| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹19.5 L+₹1.0 L (5.49%)Rejected-Finance 47 VED NAGAR COLONY DEORI ROAD AGRA 282 001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹19.9 L+₹1.4 L (7.46%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹20.4 L+₹1.9 L (10.3%)Rejected-Finance 34 1 12 2F SAINIK VIHAR DEORI ROAD AGRA UP 282007 | AGRA | UTTAR PRADESH | 282007 | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹20.5 L+₹2.0 L (11.0%)Rejected-Finance 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹20.3 L
EMD Value
₹40,500
Closing Date
13 Jul 2020, 6:00 pmClosed
GE EAST AGRA
62 TAJ ROAD GWALIOR HOUSE AGRA CANTT
REPAIR REWIRING TO INTERNAL ELECTRIFICATION INCLUDING REPLACEMENT OF DBS FITTIGNS IN AGRA FORT 411 PFC 7 PARA BDE MESS 801 TA 29 PARA 23 PARA GWALIOR ROAD UNDER GE EAST AGRA
2020_MES_336626_2
9247/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGRA
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE EAST AGRA
₹40,500
Yes
29 Jul 2020
6 Jul 2020
20 Jul 2020
6 Jul 2020
13 Jul 2020
8 Jul 2020
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including unserviceable fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. including making good disturbed surfaces of walls, floors, etc.complete all as specified and directed
M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts. grade FR PVC insulated unsheathed cable with proper colour coding drawn in including PVC concealed conduit not less than 20 mm dia with all accessories and FR PVC insulated 1.5 Sqmm multi standard sheathed copper wire for continues earth, sunk in cast iron/Pressed steel terminal boxes 60 mm deep & 1.6 mm thick duly painted with aluminum inside and anticorrosive paint out side/PVC polycarbonate PVC rectangular block 50 mm deep, including 3 mm thick plastic laminated sheet for mounting switches, sockets, fan regulators etc connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. Make Polycab/Finolex/RR Kablel/Grandlay. Note :Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible at no extra cost for the following :-
One light/fan point controlled by one switch 5 Amp SP one way
One 3 pin/5 pin socket outlet point 5 Amp on independent board
One 3 pin/5 pin socket outlet point 5 Amp on same board with other switches
Description all as per Item No 2 here-in-before but with 2.5 Sqmm (nominal area) multi stranded PVC insulated and unsheathed copper conductor FRLS cable for one 3 pin socket outlet 15 Amp on independent board including PVC insulated cable of 1.5 Sqmm size unsheathed copper conductor as earth wire
M&L for point wiring with and incl 1.5 sqmm (nominal area) PVC insulated multistranded copper conductor FRLS in and incl PVC casing and capping ISI marked 20/30 mm size or as required at site incl with its fittings and fixture such as ties, bends, elbows and juction boxes etc with 1.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing and common earth terminal ,One light point/fan point controlled by one way switch all as specified and directed. Make Polycab/Finolex/RR Kablel/Grandlay
One light/fan point controlled by one switch 5 Amp SP one way
One 3 pin/5 pin socket outlet point 5 Amp on independent board
One 3 pin/5 pin socket outlet point 5 Amp on same board with other switches
Description all as per Item No 4.00 here-in-before but with 2.5 Sqmm (nominal area) multi stranded PVC insulated and unsheathed copper conductor cable for one 3 pin socket outlet 15 Amp independent socket including PVC insulated cable of 1.5 Sqmm size unsheathed copper conductor as earth wire complete all as specified and directed
M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts. grade FR PVC insulated unsheathed cable with proper colour coding drawn in existing PVC concealed conduit with FR PVC insulated 1.5 Sqmm multi standard sheathed copper wire for continues earth, sunk in cast iron/Pressed steel terminal boxes 60 mm deep & 1.6 mm thick duly painted with aluminum inside and anticorrosive paint out side/PVC polycarbonate PVC rectangular block 50 mm deep, including 3 mm thick plastic laminated sheet for mounting switches, sockets, fan regulators etc connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. Make Polycab/Finolex/RR Kablel/Grandlay. Note :Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible at no extra cost for the following :-
One light/fan point controlled by one switch 5 Amp SP one way
One 3 pin/5 pin socket outlet point 5 Amp on independent board
One 3 pin/5 pin socket outlet point 5 Amp on same board with other switches
Description all as per Item No 6 here-in-before but with 2.5 Sqmm (nominal area) multi stranded PVC insulated and unsheathed copper conductor FRLS cable for one 3 pin socket outlet 15 Amp on independent board including PVC insulated cable of 1.5 Sqmm size unsheathed copper conductor as earth wire
S&F switch, piano flush type 5 Amp SP, one way complete all as specified and directed
S&F switch flush type, 15 Amp SP, one way complete all as specified and directed
S&F socket outlet, 5 pin, 5 Amp, flush type complete all as specified and directed
S&F socket outlet 2 in 1, 3 pin 5 and 15 Amp complete all as specified and directed
S&F ceiling rose , 3 phase/PVC/polycarbonate, isolated body surface Bakelite 65mm dia three terminals all as specified and directed.
S & F lamp holder insulated body with back plate for angle/batten fittings fixed on PVC top sheet cover complete all as specified and directed .
S&F ceiling fan regulator 240 Volt AC electronic type 5 step speed regulator suitable for ceiling fan 1200/1400 mm sweep and connecting & testing complete all as specified and directed
S&F energy saving 13.5 Watt LED IP 65 bulk head luminaries, complete with all accessories, internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size 230V,50 HZ all as specified and directed. Make : Cat Pt No LHEXCGP7IN5W013 of Havells or equivalent in Bajaj/Philips/CG
S & F in repair surface and wall mounted LED batten prewired suitable for use with LED 20 Watt including LED 20 watt tube rod complete including connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable 3 core of size 0.50Sqmm. all as specified and directed. Make : Cat Pt No LHFXCENNTN1W020 for box type fitting and Cat Pt No LHLDDCXCML8O020 LED Tube Rod of Havells or equivalent in Bajaj/Philips/CG
S&F in repair LED Post Top 25 Watt with low glare optical and high power including cable for connecting with connector all as specified and directed .Make : Cat Pt No RUBYPT25WLED757PSYMTOPC of Havells or equivalent in Bajaj/Philips/CG
S&F in replacement sub Main Wiring with two single core PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x6 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 4 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in existing conduit complete all as specified and directed by Engineer-in-charge including taking down of existing un serviceable sub main wiring complete.Make Polycab/Finolex/RR Kablel/Grandlay Note – 2 Nos of single core cable along with earth wire and PVC conduit shall be measured as one length.
Supply and fix in repair bell electric heavy duty Ding Dong type 230 volts single pole complete and all as specified. Make Cona cat part no 2856 or Anchor/SSK
S & F in repairs of sheet metal enclosure for DB’s IP 43 when MCBs to be used of 12 way single pole & neutral, 240 volt with 100 Amp rated bus bar double door type complete all as specified and directed Make- Legrand cat No 5076 12 or L& T cat No DBSPN008DD or equivalentin cat part of make ABB
S & F in repairs of sheet metal enclosure for DB’s IP 43 when MCBs to be used of 8 way single pole & neutral, 240 volt with 100 Amp rated bus bar double door type complete all as specified and directed Make- Legrand cat No 5076 11 or L& T cat No DBSPN008DD or equivalentin cat part of make ABB
S & F in repairs of sheet metal enclosure for DB’s IP 43 when MCBs to be used of 4 way single pole & neutral, 240 volt with 100 Amp rated bus bar double door type complete all as specified and directed Make- Legrand cat No 5076 10 or L& T cat No DBSPN004DD or equivalentin cat part of make ABB
S & F in repairs of sheet metal enclosure for DB’s IP 43 when MCBs to be used of 4 way TPN, 240 volt with 100 Amp rated bus bar double door type complete all as specified and directed Make- Legrand cat No 5078 85 or L& T cat No DBTPN004DD or equivalentin cat part of make ABB
S & F in repairs of MCB SP 240 volt 6 to 32 Amp complete all as specified and directed Make- L&T/Legrand/ABB
S & F in repairs of MCB SPN 240 volt 6 to 32 Amps complete all as specified and directed Make-L&T/Legrand/ABB
S & F in repairs MCB SPN 240 volt 40 Amp complete all as specified and directed Make- L&T/Legrand/ABB
S & F in repairs of MCB TPN 415 volts, 63 Amp complete all as specified and directed Make- L&T/Legrand/ABB
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to earthing lead GI steel wire 4.00 mm dia by means of nuts, bolts, check nuts and washers of galvanised iron or steel, earth lead protected by galvanised iron pipe 15 mm dia (medium grade) and connected to main switch board or main control panel as directed and as specified including concrete pit in PCC (1:3:6) type C1 pre-cast RCC cover slab 5 cm thick of size as shown reinforced with 8 mm dia TMT / deformed bars 100 mm c/c both ways including one handle made of 12 mm dia MS bars of length 500 mm, funnel, wiremesh 20 mm bore galvanised iron pipe medium grade for watering, charcoal and salt in alternate layers including necessary earth work complete all as shown in elect plate No. 3 of SSR Part - I and as directed Note:Cost of earthing lead and protection pipe up to 7.5 metre length shall be deemed to be included in quoted rate
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to earthing lead of GI strip 25x 4.00 mm by means of nuts, bolts, check nuts and washers of galvanised iron or steel, earth lead protected by galvanised iron pipe 32mm dia (medium grade) and connected to main switch board or main control panel as directed and as specified including concrete pit in PCC (1:3:6) type C1 pre-cast RCC cover slab 5 cm thick of size as shown reinforced with 8 mm dia TMT / deformed bars 100 mm c/c both ways including one handle made of 12 mm dia MS bars of length 500 mm, funnel, wiremesh 20 mm bore galvanised iron pipe medium grade for watering, charcoal and salt in alternate layers including necessary earth work complete all as shown in elect plate No. 3 of SSR Part - I and as directed Note:Cost of earthing lead and protection pipe up to 7.5 metre length shall be deemed to be included in quoted rate
S&F in repair of LED Bulb 10 W, warm white all as specified and directed. Make : Cat Pt No LHLDEUEEML8R010 of Havells or equivalent in Bajaj/Philips/CG
S&F in repair of LED Bulb 7 W, warm white all as specified and directed. Make : Cat Pt No LHLDEUHEML8R009 of Havells or equivalent in Bajaj/Philips/CG
S&F in repair of angular holder all as specified and directed.
S&F in repair of 5/15 Amp socket, 5 pin all as specified and directed.
S&F in repair of 5 Amp socket, 5 pin all as specified and directed.
S&F in repair of Plug top 15 Amp , 240 Volt all as specified and directed.
S&F in repair of Plug top 5 Amp , 240 Volt all as specified and directed.
S&F in repair of piano switch 5 Amp , 240 volt all as specifeid and directed.
S&F in repair of piano switch 15 Amp , 240 volt all as specifeid and directed.
S& F in repair surface and wall mounted LED batten box type prewired suitable for use LED 20 Watt tube light T8 all as specifeid and directed. Make : Cat Pt No LHFXCENNTN1W020 of Havells or equivalent Bajaj/Philips/CG
S&F repair Electronic fan regulator step type, AC, 230V all as specified and directed. Make : Havells/Bajaj/Philips/CG
S&F in repair piano type bell push 5 Amp 240 Vlot all as specified and as directed. Make : Havells/Bajaj/Philips/CG
neeraj electricals
M/S RAJENDRA KUMAR AGARWAL
M/S OM Enterprises
M/s SCHOLASTIC ENTERPRISES
3Krishna Enterprises
Unnati Engineers
virendera singh
M/S SHARADA ASOCIATE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .