/5KVA Voltage Stabilizer installead for window/split AC Units i/c replacement of faulty/burnt components such as PCB, Transformer, Voltmeter, TDR Switch etc., connections, testing etc. complete as reqd.
SCOPE OF WORK: 1. No material shall be supplied by the department. 2. Nothing extra shall be paid on account of cartage. Suitable arrangement should be made by the firm to attend the complaint within 2 Hours after receiving the complaint. For this purpose the contractor shall have to provide minimum 1 No. Skilled between 09:00 AM to 06:30 PM at BSNL ED-II, Eastern Court, Janpath, New Delhi-110001 (If more man power is required at any stage, same shall be provided by the Agency without any extra cost) from Monday to Saturday. Necessary arrangement should be made by the firm for attending the complaint throughout 24 hours. The Contractor should quote their rates accordingly. Note:- 1. The GST / other Input Tax Credit (ITC) taxes shall be quoted by the firm as applicable as per latest amendments of GST Rules. 2. The contractor shall provide correct tariff heads & other details to enable BSNL claim Input Tax Credit. 3. Servicing Scrap items will be credited to the firm. The rate may be quoted accordingly. 4. Bidder must mandatorily quote for all GST components (CGST, SGST, and IGST) as required. 5. If annual maintenance contract charges are required to be quoted as per SOW, basic charges should be shown in column 4 & the Goods and Service Tax (GST) in column 7 to 12. 6. The bidder who submits the offer with concessional Goods and Service Tax (GST) shall submit the proof of applicable concessional GST. In case the Concessional GST is not creditable to BSNL it should be included in the price of the goods/services. 7. In case, dealer is registered under compounding scheme or any rule/notification where the BSNL is not eligible for input tax credit then the bidder should not disclose any amount in column 7 to12 & 14. 8. % age Rate of FF & Packing should be shown of basic unit price excluding all taxes & charges (i.e. as %age of col.4). 9. The FF & packing amount quoted shall not be subject to change after bid evaluation /ordering on account of change of copper, lead base price, change in duties & taxes of item etc. 10. Bidder must mandatorily mention HSN & SAC numbers. 11. Evaluation of bids: - The evaluation and comparison of responsive bids shall be done on the basis of Net cost to BSNL on the prices of the goods & Services (i.e. complete work) offered along with all applicable Taxes, packing Forwarding Freight & Insurance charges etc. exclusive of GST. Declaration by Bidder: 1. We hereby declare that in quoting the above prices, we have taken into account the entire credit on inputs available under the GST Act introduced w.e.f. 1 July 2017 and further extended on more items till date. 2. We hereby certify that HSN/SAC shown in column 17 are correct & credit of GST for the amount shown in column 14 above are admissible as per GST Laws. Name of bidder: Seal of Company:
STAR ELECTRIC WORKS
kashyap electricalsd
R.K.DIESEL SERVICE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .