Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹57.5 L+₹1.1 L (2.01%)Rejected-AOC 551 121 RAMPRASAD KHEDA TALKATORA ROAD ALAMBAGH LUCKNOW | LUCKNOW | UTTAR PRADESH | 226001 | L2 | Rejected-AOC L2 | |
| 3 | L3₹62.4 L+₹6.0 L (10.6%)Rejected-AOC MOHANLALGANJ LUCKNOW UTTAR PRADESH | LUCKNOW | UTTAR PRADESH | 226001 | L3 | Rejected-AOC L3 | |
| 4 | L4₹63.0 L+₹6.6 L (11.7%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
29 Nov 2022, 10:00 amClosed
Superintending Engineer
Superintending Engineer, VII Circle Irrigation Works, Sarojni Naidu Marg, Lucknow.
Remaining partial works of G.F. Dining and kitchen area, 2nd floor and 3rd floor New I.H. in Canal Colony Cantt. Road, Lucknow. LOT-03
2022_UPIDC_744983_4
03/SE-VII/2022-23
Open Tender
Civil Works - Buildings
Item Rate
120 days
Lucknow
Please refer Tender documents.
2 documents required · 2 mandatory
₹630
₹1.3 L
16 Dec 2022
24 Nov 2022
29 Nov 2022
24 Nov 2022
29 Nov 2022
24 Nov 2022
Amount
Brick work with common burnt clay non modular bricks of class 150 in superstructure above plinth level up to floor V level in all shapes and sizes Cement mortar 1:4 (1 cement : 4 coarse sand)
P / L 12mm thick cement plaster in single coat in interior plastering finished even & smooth 1 cement : 4 coarse sand including all L/M, T&P etc.
P / L 15 mm Thick cement plaster in single coat on rough side for exterior plastering finished even & smooth 1 cement : 4 coarse sand including all L/M, T&P etc.
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, up to 25 Meter above ground level including additional rows of scaffolding in stepped manner as per requirement of side made with 40 mm dia M.S. tube. placed 1.5 m center to center, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the execution of work of cleaning and/ pointing and/ applying chemical and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevation area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction of Engineer-in-charge (Butt hinges and necessary screws shall be paid separately) Second class teak wood 35 mm thick shutters.
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc as required. In gretings, frems, guard bars, ladders, railing, brackets, gate and similar works
Fly proof stainless steel Grade 304 wire gaue with 0.5 mm dia wire and 1.4 mm wide aperture with matching wood beading
Providing & Fixing float Glass panes 6.0 mm thick panes
Providing and fixing ISI marked M.S. Pressed butt hinges bright finished with necessary screws etc. complete 100x58X1.9 mm .
Providing and fixing ISI marked oxidized M.S. handles conforming to IS:4992 with necessary screws etc. complete 125 mm
Providing and fixing bright finished brass tower bolt (Barrel type) with necessary screws etc. complete 200x10 mm
Providing and fixing bright finished brass tower bolt (Barrel type) with necessary screws etc. complete 150x10 mm.
Painting or varnishing on iron work in small areas or new wood work with one coat of ready mixed paint & two coat of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials, labour and T&P etc required for proper completion of work
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and pre polished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, color and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of Slab over 0.50 sqm. Granite of any color and shade.
Providing and laying Vitrified floor tiles in in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved make, in all colors and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments, including the leveling with mortar required as site condition complete etc. Size of Tile 600x600 mm (In Flooring)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm (In Skirting)
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Providing and Laying of 40mm thick Cement concrete flooring 1:2:4 (1cement : 2 course sand :4 graded stone aggregate 20mm nominal size) finished with a floating coat of net cement including cement slurry, but excluding the cost of nosing of steps etc complete.
One priming coat & Three coat oil distemper on new work including supply of all materials, labour T & P etc. required for proper completion of work . (Three Coat)
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
S/o Hand rail and Balustrade modular system passive ss-304 grade decorative railing system comprising of hand rail 50 mm and 1.5 mm thick and 3 No. horizontal steel pipe of 19 mm dia and 1.5 mm thick of equal spacing with balustrade of SS Pipe of 38 mm and 1.5 mm thick @ 1200 , C/C of passivated SS 304 grade and fix duly on the floor with specially design rivet expansion bolt and finish the surface food and covering with steel shoe, with all visible stainless steel metal of 304 grade in satin finish height of railing is 900 mm as per detailed specification.
Providing and fixing of expansion joint system related with floor location aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and ecured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge. (Material shall confirm to ASTM 6063). as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical location in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge. (Material shall confirm to ASTM 6063). Floor Joint of 100 mm gap.
Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221-02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, bothnew and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). Wall Joint of 100 mm gap
P/F curtain rods of 1.25mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs etc. wherever necessary complete (a) 25 mm dia.
Supply and fixing of anodized aluminum door/partition having 2 mm thick aluminum Section excluding coating and an average coating of 20 micron fully glazed made of aluminum door tube size 83.5x44.65 m as vertical member and 1140 x 44.45 mm size tube in bottom and horizontal member door chaukhat should be of aluminum tublar vertical with two openable shutter, fixtures 5 mm glass handles locks screw necessary bending and excluding cost of floor spring if required for proper completion of the work. as per direction of Engineer in Charge.
Supply erection and testing with fixing of Ceiling Fans with fan motor of A.C. Permanet insulation, Capacitor rating conforming BEE 5 Star rating and IS: 374/79 and also comly with IS: 1709/1984 with latest amendment. The rate voltage 220/240 volts, 50Hz, 1-ph AC the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system.
MANOHAR LAL AND COMPANY
m/s mohd. zamil
M/S AAKASH TRADERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .