Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹34.0 L+₹42,453.10 (1.27%)Rejected-Finance B XI 746 STREET NO 6 BHARAT NAGAR BARNALA 148101 | BARNALA | BARNALA | PUNJAB | 148101 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹36.9 L+₹3.3 L (9.96%)Rejected-Finance 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹38.5 L+₹5.0 L (14.8%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹40.2 L+₹6.7 L (20.0%)Rejected-Finance ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L5 | Rejected-Finance Being L5 |
Tender Value
Refer Docs
EMD Value
₹78,640
Closing Date
26 Sept 2023, 6:00 pmClosed
Sh Himanshu, IDSE
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender documents
2023_MES_616525_1
GE(S)/PAT/T-36/N/2023-24
Open Tender
Civil Works
Item Rate
210 days
Mil Stn Nabha
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (South) Patiala
₹78,640
Yes
31 Oct 2023
31 Aug 2023
3 Oct 2023
31 Aug 2023
26 Sept 2023
13 Sept 2023
31 Aug 2023 - 6 Sept 2023
Amount
Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc.complete all as specified and directed by Engr-in-charge
M & L for 15mm thick ( in two layers of 10mm and 5mm thickness) cement pastering in cement mortar 1:4 and mixig the water proofing compound as per manufactures instructions on brick or concrete surface of wall finished fair and even without using extra cement complete all as specified and directed by Engr-in-charge Note : Water proofing compound shall be measured and paid saparately under item .
M&L 10mm thick cement plastering in cement mortar CM 1:6 finishing the surface even and smooth without using extra cement complete all as specified and directed by Engr-in-charge
Complete removal of existing treatment of any type/description such as distempering work ,internal emulsion etc from internal/external surfaces of walls & ceiling with mechanical means/grinder including removal of material from site complete all as specified and directed by Engr-in-charge
M&L Preparation of new plastered or unplastered surfaces of walls/ existing treatment surface wall, two coats of cement base paint complete all as specified and directed by Engr-in-charge.
M&L for applying acrylic thick wall care putty on internal/external surfaces of walls/ceilings/soffits(thickness vary from1.5to2.5mm as required for desired smoothness and levelling of surfaces in two or more layers)by us ingready made wall careputty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed by Engr-in-charge
M&L Applying 02 coats of interior emulsion paint (white shade) @ 10 sq.m/litre/2 coats to ceiling surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed by Engr-in-charge
Supply only integral water proofing compound ISI marked.
M&L Rendering 5mm thick in cement mortar 1:3 as on concrete surfaces in ceiling finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge
M&L Preparation of new plastered or unplastered surfaces applying three coat of white wash on ceiling surfaces complete all as specified and directed by Engr-in-charge.
M&L Preparing old plastered surfaces of ceilings and applying one coat of white wash. complete all as specified and directed by Engr-in-charge
Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed by Engr-in-charge
All as per srl item No 12 hereinbefore but n. exc 1.5 sqm each.
S&F Powder coated Pressed steel frames made of MS sheet of 1.25 mm thickness for doors with single rebate including necessary fixing lugs, hinges, lock strike plate, hold fasts ,filling PCC (1:3:6 Co) in chowkhats , PCC 1:2:4 B1 hold fast blocks etc., complete as specified,size 105x 60mm including cutting holes and making good reqd to shape for hold fast blocks for new frame complete all as specified and directed by Engr-in-charge. ( Note :- Disturbed portion of existing floor /wall / tile / plaster etc duing fixing of chowkhats shall be repaired to match with existing finish .Cost of the same will be included in this item )
S&F Powder coated Pressed steel frames made of MS sheet of 1.25 mm thickness for doors with double rebate including necessary fixing lugs, hinges, lock strike plate, hold fasts ,filling PCC (1:3:6 Co) in chowkhats , PCC 1:2:4 B1 hold fast blocks etc., complete as specified,size 125x 60mm including cutting holes and making good reqd to shape for hold fast blocks for new frame complete all as specified and directed by Engr-in-charge. ( Note :- Disturbed portion of existing floor /wall / tile / plaster etc duing fixing of chowkhats shall be repaired to match with existing finish .Cost of the same will be included in this item )
S&F 35mm thick plain framed (Factory made) Panelled shutters of 2nd class HW with lock rail and panels of 9mm B.W.P commercial ply including beading on the facing side of shutters as per SSR Part I clause No 8.17.5. The size of rail and stiles as per IS 1003 (Part I) kiln seasoned and chemically pressure treated complete all as specified and directed by Engr-in-charge
S&F 35mm 2nd class hard wood Glazed and skeleton shutters, 2nd class hard wood open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed by Engr-in-charge
S&F Mild steel barrel tower bolt 200mm long stove enamelled black with bright bolt and fixed complete all as specified and directed by Engr-in-charge
S&F Mild steel sliding door bolt of size 250mm , stove enamelled black with bright bolt not less than 16mm dia, with and including a minimum of 6 bolts and nuts, complete all as specified and directed by Engr-in-charge
S&F MS pressed handles of size 125mm oval type stove enamelled black.complete all as specified and directed by Engr-in-charge
S&F Mild steel butt hinges of size 100mm medium weight cold rolled.complete all as specified and directed by Engr-in-charge
S&F Mild steel butt hinges of size 50mm medium weight cold rolled.complete all as specified and directed by Engr-in-charge
S&F 300 mm long MS rat tail pattern spring hinge including roller and roller plate, complete all as specified and directed by Engr-in-charge
S&F Factory made steel windows box type using ERW hollow 'P' section comprising double frame for glaged and gauged skelton shutters jointed interally with flat iron 40x4mm complete including grill of 8mm square bar, fixed horrizontally @ 10cm centre to centre, hinges,handle tower bolts,lugs etc all as shown on drawing noTD-219(c) sheet 1/3 to 3/3 and TD-220 (c) sheet 1/3 to 3/3 as applicable complete Note;- (i)for the purpose of measurement& payment double shuttre with frame shall be considered as one unit. (ii) Glaging ,, wire mesh and glass, measured and paid for separately
S&F power coated 50 microns extruded aluminium ventilators with 50 micron coating of frame of 63.5x38.10x1.29 mm including 5mm thick frosted glass in lower 60% portion of shutters and stainless steel wire gauge 0.36mm dia and 1.4 aperture in upper 40% portion of shutters and stainless including EPDM gasket to render the glazing, air and water tight etc & aluminium beeds 20mm size complete fixed in all respect complete all as specified and directed by Engr-in-charge
S&F Sheet glass ordinary quality 4 mm thick and glazing with oil puttly or wooden beads in square not exceeding 0.5 sqm in each pane complete all as specified and directed by Engr-in-charge
S & F Wire netting of galvanised steel wire 1.40mm dia and size of mesh 25mm fixed with wooden beds tinned tacks of wire staples complete all as specified and directed by Engr-in-charge
Preparing of new surface of wood and wood based material of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel pain and one coat of pink primer complete all as specified and directed by Engr-in-charge
M&L for preparing surfaces of any description over 10 cm girth or width, not otherwise described and applying two coats of synthetic enamel paint over a coat of Red oxide on new surfaces of steel or iron, complete all as specified and directed by Engr-in-charge
M&L one coat of synthetic enamel paint to old steel surfaces including preparation in all complete all as specified and directed by Engr-in-charge
Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level), complete all as specified and directed by Engr-in-charge
M&L for ceramic floor tiles of minimum size 600X600 mm 8 to 10mm thick in flooring etc set and jointed in neat cement lurry and pointed in white cement to match over and including 20mm thick screed bed in CM (1:4) laid in complete all as specified and directed by Engr-in-charge.
M&L Machine cut Kota stone slab flooring 20mm (+2mm) thick laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 as base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over 25mm thick cement concrete type B-0 (12.5mm graded aggregate) complete all as specified and directed by Engr-in-charge
All as per item No 15 here in before on vertical surfaces as in skirting/dado of size as required at site but excluding 25mm thick PCC all as directed.complete all as specified and directed by Engr-in-charge
S&F mild steel chromium plated 20mm curtain rod with fixing brackets, stops rollerss complete incl fixing brackets, stops etc all as specified & directed as in repair . (For the purpose of mesurement and payment running length of curtain rod only shall be considered.)complete all as specified and directed by Engr-in-charge
Dismantling of brick tiles or terracing tiles single layar on roofs complete all as specified and directed by Engr-in-charge
Demolation of mud puska and removing on roof any thickness as directed.
M&L PCC 1:3:6, type B-0 using 12.5 mm graded stone aggregates as in padding over roof ,minimum thickness at khurra as 50mm maintain a slope of 1:100 using water proofing compound make even and smooth without using extra cement complete all as specified and directed by Engr-in-charge
M&L PCC 1:2:4, type B-0 using 12.5 mm graded stone aggregates as in roof kerbs or mud stops/ coping etc including weathering slightly rounded or chamferred complete all as specified and directed by Engr-in-charge
M&L for the following roof treatment. (a) Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3mm thick weight not less than 3.60kg/Sqm water proofing membrane, black finished reinforced with non woven polyester matt, fixed as per manufacturer’s instructions complete all as specified and directed by Engr-in-charge. (b) Applying one coat of bituminous primer confirming to IS-3384 @ 0.3 Ltr/Sqm. (c) Applying one coat of aluminium paint over APP membrane @ 0.50 litres per Sqm all as specified and directed. (d) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg per square metre including cleaning the surfaces all as directed and specified.
Repair to RCC sunshades, Chajjas, Balconies, Columns, bands, beams, ceilings and similar RCC work at any position/height by dismantling loose/disintegrated portion and dubbing out with Cement Concrete 1:1½:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stitching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcher with cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with10 mm thick plastering in CM 1:4 finished even and fair without using extra cement including cutting grooves in brick /concrete wall and preparation of surfaces to receive finishes complete all as specified and directed.
S&F PVC ( SWR) rain water pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engr-in- Charge
M&L Hard core of broken bricks of gauge n exc. 63 mm spread and levelled in layers n exc.15cm thick, watered and rammed to a true surface complete all as specified and directed by Engr-in-charge
M&L PCC (1:3:6), 50mm thick as in PCC path/ plinth protection.finished the surfaces even and smooth with out using extra cement
M&L Machine pressed precast concrete inter locking paver block any shape and size made of M-35 grade concrete (with grey cement and no pigment) of 60mm thickness with 6mm top layer of anti abrasive material laid over 25mm thick (compacted) fine sieved sand complete all as specified and directed by Engr-in-charge
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base of flooring.complete all as specified and directed by Engr-in-charge
M&L for chequered cement concrete tiles with grey cement and pigment 20cmX 20cmX25mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, over 15 mm thick cement screed bedding layer in cem,ent mortar 1:6, complete all as specified and directed by Engr-in-charge
S & F mild steel peg set of 6 fixed to wall with steel screws complete all as specified and directed by Engr-in-charge
Demolition of reinforced cement concrete of any description (Reinforecement cut as required to facilitate demolition ) complete all as specified and directed by Engr-in-charge
Demolition of brick work built in cement mortar.complete all as specified and directed by Engr-in-charge
M&L for brick work in cement mortar (1:4) using sub class 'B' bricks staight or curved on plan exc 6.0 m mean raidus complete all as specified and directed by Engr-in-charge
M&L fo 25mm thick PCC (1:2:4) type B-0 using 12.50 mm graded crushed stone aggregates in complete all as specified and directed.as in floor base complete all as specified and directed by Engr-in-charge
M&L Coloured glazed ceramic tiles ( 600 mm x 100mm) x 7mm thick as in vertical surfaces such as skirtings, dados etc jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 10mm thick back coat in CM (1:6), in complete all as specified and directed by Engr-in-charge
Dismantling of asbestos cement sheets [corrugated, semi-corrugated, etc] in roof coverings complete all as specified and directed by Engr-in-charge
S & F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed to self tapping screws complete all as specified and directed by Engr-in-charge
S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in ridges, roof covering/clading to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-charge
S&F MS hollow rectangular/square/circular tubes/pipes of Fe410-W(Gde-E-250) Grade as in frame work for roof/rafter/purline/chajja/trusses/columns/struts etc and like similar items etc. complete all as specified and directed by Engr-in-charge
S&F for plates /cleats/connplates of Fe410-W(Gde-E-250)quality A etc for frame work complete all as specified and directed by Engr-in-charge
Dismantling of wrought timber truss scantling 40Sq.cm and over in section framed work, provided for complete all as specified and directed by Engr-in-charge
Dismantling of wrought timber scantling as in fillets, post rafter , purlins etc under 40Sq.cm in section framed work, provided for complete all as specified and directed by Engr-in-charge
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed by Engr-in-charge
M&L anodised aluminium snap grid false ceiling of grid size 605x605mm consisting of aluminium main and "T' sections of size 25x35x1.5mm thick and wall angles of size 25x 25x 1.5 mm thick suspended with GI wire suspenders of 6mm dia of suitable length and 8-10 mm thick gypsum board, 60x60 cm size fixed with staples on snap grid complete all as specified and directed by Engr-in-charge
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp, holders brackets, bulk head, mirror light fittings etc removing material for taking credit ( credit shall be recovered as per credit Sch attached) and also making good disturbed surfaces of wall, floors etc all as specified and as directed by the Engineer-in-Charge.
M&L for point wiring with 1.50 sqmm in copper conductor cable ( multistrand) FRLS single core PVC insulated cable in and including PVC concealed conduit ( ISI Marked) of heavy duly with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLS controlled by one switch for one light/fan/sockets point/ all as specified and directed by Engr-in-Charge in ceiling Portion surface conduit wiring to be done. Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. (iii) Necessity cutting chasing where ever required shall be part of job & making good the disturbed surfaces shall be part of job.
All as per item No 2 above, but for one 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 2 above, but for one 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per serial item No 2 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement of modular switch 1 way, 6 Amps, 1 module completeall as specified.
S & F in replacement modular type, Bell push 1 way, 6 Amps, 1 module complete all as specified.Make : Indoasian/Anchor/Havells
S & F in replacement modular type, switch 1 way, 16 Amps, 1 module complete all as specified. Make : Legrand/ Roma/ORIS L&T/Siemens/Wood
S & F in replacement modular type, socket 5 pin 6 Amps, 2 module complete all as specified. Make : Legrand/ Roma/ORIS L&T/Siemens
S & F in replacement modular socket 5 pin 6/16 Amps, combination type 2 module complete all as specified. Make : Legrand/ Roma/ORIS L&T/Siemens/Wood
S & F in replacement modular Fan regulator step type, 120 watts, 1 module complete all as specified. Make : Legrand/ Roma/ORIS/Havells
M & L for ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed by the Engineer-in-Charge.
S & F in replacement Vertical load line type VTPN DB, 4 way 415 V, double door as per IS - 8623, IP-54 protection, universal mounting with suitable capacity copper bus bar with nuetral bus bar, earth bar and cable ties for cable management, top and bottom removable gland plate suitable for accomodate MCCB TPN 100 Amp as incomer and TP&SP MCCB/MCBs as outgoing complete & making necessary electrical connection for incoming and outgoing cables, with copper lugs, crimpped with crimping tool complete all as specified and directed. Note: (i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. (ii) The disturbed surface shall be match with existing shall be part of job.
S&F in replacement of existing MCCB TPN, 63 Amps, 415 volts, 16 KA complete fixing in DBs including proper thimbles connections all as specified and directed.
S & F in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 8 way double door type with 200 amp rated bus bar as per IS - 8623, IP-54 protection. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The disturbed surface shall be match with existing shall be part of job.
S & F in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 12 way double door type with 200 amp rated bus bar as per IS - 8623, IP-54 protection. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The disturbed surface shall be match with existing shall be part of job.
S & F in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp, in the MCB DB Complete with connection testing and commissioning complete all as specifed and directed
S & F in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) SPN current carrying capacity 6 to 32 Amp, in the MCB DB Complete with connection testing and commissioning Complete all as specifed and directed
S & F in replacement of FTL with new techonlgy LED having high efficiency of capacity LED 20 Watt, 4 feet long, FIXT ELITE PRIDE PLUS 20 W 6500K, Cool Day Light (CDL) LHEXBLP7PN1W020. Make -Havells. incl necessary electric conection complete all as specified.
S & F in replacement of LED 10 Watt, 2 feet long, Cool day light with NEO Batten10 W 6500K having high efficiency Cat No. LHEXACP7IN1W010. Make -Havells. incl necessary electric conection complete all as specified.
S & F in replacement of Recess mounted LED Cool day luminaire of 12 W LED 3000 K round shape and separate replaceable electronic driver, suitable for gridd celling/POP Ceiling Cutout cutout size dia 160 mm including fitment of LED Light in false ceiling/POP ceiling by cutout making, fit in existing cutout and making good the existing ceiling lamp & driver.
S & F in replacement of lamp holder, PVC/ polycarbonate type with back plate suitable for upto 20 watt bulb for batten fitting, including plastic square board of required size complete all as specified.
S & F in replacement of LED Lamp 12 Watt.
S & F in replacement LED light fitting 1x9W/1X10W bulkhead luminaires 230 Volts including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified by Engr-in-Charge.
S & F in replacemnt new generation energy saving and environmental friendly long life LED building security light 1x25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with suitable dia light grade GI pipe bend to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed.
M&L for replacement of existing unserviceable earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I
S&F energy saving 3 star rating ceiling fan 1200mm sweep energy efficent as per latest specifications having service value more than 5.5 make: Havells or equivalent in Usha/ Bajaj and suspended from fan hook including electrically connecting with twisted three core PVC insulated unsheathed flexible cord of 0.75 Sqmm copper conductor from ceiling rose to ceiling fan.
S&F Metal body Wall mount Fan energy saving 3 star rating 450mm sweep energy efficent as per latest specifications having 230 Volts incl anchoring arrangement all as directed by Engr-in-Charge. Make: Havells, Bajaj or equivalent in Usha/ Bajaj
S & F in replacement of Call bell ding dong AC 230 volt single pole complete all as specified.
S & F in replacement LED post top fitting flat base type powder coated aluminium die cast and spun aluminium with clear diffuser of capacity 10 Watt, 3000 K including cost of warm white lamp and necessary electric conecction all as specified and directed by Engr-in-Charge .
S & F in replacement 1100 volts grade heavy duty XLPE insulated, armoured heavy duty electric cable with aluminium conductor cross-sectional area 25 Sq. mm, 4 core incl grouting into wall , connecting to DB/Panel with suitable size coppr thimbles, making good/mahing the surface of wall complete all as specified.
S & F in replacement 1100 volts grade heavy duty XLPE insulated, armoured heavy duty electric cable with aluminium conductor cross-sectional area 16 Sq. mm, 4 core incl grouting into wall , connecting to DB/Panel with suitable size coppr thimbles, making good/mahing the surface of wall complete all as specified.
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
Supply and laying well burnt sub class ‘B’ bricks. ( designated 75) locally available best quality laid dry in trenches for protection of underground cable all as specified and directed.
Material and labour for replacement of GI tubing light grade 50 mm bore for passing through cables under the floor, along the wall or along the pole complete all as specified and directed.
S & F in replacement of existing unserviceable Plug & Socket Box (sheet metal) with PVC Plug, SPN 20 Amps for Acs. Model No. - DHDPHSN020, Make-Havells/Indoasian.
M&L for Sub main wiring with 2 runs of single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 2x4 sqmm ( line conductor) & 1x4 sqmm ( earth conductor), 1100 volt grade drawing in & including heavy duty non metallic PVC conduit , ISI marked, incl accessories not less than 25 mm in dia & concealed in wall, roof etc including PVC insulated, FRLSH unsheathed single core multistranded copper conductor cable, green in colour as earth conductor including cutting charges for concealed conduit wiring etc and making good cutting not exceeding 10 cm grith complete all as specified and directed. Note: (i) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth . (ii) Connections of cables with MCBs or bus bars shall be done through brass/copper thimbles of appropriate size . (iii) Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only.
M&L for Sub main wiring with 2 runs of single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 2x6 sqmm ( line conductor) & 1x6 sqmm ( earth conductor), 1100 volt grade drawing in & including heavy duty non metallic PVC conduit , ISI marked, incl accessories not less than 25 mm in dia & concealed in wall, roof etc including PVC insulated, FRLSH unsheathed single core multistranded copper conductor cable, green in colour as earth conductor including cutting charges for concealed conduit wiring etc and making good cutting not exceeding 10 cm grith complete all as specified and directed. Note: (i) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth . (ii) Connections of cables with MCBs or bus bars shall be done through brass/copper thimbles of appropriate size . (iii) Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only.
Dismantling existing ceiling fan with hanging pipe, refixing the same with new locking pins, nut bolts etc, hanging down rod of suitable size & length (upto 1.5 mtr) below false ceiling duly painted all as directed by Engr-in-Charge. Note :- Cost of down road/pipe is included in the quoted rate of the schedule.
M/S RAJ KUMAR GUPTA
AGGARWAL & CO
m/s k.k. construction co.
NARINDER KUMAR SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .