REPAIR/REPLACEMENT OF ELECTRIC WIRING, ELECTRIC FITTINGS, FIXTURES, MCBs, MCCBs, DBs AND CONNECTED E/M ITEMS IN BOYS GIRLS YEP, PL LINE, OFFRS MESS, POTA CABINS, RVC, MT AREA AND PM RALLY AT DGNCC CAMP LINE UNDER GE (EAST) DELHI CANTT-10
2020_MES_376685_1
GE/DE-34/2020-2021
Open Tender
Civil Works
Item Rate
90 days
GE (East) Delhi Cantt-10
Class D Cat b i
8 documents required · 8 mandatory
₹500
GE (East) Delhi Cantt-10
₹56,000
Yes
20 Oct 2020
11 Sept 2020
14 Oct 2020
11 Sept 2020
12 Oct 2020
30 Sept 2020
11 Sept 2020 - 18 Sept 2020
Amount
Taking down carefully copper/ aluminum Point Wiring light/ fan/ bell/ socket/ power complete including conduit fittings and making good the disturbed surfaces of Walls/ floors/ ceiling complete all as specified & as directed by Engr- in- charge.
Point wiring with FRLS PVC insulated heat retardent stranded copper conductor cable through existing steel /PVC concealed conduit and existing CI/MS terminal boxes with new 3mm thick hylem sheet with screw,cup washers etc for fixing switch,socket, etc. including single core FRLS PVC copper conductor cables 1.5Sqmm and one run of 1.5Sqmm cable as earth continuity wire connected to common erath and earth dolly complete all as specified and as directed by the Engr-in- charge for the following:- (a) One light point or one fan point or bell point controlled by one switch SP, one way, 230 volts.
All as per description of Srl item No.- 2 here-in-before but One 3 pin socket outlet 5/6 Amps on same board, complete all as specified and as directed.
All as per description of Srl item No.- 2 here-in-before but One socket outlet 5/6 Amps on independent board, complete all as specified and as directed.
All as per description of Srl item No.- 2 here-in-before but for power socket 15/16 Amp with cable 2.5Sqmm for phase & neutral for earth 1.5Sqmm, complete all as specified and as directed.
Point wiring with FRLS PVC insulated heat retardent stranded copper conductor cable on PVC Casing/ Caping with FRLS PVC copper conductor cables 1.5Sqmm and one run of 1.5Sqmm cable as earth continuity wire, Provn of New 3mm thick hylam sheet with screw,cup washers etc for fixing with,socket, etc. complete all as specified and as directed by Engineer-in-Charge (phase neutral and earth wire shall be provided in strandard colour code R.Y.B for phase, black for neutral, green for earth wire :- (a) One light/fan point controlled by one, one way switch (Switches and sockets to be measured and paid separately under relavant items of Sch 'A')
All as per description of Srl item No.- 6 here-in-before but one 3 pin socket outlet 5 Amp on the same board with other switches, complete all as specified and as directed.
All as per description of Srl item No.- 6 here-in-before but independent socket 3 pin 5 Amp, complete all as specified and as directed.
All as per description of Srl item No.- 6 here-in-before but One socket outlet 15 amp independent but using 2.5Sqmm stranded copper conductor incl FRLS PVC insulated 1.5Sqmm earth to common earth and to earth dolly, complete all as specified and as directed.
Point wiring complete with 1.5Sqmm (nominal area) FRLS, PVC insulated un-sheathed and stranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 20mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers except conduit junction box (junction box will be of MS) including FRLS, PVC insulated unsheathed 1.5Sqmm copper earth wire, connecting to common earth dolly with and including Metal flush box of suitable size for fixing modular switches/sockets/fan regulator etc., with and including Modular cover plates of suitable size and making good surface as original by plastering, whitewash/colour and distemper etc complete all as directed for the following :- (a) One light/fan point controlled by one, one way switch. (Note : The cost of modular type Metal boxes and modular accessories like cover plates will be included in quoted rate.)
All as per description of Srl item No.- 10 here-in-before but One 3 pin 6 Amps socket outlet independentControlled by one switch, complete all as specified and as directed.
All as per description of Srl item No.- 10 here-in-before but for one 3 pin 6 Amps socket outlet on the same board with other switches, complete all as specified and as directed.
All as per description of Srl item No.- 10 here-in-before but 2.5Sqmm cable with 1.5Sqmm earth wire for piano type, complete all as specified and as directed.
Replacement of switch piano flush type 5 Amp SP one way, complete all as specified and as directed.
Replacement of switch piano flush type 5 Amp SP two way, complete all as specified and as directed.
Replacement of switch piano type 15 Amp SP one way, complete all as specified and as directed.
Replacement of socket outlet 2-in-1, 5 Amps flush type 3 pin 5 Amps multi purpose, complete all as specified and as directed.
Replacement of socket outlet 2 in 1 (multipurpose) 3 pin 5 and 15 Amp flush mounted type, complete all as specified and as directed.
Replacement of ceiling rose surface bakelite 65 x 50 mm with two to three terminals, complete all as specified and as directed.
Replacement of Modular switch 6 Amp, 1 way, 1 module size, complete all as specified and as directed.
Replacement of Modular switch 16 Amp, 1 way, 1 module size with indicator lamp, complete all as specified and as directed.
Replacement of Modular socket 6 Amp, 2/3 pin, shuttered type, 2 module size, complete all as specified and as directed.
Replacement of Modular socket 16 Amp mulipurpose shuttered type, 3 module size, complete all as specified and as directed.
Replacement of wall light (SK-1/Comet) complete fitting with 9 watt LED lamp with and including all electric connections, complete all as specified and as directed.
Sleek LED Mirror light 10/12 W diffuser, driver and making all electrical connections, complete all as specified and as directed.
Replacement of Recess mounting 2 feet x 2 feet square flat panel ultra slim scoop LED light 36 W cool white 5600-6000K, input voltage 110-240 volt, 50 Hz with driver/transformer ect suitable for AS/GB/POP ceiling incl making electric connections, complete all as specified and as directed.
Replacement of LED tube light fitting 4 feet suitable for 20/22 W LED T/L fitting complete for recess mounting and making all electric connections, complete all as specified and as directed.
Replacement of gate / garden light with and including cast aluminium spigot, spun aluminium canopy with clear acrylic cover,round 12" dia LED lamp 15 watt and other fixing accessories, complete all as specified and as directed.
Replacement of LED street light fitting 50 W LED 50 Hz,CRI less then 75,Lumens output 4320,IP 65 ingress Protection and Power factor > 0.9 complete with all accessories, fixtures & fittings, complete all as specified and as directed.
Replacement of LED street light fitting 40 W LED 50 Hz,CRI less then 75,Lumens output 4320,IP 65 ingress Protection and Power factor > 0.9 complete with all accessories, fixtures & fittings, complete all as specified and as directed.
Replacement of street light fitting bracket 1.5 mtr long made out of galvanised iron pipe of 40mm dia size light grade complete with nut, bolt washer etc inclusive of one prome coat, one uner coat and one finishing coat of silver paint, complete all as specified and as directed.
Replacement of LED bulbs 9W, B 22/E14/E27 90-300V AC-50 Hz, complete all as specified and as directed.
Replacement of LED Halogen light fitting 50 W, AC 230V, 50 Hz, complete all as specified and as directed.
Replacement of LED Dimmer light 400W, AC 230V, 50 Hz, acomplete all as specified and as directed.
Replacement of Halogen lamp -,500W, AC 230V, 50 Hz, complete all as specified and as directed.
Replacement of Halogen lamp -,1000 W, AC 230V, 50 Hz, complete all as specified and as directed.
Replacement of lamp holder bakelite insulated body with back plate suitable for batten fitting, complete all as specified and as directed.
Replacement of fan regulator stepped resistance type suitable for 1200/1400 mm sweep fan as per existing pattern, complete all as specified and as directed.
Replacement of flexible wire 23/.0076 three core, complete all as specified and as directed.
Replacement of MCB DB single phase & Neutral 2 Way with Single door type, flush mounting, complete all as specified and as directed.
Replacement of MCB DB single phase & Neutral 4 Way with double door type, flush mounting, complete all as specified and as directed.
Replacement of MCB DB single phase & Neutral 8 Way with double door type, flush mounting, complete all as specified and as directed.
Replacement of MCB DB single phase & Neutral 12 Way with double door type, flush mounting, complete all as specified and as directed.
Replacement of distribution board triple pole and neutral 4 way for inccorporation of MCCB 125 Amps as incommer and MCBs as out goings with metal door and IP-43 Protections, complete all as specified and as directed.
Replacement of distribution board triple pole and neutral 8 way for inccorporation of MCCB 125 Amps as incommer and MCBs as out goings with metal door and IP-43 Protections, complete all as specified and as directed.
Replacement of MCB SP 6 to 32 Amps,230V, 10 KA, complete all as specified and as directed.
Replacement of MCB SPN 40 Amps, 240 volts 10 KA, complete all as specified and as directed.
Replacement of MCB SPN 63 Amps 240 volts 16 KA, complete all as specified and as directed.
Replacement of MCB Isolator four pole 100 Amps 415 Volts, complete all as specified and as directed.
Replacement of isolator single pole and neutral for 63 amp 240 volts, complete all as specified and as directed.
Replacement of single pole and neutral metal clad sheet steel enclosures with 2 pin and earth plug and socket complete with MCB SP 32 Amps, complete all as specified and as directed.
Replacement of single pole and neutral metal clad sheet steel enclosures with 2 pin and earth plug and socket complete with MCB SP 20 Amps, complete all as specified and as directed.
Replacement of aluminum lugs bottle type upto 16 to 70 Sqmm size including crimping and taping in different colours as per colour code, complete all as specified and as directed.
Replacement of off load change over switch AC, 230 volts, 63 Amp, SP, side handle operated,heavy duty in sheet metal enclouser, complete all as specified and as directed.
Change over switch off load type AC, 415 volts, TPN 100 Amp ,side handle operated,heavy duty in sheet metal enclouser, complete all as specified and as directed.
Changer over switch off load type AC, 415 volts, TPN 200 Amp ,side handle operated,heavy duty in sheet metal enclouser, complete all as specified and as directed.
Replacement of any type of cable by FRLS PVC insulated single core with stranded copper cable of size 1.5 Sqmm in 2 run and 1.5 Sqmm one run for earth and drawing in existing conduit, complete all as specified and as directed.
Replacement of any type of cable by FRLS PVC insulated single core with stranded copper cable of size 2.5 Sqmm in 2 run and 1.5 Sqmm one run for earth and drawing in existing conduit, complete all as specified and as directed.
Replacement of any type of cable by FRLS PVC insulated single core with stranded copper cable of size 6 Sqmm in 2 run and 4.0 Sqmm one run for earth and drawing in existing conduit, complete all as specified and as directed.
Replacement of any type of cable by FRLS PVC insulated single core with stranded copper cable of size 4 Sqmm in 2 run and 2.5 Sqmm one run for earth and drawing in existing conduit, complete all as specified and as directed.
Replacement of any type of cable by FRLS PVC insulated single core with stranded copper cable of size 10 Sqmm in 2 run and 6.0 Sqmm one run for earth and drawing in existing conduit, complete all as specified and as directed.
Supplying & Laying in trenches in replacement of cable 6 sqmm 2 core 1100 volts grade armoured with aluminium conductor ISI marked, complete all as specified and as directed. (Note : GI pipe for cable protaction, sand cushioing and excavation are out of the scope of these items and shall be measured and paid respective items)
Supplying & Laying in trenches in replacement of cable 10 sqmm 2 core 1100 volts grade armoured with aluminium conductor ISI marked, complete all as specified and as directed. (Note : GI pipe for cable protaction, sand cushioing and excavation are out of the scope of these items and shall be measured and paid respective items)
Supply & Laid in trenches in replacement of LT UG XLPE cable 16 sqmm 2 core 1100 volts grade armoured with aluminium conductor ISI marked, complete all as specified and as directed. (Notre: GI pipe for cable protaction, sand cushioing and excavation are out of the scope of these items and shall be measured and paid respective items)
Supplying & Laying in trenches in replacement of LT UG XLPE cable 25 sqmm 4 core 1100 volts grade armoured with aluminium conductor ISI marked, complete all as specified and as directed. (Note : GI pipe for cable protaction, sand cushioing and excavation are out of the scope of these items and shall be measured and paid respective items)
Supplying & Laying in trenches in replacement of LT UG XLPE cable 35 sqmm 4 core 1100 volts grade armoured with aluminium conductor ISI marked, complete all as specified and as directed. (Note : GI pipe for cable protaction, sand cushioing and excavation are out of the scope of these items and shall be measured and paid respective items)
Excavation in trenches in loose/soft soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep and getting out including forming bottom surface for laying LT cable, complete all as specified and as directed.
Returning filling in soil including spreading, levelling, watering and well rammingin layers not exceeding 25 cm, complete all as specified and as directed.
Removing excavated soil not exceeding 50 mtr and depositing wheredirected at a level not exceeding 1.5 mtr above the starting point, complete all as specified and as directed.
Sand cushioning to under ground cable provided with layers of sand (8 cms deep before laying the cable and 15 cms deep after laying), complete all as specified and as directed.
Burnt bricks sub class- B for mechanical protection of cables, complete all as specified and as directed.
Replacement of Top plug 15 Amps incl all connections, complete all as specified and as directed.
Replacement of CP connections armoured type 20 mm size with PTMT nuts of length 600mm, complete all as specified and as directed.
Replacement of heating element 1.5 KW capacity ISI Marked for geyser of any type/Make and capacity including making necessary electric connection and testing the geyser, complete all as specified and as directed. (Note : The petty items such as nut, bolt, washer, clamps, gasket etc are deemed to be included in quoted rates).
Replacement of heating element 2.0 KW capacity ISI Marked for geyser of any type/Make and capacity including making necessary electric connection and testing the geyser, complete all as specified and as directed. (Note : The petty items such as nut, bolt, washer, clamps, gasket etc are deemed to be included in quoted rates).
Replacement of cable flexible 3 core 40 / 0.0076 copper in replacement, complete all as specified and as directed.
Taking down and provisioning Soldering and brazing to inner copper tank 50/25/35 ltrs with brass solder and refixing, complete all as specified and as directed.
Replacement of base plate assembly (confirming to ISI) complete for 50 ltrs capacity geyser including inlet, outlet and thermostat pipe with drain plug and screws for fixing the element including of clamps for holding the elements with nut, bolts & air release valve suitable for any type/make of geysers installed at site, complete all as specified and as directed.
Replacement of base plate assembly (confirming to ISI) complete for 25 ltrs capacity geyser including inlet, outlet and thermostat pipe with drain plug and screws for fixing the element including of clamps for holding the elements with nut, bolts & air release valve suitable for any type/make of geysers installed at site, complete all as specified and as directed.
Replacement of base plate assembly (confirming to ISI) complete for 35 ltrs capacity geyser including inlet, outlet and thermostat pipe with drain plug and screws for fixing the element including of clamps for holding the elements with nut, bolts & air release valve suitable for any type/make of geysers installed at site, complete all as specified and as directed.
Replacement of chromium plated copper connection pipe 18" long with two brass adopters and connecting up, complete all as specified and as directed.
Replacement of non return valve 15/20 mm dia (ISI Marked) and connecting up complete including GI Socket, elbow, bend etc., complete all as specified and as directed.
Replacement of safety valve/high pressure release valve (ISI Marked) with dead weight etc complete suitable for any makes/capacity/type of geysers installed at site all as directed.
Replacement of thermostat ISI Marked for geyser of any type/Make and capacity including making necessary electric connection and testing the geyser, complete all as specified and as directed.
Replacement of fan condenser 2.5 MFD, complete all as specified and as directed.
Rewinding of ceiling fan old/new model any size, 1200mm /1400mmsweep with super enamelled copper wire of required size as per existing gauge & pattern &varnishing including greasing/oiling and commissioning/testing to the entire satisfaction of Engr-in-charge, complete all as specified and as directed.
Rewinding of wall mounted fan old/new model any size, any sweep with super enamelled copper wire of required size as per existing gauge & pattern &varnishing including greasing/oiling and commissioning/testing to the entire satisfaction of Engr-in-charge, complete all as specified and as directed.
Rewinding of exhaust fan / Fresh air fan of any size and make (200mm to 300mm sweep) with super enamelled copper wire of required size duly varnishing including gressing/oiling and commissioning/testing to the entire satisfaction of Engineer-in-charge, complete all as specified and as directed.
Rewinding of exhaust fan / Fresh air fan of any size and make (375mm sweep) with super enamelled copper wire of required size duly varnishing including gressing/oiling and commissioning/testing to the entire satisfaction of Engineer-in-charge, complete all as specified and as directed.
Rewinding of exhaust fan / Fresh air fan of any size and make (450mm sweep) with super enamelled copper wire of required size duly varnishing including gressing/oiling and commissioning/testing to the entire satisfaction of Engineer-in-charge, complete all as specified and as directed.
Replacement of bearing/ bush gun metal suitable for 1200/1400mm sweep ceiling fan/wall mounted fan of any type including oiling greasing for proper running and testing as directed by Engr-in-charge, complete all as specified and as directed. (Note :Testing complete will be carried out in MES store yard).
Replacement of sheet Bakelite (Hylem) 3 mm thick including cutting of sheet for fixing switch/socket required including fixing of old switch/socket and making connection etc for the Sheet size 9" x 13", complete all as specified and as directed.
All as per description of Srl item No.- 92 here-in-before but Sheet size 8" x 10", complete all as specified and as directed.
All as per description of Srl item No.- 92 here-in-before but Sheet size 8" x 5", complete all as specified and as directed.
Replacement of pressed steel terminal boxes sunked for mounting switches/ socket, fan regulator, etc. size of box retangular 75 x 75 x 60 mm, complete all as specified and as directed.
Replacement of pressed steel terminal boxes sunked for mounting switches/ socket, fan regulator, etc. size of box retangular 175 x 100 x 60 mm, complete all as specified and as directed.
Replacement of pressed steel terminal boxes sunked for mounting switches/ socket, fan regulator, etc. size of box retangular 250 x 300 x 60 mm, complete all as specified and as directed.
Replacement of sheet metal enclosure cubical type made out of 1.6 mm thick mild steel sheet powder coated of size 750mmx450mmx300mm with four copper strip bus bar 200 Amps including one MCCB 200 Amps 25 KA and locking arrangement including cable connections and fixing to wall, complete all as specified and as directed.
Replacement of MCCB, TPN 125 Amp 415 Volts, 25 KA, complete all as specified and as directed.
Replacement of plug top 3 pin 20 amp earth metal clad suitable for industrial type DB, complete all as specified and as directed.
Replacement of socket 3 pin 20 amp earth metal clad suitable for industrial type DB, complete all as specified and as directed.
Replacement of MCCB, TPN 200 Amp 415 Volts, 36 KA, complete all as specified and as directed.
Replacement of AC Single Phase Two Wire, Static Meter, 240 V, 50 Hz, complete all as specified and as directed.
Replacement of AC Three Phase Four Wire, Static Meter 240 V, 50 Hz, complete all as specified and as directed.
Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 mtrs length, buried directly and preferably verthically in ground with top edge not less than 1.25 below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire al as shown in Plate No. 4 to the earthing test point all as specified and indicated including testing on completion. Note:- GI pipe eathing consider due to rocky area, complete all as specified and as directed.
Replacement of Ventilating fan 250 mm sweep plastic body type incuding self cosing louver and making all electric connections, complete all as specified and as directed.
Replacement of Ventilating fan 200 mm sweep plastic body type incuding self cosing louver and making all electric connections, complete all as specified and as directed.
Replacement of pressure pump of 0.5 HP incl connecting accessories of GI i.e bend, nipple, socket, tee of requisite size etc including cutting of existing pipe, complete all as specified and as directed.
Rewinding of relay of pressure pump upto 1 HP with copper winding wire of suitable copper wire, complete all as specified and as directed.
Replacement of heavy duty exhaust fan 300 mm sweep steel body type incuding self closing louver and making hole and all electric connections, complete all as specified and as directed.
Desmantling of old damaged solar water heating system spares including collector, checking of electric panel system, testing of all connections electric as well as water connections and removal of old U/S collector tubes and servicing of Solar water heating system with heat exchanger type -1 cold region , rated cap in ltrs per day 1000 LPD incuding all accessories required for & including spare parts like GI hot water pipe, complete all as specified and as directed.
Replacement of Heat exchanger tube type with titanium tubes to transfer Heat, equivalent of 1/5th of the daily load per hour with 10 degree contigrate temperature difference in primary and secondary system, complete all as specified and as directed.
Replacement of Interconnecting piping of size 15 mm dia existing for the solar collector all as specified and directed.The piping shall be of GI medium grade & fitting as per BIS specification. The minimum size of pipe shall be as per design but it should not be less than 50mm dia. The pipe shall be insulated with 50mm thick rock wool/mineral wool of 48 Kg/Cum density & have a Vapour barrier, chicken wire mesh and 24 gauge aluminium cladding. The cladding shall be suitable for out door applications, complete all as specified and as directed.
Replacement of Interconnecting piping of size 20 mm dia existing for the solar collector all as specified and directed.The piping shall be of GI medium grade & fitting as per BIS specification. The minimum size of pipe shall be as per design but it should not be less than 50mm dia. The pipe shall be insulated with 50mm thick rock wool/mineral wool of 48 Kg/Cum density & have a Vapour barrier, chicken wire mesh and 24 gauge aluminium cladding. The cladding shall be suitable for out door applications, complete all as specified and as directed.
Replacement of Interconnecting piping of size 25 mm dia existing for the solar collector all as specified and directed.The piping shall be of GI medium grade & fitting as per BIS specification. The minimum size of pipe shall be as per design but it should not be less than 50mm dia. The pipe shall be insulated with 50mm thick rock wool/mineral wool of 48 Kg/Cum density & have a Vapour barrier, chicken wire mesh and 24 gauge aluminium cladding. The cladding shall be suitable for out door applications, complete all as specified and as directed.
Replacement of Interconnecting piping of size 40 mm dia existing for the solar collector all as specified and directed.The piping shall be of GI medium grade & fitting as per BIS specification. The minimum size of pipe shall be as per design but it should not be less than 50mm dia. The pipe shall be insulated with 50mm thick rock wool/mineral wool of 48 Kg/Cum density & have a Vapour barrier, chicken wire mesh and 24 gauge aluminium cladding. The cladding shall be suitable for out door applications, complete all as specified and as directed.
Replacement of Differential temperature controller (DTC) with display the digital read out of temperature at the two sensor points, complete all as specified and as directed.
Replacement of Time totalizer as per existing, ccomplete all as specified and as directed.
Replacement of Auto/manual indicating lamps as per existing, complete all as specified and as directed.
Replacement of Start/stop switch for the pumps when it is running on manual mode as per existing, complete all as specified and as directed.
Replacement of Contactor 'NO" type as per existing, complete all as specified and as directed.
Replacement of Over load relay as per existing design condition at site, complete all as specified and as directed.
Replacement of Gun metal gate valves of upto 40mm size shall be provided for pump & other equipments, isolation for working maintenance & normal working as per existing, complete all as specified and as directed.
Replacement of Non return valves of size 20 mm dia, complete all as specified and as directed.
Replacement of flow meter sensor as per existing, complete all as specified and as directed.
Replacement of electrically operated control valve per existing, complete all as specified and as directed.
Replacement of stainer per existing, complete all as specified and as directed.
Replacement of insulation with minimum of 50 mm thick of rock wool/mineral wool of 48 Kg/Cum density and covered with vapour barrier chicken wire mesh and GI sheet of 24 Gauge thickness, complete all as specified and as directed.
Chicken wire mess of size 12.5mmx 0.51mm (24 SWG) hexagonal construction for cage covering of all solar water heater toughned glass plate including fixing, supporting mtrl and tightned with nut & bolts, complete all as specified and as directed.
Replacement of PC falanged suitable for solar water heater, complete all as specified and as directed.
Replacement of hose clamp suitable for solar water heater, complete all as specified and as directed.
Replacement of gaskets suitable for solar water heater, complete all as specified and as directed.
Nuts & bolts suitable for solar water heater, complete all as specified and as directed.
Replacement of safety valve of size 20 mm dia suitable for solar water heater tank, complete all as specified and as directed.
Replacement of elbow of size 20 mm diasuitable for solar water heater, complete all as specified and as directed.
Replacement of reducer suitable for solar water heater, complete all as specified and as directed.
Replacement ofnipple of size 20 mm dia 6" long suitable for solar water heater, complete all as specified and as directed.
Replacement of sockets of size 20 mm dia suitable for solar water heater, complete all as specified and as directed.
Replacement of tee of size 20 mm dia suitable for solar water heater, complete all as specified and as directed.
Replacement of glass of solar water heater as per existing size, all acomplete all as specified and as directed.
Replacement of solar water heater elements of 2 KW capacity as per existing size, complete all as specified and as directed.
Replacement of solar water heater elements of 3 KW capacity as per existing size, complete all as specified and as directed.
Replacement of solar water heater elements of 6 KW capacity as per existing size, complete all as specified and as directed.
Hire charges for providing, fixing in position of 1100 volt grade heavy duty cable PVC insulated aluminium conductor 4Sqmm stranded served with sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire two single core cables flat or circular complete laid on ground/fixed on steel pipes/wooden bullies/poles along with continuous copper conductor earth wire of suitable size PVC insulated/protection pipe where required, complete all as directed by Engr-in-charge. (300 RM x 90 days)
Hire charges for providing, fixing in position of 1100 volt grade heavy duty cable PVC insulated aluminium conductor 2.5Sqmm stranded served with sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire two single core cables flat or circular complete laid on ground/fixed on steel pipes/wooden bullies/poles along with continuous copper conductor earth wire of suitable size PVC insulated/protection pipe where required, complete all as directed by Engr-in-charge. (300 RM x 90 days)
Hire charges for providing and fixing in position light point, bell point/light socket point wiring with PVC insulated aluminum conductor cable 2.5 Sqmm including same size of copper conductor cable as earth wire partly in conduit laid in tents/shamianas wherever required including switches, sockets, lamps holders and bells complete fixed on proper boards, complete all as specified and as directed. (60 points x 90 days). (Note:- All cables and accessories shall be fire retardant low smoke).
Hire charges for providing and fixing in position power point, wiring with PVC insulated aluminum conductor cable 4 Sqmm including 2.5 sqmm size of copper conductor cable as earth wire partly in conduit laid in tents/shamianas etc wherever required including complete fixed on proper boards, complete all as specified and as directed. (30 points x 90 days) (Note:- All cables and accessories shall be fire retardant low smoke).
Hire charges for and including providing fixing and connecting properly the follwing safety devices complete all as specified and as directed. 30 NosX90 days. (a) MCB DBs 4 way SPN -1No. (b) MCB SPN 20 Amps-1 No. (c) MCB SP 6 to 32 Amps -2 Nos.
Hire charges for providing, fixing in position including testing Metal halide/flood light fitting including all accessories like lamp holder with lamp 500/1000 watt connected complete with suitable size of cable for exisiting poles/ballies including suitabe pipes brackets and clamps where required, complete all as specified and as directed. (45 Nos x 2 days)
Hire charges for providing, fixing in position of 1100 volt grade heavy duty cable PVC insulated aluminium conductor 6Sqmm stranded served with sheathing of PVC tape and overall PVC sheathed two single core cables flat or circular complete laid on ground/fixed on steel pipes/wooden ballies/poles along with continuous copper conductor earth wire of suitable size PVC insulated/protection pipe where required, complete all as specified and as directed. (1200 RM x 3 days)
Hire charges for providing, fixing in position of 1100 volt grade heavy duty cable PVC insulated aluminium conductor 4Sqmm stranded served with sheathing of PVC tape and overall PVC sheathed two single core cables flat or circular complete laid on ground/fixed on steel pipes/wooden ballies/poles along with continuous copper conductor earth wire of suitable size PVC insulated/protection pipe where required, complete all as specified and as directed. (1200 RM x 3 days)
Hire charges for providing, fixing in position extention board comprising of the following items complete including connected with suitable size of cable of approximate length 3 mtrs where required, complete all as specified and as directed. (45 Nos x 2 days) :- a) Socket outlet 5 amps with switches - 2 Nos b) Socket outlet 16 amps with switches - 1 Nos
Maintenance and safe custody of temporary electrification,detecting faults if any and making electric supply functional round the clock by providing the following for APG camp, complete all as specified and as directed. : a) Electrician - 05 Nos (Two electricians in two shifts during day and one electrician in one shift during night) b) Helper - 05 Nos (Two helpers in two shifts during day and one helper in one shift during night)
NOTE:- For minimum fair wages, EPF and payment to labour employed, refer Sch A Note No-16,17 and Special Condition No 5 & 21.2 of this tender. Contractor must produce all the relevent record such as payment made to labour, EPF etc at the time of payment of RARs/Final bill. No payment will be released to contrator without producing the proper record.
aggarwal engineers contractors
M/s Shubh Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .