| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC DIWANBADA MANEGAON POST OFFICE KHAMARIA JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | ₹1.2 Cr Quoted ₹1.3 Cr | L1 | Accepted-AOC BEING LOWEST REASONABLE BIDDER |
| 2 | L2₹1.4 CrRejected-Finance | ₹1.4 Cr | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | C L BHATIA L1 | VEENUS ENGINEERS L2 |
|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed. | 233.39 | Per Cum | 165 ₹38,509.35 | 150 ₹35,008.5 |
| 2.00 | -ditto- as per item No. 01 above but exc 1.5m but not exc 3.00 in depth complete all as specified and directed. | 0.43 | Cum | 200 ₹86 | 190 ₹81.7 |
| 3.00 | Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. | 191.33 | Per Cum | 50 ₹9,566.5 | 45 ₹8,609.85 |
| 4.00 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point including spreading complete all as specified and directed. | 72.15 | Per Cum | 70 ₹5,050.5 | 50 ₹3,607.5 |
| 5.00 | Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. | 40.6 | Per Cum | 900 ₹36,540 | 899 ₹36,499.4 |
| 6.00 | Supply and laying un-reinforced precast concrete cable covers, Class HV type1 with peak, size 300 mm x 180 mm x 40 mm, complete all as specified and as directed. | 2,792 | Each | 24 ₹67,008 | 30 ₹83,760 |
| 7.00 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 11000 volts grade(Earthed) XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor of cross section area 95 sqmm, 3 core after taking out the old unserviceable XLPE/ PILCA cable and testing on completion complete all as directed. (Note : Excavation, earthwork, sand cushioning and cable protection will be measured and paid for separately) | 355 | Per Rm | 1,080 ₹3,83,400 | 1,050 ₹3,72,750 |
| 8.00 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 11000 volts grade(Earthed) XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor of cross section area 120 sqmm, 3 core after taking out the old unserviceable XLPE/ PILCA cable and testing on completion complete all as directed. (Note : Excavation, earthwork, sand cushioning and cable protection will be measured and paid for separately) | 263 | Per Rm | 1,170 ₹3,07,710 | 1,175 ₹3,09,025 |
| 9.00 | Taking down old u/s HT cable | 1,373 | RM | 10 ₹13,730 | 8 ₹10,984 |
| 10.00 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm and testing on completion complete all as directed. | 18 | Each | 5,200 ₹93,600 | 5,000 ₹90,000 |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
17 Dec 2025, 6:00 pmClosed
CWE JABALPUR
HQ COMMANDER WORKS ENGINEER, SUPPLY MARG, P B NO. 54, JABALPUR
REPAIR AND MAINTENANCE OF HT NETWORK SYSTEM AND OTHER CONNECTED WORKS AND REPAIR, MAINT AND REPLACEMENT EXTERNAL ELECTRIC SUPPLY HT OVERHEAD LINE, 2/4 POLES, ACSR CONDUCTORS UG CABLE, AB SWITCHES AND OTHER CONNECTED WORKS AND MAINT OF 33/11 KV
2025_MES_738601_1
81152/E8
Open Tender
Electrical and Maintenance Works
270 days
JABALPUR
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE (WEST) JABALPUR
₹2.2 L
Yes
26 Feb 2026
6 Nov 2025
24 Dec 2025
6 Nov 2025
17 Dec 2025
28 Nov 2025
6 Nov 2025 - 27 Nov 2025
Amount
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed.
-ditto- as per item No. 01 above but exc 1.5m but not exc 3.00 in depth complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point including spreading complete all as specified and directed.
Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed.
Supply and laying un-reinforced precast concrete cable covers, Class HV type1 with peak, size 300 mm x 180 mm x 40 mm, complete all as specified and as directed.
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 11000 volts grade(Earthed) XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor of cross section area 95 sqmm, 3 core after taking out the old unserviceable XLPE/ PILCA cable and testing on completion complete all as directed. (Note : Excavation, earthwork, sand cushioning and cable protection will be measured and paid for separately)
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 11000 volts grade(Earthed) XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor of cross section area 120 sqmm, 3 core after taking out the old unserviceable XLPE/ PILCA cable and testing on completion complete all as directed. (Note : Excavation, earthwork, sand cushioning and cable protection will be measured and paid for separately)
Taking down old u/s HT cable
M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm and testing on completion complete all as directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm and testing on completion complete all as directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm and testing on completion complete all as directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm and testing on completion complete all as directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50sqmm to 95sqmm and testing on completion complete all as directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185sqmm and testing on completion complete all as directed.
M&L for cable jointing kit for 33 KV (Earthed) grade cable for outdoor cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm and testing on completion complete all as directed.
Relaying or refixing or repassing in trenches/ on poles/ through pipes after taking out/ taking down the existing HT 11000 volts grade PILCA/ XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor of cross section area 95/120 sqmm, 3 core from trenches/ poles/ pipes and testing on completion complete all as directed. Notes:- (i) Excavation and earth work, sand cushioning and cable covers/ brick protection shall be measured and paid seprately under respective items. (ii) Joints shall be measured and paid seprately under respective items. (iii) Taking out/ taking down shall be done only after disconnecting all the connections of the cable from over head lines and panels.
Supplying and fixing/ laying of 80mm bore dia GI pipe light grade in trenches/ under roads/ along pole/ wall including all fittings, ISI marked as required for cable protection etc complete all as specified and directed.
Taking down old u/s GI Pipe any size
Drilling (Horizontally) to existing road (maximum 10M wide) suitable for passing GI tubing of dia upto 80mm/ 100mm as required at site complete all as specified and directed. Note:- All necessary T&P required at site for drilling shall be arranged by contractor at his own cost and quoted rate shall be deemed to be included for all these provisions and nothing extra shall be paid on this account.
Supply, fixing and stretching new ACSR conductors of any size and type for over head HT poles including binding at site to insulator with suitable size of binding wire etc after taking out the old unserviceable aluminium conductor of any size complete all as specified and directed by Engr in charge.
M&L for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint after taking out the old unserviceable cross arms, bracing, supports etc of any section complete all as specified and dircted.
Supply and fixing of new pin type porcelain, vitreous, white/ brown/ green insulator 150mm high and 150mm dia including one galvanised mils steel spindle, two galvanised iron washers and one galvanised iron nut, suitable for HT 11000 volts after taking out the old unserviceable insulator complete all as specified and directed.
Supply and fixing of new pin type polymer, vitreous, white/ brown/ green insulator 150mm high and 150mm dia including one galvanised mils steel spindle, two galvanised iron washers and one galvanised iron nut, suitable for HT 33000 volts after taking out the old unserviceable insulator complete all as specified and directed.
Supply and fixing of new disc type insulator, polymer, vitreous white/ brown/ green 145mm high and 225mm dia ball & socket type single disc assembly for tension with GI tension clamps for conductors for working pressure of 33000 volts after taking out the old unserviceable insulator complete all as specified and directed.
Supply & Fixing, in replacement, post type polymer insulator suitable for 33 KV complete all as specified and directed.
Supply and fixing of new disc type insulator, polymer, vitreous white/ brown/ green 145mm high and 225mm dia ball & socket type single disc assembly for tension with GI tension clamps for conductors for working pressure of 11000 volts after taking out the old unserviceable insulator complete all as specified and directed.
Taking down old u/s insulator any type any size
M&L for new lightning arrestor expulsion type complete with all fittings, transmision/ distribution class 65 KA, conforming to IS-3070 (Part-III) 1993 suitable for 11 KV system and mounting on poles including all necessary bolts, nuts and washers and making electric connection and testing on completion complete all as specified and directed.
Taking down old u/s LA any type any size
Routine and periodical cleaning of inside area of 11 KV Sub Stations including cutting and removal/ uprouting of unwanted grass/ bushes, small trees near all around sub station and pump houses complex complete including surface dressing and leveling by surface excavation and removal of debris to out side MD land wherever as required or as directed.
Supply and fixing, in replacement, Sealed maintenance free battery 12V, 150 AH complete all as specified and as directed
S&F,in replacement, PVC insulation tap 25 mm width, 5 mtr long complete all as specified and as directed.
S&F,in replacement, HT insulation tap 25 mm width, 5 mtr long complete all as specified and as directed ( Make : 3M Birla or Equivalent Make as approved by GE).
Supply and Fixing in replacement copper fuse wire 100 Amps complete all as specified and as directed .
Supply and Fixing in replacement copper fuse wire 200 Amps complete all as specified and as directed .
Readjustment, cleaning of contact, greasing and testing of out door type air break switch 11 KV current rating upto 400 Amps including all materials required for alignment for Air Break switch in position and replacement of unserviceable parts complete all as specified and as directed. (Note : Replacement of unserviceable parts shall be measured and paid for separately under relevant items )
Supply only brass terminal plate for mounting male contact of Air Break switch insulator including GI nuts and bolts, washers etc as required complete all as specified and as directed.
Supply only male contact for Air Break switch contact suitable for 11 KV complete all as specified and as directed.
Supply only female contact for Air Break switch contact suitable for 11 KV complete all as specified and as directed.
Supply only post insulator for Air Break switch with metal part suitable for HT 11KV conforming to IS 5572-1972 complete all as specified and as directed.
M&L for painting of alternate black & white strips to steel tubular poles/ rail poles of HT/ LT of over head lines with and including synthetic enamelled paint, total 05 Nos each strips on each pole, each strip having 0.15M height total up to 1.50M above from PCC coping and aluminium painting on all mild steel clamps, cross arm etc on poles with and including premium quality aluminium paint after necessary preparation of all surfaces of poles & fixures and fittings complete all as specified and as directed. Note:- All necessary T&P required at site for painting shall be arranged by contractor at his own cost and quoted rate shall be deemed to be included for all these provisions and nothing extra shall be paid on this account.
M&L for painting of alternate black & white strips to two pole structure consisting of two steel tubular poles/ rail poles of HT/ LT of over head lines with and including synthetic enamelled paint, total 05 Nos each strips on each pole, each strip having 0.15M height total up to 1.50M above from PCC coping and aluminium painting on all mild steel clamps, cross arm etc on poles with and including premium quality aluminium paint after necessary preparation of all surfaces of poles & fixures and fittings complete all as specified and as directed. Note:- All necessary T&P required at site for painting shall be arranged by contractor at his own cost and quoted rate shall be deemed to be included for all these provisions and nothing extra shall be paid on this account.
M&L for painting of alternate black & white strips to four pole structure consisting of four steel tubular poles/ rail poles of HT/ LT of over head lines with and including synthetic enamelled paint, total 05 Nos each strips on each pole, each strip having 0.15M height total up to 1.50M above from PCC coping and aluminium painting on all mild steel clamps, cross arm etc on poles with and including premium quality aluminium paint after necessary preparation of all surfaces of poles & fixures and fittings complete all as specified and as directed. Note:- All necessary T&P required at site for painting shall be arranged by contractor at his own cost and quoted rate shall be deemed to be included for all these provisions and nothing extra shall be paid on this account.
Providing the cable fault locating machine with all necessary tool and plants at work site for locating the exact pin point of fault along with the exact length of armourd 6.6/11 KV XLPE/ PILCA insulated HT cable complete all as specified and as directed. Note:- Cable fault locating machine along with all necessary T&P as required shall be arranged by contractor within very short notice as when asked by GE without fail and quoted rate shall be deemed to be included for all these provisions and nothing extra shall be paid on this account.
Supply, filling and topping up of indoor/ outdoor TRANSFORMERS of any capacity in various sub stations under GE (W) Jabalpur with new transformer oil, low viscosity type of dielectric strength 35 to 40 KV breaking voltage, conforming to relevant IS complete all as specified and directed. Make:- Savita or Power Oil or equivalent as approved by GE.
Supply and filling of silica gel as per existing make/ as per manufacturer's recommendations duly approved by GE suitable for indoor/ outdoor TRANSFORMERS up to 5000 KVA in various sub stations under GE (W) Jabalpur complete all as specified and directed.
Supply and fixing of silica gel breather (transparent type) with silica gel as per existing make/ as per manufacturer's recommendations duly approved by GE suitable for indoor/ outdoor TRANSFORMERS up to 5000 KVA in various sub stations under GE (W) Jabalpur complete all as specified and directed.
S&F in replacement DO fuse element of capacity 10 Amp to 100 Amp having 10 Nos of fuses in each pkt for 33 KV grade complete all as specified and directed.
S&F in replacement DO fuse element of capacity 10 Amp to 40 Amp having 10 Nos of fuses in each pkt for 11 KV grade complete all as specified and directed.
S&F in replacement DO fuse element of capacity above 50Amp upto 100 Amp having 10 Nos of fuses in each pkt for 11 KV grade complete all as specified and directed.
Supply and fixing of new Air break gang operated switch triple pole mechanically operated out door with all fitting/ accessories mounted on and including 11 KV polymer insulator and steel channel frame GI operating rod 25 mm dia of suitable length with operating mechanism worked from ground level vertically operated as per site requirement including DO set and locking arrangement for operating handle complete suitable for current rating upto 400 Amps, 11 KV working pressure including taking down existing old unserviceable Switch air break complete all as specified and directed by Engr in charge.
supply and fixing of new Air break gang operated switch triple pole mechanically operated out door with all fitting/ accessories mounted on and including 33 KV porcelain insulator and steel channel frame GI operating rod 25 mm dia of suitable length with operating mechanism worked from ground level horizontally operated as per site requirement including locking arrangement for operating handle complete suitable for current rating upto 400 Amps, 33 KV working pressure including taking down existing old unserviceable Switch air break complete all as specified and directed by Engr in charge.
Supply and fixing new stay assembly complete with accessories and GI stay rod 20 mm dia 1900 mm long, stay wire 7/4 mm stranded galvanised including mild steel stay plate 300 mm X 500 mm x 6 mm and galvanised thimble, galvanised steel 14 mm dia 400 mm long stay bow and GI nuts, washers including loop type insulator vitreous porcelain white, brown or green big size with overall dimensions 90 mm x140 mm clearance of hole 25.5 mm including taking out existing old/unserviceable stay assembly complete all as specified and shown in electrical plate No. 1 of SSR Part –I (2009).
M&L for cleaning/ prepration of complete external surfaces of POWER TRANSFORMER of capacity 1600-5000KVA, ratio 33/11 KV for painting with two coats of synthetic enamel paint of colour/ shed as approved by GE including writing letters or figures (Block, Roman, Italic or Indian) with and including thick enamel paint of approved colour/ shed not exc 5cm in height for SM/ MES No. etc of tranformer complete all as specified and directed.
M&L for cleaning/ prepration of complete external surfaces of DISTRIBUTION TRANSFORMER of capacity upto 750 KVA for painting with two coats of synthetic enamel paint of colour/ shed as approved by GE including writing letters or figures (Block, Roman, Italic or Indian) with and including thick enamel paint of approved colour/ shed not exc 5cm in height for SM/ MES No. etc of tranformer complete all as specified and directed.
M&L for cleaning/ prepration of complete external surfaces of VCBs/control panel of capacity upto 800 Amps for painting with two coats of synthetic enamel paint of colour/ shed as approved by GE including writing letters or figures (Block, Roman, Italic or Indian) with and including thick enamel paint of approved colour/ shed not exc 5cm in height for SM/ MES No. etc of tranformer complete all as specified and directed.
Repair and overhauling of gang operated drop out air break switch 33 KV double break rotating isolated fixed on 33 KV Gantry(33 KV Yard) with replacement of unserviceable parts complete all as directed by Engineer-in-Charge (Note : Labour for replacement of unserviceable parts is deemed to be included in the unit rate quoted against this item. However, unserviceable parts will be measured and paid for separately under relevent items as 'Supply only' )
Supply only tinned copper flexible jumper 400 Amps 33 KV to be fixed under item No. 86 here-in-before and testing on completion complete all as directed.
Supply only back connector plate to be fixed on completion complete all as directed.
Supply only Fixed contact 33 KV for rotary type double break isolator ( GOD Switch ) to be fixed under item No. 83 here-in-before and testing on completion complete all as directed.
Supply only Male contact 33 KV for rotary type double break isolator ( GOD Switch ) to be fixed under item No. 86 here-in-before and testing on completion complete all as directed.
Trimming of tree branches 4 metre all around, from the LT/HT pole, for clearing of LT/HT line, by cutting tree branches, any numbers and of any girth, on any number of conductors/earth wire complete all as specified and as directed by Engr- in- Charge. (Notes : (i) The above work includes cleaning/ pruning of tree branches falling around the conductors (ii) One length shall be measured for complete span of 4/5/6 conductors & GI wire.)
Re - stretching only of existing ACSR of any size, on HT/ LT pole including binding the ACSR with insulators, aluminium binding wire complete all as specified and as directed. (Note : One length shall be measured for complete span of 4/5/6 conductors & GI wire.)
Supply and fixing of new resin/ epoxy coated air cooled high tension current transformer of dual ratio of 100-50/5 Amps, 10 VA burden out put, accuracy class-0.5 conforming to IS 2705/IEC 60044-1 suitable for rated voltage system of 11KV for metering/ protection of breakers after taking out the old unserviceable CT and testing on completion complete all as directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised iron strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore GI pipe light grade including necessary fittings for protection of earthing strip, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge 8 mesh per linear including 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS TMT bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth strip alongwith protection pipe and testing on completion complete all as specified and directed. Note:- GI strip and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor.
M&L for centrifusing (Filteratin/dehydration of transformer oil including filter action using automatic centrifusing machine including arrnging elect supply for operation of machine to achieve min. 35 to 50 KV breaking capacity at 4 mm gap by absorbing and abolishing all sludge particles for use as per BS-B 66-1983 complete
Supply and Install auxilliary power supply system for protection of 33/11 KV panels complete with maintenance free lead acid batteries mounted on MS rack and connection complete in all aspects , with installled capacity 110V (2V volts x55) 100Ah, including 110V-25A booster and trickle charger, as per specifications and including DC DB for charger complete with DC ammeter , voltmeter, switches for 11/33 KV system complete with all controls incl taking out old u/s power supply system.
Supply, install, testing and commissioning 33 KV oil immeresed current transformer for deterring and protection single phase outdoor type mounted on fabricated steel structure and fixing bolts, nuts, check nuts, washers etc complete all as directed for system rated nominal voltage 33 KV and system rated highest voltage 36 KV, 50Hz, CT ratio 50-25-5 amps, rated burden 50 VA accuracy class 0.5, and aaccuracy class, 5P, first filling of transformer insulation oil conforming to IS-336 and of dielectric strength 60 KV as IS-1866 and complete with all accessories in and including taking down of existing unserviceable current transformer complete all as specified and directed.
M & L for painting of yard of 33 KV of33/11 KV power house including angle iron,Channel , post & flat iron strip with aluminium paint & steel gate with synthetic enamel grey paint including scrubbing of old paint and preparation for painting complete all as specified and directed by Engineer-in-charge.
M&L for heat shrinkable busbar insulation tubing 2.5 mm thick suitable for indoor and outdoor use made of flame retardant non-halogen based material of suitable size and for both circular or rectangular busbars , rated for 11 KV system voltage to be used for insulating busbar of 2 pole/4 pole structure, VCB etc.
Supply, laying, testing and commissioning of Cable jointing kit in replacement for 33 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 400 sqmm complete all as specified and directed by Engr in charge.
Supply, laying, testing and commissioning of cable end termination joint indoor type cold shrinkable type suitable for stranded aluminium conductor 3 core, 11 KV, earthed, XLPE 50 -95 Sq mm cross sectional area complete all as specified and directed by Engr in charge
Supply, laying, testing and commissioning of cable end termination joint indoor type cold shrinkable type suitable for stranded aluminium conductor 3 core, 11 KV, earthed, XLPE 120 -185 Sq mm cross sectional area complete all as specified and directed by Engr in charge
Supply, laying, testing and commissioning of cable end termination joint outdoor type cold shrinkable type suitable for stranded aluminium conductor 3 core, 11 KV, earthed, XLPE 50 -95 Sq mm cross sectional area complete all as specified and directed by Engr in charge
Supply, laying, testing and commissioning of cable end termination joint outdoor type cold shrinkable type suitable for stranded aluminium conductor 3 core, 11 KV, earthed, XLPE 120 -185 Sq mm cross sectional area complete all as specified and directed by Engr in charge
Earthing complete with copper earth plate electrode 60 cm x60 cm x 3.15 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including copper strip 20 X 3 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Supply & laying (in replacement) galvanized steel tubing "medium grade" with GI fittings in trenches/ under roads/ along pole/ wall for cable protection all as specified & directed by EIC for the following size:-
(a) 50mm bore
(b 80mm bore
Repairs/overhauling to 11KV/33 KV HT control Panels complete in and including the following repair works :- (a)Taking out 11KV High Tension VCB of 300Amps to 800 Amps rating trolley from High Tension control Panel after switching off electric supply.Checking of mechanical system for proper functioning of upward/downward movement of High Tension Vacume Circuit Breakers trolley including opening the VCB & checking the quality of vacume bottles/links , & servicing the fixed/ moving contact & blowing out dust and applying the proper lubrication/ greasing and reassembling the VCB including connection to HT panel complete. (b). Taking out Digital Micom 122 relay set from high tension, 11KV, VCB control panel and cleaning the contact (NO+NC) by CTC solution and adjust the contact and calibration the relay by giving the primary and secondry injection and checking the tripping system by relay testing kit for over current and earth fault & proper plug setting as per reqd load & time delay and fixing the relay set in High Tension control panels complete all as specified and directed by EIC .Note:- Testing of above job to be carried out by OEM only. (b) spare parts to be replaced shall be measured & paid separately under the relevent items as supply only.
Supply and fixing in replacement shunt trip coil assembly suitable for High Tension ,VCB control panels, operating on 30/110 volt system and testing complete all as specified and directed by EIC.(Make Crompton/GEC/Areva)
Supply and fixing in replacement closing coil operated on 110 / 30 volt AC/DCsystem
Supply and fixing in replacement under voltage coil assembly suitable for HT VCB operated on 110/30 volt system and testing complete all as specified and directed by EIC.
Supply and fixing in replacement charging motor for high tension, 11 KV, VCB panels, 400 Amps, operated on 230 volts AC or 30 Volts DC as per sample complete all as specified and directed by EIC.
Taking out the old U/S indoor type VCB/OCB incomming/outgoing/bus coupler 400/800 Amps capacity from main after dissconnecting the electric connection and making the arrrangements to feed the supply with to other available feeder taking out the VCB /OCB and Opening the Vaccum Circuit breaker 800 amps capacity and dismentaling ,repair, overhauling the VCB with making the required lathe works if required and reassembling its on original position with making alignment for smooth functioning the VCB complete with replacement of following items all as required and directed at site
(a) Trip shaft as per sample - 1 no
(b) Link shaft
( c) Closing spring lever
(d) Main shaft
(e) Roller
(f) Bearing
M&L for Vaccum interrupter 11 KV as per IS 13118-1991/IEC 56-1987 of 400 amps rating and fixing testing all as required and directed at site
Taking out the upper spout from existing panel and replacement of spout HT 11 KV VCB as per sample and fixing on panel all as required at site
Taking down and replacement of the Male contact made of tinned copper VCB panel 11 KV made of brass as per sample and fixing testing all as required and directed at site
Supply and spreading the stone aggregate og 40 mm size spreading in the substation/ as where directed at site
S&F Resin/Epoxy casted air cooled high tension current transformer of dual ratio of 100-50/5 Amps, 10 VA burden out put, accuracy class - 0.5, suitable for rated voltage system of 11 KV conforming to IS 2705/IEC 60044-1for metering/protection of breakers complete all as specified and directed. including taking down old Make-EEW/Alstom/Crompton Greaves/GEC/Areva or as approved by GE(I).
Resin/Epoxy casted circuit spout with metallic fittings of good conductivity as specified to connect/match with the existing 11KV bus bar complete in all respect as directed.including taking down old of make - Alstom/CG/Areva/GEC as approved by GE.
Supply and fixing in replacement charging gear of 11 KV, VCB, 400 Amps complete all as specified and directed by EIC.
Supply and fixing in replacement, Over current and earth fault relay having auxilary voltage 24-110 volts, + 15% AC/DCcomplete all as specified and directed, Make :- Model No MC 61 of L&T or equivalent make as approved by the GE including taking down old
Supply and fixing in replacement panel lighting lamp with holder with on/off toggle switch
Supply and fixing in replacement bakelite HRC fuses in control/VCB panels
Repair/maintenance of 33 KV remote control panel/ capacitor panel by providing of 2.5sqmm, twisted type copper wire, PVC insulated with bottle neck lugs and duly marking and bunching of wire to provide neat wiring of control panel, connector and bakelite fuses and making the tripping system and remote panel functional and testing after carrying out the repair work in and including disconnecting of existing unserviceable wire complete all as specified and directed by the Engr-in-charge at site.
Supply only breaker control switch suitable for 33 KV control panel and outdoor VCBs complete all as specified and directed including taking down old
Supply and fixing in replacement, power factor meter Model No ELF 3234 of emercon as per existing or as approved by the GE
Supply and fixing in replacement, Digital multifunctional meter Model No EM 6459, 0.5RS of Enercon as per existing or as approved by the GE
Supply and fixing in replacement, Push type on/off switch red or green for fixing in Remote control panel of 33/11 KV control panels complete as per existing or as approved by the GE
Supply and fixing indicator lamp with holder for various control panels/ VCB panels complete all as specified and directed
Supply & installation of 33 KV single phase outdoor oil cooled PT of ratio 11KV/rt3/110V/rt3, class 0.5-3 burden 50-50 VA including taking down of existing unserviceable current transformer complete all as specified and directed including taking down old
Supply, laying, fixing in cable duct, connecting and testing control cable, XLPE insulated, PVC inner sheath, galvanised wire/strip armoured, solid copper conductor, 1100 volts grade in and including taking down of old unserviceable control cables by opening of duct of any type and size and making good of follwing sizes including taking down old
(a) 2.5sqmm, 4 core
(b) 2.5sqmm, 8 core
M & L for duct cover Mild steel plates, chequered, of any thickness as required at site in Fe 410-W (Gde-E-250) quality-A with welding including lifting arrengment of duct cover complet in and incl taking out of existing rusted/unserviceable plates all as specified and directed by Engineer in cgharge.
Taking out existing PCC HT electric poles of any length including breaking of cement concrete, necessary excavation and earth work, dismantling cross arms, M.S. clamps, insulators etc and carefully taking down existing over head copper conductors or aluminium conductor.
M&L for dismantling of existing VCBs by disconnecting HT incoming and outgoing cables, disconnecting of earthings, and complete accories including providing transportation from one sub station to another substation and fixing, connecting, commissioning and testing the VCB at new location as directed by making all arrangements at new location and connecting the imcoming and outgoing cables as required and connecting the earthings etc and connecting the DC supply as well as AC supply for functioing of VCBs including overhauling of VCBs and making functional complete all as specified and directed by Engr-in-charge at site. Note : Spare parts required for making functional the VCBs if required shall be measured and paid seperately under relevant item of CA
Repairs/overhauling to 11KV RMU complete in and including the following repair works :- (a)Taking out top cover control Panel after switching off electric supply.Checking of mechanical system for proper functioning of upward/downward movement of moving contacts including opening the RMU & checking the quality of connections & servicing the fixed/ moving contact & blowing out dust and applying the proper lubrication/ greasing and reassembling the RMU including connection to HT panel complete. (b). Above repair shall include checking proper functioning of Load Break Switch (LBS), VCB inside RMU and DO fuse link and make them serviceable if found unserviceable. Note:- Testing of above job to be carried out by OEM only. (b) spare parts to be replaced shall be measured & paid separately under the relevent items as supply only.
Supply and fixing CEF HV Back-up fuse link, striker 80N (Medium) as per IEC 60282-1, indoor type suitable of ABB make RMU of capacity IN = 40 Amps, Un-12 KV, I3 -105 Amps, I1=63 kA, the fuse link shall be strictly as per sample available at 33 KV main power house or as directed by Engr-in-charge at site complete all as specified and directed.
Supply and fixing CEF HV Back-up fuse link, striker 80N (Medium) as per IEC 60282-1, indoor type suitable of ABB make RMU of capacity IN = 80 Amps, Un-12 KV, I3 -105 Amps, I1=63 kA, the fuse link shall be strictly as per sample available at 33 KV main power house or as directed by Engr-in-charge at site complete all as specified and directed.
Supply and erecting steel tubular poles 9 mtr long & 410SP31complete with cast iron base plate, final taper plug, bolt nuts & screws complete all as specified including painting of poles with one coat of red oxide primer and two coat of aluminium paint & embeded portion shall be painted with two coat of bituminous paint complete all as specifd and directed including taking down old.
Taking out existing steel HT electric poles of any length incl breaking of cement concrete, necessary excavation and earthwork, dismantling cross arms, MS clamps, insulators etc and carefully taking down existing over head copper conductor or aluminium conductor complete as required incl removing from site as directed.
M&L for providing cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling complete all as specified and dircted.
M&L for providing cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling complete all as specified and dircted.
M&L for providing cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) for coping of poles incl necessary formwork and finished the surface complete all as specified and dircted.
Supply and fixing in replacement shunt tripping coil of RMU as per existing one at site and testing on completion complete all as specified and as directed.
Supply and fixing , in replacement, load break switch mechanism assembly having two position spring assisted, Integrated line earthing switch making capacity and testing on completion complete all as specified and as directed.
Supply and fixing, in replacement, motor cut off for spring charging motor of VCB trolly of Make & specifications as per existing one at site and testing on completion complete all as specified and as directed.
Supply and fixing, in replacement, spring charging gear assembly for VCB trolly of Make & specifications as per existing one at site complete all as specified and as directed.
Supply and fixing of new LED indicator lamp with holder for various control panels/ VCB panels as per existing make/ as per manufacturer's instructions duly approved by Engr-in-Charge after taking out the old unserviceable switch and testing on completion complete all as directed.
Supply and fixing in replacement ZZ switch, trip circuit healthy of VCB and testing on completion complete all as specified and as directed.
Checking all the termination of control cable protection system of VCB (03 Nos), transformer upto 5 MVA ( 02 Nos), 33 KV CTs( 09 Nos), 33KV PTs (03 Nos), cutting the faulty end of protection cable and making new connection with proper size of thimble and replacement of sliding connection if required and testing on completion complete all as directed by Engineer-in-Charge.
Checking and testing of 33 KV CTs for VCBs by secondary injection current on primary side complete all as specified and directed.
Checking and testing 11 KV CT for HT VCB11 KV by secondary injection current complete all as specified and directed.
Calibration of voltmeter 33 KV ( 04 Nos), 11 KV ( 4 Nos) and Ammeter 33 KV(03 Nos), 11 KV( 12 Nos) with present system load complete all as specified and directed.
S&F,in replacement, PVC insulation tap 25 mm width, 10 mtr long complete all as specified and as directed.
Supply and Fixing in replacement copper fuse wire 50 Amps complete all as specified and as directed .
Supply and Fixing in replacement copper fuse wire 5 Amps complete all as specified and as directed .
M & L for painting of Gantry of 33 KV including angle iron,Chanle , post & flat iron strip with aluminium paint & steel gate with synthetic enamel gray paint incl dismantling all as specified and directed by Engineer-in-charge.
Supply and fixing of new Air break gang operated switch triple pole mechanically operated out door with all fitting/ accessories mounted on and including 11 KV polymer insulator and steel channel frame GI operating rod 25 mm dia of suitable length with operating mechanism worked from ground level horizontally operated as per site requirement including locking arrangement for operating handle complete suitable for current rating upto 400 Amps, 11 KV working pressure including taking down existing old unserviceable Switch air break complete all as specified and directed by Engr in charge.
M&L for cable route indicator for HT cable with 11000 Volts embossed in MS sheet 5mm mounted in 50mm angle iron duly painted in red , with one coat of red oxide over two coats of sunthetic emanel paint with height 300mm above GL with PCC foundation all as per required and directed by Engg in Charge.Note: Rate quoted by contractor shall deemed to be included of excavtion and earth work.
(A) Disconnecting and taking down of faulty/ defective copper wound POWER TRANSFORMER of capacity 1600-5000KVA, ratio 33/11 KV from HR sub station/ Ridge Road Sub Station in Jabalpur cantt and transporting the POWER TRANSFORMER to workshop for complete overhauling/ repairing & servicing as specified in sub Para (B) here- in- after and transporting back the POWER TRANSFORMER from workshop to its existing location after complete overhauling/ repairing & servicing including loading & unloading of POWER TRANSFORMER in to the truck with the help of skilled labours and re-installation of POWER TRANSFORMER at its existing position with the help of chain pullies & skilled labours and making all necessary incoming & outgoing connections and tightening of all connection nuts, bolts, screws etc including following testing at 33 KV before installation and commissioning at site complete all as specified & directed :- (a) Insulation Resistance Test (By 5000 V Megger) (b) Ratio Test (c) Double Voltage & Double Frequency Test (d) Transformer Oil Value BDV Test (e) Tap Changing Test of load for all tap position Notes:- (i) POWER TRANSFORMER shall only be got repaired from authorised Workshop of Manufacturers of transformer or any other Workshop which have been authorised by MPSEB for repairing of transformer of such type & capacities and GE will approve the workshop in writing before shifting the POWER TRANSFORMER for repairing. (ii) Contractor will submit the certificate of authorised workshop along with RARs and final bill dully verified and signed by Engr-in-Charge. (iii) Cost of cable jointing materials such as cable glands & lugs etc as required shall be deemed to be included in quoted rate and nothing extra shall be paid on this account. (iv) All necessary T&P required at site for shifting of POWER TRANSFORMER shall be arranged by contractor at his own cost and quoted rate shall be deemed to include for all these provisions and nothing extra shall be paid on this account.
M&L for opening the top cover of defective copper wound POWER TRANSFORMER of capacity upto 2500 KVA, ratio 33/11 KV for complete overhauling/ repairing & servicing in folllowing manner:- (a) Taking out the transformer oil from POWER TRANSFORMER and store the same into seperate barrel container . (b) Taking out the core/ coil assembly of POWER TRANSFORMER. (c ) Cleaning of POWER TRANSFORMER inside by using transformer oil. (d) Re-fixing the core/ coils after complete repair/ replacement of core/ coils in POWER TRANSFORMER including heating up of POWER TRANSFORMER core assembly to remove complete moisture. (e) Replacement of HV/ LV spindles and bushings etc. as per existing make/ as per manufacturer's recommendations duly approved by GE complete all as specified & directed. (f) Re-filling of the removed POWER TRANSFORMER oil after filtration/ centrifusing. (g) Re-fixing of the POWER TRANSFORMER top cover with and including new rubberized gasket set and nuts, bolts and washers for top cover as per existing make/ as per manufacturer's recommendations duly approved by GE and tightening of all nuts, bolts, screws & gasket etc (h) Checking of all electrical and mechanical components at workshop after making the POWER TRANSFORMER fully fuctional. (j) All other parts/ items/ components of POWER TRANSFORMER which are necessary to be replace in the opinion of Engr-in-Charge/ as per manuacturer's recommendations for smooth functioning of POWER TRANSFORMER, same shall also be replace for smooth functioning and cost of the same shall also be deemed to be included in the unit rate quoted by the contractor.
Supply only LV leg coils of copper conductor for POWER TRANSFORMER of capacity upto 2500 KVA, ratio 33/11 KV complete with insulation, varnishing by vaccum impregnation and baking of coil assembly in oven, complete all as specified & directed.
Supply only HV leg coils of copper conductor for POWER TRANSFORMER of capacity upto 2500 KVA, ratio 33/11 KV complete with insulation, varnishing by vaccum impregnation and baking of coil assembly in oven, etc complete all as specified & directed.
Supply only LV bushing 33/ 11 KV as per existing make/ as per manufacturer's recommendations duly approved by GE for transformers of capacity 1600 KVA to 5000 KVA, to be fixed, complete all as specified & directed.
Supply only HV bushing 33/ 11 KV as per existing make/ as per manufacturer's recommendations duly approved by GE for transformers of capacity 1600 KVA to 5000 KVA , to be fixed , complete all as specified & directed.
Supply only LV spindle (metal part) made out of brass with nuts and washers as per existing make/ as per manufacturer's recommendations duly approved by GE for transformers of capacity 1600 KVA to 5000 KVA, to be fixed, complete all as specified & directed.
Supply only HV spindle (metal part) made out of brass with nuts and washers as per existing make/ as per manufacturer's recommendations duly approved by GE for transformers of capacity 1600 KVA to 5000 KVA, to be fixed, complete all as specified & directed.
Disconnecting and taking down of faulty/ defective copper wound TRANSFORMERS of capacity upto 750KVA, ratio 11/0.433 or 0.415 KV from 2/4 pole structure or Sub Station in Jabalpur cantt and transporting the TRANSFORMERS to workshop for complete overhauling/ repairing & servicing as specified in sub Para (B) here- in - after and transporting back the TRANSFORMERS from workshop to its existing location after complete overhauling/ repairing & servicing including loading & unloading of TRANSFORMERS into the truck with the help of skilled labours and re-installation of TRANSFORMERS at its existing position with the help of chain pullies & skilled labours and making all necessary incoming & outgoing connections and tightening of all connection nuts, bolts, screws etc including following testing before installation and commissioning at site complete all as specified & directed:- (a) Insulation Resistance Test (b) Ratio Test (c) Double Voltage & Double Frequency Test (d) Transformer Oil Value BDV Test (e) Tap Changing Test of load for all tap position Notes:- (i) TRANSFORMERS shall only be got repaired from authorised workshop of Manufacturer of transformer or any other workshop which have been authorised by MPSEB for repairing of transformer of such type & capacities and GE will approve the workshop in writing before shifting the TRANSFORMERS for repairing. (ii) Contractor will submit the certificate of authorised workshop along with RARs and final bill dully verified and signed by Engr-in-Charge. (iii) Cost of cable jointing materials such as cable glands & lugs etc as required shall be deemed to include in quoted rate and nothing extra shall be paid on this account. (iv) All necessary T&P required at site for shifting of TRANSFORMERS shall be arranged by contractor at his own cost and quoted rate shall be deemed to be included for all these provisions and nothing extra shall be paid on this account.
M&L for opening the top cover of defective copper wound TRANSFORMERS of capacity upto 750KVA, ratio 11/0.433 or 0.415 KV for complete overhauling/ repairing & servicing in folllowing manner:- (a) Taking out the transformer oil from TRANSFORMERS and store the same into seperate barrel container. (b) Taking out the core/ coil assembly of TRANSFORMERS. (c ) Cleaning of TRANSFORMERS inside by using transformer oil. (d) Re-fixing the core/ coils after complete repair/ replacement of core/ coils or re-fixing of re-conditioned core/ coils in TRANSFORMERS including heating up of TRANSFORMERS core assembly to remove complete moisture. (e) Replacement the HV/ LV spindles and bushings etc. complete all as directed by Engineer-in-Charge. (f) Re-filling of the removed TRANSFORMERS oil after filtration/ centrifusing. (g) Re-fixing of the TRANSFORMERS top cover with and including new rubberized gasket set and nuts, bolts and washers for top cover as per existing make/ as per manufacturer's recommendations duly approved by GE and tightening of all nuts, bolts, screws & gasket etc (h) Checking of all electrical and mechanical components at workshop after making the TRANSFORMERS fully fuctional. (j) All other parts/ items/ components of TRANSFORMERS which are necessary to be replace in the opinion of Engr-in-Charge/ as per manuacturer's recommendations for smooth functioning of TRANSFORMERS, same shall also be replace for smooth functioning and cost of the same shall also be deemed to be included in the unit rate quoted by the contractor.
Re-conditioning of LV leg coils of copper conductor for TRANSFORMERS of capacity upto 750KVA complete with insulation, varnishing by vaccum impregnation and baking of coil assembly in oven, complete all as specified & directed. (Note:- Reconditioning of LV leg coils shall be done if only insulation found damaged and conductor strip is intact i.e. not deformed/ damageed. This item involves all turns of leg coil to be reconditioned, removing complete insulation from conductor strip, cleaning of conductor, wrapping of conductor with fresh DPC insulation and remaking of LV leg coils with reconditioned strip complete all as directed by Engineer-in- Charge.
Re-conditioning of HV leg coils of copper conductor for TRANSFORMERS of capacity upto 750KVA complete with insulation, varnishing by vaccum impregnation and baking of coil assembly in oven, etc complete all as specified & directed. (Note:- Reconditioning of HV leg coils shall be done if only insulation found damaged and conductor strip is intact i.e. not deformed/ damageed. This item involves all turns of leg coil to be reconditioned, removing complete insulation from conductor strip, cleaning of conductor, wrapping of conductor with fresh DPC insulation and remaking of HV leg coils with reconditioned strip complete all as directed by Engineer-in- Charge.
Supply and fixing of new rubberized gasket set and nuts, bolts and washers for top cover, LT terminal box and replacement of LV/ HV spindles & bushings if found unserviceable etc as per existing make/ as per manufacturer's recommendations duly approved by GE suitable for indoor/ outdoor TRANSFORMERS of capacity up to 750 KVA to stop the leakage after opening the top cover and taking out and re-filling the transformer oil after filtration/ centrifusing of oil as required in various sub stations under GE (W) Jabalpur complete all as specified and directed. Notes:- (i) HV/ LV spindles and bushings shall be measured and paid separately under respective items of BOQ as supply only. (ii) Filtration/ centrifusing of usable transformer oil including filter action by using automatic centrifusing machine shall be measured and paid separately under respective item of BOQ. (iii) Topping of TRANSFORMERS with new transformer oil if required and same shall be measured and paid seprately under respective item
Supply only LV leg coils of copper conductor for TRANSFORMERS of capacity upto 750KVA complete with insulation, varnishing by vaccum impregnation and baking of coil assembly in oven etc, to be fixed, complete all as specified & directed.
Supply only HV leg coils of copper conductor for TRANSFORMERS of capacity upto 750KVA complete with insulation, varnishing by vaccum impregnation and baking of coil assembly in oven etc, to be fixed, complete all as specified & directed.
Supply only HV bushing 11 KV as per existing make/ as per manufacturer's recommendations duly approved by GE for transformers of capacity upto 750KVA, to be fixed, complete all as specified & directed.
Supply only LV bushing 0.433/ 0.415 KV as per existing make/ as per manufacturer's recommendations duly approved by GE for transformers of capacity upto 750KVA, to be fixed, complete all as specified & directed.
Supply only HV spindle (metal part) made out of brass with nuts and washers as per existing make/ as per manufacturer's recommendations duly approved by GE for transformers of capacity upto 750KVA, to be fixed, complete all as specified & directed.
Supply only LV spindle (metal part) made out of brass with nuts and washers as per existing make/ as per manufacturer's recommendations duly approved by GE for transformers of capacity upto 750KVA, to be fixed, complete all as specified & directed.
Schedule of credit amount of Rs 907788.00 to be deducted during AOC
VEENUS ENGINEERS (BID ID -3500982)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.