Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹9.0 L+₹76,042 (9.19%)Rejected-Finance 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L2 | Rejected-Finance Being Not Lowest | |
| 3 | L3₹9.5 L+₹1.2 L (14.9%)Rejected-Finance 0 MADHUPUR SAKARDAHA MADHUPUR SAKARDAHA SARAON MADHUPUR SAKARDAHA ALLAHABAD UTTAR PRADESH 212502 | PRAYAGRAJ | UTTAR PRADESH | 212502 | L3 | Rejected-Finance Being Not Lowest |
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
20 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Prabhat Kumar Singh, AGE (I)
AGE (I) Manauri Allahabad-212212
REPAIR / MAINT OF LT DISTRIBUTION NETWORK/ PANELS/ CABLES WITH OTHER CONNECTING WORK IN NEW PROJECT AND OFFICERS ENCLAVE AT 24 ED UNDER AGE(I) AF MANAURI
2020_MES_355833_1
8818/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Manauri, Allahabad
Class E cat b (i)
7 documents required · 7 mandatory
₹500
AGE (I) Manauri
₹19,800
Yes
13 Oct 2020
20 Jul 2020
24 Aug 2020
20 Jul 2020
20 Aug 2020
6 Aug 2020
60 days
Amount
Excavating in trenches not exc. 1.5m wide and not exc. 1.5 metre deep and getting out in soft/loose soil complete.
Returning filling in foundation/trenches including spreading leveling, watering and well ramming in layers not exceeding 25cm thick in soil complete.
Removal of surplus excavated material to a distance n.exc. 50 metre and depositing where directed at a level n.exc. 1.5 metre above starting point complete.
M & L for sand cushioning for under ground cable with locally available sand for protection of cable 8cm before laying cable and 15cm deep over the cable including spreading and consolidations, complete. (Note-Punned thickness ie 180mm will be measured and paid)
M&L for brick protection cover over cable of sub class 'B' bricks (old size Bricks) laid dry over LT cable width of brick shall be laid across the length of cable) complete all as specified and as directed.
Cutting/boring to plinth protection/hard standing/road etc in suitable depth and crossing of GI pipe of size 80 mm bore so that XLPE underground cable can be passed and giving mechanical protection to cable complete all as specified and directed. Note:- Quoted rate shall be included the cost of required material for repairing to disturbed surface all as per existing specification and GI pipe shall be measured and paid separately under respective items.
Disconnecting and taking upto and relaying the same at old/new position XLPE cable in all specification from trenches /duct /pipe including bricks setting aside for reuse or made to schedule of credit as per site required complete all as specified and directed. Note:- (i) Excavation & Earth work shall be measured and paid separately under respective item of this schedule. (ii) New Bricks & sand for cable protection shall be used and shall be measured and paid separately under respective item of this schedule. (iii) Old material i.e. bricks etc shall be contractors property & amount shall be deducted as per schedule of credit.
BLANK
Supply, laid in trench /fixed in replacement by re-routing with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with aluminium conductor 1100 volts, grade cross section area 4 core x 25 Sqmm (earthed) complete all as specified and directed.
All as per item No 9 above but size of cable 3.5 core x 50 Sqmm (earthed)
All as per item No 9 above but size of cable 3.5 core x 70 Sqmm (earthed)
All as per item No 9 above but size of cable 3.5 core x 95 Sqmm (earthed)
All as per item No 9 above but size of cable 3.5 core x 120 Sqmm (earthed)
Supply & fixed in replacement 40 MM dia bore GI tubing 'light grade' with fixing accessories laid in trenches or on wall or pole with clamp complete all as specified & directed.
All as per item No 14 above but of 50 mm dia bore
All as per item No 14 above but of 80 mm dia bore
M&L painting to steel prepared surfaces of any width or girth not otherwise described by using synthetic enamel paint in two coats (one as finishing coat) over one coat of red oxide zinc chrome primer on surface of steel structure /girder/ angle frame / wire mesh fencing (both side) / installation board / gate etc in any description at E/M installation using paint spray gun on specified working pressure including sign making /marking with using different colour in given size of letter etc complete all as specified and directed. Note- Paint colour & shade including writing marking of letters etc shall be deemed included in quoted unit rate and the same shall be approved by Deptt.
M & L Painting to existing two/three steel pole structure of 11 mtr height including mild steel work like cross arms, clamps, pipe channel, bracing etc after cleaning and prepration of surfaces painting externally above planting depth with one coat of aluminum paint over a coat of aluminum primer including preparation of existing surfaces and marking pole numbers in 15 cm dia with approved colour in circular and making 03 Numbers & 02 Numbers of bands & strips with 30 cm wide fluorescent paint from bottom of pole to 1.5 mtr height of pole complete all as specified and as directed. Note : Cutting of bushes & tree branches upto 3 Mtrs height of pole shall be deemed included in quoted unit rate.
All as above item No 18 here in before but single steel tubular pole in 9 /11 Mtrs long.
Supply , straining and straightening of aluminium conductor steel reinforced (ASCR) in any specification making interconnection of network fixing on existing structure/pole including taking down existing ACSR conductor any type complete all as specified and directed. Note: Sagging length of ACSR conductor shall be deemed included in the quoted unit rates & in this regard no extra length shall be measured & recorded.
M & L for earthing complete with galvanized steel earth plate electrode of size 60 CM x 60 CM x 6 MM thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below the ground level) with top edge of earth plate not less than 1.50 Mtrs below normal ground level connected to galvanized earth lead strip 32 x 6 MM size by means of nut, bolts & check nuts and washers of galvanized iron or steel connected to earthing test point complete all as specified or indicated, including earthing pit with PCC 1:3:6 type C 1 using 20 mm graded stone aggregate & RCC cover slab 40 MM thick as in RCC 1:2:4 type B-1 using 20 MM graded stone aggregate, reinforced with 8 MM dia TMT bars @ 150 MM centre to centre both way with two Nos lifting handle, GI pipe 20 MM dia 'light grade' with funnel and wire mesh for watering and 40 MM dia 'light grade' GI pipe for GI earth strip 32 x 6 MM protection etc complete all as shown in electrical plate No. 3 of SSR Part - I (2009) including testing on completion including dismantling of old existing earthing complete all as specified and directed. Note:- Items includes cost of 7.5 metre galvanized earth lead strip 32 x 6 MM.
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chasses or buried in ground or drawn in conduit / pipes or fixed to pole or any other indicated situation for loop earthing etc for galvanised earth strip 32x6mm including taking down existing strip complete all as specified and directed.
M&L for erection in position of true vertical swaged tubular pole type 410 SP-31 [9.0 m long] complete with cast iron base plate, finial taper plug, bolts, nuts and screws and top cover complete including taking out old pole any type from ground and making good disturbed surface complete all as specified & directed including following:-
[a] Excavation in trenches not exceeding 1.5 m wide & 2 m deep for pole foundation & getting out soft loose soil, returning filling soil in the trenches after fixing of pole in foundation ramming earth around the layers not exceeding 25 cm thick and disposal of surplus soil to a distance not exceeding 50 m. [b] M&L providing PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation 600 mm x 600 mm cross section planting depth 1.8 m for concrete casing the pole up to ground level. [c] M&L providing PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth band/ collar 300 mm high from ground level & 450 mm dia. [d] M&L painting of pole on external surface with one coat of black bituminous paint [up to planting depth] and above plinth band/ concrete collar with two coats of aluminium paint over a coat of red oxide primer including preparation of steel surface and painting with synthetic enamel paint blue colour, circular band three number of 30 cm wide in alternate layer up to height of 1.5 m above plinth band of pole. [e] Material & labour writing letter or figures/ pole number [Block, Roman, Italic as Indian] with thick synthetic enamel paint of approved shade not exceeding 30 cm. Note: (i) Old dismantled portion of LT poles in grounds shall be filled with PCC (1:5:10) type E-2 using 40 mm graded stone aggregate. Cost of PCC filling shall be deemed included in quoted unit rate (ii) Rate shall be deemed to include cost of Eearth work, PCC & other work as mentioned here-in before (a) to (e) under this item.
BLANK
S&F in replacement of cross arms bracing, supports, clamps and back plate fabricated from structural steel section including nut & bolts, washers, welding, bending, cold or hot, drilling hole for bolts in any shape or size as indicated complete all as specified and as directed. Note:- Painting shall be measured & paid separetaly under respective item of this schedule.
S&F in replacement MCCB, 3 pole, 63 Amp rating having breaking capacity of 16 KA, 415V adjustable thermal process based magnetic setting type Ics=75% Icu complete all as specified aid directed. Make: Legrand Cat part No 420003 or equivalent in makes as specified in list of make Appendix 'B' to particular specifications.
All as per item No 26 above but 4 pole 415 Amps 125 Amps rating having breaking capacity of 16 KA, 415V. Make: Legrand Cat part No 420016 or equivalent in makes as specified in list of make Appendix 'B' to particular specifications.
S&F in replacement MCCB, 4 pole, 250 Amp rating having breaking capacity of 36 KA, 415V adjustable thermal process based magnetic setting type Ics=75% Icu complete all as specified and directed. Make: Legrand Cat part No 420249 or equivalent in makes as specified in list of make Appendix 'B' to particular specifications.
Supply. Installation, testing and commissioning of LT Panel in cubical housing cabinet, outdoor type, double door platform mounted (minimum height 45 cm above normal GL and 30 cm below normal GL) , CPRI approved factory made, totally enclosed, dust and vermin proof made out by 3.15 MM thick CRCA MS sheet and full built upon angle iron frame in size 40 x 40 x 6 MM, having front and rear hinged both side openable doors and lifting lugs (02 Nos) , locking arrangement to be connect to earthing strip at rear side, bottom detachable both side openable ,gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers sheet steel bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment. The panel shall be epoxy powder coated and the control circuit shall be connected by suitable size of copper strip in proper colour coding and drawn through in flexible conduit. The panel should be suitable for 415 volts ,50 Hzs, 3 phase,4 wire system ,suitable rating CTs and PTs, internal connection should be made by copper strip in suitable rating, making incoming and outgoing connection using gland in suitable size including grouting KIOSK on floor (60 CM above the ground surface) in floor angel iron 40 x 6 MM imbedded to fixed the KIOSK with nut bolt, floor PCC (1:2:4) type B1 using 20 MM grade stone aggregate ( minimum 50 CM above GL and 30CM below GL) complete comprising the following items:-
Supply, jointing, commissioning and testing heat shrinkable end termination /straight through jointing kit suitable for 1100 volt grade (Earthed) cable for outdoor/indoor type complete with jointing material and required accessories suitable for underground XLPE cable of size 4 Core x 16 Sqmm (earthed) complete all as specified and directed. Make: Dension/3M/Rahycam or make as mentioned in Appx 'B' of PS.
All as per item No 30 above but for 4 core x 25 Sqmm (earthed)
All as per item No 30 above but for 3.5/4 core x 50 Sqmm (earthed)
All as per item No 30 above but for 3.5/4 core x 70 Sqmm (earthed)
All as per item No 30 above but for 3.5/4 core x 95 Sqmm (earthed)
All as per item No 30 above but for 3.5/4 core x 120 Sqmm (earthed)
All as per item No 30 above but for 3.5/4 core x 150 Sqmm (earthed)
All as per item No 30 above but for 3.5/4 core x 240 Sqmm (earthed)
Supply and fixed in replacement of flood light fitting LED 200/215 W equipped with IP66 protection to be fix on pole/ wall etc all as site making all connection using suitable three core flexible copper cable drawn through in flexible conduit pipe from control box to light fittings complete all as directed. Note :- (i) Fitting shall be of Make : Bajaj (TURBO LED) cat No BARFEG 200 W LED or Crompton cat Part No LSFO-200-CDL/60 or philips cat part No BVP410LED215 CW HE NB FG S4 XTFCL or equivalent model of make Wipro. Light fitting of other make of higher capacity may be used without any price adjustment. (ii) Cable from MCB to fitting shall be included in unit rate quoted by contractor.
Supply and fixing in replacement to pin type porcelain vitreous white brown or green insulator including one galvanised mild steel spindle two galvanised iron washer and one galvanised iron nut 65 MM dia with bolt washer suitable for 1100 volt grade complete.
All as per item No 39 above here in before but shackle type in size 100 MM height, max dia 115 MM suitable for 1100 volt grade with GI strip 31 X 5 , 14 MM dia of bolt complete all as specified and directed.
S&F in replacement stay assembly comprising of 7/8 SWG galvanised stay stranded wire in required length fixed between pole and hook with flat iron clamp bolts nut and washer, galvanised 14 MM dia, 400 MM long, stay bow with 19/20 MM dia 215 CM long stay rod with threaded ends, GI nut and washer, GI stay plate 230x 230 x 6 mm thick plate, two nos thimble, MS clamp made out of 50x 6 MM flat iron loop insulator made of 90 MM x 140 MM dia, 25 MM porcelain all as shown in electrical plate No 1 including required excavation/ earthwork and PCC for foundation and coping in size 30 x 30 x 30 CM complete all as specified and as directed. Note: Quoted rate shall deem to be included cost of earth work and cement work.
M&L cement concrete 1:2:4 type C-1 using 40 mm graded stone aggregate as in foundation, filling & mass concrete complete as specified & directed.
Supply and fixing of MS galvanised chain link fencing laid with steel structure frame in given size , bending clamping etc including two run of MS bar in 10 MM dia as line bar for holding fixed as parallel continue for bracing and two No stand post struts bracing (both side of stand post ) made out by GI strip in size 32 x6 MM for holding fixed with using 02 Nos nut bolt and washer in suitable size including dismantling of old chain link fencing alongwith fixing articles. Note:- Painting shall be measured & paid separetaly under respective item of this schedule.
Supply and fixed in replacement to Driver control plate in existed security light fittings for 45 watts LED light in original manufacture suitable for any model/ make etc all as per site requirement complete.
Supply and fixed in replacement to Driver control plate in existed security light fittings for 60 watts LED light in original manufacture suitable for any model/ make etc all as per site requirement complete.
Supply and fixed in replacement to Driver control plate in existed security light fittings for 100 to 150 Watts LED light in original manufacture suitable for any model/ make etc all as per site requirement complete.
Supply and fixed in replacement to Driver control plate in existed security light fittings for 200 Watts LED light in original manufacture suitable for any model/ make etc all as per site requirement complete.
Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri if not mentioned in BOQ.
M/S VIJAY SINGH
Avion Industries
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .