Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹2.4 L+₹43,444 (21.7%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹2.5 L+₹52,797 (26.4%)Rejected-Finance HNO 365 STREET NO 12 TALAB TILLO JAMMU RISHI TRADING CO TALAB TILLO ROAD OPP FRIENDS LANE JAMMU JAMMU KASHMIR 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L3 | Rejected-Finance 3RD LOWEST |
Tender Value
Refer Docs
EMD Value
₹2,000
Closing Date
9 Mar 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER
ELECTRICITY URBAN DISTRIBUTION CIRCLE, BUNGLOW NO.-9, OLD POWER HOUSE COLONY, RAILWAY STATION ROAD, GORAKHPUR
THE WORK AGAINST SANCTIONED PACKAGE 146/2020-21 and 148/2020-21
2021_PVVNV_559075_1
78/EUDC(G)/2020-21
Open Tender
Electrical Works
Lump-sum
30 days
AREA OF EUDC GKP
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SUPERINTENDING ENGINEER EUDC
₹2,000
13 May 2021
24 Feb 2021
10 Mar 2021
24 Feb 2021
9 Mar 2021
24 Feb 2021
180 days
Amount
fo|qr uxjh; forj.k [k.M&izFke] xksj[kiqj ds vUrxZr tek ;kstuk ys[kk'kh"kZ esa Lohd`r iSdst la[;k 146@2020&21 ¼vkbZ0,0,l0@ih0lh0,l0 dksfpax ls.Vj] ukeZy ifjlj] xksj[kiqj esa 20 fd0ok0 ds fo|qrhdj.k dk dk;Z½ ,oa fo|qr uxjh; forj.k [k.M&prqFkZ] xksj[kiqj ds vUrxZr Lohd`r iSdst la[;k 148@2020&21 ¼xq: Jh xksj{kukFk bULVhV~;wV vkWQ esfMdy lkbal] lksucjlk] xksj[kiqj ds fo|qrhdj.k dk dk;Z½ ds dk;ksZ dks lseh VuZdh vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k%&
Loading, unloading and safe carriage of following materials from Store Centre, Gorakhpur to JE dump Store and JE dump Store to work site with proper stacking :-
11 KV XLPE 3x70 Sq.mm.
Jointing Kit for 11 KV XLPE 3x70 sq.mm.
T/F11/0.4kv 63 KVA
S.T Pole 11mt. long
11 KV droper channel
11 KV disc insulater with fitting
11 KV top channel
11 KV S/S angle
11 KV pin insulator with pin
ACSR Weasel conductor
Earthing complete
11 KV TPMO SET
Stay Set Complete
11 KV PPMC (50/5 A)
11 KV Electronic TVM
11 KV CT PT Metering pole mounting unit 50/5A
The excavation of 2 nos. foundation pit of size 750mmX450mm and having depth of 1/6th of the full length of the pole. Fabrication & erection of double Pole with fixing of necessary clamps & accessories (Top Channel, Dropper Angle etc.) as per required. All required materials such as Holding clamp/STP clamp, Nuts & Bolts off size etc will be provided by the contractor. Grouting of Pole in cc 1:4:8 (Cement, sand & 40 mm brick ballast), Grouting will be done in the block of size 450x450 mm x depth upto ground level and backfilling of pits with mud completely and leveling etc (Material provided by Contractor). Making plinth around Pole height 300 mm above ground level with top 100 mm is kept tapered so that no rainwater gets accumulated on the top. All work will be done as per RESPO norms & relevent IS Specification.
Erection and grouting of stay in CC ratio 1:4:8 of Cement, Sand and Stone Ballast including cost of grouting material with nozelling and binding of stay wire (Complete work)
Painting of Pole with Aluminium paint & Red oxide paint provided by contractor
Earthing of ST Pole by MS earthing Rod & 6 SWG earthing Wire as per RESPO norms.
Laying of parallel 11 KV 3X70 Sq.mm. XLPE cable (1X40+70x2=180 mtr.) by HDD method as per RESPO Norms.
Laying of parallel 11 KV 3X70 Sq.mm. XLPE cable(70x2=140 mtr.) by digging of trench of size 800 mm wide 1250 mm deep and boxing with brick, sand, stone slab 600X450X50 mm, width between 11 KV cable 600 mm. (Other Necessary Materials excluding 11 KV 3X70 Sq.mm. XLPE provided by Contractor). Work will be done as per provision of IS 1255:1983
Errection of Cable Jointing Kit & Hoisting of cable on double pole using G.I. Pipe 4"dia 3 Mtr. long (G.I. Pipe 4" Dia and other Necessary Materials excluding 11 KV XLPE Cable 3X70 mm² provided by Contractor)
Errection of Cable Jointing Kit
Fabrication, errection, commissioning & Testing of T/F on Double Pole with all accessories including make its LT and HT connection. All necessary materials such as Holding clamp, Al.Lugs (Confirming to IS 8309), Z Clamp, Nuts & Bolts will be supplied by the Contractor.
Chemical earthing of Transformer (Body+Neutral) as per IS Code 3043 - 1987 specification
Errection of TPMO
Errection of PPMC (50/5 A) along with 2 nos. 11 KV Electronic TVM Meter
Earthing of PPMC
Errection of 11 KV CT PT Metering pole mounting unit 50/5A
M/S jai ambey traders
Rishi Trading Co.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .