Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹7.9 LAdmitted-Finance 103 S J HOUSE 1ST FLOOR SITARAM MILLS COMPOUND N M JOSHI MARG LOWER PAREL MUMBAI 400011 MAHARASHTRA | MUMBAI | MAHARASHTRA | 400011 | ₹7.9 L | Admitted-Finance |
| 2 | Rejected-Technical 1 G ROAD GOREGOAN W 1 T NAGAR ROAD NO 3 2 402 SURYA NIWAS L T NAGAR MUMBAI 400062 | MUMBAI | MUMBAI | MAHARASHTRA | 400062 | - | Rejected-Technical Find the chart |
| 3 | Rejected-Technical | - | Rejected-Technical Find the chart |
| Sl No | Description | Qty | Unit | Toshvin Analytical Pvt. Ltd. |
|---|---|---|---|---|
| 1.00UV VIS Double Beam Spectrophotometer | ||||
| 1.01 | UV VIS Double Beam Spectophotometer Make : Shimadzu, Model : UV-19001
Enables easy operation with an intuitive on-screen user interface -includes large, easy-to-see icons, and can be controlled with a finger or stylus pen Obtains high-accuracy spectra in just a few seconds Delivers excellent photometric repeatability accuracy of 0.0002 Abs max. (0.5 Abs and 1.0 Abs), enabling more accurate quantitation and the detection of low-concentration samples Includes multiple measurement modes, such as photometric, spectrum, quantitation, kinetics, time course and biomethod New to the UV-1900i are validation functions that are compliant with the United States Pharmacopeia (USP) and the European Pharmacopeia (EP). The instrument also can run checks for nine JIS items and the Japanese Pharmacopoeia (JP). Operators can save checked conditions and results and easily refer to them as needed. In combination with Lab Solutions TM DB/CS (not included),UV1900i will comply with FDA 21 CFR Part 11 and PIC/S GMP guidelines
. Wave number Range : 190 to 1,100 nm
Spectral bandwidth : 1 nm (190 to 1,100 nm)
Wavelength display :0.1 nm increments
Wavelength setting : 0.1 0.1 nm increments (1 nm increments when setting 0.2 0.2 scanning 0.3 range)
Wavelength Accuracy : ± 0.1 nm at D2 peak 656.1 nm, ± 0.3 nm for entire range
Wavelength Repeatability : ± 0.1 nm
Wavelength slew rate : About 14,500 nm/min
Wavelength Scanning Speed : 3000 to 2 nm/min, 29000 nm/min when survey scanning
Lamp interchangeable wavelength : Automatic interchange linked to wavelength. Interchange
can be set freely in the range of 295 to 364 nm (0.1
Stray Light : Less than 0.02% at 220 nm (Nal), Less than 0.02% at 340 nm (NaNO2), Less than 0.5% at 198 nm (KCL)
Photometric System : Double beam optics
Photometric range : Absorbance : -4 to 4 Abs
Transmittance : 0% to 400%
Photometric Accuracy : +/- 0.002 Abs at 0.5 Abs
+/-0.004 Abs at 1.0 Abs
+/-0.006 Abs at 2.0 Abs
Photometric repeatability : Less than +/- 0.0002 Abs at 0.5 Abs Less than +/- 0.0002 Abs at 1 Abs
Baseline stability : Less than 0.0003 Abs/hr (700 nm, one hour after light source turned ON)
Baseline Flatness : Less than +/- 0.0006 Abs (1100 to 190 nm one hr after light source turn ON.
Noise level : Less than 0.00005 Abs (700 nm)
Light source : 20-W halogen lamp and Deuterium lamp, Built in light source auto position adjustment
Monochromator : LO-RAY-LIGH grade blazed holographic grating in Czerny-Turner mounting
Detector : Silicon photodiode
Sample compartment : Internal dimension W110X D250X H115 mm, Distance between light beam : 100 mm
Power requirements : AC 100, 120, 220, 230, 240V, 50/60 Hz, 140 VA
Environmental requirements : Temperature: 15°C to 35°C Humidity: 30% to 80% (without condensation; 70% max, at 30°C or higher)
Dimension : W450xD501XH244 mm
Detector : silicon photodiode
Output device : USB memoryData file save in text format or UVPC format. UVPC-format file can be read directly by UV probe and Lab solution TM UV Vis
PC compatibility : External control possible via USB Also Compatible with Microsoft licensed windows 10 Professional
Display : 24 bit colour touch screen
Supported Languages : Japanese, English, Chinese, Spanish, Mexico, Portuguese
Supplied with below accessories
1.071-60845-01 Cord Set,3VTJ1 / 3VTJA H05VV-F
2. 10mm Rectangular Quartz Cell - 1 Pair
3. USB Cable for interfacing instrument with PC/Printer
Note: PC with win 10 professional licenses is requiring for above system is in your scope and responsibility | 1 | No | 6,70,000 ₹7.9 L |
Updated dates
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
18 Dec 2025, 1:00 pmClosed
Registrar
SGBAU, Amravati
Supply of Double Beam UV VIS Spectrophotometer
2025_SGBAU_1253479_1
SGBAU/2/Store/254/2025-26
Open Tender
Laboratory and scientific equipment
90 days
SGBAU
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,484
Yes
₹19,000
Yes
14 Jan 2026
28 Nov 2025
19 Dec 2025
28 Nov 2025
18 Dec 2025
28 Nov 2025
Select, Excess (+), Less (-)
Tender Inviting Authority: The Registrar ,Sant Gadge Baba Amravati University
Name of Work: Supply of UV VIS Double Beam Spectrophotometer
Contract No: . SGBAU/2/Store/254/2025-26 Date: 28-11-2025
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description [Details Product Specification Given in a Technical BID] Copy of Valid Authorization Certificate attached or not [Enter Y / N] Qty Units Estimated Rate in Rs. P Estimated QTY Required Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder in Rs. P Percentage (%) of GST (If applicable) GST Amount in Rs. P Copy of Valid Authorization Certificate attached or not [Enter Y / N] TOTAL AMOUNT excluding taxes in Rs. P TOTAL AMOUNT including taxes Rs. P TOTAL AMOUNT In Words
1 UV VIS Double Beam Spectrophotometer 1 Construction of chamber for 100mm sluices valve item1 10 1 Nos
1.01 UV VIS Double Beam Spectophotometer Make : Shimadzu, Model : UV-19001 Enables easy operation with an intuitive on-screen user interface -includes large, easy-to-see icons, and can be controlled with a finger or stylus pen Obtains high-accuracy spectra in just a few seconds Delivers excellent photometric repeatability accuracy of 0.0002 Abs max. (0.5 Abs and 1.0 Abs), enabling more accurate quantitation and the detection of low-concentration samples Includes multiple measurement modes, such as photometric, spectrum, quantitation, kinetics, time course and biomethod New to the UV-1900i are validation functions that are compliant with the United States Pharmacopeia (USP) and the European Pharmacopeia (EP). The instrument also can run checks for nine JIS items and the Japanese Pharmacopoeia (JP). Operators can save checked conditions and results and easily refer to them as needed. In combination with Lab Solutions TM DB/CS (not included),UV1900i will comply with FDA 21 CFR Part 11 and PIC/S GMP guidelines . Wave number Range : 190 to 1,100 nm Spectral bandwidth : 1 nm (190 to 1,100 nm) Wavelength display :0.1 nm increments Wavelength setting : 0.1 0.1 nm increments (1 nm increments when setting 0.2 0.2 scanning 0.3 range) Wavelength Accuracy : ± 0.1 nm at D2 peak 656.1 nm, ± 0.3 nm for entire range Wavelength Repeatability : ± 0.1 nm Wavelength slew rate : About 14,500 nm/min Wavelength Scanning Speed : 3000 to 2 nm/min, 29000 nm/min when survey scanning Lamp interchangeable wavelength : Automatic interchange linked to wavelength. Interchange can be set freely in the range of 295 to 364 nm (0.1 Stray Light : Less than 0.02% at 220 nm (Nal), Less than 0.02% at 340 nm (NaNO2), Less than 0.5% at 198 nm (KCL) Photometric System : Double beam optics Photometric range : Absorbance : -4 to 4 Abs Transmittance : 0% to 400% Photometric Accuracy : +/- 0.002 Abs at 0.5 Abs +/-0.004 Abs at 1.0 Abs +/-0.006 Abs at 2.0 Abs Photometric repeatability : Less than +/- 0.0002 Abs at 0.5 Abs Less than +/- 0.0002 Abs at 1 Abs Baseline stability : Less than 0.0003 Abs/hr (700 nm, one hour after light source turned ON) Baseline Flatness : Less than +/- 0.0006 Abs (1100 to 190 nm one hr after light source turn ON. Noise level : Less than 0.00005 Abs (700 nm) Light source : 20-W halogen lamp and Deuterium lamp, Built in light source auto position adjustment Monochromator : LO-RAY-LIGH grade blazed holographic grating in Czerny-Turner mounting Detector : Silicon photodiode Sample compartment : Internal dimension W110X D250X H115 mm, Distance between light beam : 100 mm Power requirements : AC 100, 120, 220, 230, 240V, 50/60 Hz, 140 VA Environmental requirements : Temperature: 15°C to 35°C Humidity: 30% to 80% (without condensation; 70% max, at 30°C or higher) Dimension : W450xD501XH244 mm Detector : silicon photodiode Output device : USB memoryData file save in text format or UVPC format. UVPC-format file can be read directly by UV probe and Lab solution TM UV Vis PC compatibility : External control possible via USB Also Compatible with Microsoft licensed windows 10 Professional Display : 24 bit colour touch screen Supported Languages : Japanese, English, Chinese, Spanish, Mexico, Portuguese Supplied with below accessories 1.071-60845-01 Cord Set,3VTJ1 / 3VTJA H05VV-F 2. 10mm Rectangular Quartz Cell - 1 Pair 3. USB Cable for interfacing instrument with PC/Printer Note: PC with win 10 professional licenses is requiring for above system is in your scope and responsibility A1 1 No 55 3 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
Total in Figures 4 Construction of chamber for 100mm sluice plates item5 10 Nos
Quoted Rate in Figures Select %
Quoted Rate in Words
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
Tech_BID.pdf
Tender Documents • 0.61 MB
BOQ_2160857.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid