Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC WZ 143 A 7A S 4 43 GALI NO 2 OLD MAHAVIR NAGAR NEW DELHI 110018 | WEST DELHI | DELHI | 110018 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹28.4 L+₹7.9 L (38.7%)Rejected-AOC | L2 | Rejected-AOC Not Being Lowest | |
| 3 | L3₹30.8 L+₹10.3 L (50.2%)Rejected-AOC PLOT NO 79 SIS PARK DICHAON ENCLAVE PP2914 NAJAFGARH SOUTH WEST DELHI NEW DELHI 110043 | WEST DELHI | DELHI | 110043 | L3 | Rejected-AOC Not Being Lowest | |
| 4 | L4₹33.4 L+₹12.9 L (62.9%)Rejected-AOC | L4 | Rejected-AOC Not Being Lowest | |
| 5 | L5₹34.1 L+₹13.6 L (66.4%)Rejected-AOC | L5 | Rejected-AOC Not Being Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
8 Jul 2024, 6:00 pmClosed
GE (CENTRAL) DELHI CANTT-10
GE (CENTRAL) DELHI CANTT-10
WELCOME MAINT AND PERIODICAL SERVICES ALONGWITH CERTAIN B/R WKS AND E/M WORKS OF HOUSE NO 1-150 AT DK-I, 202 CEDU, 1883 CER BTY, GE OFFICE, KANDHAR LINE AND TRANSIT OFFR ACCN IN THE AREA OF AGE B/R-I UNDER GE (CENTRAL) DELHI CANTT-10
2024_MES_658838_1
GE/C-20/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE (CENTRAL) DELHI CANTT-10
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE (CENTRAL) DELHI CANTT-10
₹1 L
Yes
10 Sept 2024
10 Jun 2024
10 Jul 2024
10 Jun 2024
8 Jul 2024
24 Jun 2024
10 Jun 2024 - 24 Jun 2024
Amount
Preparation of old decorated surface (plastered or unplastered) of walls incl cornices pillar etc by brooming down or steel wire brushing scraping down smoke root mould moss and efforesceent salts and treating oil and greasy spots as applicable and applying one coat of white wash on wall .
All as per item No 01 above but applying two coats of white wash.
All as per item No 01 above but applying one coat of white wash on ceiling.
All as per item No 01 but applying two coats white washing on ceiling.
M&L for Preparation of old painted surfaces of wood based surfaces of any description over 10 cms width or girth and applying one coat of synthetic enamel paint , complete all asspecified.
All as per item No 05 above but applying two coats of synthetic enamel paint .
Preparation of wire mesh surfaces by brushing and applying a coat of synthetic enamel paint on GI wire mesh complete (measured over all one side only).
M&L for Preparation of old painted surfaces of steel of any description over 10 cms width or girth and applying one coat of synthetic enamel paint , complete all as specified.
All as per item No 08 above but applying two coats of synthetic enamel paint.
Complete removal of existing old treatment on surface from walls with machenical scraper (machine) complete all as specified and directed.
M& L a coat of alkali resistant primerover alread prepred surface of walls complete all as specified and directed.
M& L for preparing the entire surface with applying 2-3 mm thick birla/ JK wall care putty on walls/ ceiling surface finished even and smooth complete all as specified and directed.
M& L for applying one coats of oil bound distemper on wall/Ceiling surface with roller brush complete all as specified and directed.
M& L for applying two coats of oil bound distemper on wall/Ceiling surface with roller brush complete all as specified and directed.
M&L preparation of old plastered surfaces of wall and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed
Complete removal exising treatment of old/ new surfaces of wall scrubbing by machenical scrapper (machine) with hard brushing ,brooming down or steel wire brushing scraping down smook root mould moss and efforescent salts and treating oil and greasy spots as applicable and washing with water and applying 2-3 mm birla wall care putty Two coats of weather proofing exterior acrylic emulsion paint of any make over one coat of primer from the same manufacturer white lime wash even and smooth with roller brush complete all as specified and directed.
Demolition of Brick work of stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles
M&L for brick work with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls with old size bricks, built in cement mortar 1:4, complete all as specified.
M&L for brick work with sub class 'B' brick straight or curved on plan exc 6 metre mean radius with old size bricks, built in cement mortar 1:6, complete all as specified.
All As per item no 19 before but except bricks.
Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces or other than fair faces of brick work or concrete surfaces firnished een and smooth without using extra cement up to hieght of four storey ,including scaffolding complete.
M&L for rendering 15mm thick in CM 1:6 on fair faces or other than fair faces of brick work or concrete surfaces of walls firnished even and smooth without using extra cement in multistorey building ,complete all as directed.
M&L for 5mm thick rendering in cement mortar 1:3 finished even and smoothe surface without using extra cement on ceiling, chajja in multy storey building etc complete all as specified.
M&L preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed.
Material and labour for preparation of new plastered surfaces as of walls and applying Two coats of weather proofing exterior acrylic emulsion paint over one coat of primer from the same manufacturer white lime wash complete all as specified and directed. Notes for item No 16 & 26:- (a) Rate quoted up to G+4 bldg including scaffolding. (b) The work shall be executed through authorised applicator. (c) The work shall be executed through authorised applicator of manufacturer only. (d) Authrised Applicator shall be approved by GE before starting of work. (e) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material. Engineer-in-Charge shall deface the original purchase vouchers. (f) MOU with authorized applicator will be submitted successful L1 bidder after opening of Financial Bid within a fixed time frame of 7 days otherwise tender will be cancelled (g) A guarantee amount of 5% of contract of work done for item No 16 & 26 of BOQ will be retained for 5 years of the completion of work.
M&L for new plaster surface two coat of oil bound destemper over 2mm thick of birla white putty including preparation of newly plastered surface etc all as specified.
Hacking out old broken glass of any thickness size quality or description frame wooden frames /Aluminium frame fixed with wooden beads/aluminium beads/steel window and M&L 3.5 mm thick sheet galss ordinary quality and glazing with wooden bead/aluminium beads, putty etc complete all as specified.
S & Fin repair 1000 ltr capacity three layer white colour rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling old water tank all as specified in SSR Part I.
S & F in repair 500 ltr capacity three layer white colour rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling old water tank all as specified in SSR Part I I(Make : Sintex/Rotex/Polywell).
Taking down chowkhat or frame not exceeding 1.5 Sqm each with shutter (without taking off shutter from the frame)
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded Complete all Specified and directed.
All as per Srl item No 32 above but without glazing bars
S&F for Chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165.
Demolition of cement concrete (Un reinforced) in ground floors n.exc 15cm thick (above or below grnd level) complete all as specified.
Dismantling floor, hearth or wall tiles including cement mortar concrete bedding amd removing rubbish off the premises complete all as specified and directed.
M&L 25mm thick cement concrete type B-O, 1:2:4 (12.5mm graded agg ) as in floors finished even and fair complete all as specified and directed.
M&L Non skid cerermic coloured tiles 300x300X 7 to 8 mm thick (Square/rectangular) area of each tile in neat cement slurry and pointed in white or coloured cement with pigment to match over 15mm thick screed bed in cement mortar (1:6).
All as per item No 38 above but as in skirting over rendering 10mm thick in cement mortar 1:4.
M&L Vitrified ceramic Light shade coloured tiles 600x600x 9-10mm thick square/rectungular polished area of each tile in floor etc set and jointed in neat cement sluarg and painted in white or coloured cement to match laid over 15mm thick screed bed of cm 1:6.
All as per item No 40 above but as in skirting over rendering 10mm thick in cement mortar 1:4.
M&L Glazed ceramic coloured tiles (600X300mm) x 7mm thick on vertical surfaces etc, set and jointed in neat cement slurry and pointed in white cement to match the shade of tile over 10mm thick rendering of in cement mortar 1:4.
Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame) complete all as specified.
Taking down chowkats or frames exc 4 Sqm but not exc. 6 sqm each with shutters (without taking off shutters from frames ), complete all as specified.
Taking down shutters of any desciption area exc 1.0 Sqm but n.exc 2.0 Sqm each and removing to or from store.
Supply and fixing factory made uPVC white colour Three track panels sliding door with fly proof S.S wire mesh (two Nos, glazed & one no. wire mesh panels) made of (big series) frame 116x45mm & sash 46x82mm both having wall thickness of 2.3+_ 0.2mm and single glazing bead/double glazing bead of appropriate dimension. (Area of door above 2.00sqm upto 5sqm comprising of upvc chamfbered frame, with in built roller track and sash extruded profiles duly reinforced woth 1.60+_ 0.2mm thick galvanised mild steel section maid from roll forming process of required length (shape & size according to upvc profile) Appropriate dimension oupvc extruted glazing beads, uPVC extruted interlock and uPVC extruded line sash adaptor (if required), EPDM gasket, wool pile, zinc alloy(white powder coated) handle with key on one side of extreme panels alongwith zinc plated mild steel multi point looking having tansmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required). stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120kg) GI fastners 100X8mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and dirtected by engineer-in charge. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sah extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be acceptable but no extra payment on this account shall be made.
M&L for Plain, solid, straight chowkats and frames made of 2nd class hard wood (sal), wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints, supplied and fixed,making good , complete all as specified and as directed by Engineer-in-Charge.
S&F for 32mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
M&L for 35 mm thick 2nd class hard wood glazed and skelton door shutter, factory made, open rebated and prepared to receive glass/guage etc. (without sash bar) edge of frames plain, chamfered or rounded, fitted with cut & mitred beads for securing glass/guage etc size of member as specified in SSR Part I Section 8 clause 20(a) and fixed to chowkat, complete all as specified.
S&F powder coated Anodiesed aluminium frame for partition, doors, windows, ventilators with one or more rebates incl. joining cleat for fixing etc. complete all as specified.
Anodised aluminium powder coated sliding windows, window shutters and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as locking system, suitable handle (1 no.) complete all as specified and as directed by Engineer-in- charge.
S&F powder coated Anodiesed aluminium door shutters, aluminium section weighing 0.55 Kg/m incl. necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each doors,Brass 2 lever mortice lock verticle type size 100mm, hinges, anodiesed aluminium snap beading screw with etc.
S&F solid PVC door Prelam frame of sixe 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening as per specification and drawing.
S&F factory made soilid panel PVC Door shutter 30mm thick (Stype) both side prelam clouor consisting of frame made out MS frame shall be covered with heat moulded plain coloured PVC 'C' channel having PVC sheet stripof 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail, & bottom rail; Panneling of both side prelam clouor PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification and drawing.
S&F 4.8 mm thick sheet glass, ordinary quality and glazing in Aluminium door with solar control files 50 micron in squares exc 0.5 Sqm each pane.
Supply and fixing PVC wall lining consisting of 5mm thick printed colour PVC sheet inclusive of solvent cement and fixing on PVC frame /Aluminium door at site etc complete all as specified and as directed by Engineer-in- charge.
S&F 150mm long extruded stainless steel handle fabricated type
S&F 100 mm long (size) butt hinges medium weight, cold rolled, mild steel, complete all as specified(Fixing included in item 43 here-in-before).
Supply only 100 mm long (size) butt hinges medium weight, cold rolled, mild steel, complete all as specified(Fixing included in item 43 here-in-before).
S&F for 150 mm size stainless steel barrel tower bolts of extruded section and fixed to shutter complete.
S&F for MS 300mm size, door spring Pencil type rat tail rod pattern springs including roller and roller plate complete.
S&F for 100 mm size long mortice lock vertical type ,4 levers with key in duplicate, brass body with brass two nos handle fixed in shutters with screw complete all as specified.
Supply&fix in repairs two legged aluminium floor door stopper with rubber shoe 140mm long complerte all as specified and directed by Engineer-in-Charge.
S&F for galvanized stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm dia fixed with stainless steel wire staples including beading complete all as specified and as directed .
M&L two coats of synthetic enamel painting on wooden surfaces not otherwise described over 10cm width or girth over a coat of pink primer inclding prepration of newly untreates surfaces complete all as specified and directed.
Taking up or down steel tubing 15mm bore and connections, including cleaning for refixing or removal to store and S&F 15mm GI tubes, medicum grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors.
All as per item No 66 above but 20 mm bore.
S & F in repair Harrison rails, stainless steel 18mm dia with fixing brackets, knobs, stops, rollers, wall to wall etc.complete all as specified and directed.
S&F in repairs PVC valve less, syphonic action type low level flushing cistern of capacity 10 Ltrs with inlet, ball valve, float and handle and fixed to IWC on existing brackets, fixed in repairs.
S&F chlorium plated shower roses with or without swivel join ts 100mm size incl fixingto steel pipe in repairs.
S&F in repair vitreous china wash basin with flat back, size 550 x 400mm, fixed on existing brackets incl 32mm bore CP waste coupling.
S&F in repair vitreous china Pedastal, for above mentioned item no. 78 complete all as specified and directed.
S&F in repairs CP bib taps 15mm dia cast copper alloy with crutch or half lever handle fixed in repairs.
S&F 15mm bore stop valve/angle valve cast copper alloy chromium plated fancy type screwed down, high pressure, with crutch or butter fly handles fixed in repairs.
All as per item No 75 above but concealed type with long shank and cup.
S&F in repairs viterous china squartting pan orrisa pattern , size 580x 440mm white, interged foot rest including connection to trap and to flush pipe, anti syphonic pipe etc complete making good to floor.
S&F viterous china ware wash down water closet pan (Pedestal Pattern) white including plastic seat and cover with MS CP hinges fixed in repairs.
S&F in repairs combined viterous china ware wall hanging wash down water closet pan (Pedestal Pattern) coloured and plastic seat and hydraulic cover with MS CP hinges, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe. Etc attached connected vitreous china valveless, syphonic action type, 06 ltrs capacity, low level flushing cistern, white with inlet, ball valve, float and handle.
S & F in repair toilet paper holder with flat recessed type stainless steel complete all as specified and directed.
S & F in repairs Chromium plated health faucet (hand spray) with 1mtr long PVC flexiable pipe 15mm bore and fixed to in position etc complete all as specified and directed.
S&F in repair super flush siphon for low level single or double action flushing cistern complete set (excluding float valve PVC handle) all as specificed and directed.
S&F in repairs cast copper alloy chromium plated fancy type single lever basin mixer .
S&F in repairs stainless steel sink with drainage board made out of 1.00mm thick sheet for kitchen or laboratory, with plug, waste pipe, washers incl. cantiliver cast iron brackets, connecting union etc overall size 915mm X 420mm with bowl size 410mm X 330mm X 160mm.
S&F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 485mm x 420mm bowl size 410mm x 3330mm x 160mm
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through Existing PVC conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box / M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:- complete all as specified and directed by Engineer in charge.
One light/fan point controlled by one way switch
One bell / buzzer point controlled by one bell push
One light point controlled by two Nos two way switches
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 87 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box / M S steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:- complete all as specified and directed by Engineer in charge.
One light/Exh fan point controlled by one way switch
One bell / buzzer point controlled by one bell push
One light point controlled by two Nos two way switches
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 89 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge.
Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 1 module / 2 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc including make good of disturbed surface complete all as specified and directed by Engineer in charge. Note: Switch,socket, regulator will be paid separately
Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 3 module / 4 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc including make good of disturbed surface complete all as specified and directed by Engineer in charge. Note-Switch,socket, regulator will be paid separately
Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 6 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc. including make good of disturbed surface complete all as specified and directed by Engineer in charge. Note-Switch,socket, regulator will be paid separately
Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 8 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc including make good of disturbed surface complete all as specified and directed by Engineer in charge. Note-Switch,socket, regulator will be paid separately
M&L in replacement switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement switch modular type 6 amp SP two way, 1 module complete all as specified and directed by Engineer in charge.
M&L in replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement modular stepped type electronic fan regulator 120W, 2 module all as specified and directed by Engineer in charge.
M&L in replacement switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement switch piano flush button type single pole Two way 6 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement bell push single pole 6 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement switch piano flush button type single pole 16 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer in charge.
M&L in replacement socket outlet 6 Amp flush button type complete all as specified and directed by Engineer in charge.
M&L in replacement regulator electronic switch/socket type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed.
M&L in replacement bell electric (dingdong) 230 volt, SP all complete all as specified and directed by Engineer in charge .
M/L in replacement insulated body, angle holder (metal ring) with back plate complete all as specified and directed by Engineer in charge.
S&F ceiling rose PVC/Polycarbonate type with three terminals complete all as specified and directed by Engineer in charge .
M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 20Amps complete with one single pole MCB 'C' series 10/20 A capacity complete all as specified and directed by Engineer in charge.
Supply and fix in replacement LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fixin replacement LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix in replacement LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S&F in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge .
Supply and fix in replacement surface ceiling mounted, LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S&F in replacement 35W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 110lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:65 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<10%, High and low protection along with a surge protection of 4 KV including provision of suitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed.
M & L in replacement for opening up the winding of ceiling fan 1200/1400 mm sweep any make any type and rewinding with super enamelled copper winding wire after inserting super enamelled insulating material binding it with insulating tape etc completely and varnishing well including drying completely. Replacement of worn out / unserviceable capacitor bearing , bush , safety pins, nuts, bolts, washers , rubber bush with ceiling fan clamp, cable PVC flexible 23/0076 and testing the ceiling fan after re-fixing of the blades to the entire satisfaction of Engineer-in-Charge.
Supply and Fixing in replacement LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge.
Supply and Fixing LED in replacement bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge.
Supply and fix in replacement MCB DP 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge.
Supply and fix in replacement MCB DP 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge.
Supply and fix in replacement MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge.
Supply and fixing in replacement Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
Supply and fixing in replacement Exhaust fan 300 mm sweep (steel Body) , 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
Supply and fix in replacement wall mounted fan 400mm, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system all as specified and directed.
S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed.
Supply and fix in repair Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed.
Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed.
Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed.
S&F in replacement plug top, 3 pin, 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge.
S&F in replacement socket 3 pin 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge .
S & F PVC Gang box surface type heavy duty suitable for single switch & socket 5 Amps complete all as specified and directed by Engineer in charge .
S & F PVC Gang box surface type heavy duty suitable for two switch & two socket 5 Amps complete all as specified and directed by Engineer in charge .
S & F Gang box surface type heavy duty suitasble for 15 Amps switch and socket complete all as specified and directed by Engineer in charge.
M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 4 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M&L in replacement copper cable flexible 2 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge.
Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed.
Supply only heating element of 2 KW any type with nut bolt washer complete all as directed.
Supply only heating element of 1.5 KW any type with nut bolt washer complete all as directed.
Supply only replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed.
Supply only replacement of capacitor 1.5 Mfd, 240 V complete all as specified and directed.
Schedule of Credit
POONAM ENTERPRISES
M/S Parmod Johar
Maninder Singh Lohia
ANSH VANSH CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .