Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.5 LAccepted-AOC CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹38.7 L+₹81,790.02 (2.16%)Rejected-AOC | L2 | Rejected-AOC Not being lowest | |
| 3 | L3₹44.0 L+₹6.1 L (16.2%)Rejected-AOC JAISALMER | JAISALMER | RAJASTHAN | 342310 | L3 | Rejected-AOC Not being lowest | |
| 4 | L4₹45.0 L+₹7.1 L (18.8%)Rejected-AOC 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | RAJASTHAN | 334001 | L4 | Rejected-AOC Not being lowest | |
| 5 | L5₹45.6 L+₹7.7 L (20.4%)Rejected-AOC | L5 | Rejected-AOC Not being lowest |
Tender Value
₹45.9 L
EMD Value
₹91,800
Closing Date
23 Mar 2022, 2:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer -345001
SPECIAL REPAIR TO BLDG NO. P-99 (ORS LIVING LINE) AND BLDG NO. P-9, P-10 , P-11 AND P-12 AT SANGAR AT MIL STN JAISALMER
2022_MES_510616_1
8169/21-22/E8
Open Tender
Civil Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹91,800
Yes
4 Apr 2022
25 Feb 2022
25 Mar 2022
25 Feb 2022
23 Mar 2022
9 Mar 2022
Amount
Demoiliton of stone slabs and tiles of any description or thickness in foors, aprons etc complete all as specified & directed by Engineer-in-charge.
M&L Granite (of any type) tile 16 to 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified & directed by Engineer-in-charge.
M&L Granite (of any type) tile 16 to 20mm thick machine cut,in skirting/dado laid over cement screed bed and jointed with cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified & directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified & directed by Engineer-in-charge.
M&L for non skid ceramic coloured tiles of size 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, as in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6 complete all as specified & directed by Engineer-in-charge.
S&F glazed ceramic coloured tiles of size 350 x 250mm x 7mm / 450mmx350mmx7mm thick on vertical surface such as skirting, dados, risers to steps etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 10mm thick backing coat in CM (1:4) complete all as specified and directed by Engineer-in-charge.
M&L light shade, vitrified tiles, 10mm thick (minimum), (square/ rectangular polished, area of each tiles not exceeding 0.36 sqm (including 600mmx600mm size), in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM (1:6) complete all as specified & directed by Engineer-in-charge.
M&L vitrified tiles of light shade, 10mm thick (minimum) (square/ rectangular) polished area of each tiles equal to or not exceeding 0.36 sqm (including 600mmx600mm size), in skirting/dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour tiles laid over and including 10mm thick backing coat in CM (1:4) complete all as specified and directed by Engineer-in-charge.
S&F in repair soap dish stanless steel to walls complete all as specified & directed by Engineer-in-charge.
S&F in repair 100 mm size cast iron floor trap, with grating including jointing to waste pipe fixed in cement conrete (1:2:4) type B-1 complete all as specified & directed by Engineer-in-charge.
S&F in repair 15 mm bore, bib tap, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge.
S&F in repair 15 mm pillar taps fancy type, cast copper alloy with capstan heads, chromium plated, screed down high pressure, with or without lettered 'Hot; or 'cold' with long screwed shanks and fly nut, screwed for iron pipe and fixed, complete all as specified & directed by Engineer-in-charge.
S&F in repair tubular towel rail brass chromium plated, 20mm dia, D type 60cm long between flanges complete all as directed by Engineer-in-Charge.
S&F in repair, vitreous china wash basin white, flat back of size 550 x 400 mm including waste fittings, brass, chromium plated, coupling, waste pipe, brackets including cutting for and pinning in ends of brackets errect stand, fixing waste pipe complete all as specified & directed by Engineer-in-charge.
Taking up or down steel tubing and connections of following size complete all as specified & directed by Engineer-in-charge :-
(a) 15 mm bore
(b) 20 mm bore
S&F GI tubing (ISI) marked) medium grade with all fitting and fixed complete to wall ceiling or laid in floors of following sized :-
(a) 15 mm bore
(b) 20 mm bore
S&F in repair, Vitreous china urinals with urinal spreader, Half stall (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing complete all as specified & directed by Engineer-in-charge.
S & F in repair Vitreous china wash down water closet pan (Pedestal pattern), white (EWC) with necessary P/S Trap and including jet spray and seat cover complete all as specified & directed by Engineer-in-charge.
S&F in repair vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete all as specified & directed by Engineer-in-charge.
S&F in repair, 10 ltrs capacity PVC valve less, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets, flush pipe of 32 mm dia & PVC connection 15mm size, 450 mm long with PTMT nuts complete all as specified & directed by Engineer-in-charge.
S&F in repair PVC connection 15mm size with PTMT nuts and polythene washers of 450mm length complete all as specified & directed by Engineer-in-charge. Make : Prayag (Symet)
Taking down shutter of any description exe 1 sqm but N.exe 2 sqm and fixing after necessary welding of hinges to the frame complete all as specified & directed by Engineer-in-charge. (Note :- Fixing/welding of hinges will be measured separately)
Taking down chowkhat exe 1.5 sqm but exc 4 sqm each with shutter (without taking off shutter from the frames) complete all as specified & directed by Engineer-in-charge.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified & directed by Engineer-in-charge.
S&F 150 mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified & directed by Engineer-in-charge.
S&F 150 mm long Aluminium handles, cast type, anodised complete all as specified & directed by Engineer-in-charge.
S&F, 100mm size, butt hinges, medium weight, cold rolled mild steel including necessary welding if required all as specified & directed by Engineer-in-charge.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified & directed by Engineer-in-charge.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
Dismantling boarding of any description fixed in any position fixed with screws complete all as specified & directed by Engineer-in-charge.
S & F 18/19mm thick pre-laminated particle board, exterior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination alround 6mm thick teak fillets fixed in kitchen CB or pelmet complete all as specified & directed by Engineer-in-charge.
S&F 2nd class hard wood plain fillets square, rectangular or triangular in section, clean sawn, secured with nails or brads, cross sectional area exceeding 3 Sqcm and not exceeding 6 Sqcm complete all as specified & directed by Engineer-in-charge.
S & F 40mm width of flaps (when open) continuous (piano) hinges, mild steel bright finish or electroganised fiwed to wooden or angke iron frame complete all as specified & directed by Engineer-in-charge.
S&F 100 mm size hasp and staple, safety type, aluminium anodized with mild steel hinge pin including bolt to hinge plate and fixed with screws /fixed in repairs complete all as specified & directed by Engineer-in-charge.
S&F in repair 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified & directed by Engineer-in-charge.
S&F in repair stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mmx460mm with bowl size 410mm x 330mm x 160mm complete all as specified & directed by Engineer-in-charge.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified & directed by Engineer-in-charge.
M&L for rendering 15 mm thick plaster in cement mortar (1:6) on fair faces of brick work or concrete surfaces of walls and finishing the surface even and smooth without using extra cement all as specified and directed by Engineer-in-charge.
M&L for rendering 10 mm thick plaster in cement mortar (1:6) on fair faces of brick work or concrete surfaces of walls and finishing the surface even and smooth without using extra cement all as specified and directed by Engineer-in-charge.
M&L for rendering 15mm thick in cement mortar (1:4) in two layer (First coat 10 mm thick and second 5 mm thick) using water proofing compound @ 3% by weight of cement and finishing the surface even and fair without using extra cement all as specified & directed by Engineer-in-charge. (Note :- WPC will be measured and paid separetly).
M&L for rendering 5 mm thick plaster in cement mortar (1:4) on concrete surfaces of ceiling and finishing the surface even and smooth without using extra cement all as specified and directed by Engineer-in-charge.
M&L for prepration of new plaster surfaces and apply one coat of alkali resistant primer and treating with two coat of distemper complete all as specified and directed by Engineer-in-charge.
M&L for preparing new plastered or unplastered surfaces and apply three coats of white wash on ceiling all as specified & directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of walls and apply two coats of cement base paint over one coat of primer complete all as directed by Engineer-in-charge.
M&L for preparation of old decorated plastered/unplasterd surfaces of ceiling and apply one coat of white wash complete all as specified and as directed by Engineer-in-charge.
M&L for Complete removal of the existing treatment on walls scrapping and washing including making good to the surfaces and apply one coat of primer and treating with two coat of distemper complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old decorated plastered surfaces of walls and apply one coat of cement base paint complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth and apply one coat of synthetic enamel paint complete all as directed by Engineering in charge.
M&L for preparation of old painted wooden surfaces of any description not other wise described over 10 cm width or girth and apply one coat of synthetic enamel paint complete all as directed by Engineer-in-Charge.
S& F in repair of galvanized mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanized wire staples fixed complete all as specified & directed by Engineer-in-charge.
Hacking out old broken glass (any thickness, size quality or description) from wood /steel frame glazed with oil putty or fixed with beads and S&F plain sheet glass of 3 mm thick ordinary quality and glazing with oil putty and clips in squares not exceeding 0.50 Sqm in each pane ccomplete all as specified & directed by Engineer-in-charge.
Welding in repairs exc 2.5cm but not exceeding 5cm in length (thickness of metal to be welded not exc 6mm ) including cleaning preparing the surface and holding the member in true position complete all as specified and directed by Engineer in charge.
Taking down old steel window/ventilators of any description not otherwise specified and in any position complete all as specified & directed by Engineer-in-charge.
S&F steel ventilators with top hung shutters fitted with box type hinges including MS peg stays, MS handle and glazing bars dovetailed or welded for receiving glass including painting with one shop coat of zinc chromate primer,and cutting holes in wall for fixing the window lugs in PCC 1:2:4 type B1 using 20mm graded aggregate and making good the disturbed surfaces in CM (1:3) and applying two coats existing wall finishes to match with existing colour complete all as specified & directed by Engineer-in-charge. Note : The rates quoted are inclusive of making good all the disturbed surfaces to match with the adjoining surfaces and necessary scaffolding etc up to 4th floor.
Supply only integrated water proofing compound complete all as directed by Engr-in-charge.
Demolition of stone/ boulder masonry and built in cement mortar including all quoins arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles and removal unserviceable materials all as specified & directed by Engineer-in-charge.
M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified & directed by Engineer-in-charge.
M&L sand stone slabs 5cm thick in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4. complete all as specified & directed by Engineer-in-charge.
S&F in repair Single action spring hinge mild steel with steel wire springs stove enamelled black 100mm long including taking down of shutter and refixing in same opening, easing complete all as specified & directed by Engineer-in-charge.
Taking down all loose plaster and concrete if any in RCC columns, Chajjas, beams,slabs or any other type of RCC members,removing all loose ruts/scale from reinforcement etc by using wire brushes ,sand paper or any other chemicals, applying a coat appoxy coating on old reinforcement, tying IRC fabric of size 75x75mm of 3mm dia and binding with mild steel wire annealed with exsting reinforcement and applying cment slurry uniformaly to exposed surfaces and gunniting using CM 1:3 avg thickness of gunniting not less then 30mm and finishing the surfaces with 10mm thick rendering in CM 1:4 finished even and smooth with out using extra cement and removing the debris from the site complete all as specified & directed by Engineer-in-charge.
Providing and fixing additional steel bar in various structural elements like column, beams and Slab etc. including drilling, bending and fixing the bars tying with preleft binding wires etc. complete Steel provided on the basis of 1% of volume of concrete .Anchoring reinforcement bar in exisiting RCC member in holes of minimum 10d depth for 8 to 12 mm dia complete all as specified & directed by Engineer-in-charge. Note : Anchoring reinforcement bars in existing RCC members will be measured and paid separetaly.
Flush cutting of RCC chajjas, fins with reinforcement up to 150 mm depth by norms of Rcc mechanical cutting machine, all as specified.
Demolition wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets and frame work complete all as specified & directed by Engineer-in-charge.
S&F anodised aluminium snap grid frame work 600x600mm for false ceiling and hangers 6mm dia, GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fastener 12.5mm dia 40mm long complete all as specified and directed by Engineer-in-charge. Note :- Main tee, cross tee shall be 35x25x1.5mm & 25x25x1.5mm respectively. Angle at end all along the walls shall be 40x25x2mm.
M&L for Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified & directed by Engineer-in-charge.
S&F in repair 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed by Engineer-in-charge.
S&F in repair 110 mm bore PVC (SWR) bends/shoes any radius complete all as specified & directed by Engineer-in-charge.
S&F in repair 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed by Engineer-in-charge.
S&F in repair 75 mm bore PVC (SWR) bends/shoes any radius complete all as specified & directed by Engineer-in-charge.
S&F in repair Swivel shower rose 75mm size with arm 195mm long with bend of 45 degree with flange of PTMT any colour fixed complete all as specified & directed by Engineer-in-charge.
S&F in repair cast iron nahani trap of 75 mm dia with grating including jointing to waste pipe fixed in cement concrete type B 1 (1:2:4) complete all as specified & directed by Engineer-in-charge.
S&F in repairs 75mm Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified & directed by Engineer-in-charge.
M & L for the surfaces which are to receive the coating or treatment, must be free from oil, laitance, grease, wax, dirt or any other form of foreign material adhering on it before the waterproofing job started. Dust free the surface, including removing of existing treatment/ old felt / loose plaster / concrete etc. and repair with polymer mortar by adding bonding agent (SBR). Repairing of slab, parapet wall junction, cracks and other large blowholes by open in “V” shapes & filling by polymer mortar or putty followed by fiber mash tape with SBR in conjunction with cement complete all as specified & directed by Engineer-in-charge.(Make: CICO LATEX SBR/Nitobond/BASF Master Emaco SBR2)
CEMENTITIOUS ELASTOMERIC SLURRY COAT: M & L for water proofing treatment on roofs of slabs by complete removal/taking down of existing treatement, by applying acrylic based polymer modified cementitious elastomeric flexible composite coating system consisting of applying: First coat applying with CICO TAPECRETE-P151 or equivalent in FOSROC/STP/SIKA/BASF, mixed with neat fresh cement in the ratio of 1:1 by weight after dust free and moist the surface. Laying second layer of Fiber glass cloth of 45 GSM when the first layer is still green. Overlaps of joints of fiber cloth should not be less than 10 cm. Applying final layer of cementitious elastomeric flexible composite coating system. The whole terrace so finished shall be flooded with water for a minimum period of 24 hours for curing and for final test. “All above operations to be done in order by the manufacturer's authorised applicator only.
Dismantling water tanks and removing to store (exc500 and not exc 1000 ltr cap) complete all as specified & directed by Engineer-in-Charge.
S&F 1000 ltrs capacity white colour three layer rotational moulded polythene water storage tank (Cylinderical vertical with closed top) hoisted and fixed included 15mm float ball in postion complete all as specified & directed by Engineer-in-Charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Removing excavated soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge.
Taking down carefully copper/ aluminium point wiring (light, fan socket or power) complete including PVC Casing Capping/conduit, fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc and making good disturbed surface of walls, floors etc to match with existing specification complete all as specified and directed by Engineer-in-charge. Note :- Unserviceable material obtained from taking down shall be issued under Schedule of credit.
Taking down the existing unserviceable main switch /cut out /DBs of any type/capacity/description as existing at site including MCBs any type and capacity making good the disturbed surface to match with the existing finishes complete all as specified & directed by Engineer-in-Charge.
Taking down the existing unserviceable sub main wiring of any type /description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified & directed by Engineer-in-Charge.
Taking down MCB distribution boards with incoming and outgoing controls any make, any capacity after disconnecting complete all as specified & directed by Engineer-in-Charge.
Taking down ceiling fan/Exhaust fan cealing cable end ,dismantaling blades and removing fan and blades to store complete all as specified & directed by Engineer-in-Charge.
M& L for painting of ceiling fan/exhuast fan complete in situ with synthetic enamel paint by using mechanical spraying including filling cavity with filler one coat after cleaning all dust etc complete all as specified & directed by Engineer-in-Charge.
Hanging only ceiling fan/Exhaust fan (M.D Supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified & directed by Engineer-in-Charge.
Taking down the existing light fitting from ceiling and refixing the same complete all as specified & directed by Engineer-in-Charge.
Taking down light fitting any type any watt complete all as specified & directed by Engineer-in-Charge.
M&L Point wiring used approved colour coding as per IS (Red, Black and Green) for single phase circuits), with multi-stranded copper conductor 1.5 sqmm nominal cross -sectional area, single core, PVC insulated and unsheated FRLS cable 1100 volts grade, ISI 694 marked with valid CML No. in and including medium grade, PVC concealed conduit MMS, ISI marked of dia not less than 20 mm and conduit accessories conceled in wall/roof/floor etc, ISI marked with valid CML No. (IS-9537 - 1983 for conduits and IS : 3419 - 1976 for conduit accessories) with terminated to suitable for mounting modular type switches, socket fan regulator etc PVC insulated multistanded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- Note : Modular switch and socket shall be measured and paid separately.
(a) One light point controlled by one switch.
(b) One Ceiling /Exhaust fan point controlled by one switch.
(c) One 2/3 pin socket outlet 6 amp controlled by one switch on the same board with other switches.
(d) One 2/3 pin socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item No 90.00 above but pint wiring with 4.00 sqmm single core multi stranded copper conductor PVC insulated and unsheathed (FRLS) cable 1100 volts grade and 4.00 Sqmm PVC insulated and unsheated (FRLS) cable 1100 volts grade with multi stranded copper conductor as earth wire for 15/16 Amps multi porpose socket combination point on independent board.Note : Modular switch and socket shall be measured and paid separately.
S& F finished mounting Modular Metal Flush/Sunken Box of suitable size of following Sizes:-
(a) 1 Module
(b) 2 Module
(c ) 3 Modules
(d) 4 Modules
(e) 6 Modules
(f) 8 Modules
(g) 12 Modules
S&F Modular white cover plate with frame innner and outer plates for following sizes:-
(a) 1 Module
(b) 2 Module
(c ) 3 Modules
(d) 4 Modules
(e) 6 Modules
(f) 8 Modules
(g) 12 Modules
S&F modular switch one way 6A, 1 module complete all as specified & directed by Engineer-in-Charge.
S&F modular socket 6A-2/3 pin combined 2 module complete all as specified & directed by Engineer-in-Charge.
S&F modular switch socket combined 6A/16A , 6 pin, 3 module complete all as specified & directed by Engineer-in-Charge.
S&F modular fan regulator 5 step ,2 module complete all as specified & directed by Engineer-in-Charge.
S&F Ceiling rose, three terminals PVC/polycorbonate, isolated body complete all as specified & directed by Engineer-in-Charge.
S&F vertical DBs TPN 4 way 415 V double door powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 250 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required, suitable for TP/FP MCCB as incomer with MCCB 160 A as outgoing complete all as specified & directed by Engineer-in-Charge.
S&F vertical DBs TPN 4 way 415 V double door powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required, suitable for TP/FP MCCB as incomer with MCCB 100A and with provision of SP/TP MCB's as outgoing MCCB FP 100, KA complete all as specified & directed by Engineer-in-Charge.
S&F for MCB DB TPN 4 way double door IP 43 complete perewired including Bus bar etc suitable for operation on 415 volt 50 Hz AC supply including necessary provision for inserting the DB's in wall by cutting the brick/stone masonary etc and making good of distured surface to match with existing colour of wall complete all as specified & directed by Engineer-in-Charge.
S & F for MCB DB SPN 8 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-Charge.
S & F for MCB DB SPN 4 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-Charge.
Supply and fixing 415 V 16 KA 'C' curve moulded case circuit breker (MCCBs) of 100 A ,4 pole and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified & directed by Engineer-in-Charge.
Supply and fixing 415 V 10 KA 'C' curve miniature circuit breker (MCB) of TPN 63 A and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified & directed by Engineer-in-Charge.
Supply and fixing MCB's single pole and neutral 32 Amp, 240 Volts,10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-Charge.
Supply and fixing MCB's single pole and neutral 40 Amp to 63 Amps, 240 Volts,10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-Charge.
Supply and fixing MCB's single pole 10 Amps to 32 Amps, 240 Volts,10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-Charge.
M & L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 4.00 Sqmm (FRLS) in concealed conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 4.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engr-In-Charge. (Note :- Two runs of 4.00 Sqmm cable & one run of 4.00 Sqmm cable as earth wire and one run of PVC Conduit shall be measured & paid as one unit length.)
M& L for submain wiring with approved colour code /as per IS (Red, black & Green for single phase ) circuit with two single core PVC insulated cable with multistandered copper conductor are of 6.00 Sqmm (FRLS) in suitable concealed condit size not less than 20 mm dia incluuding one run of PVC insulated multistranded copper conductor nominal cross sectional area of 6.00 Sqmm (FRLS) of continuous earth wire green in colour complete all as specified & directed by Engineer-in-Charge. (Note :- Two run of 6.00 sqmm cable & one run of 6.00 Sqmm cable as earth wire and one run of PVC Conduit shall be measured & paid as one unit length.)
M& L for submain wiring with approved colour code /as per IS (Red, black & Green for three phase ) circuit with four single core PVC insulated cable with multistandered copper conductor are of 10.00 Sqmm (FRLS) in suitable concealed condit size not less than 20 mm dia incluuding two run of PVC insulated multistranded copper conductor nominal cross sectional area of 10.00 Sqmm (FRLS) of continuous earth wire green in colour complete all as specified & directed by Engineer-in-Charge. (Note :- Four run of 10.00 sqmm cable & two run of 10.00 Sqmm cable as earth wire and one run of PVC Conduit shall be measured & paid as one unit length.)
Supply and fixing of recessed mounted down lighter with extruded aluminium frame with high bright LED,idealy suited for low ceiling areas Brilliance 36watt LED 2700/4300 6000K, ceiling cutout 2ft x 2ft complete all as specified & directed by Engineer-in-Charge.
S & F surface and wall mounted LED tube light along with fixture, 4 ft, 22 W, extruded aluminium housing provided for efficient heat disspation with polycarbonate ,operating voltage 240 V, 50 HZ, AC supply and operating tempureture 0 to 50 C, power factor >0.9, lumen output > 2000 and provision of new 3 core multistanded copper conductor of size 23/0.193 from ceiling rose to fitting with white colour flexible pipe complete all as specified & directed by Engineer-in-Charge.
S & F in repair of LED tube light fitting 10 watt tube LED Neutral white in colour, 600 mm in length wall mounted LED batten,extruded aluminium heat shink provided for efficient heat dissipation & integrated electronic driver,optic diffused type ENDURA LINER NEO including all electric connection with whilte flexible cord 1.50 Sqmm 3 core as required complete all as specified & directed by Engineer-in-Charge.
Supply and fixing of building security light fitting LED 30 Watt IP 66 IK 07 pressure dia cast aluminium housing with high efficient LED as lihjting souce and PC cover having TOP opening sepreate drive compartment and connecting complete all as specified & directed by Engineer-in-Charge. (Make Havells cat pot No .EDDURAPEARLSL30WLED757SASYTOPCMP or as equivalent from list of makes)
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground levl connected to galvanized iron strip 25x4 mm dia as earthing lead up to Panel /DB BOX as per site requirement by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including test point terminal cover the earhing hole by PCC chamber and GI cover and testing on completion complete all as specified & directed by Engineer-in-Charge.
[i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
M&L Earthing Test point terminal block made of gun metal or phosphours bronze size 75x75x25mm drilled and screwed including 3 nos 8 mm dia 25 mm long hex,head screw complete all as specified & directed by Engineer-in-Charge.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chasees or buried in ground or drwan in conduit/pipe or fixed to DBs or any other indicated situation for loop earthing with galvanised iron strip of 25x4 mm size complete all as specified & directed by Engineer-in-Charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified including taking down existing once complete all as specified & directed by Engineer-in-Charge.
M& L Point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.6 mm with 3 mm thick phenolic laminated white sheet cover for mounting of Piano Type switches, sockets, fan regulators complete for the following :-
(a) One light point controlled by one switch.
(b) One Ceiling /Exaust fan point controlled by one switch.
(c) One socket outlet 6 amp controlled by one switch on the same board with other switches.
(d) One socket outlet 6 amp controlled by one switch on indepdendent board.
M& L Point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 4.00 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.00 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.6 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting for one 16 amp socket outlet modular type for controlled by one switch on independent board complete all as specified & directed by Engineer-in-Charge.
S&F switch piano flush button single pole one way 5/6 amp complete all as specified & directed by Engineer-in-Charge.
S&F switch piano flush button single pole one way 16 amp complete all as specified & directed by Engineer-in-Charge.
S&F socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete all as specified & directed by Engineer-in-Charge.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete all as specified & directed by Engineer-in-Charge.
S&F hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete all as specified & directed by Engineer-in-Charge.
S& F in repair bracket of GI pipe medium grade of 40mm dia ,1.2 meter in length clamps made of FI 40 mm x 6mm incl nuts, bolts & washers, painting complete all as specified & directed by Engineer-in-Charge.
S&F LED bulkhead fitting 10/12 watt IP 66 & IK 09 with pressure diecast aluminum housing & polycarbonate diffuser duly prewired for connection with flexible multi stranded copper conductor cable as required complete all as specified & directed by Engineer-in-Charge.
S&F angle holder, insulated polycabonate body with back plate complete all as specified & directed by Engineer-in-Charge.
Supply & Fix LED Bulb 9/10 Watt complete all as specified & directed by Engineer-in-Charge.
Fixing only ceiling/exhaust fan after servicing grasing change of bearing if reqd ,including making serviceable and noise free in all respect and connecting up including provn of cable from ceiling rose or connector to fan complete all as specified & directed by Engineer-in-Charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground levl connected to galvanized Strip 32X6mm dia as earthing lead up to Panel /DB BOX as per site requirement by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including test point terminal cover the earhing hole by PCC chamber and PCC cover and testing on completion complete all as specified & directed by Engineer-in-Charge.
[i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm 3 ½ Core complete all as specified and directed by Engineer-in-charge.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 Core complete all as specified and directed by Engineer-in-charge.
M&L for sand cushioning to underground PVC/XLPE cable with tibba sand and punning to provide required cover complete all as specified & directed by Engineer-in-charge. (Note :- For the purpose of payment, punned thickness of sand cushioning shall only measured).
Supplying and laying Jodhpur stone quarry faced stone slab cover 25 to 30 cm in width, 50 to 60 cm long and 40 to 50 mm thick, laid dry and abutting each other with gap between adjacent slab not exceeding 10 mm over under ground cables for protection complete all as specified and directed by Engineer-in-charge.
S&F steel water tubing (ISI marked) light grade galvanised, 50mm bore (ISI Marked) laid in trenches, as in cable protection complete all as specified and directed by Engineer-in-charge.
S&F steel water tubing (ISI marked) light grade galvanised, 40mm bore (ISI Marked) laid in trenches, as in cable protection complete all as specified and directed by Engineer-in-charge.
M&L for road cutting for laying of GI pipe for cable protection including returning, filling in trenches after laying of pipe and making good the top 200mm thick with PCC (1:2:4) type B-2 (40mm graded stone aggregate) and removing surplus soil to a distance n.exc. 50m complete digging after laying of pipe line / cable making good the surface complete all as specified and directed by Enginner-in-charge. Note :- GI pipe will be measured and paid separately).
AMBEY MAA CONSTRUCTION COMPANY
S K TRADER
M/S VISHNOI ENTERPRISES
Leelashah Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .