Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
27 Oct 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Deposit Work
Above/Below/Par
TECHNICAL
16 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Note: In case, date of tender inviting is on or after date of statutory deadline for audit of balance sheet of previous FY (i.e. 30th Sept or as further extended for this FY), audited balance sheet of 4th previous year shall not be considered unless concerned CA certifies that balance sheet is not audited yet as on date of invitation of this tender.
The contractor should have valid Electrical Contractor License issued by Govt. and submit along with tender document. If valid Electrical Contractor License is not submitted along with tender document, then offer will be summarily rejected.
16 conditions · 3 needing a document upload
The tenderer shall submit all relevant documents as detailed in para 14 & 18.10 of Tender Form (Second Sheet) of Part I of GCC work-2022.
The tenderer shall submit copy regarding status of firm i.e. sole proprietorship, partnership, Company, Society/Trust etc. and also submit a power of attorney and other relevant documents as detailed in Para no. 15 of Tender Form (Second Sheet) of PartI of attached GCC-2022.
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be. Following documents shall be submitted by the tenderer:
a) Sole Proprietorship Firm: (i) All documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(b) HUF: (i) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC2022.
(c) Partnership Firm: (i) A notarized copy of the Partnership Deed or a copy of the Partnership deed registered with the Registrar. (ii) A notarized or registered copy of Power of Attorney in favour of the individual to tender for the work, sign the agreement etc. and create liability against the firm. (iii) An undertaking by all partners of the partnership firm that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP in which they were / are partners/members. Any Concealment / wrong information in regard to above shall make the bid ineligible or the contract shall be determined under Clause 62 of the Standard General Conditions of Contract. (iv) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(e) Company registered under Companies Act 2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(f) LLP (Limited Liability Partnership): (i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation (iii) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv) An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm / LLP or JV in which they were / are partners / members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(g) Registered Society & Registered Trust: (i) A copy of Certificate of Registration (ii) A copy of Memorandum of Association of Society/Trust Deed (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust. (iv) A copy of Rules & Regulations of the Society (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he / they be partner(s) of the firm or any other person, specifically authorizing him / them to sign the tender, submit the tender and further to deal with the Tender / Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association / Board resolution, failing which tender shall be summarily rejected. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he / they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Apostille certificate.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should quote only the above/below percentage on estimated value, in the space provided at web portal for the purpose & nowhere else. Financial & Technical conditions quoted at any place other than prescribed space shall not be entertained while evaluating the offer.
Tenderer are required to go through the documents attached along with the tender and submit their bids accordingly.
Electrical work in c/w proposed stabling line for Critical Rolling stock (CRS) at Satroad Yard of Bikaner Division.
17-El-BKN-E-Tender-26-27~NWR
17-El-BKN-E-Tender-26-27
Open
Works - General
9 Months
Bikaner, Rajasthan
₹0
₹2.8 L
5 Oct 2026
5 Oct 2026
13 Oct 2026
91 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,37,51,931 | ||
| — | 6.00 | — | — | ||
| kmlmlmlSupply, erection, testing and commissioning of 16 Mtrs high mast shaft totally hot dip galvanized and suitable for wind velocity as per IS 875 part-3 as per spec Inspection: RITES, Inspection charges: Borne by Railways. | — | — | — | 11,96,976 | |
| — | 6.00 | — | — | ||
| Design and casting of suitable foundation with M-20 concrete for the 16mtr high mast having the safe soil bearing capacity at site as 10T/sqmtr at 2-meter depth including supply of foundation bolts manufactured from special steel along with nuts, washers and anchor plates and templates. Soil bearing capacity testing will be required before starting the work. Foundation design calculation & cube test is also required as per standard. Inspection: Consignee, Inspection charges: None. | — | — | — | 1,10,826 | |
| — | 36.00 | — | — | ||
| Supply installation testing and commissioning of 400W Flood light for high mast Input operating Voltage range and frequency 140 to 270 Volts AC at 50 Hz+/-2 Hz, Lumen/watt>/= 100 Lm/Watt, Power Factor 0.90, Working life for LED (Minimum 50,000 burning hours Reputed make like Philips/ Orient/ Edison/ Oreva/ HPL/Surya/ CG /Osram/ Bajaj/ Havells or equivalent reputed make as per tech spec. Inspection: Consignee, Inspection charges: None. | — | — | — | 2,63,196 | |
| — | 6.00 | — | — | ||
| Supply installation testing and commissioning of twin LED aviation obstruction lights with lamps as per spec. of reputed make. Inspection: Consignee, Inspection charges: None. | — | — | — | 23,352 | |
| — | 6.00 | — | — | ||
| Supply, fixing and commissioning of Switching Panel with electromechanical time switch with two daily dial / electronic time switch & two suitably rated contactors for operating 6 / 8 X 150 / 250 / 400 W LED flood lamps, suitable control gear for operation of lowering and lifting mechanism of 16 mtr mast necessary cable etc. for commissioning of the Mast. All the accessories should be of reputed make and the switch also incorporates electronic over current trip and latch mechanism. The panel shall be of appropriate size with sufficient clearance for working during maintenance and it should be properly installed near high mast with proper foundation. Height of panel shall be kept minimum 500mm above the ground. Inspection: Consignee, Inspection charges: None. | — | — | — | 64,194 | |
| — | 2000.00 | — | — | ||
| Supply of 4 x 70 sq. mm, 1.1KV grade, LT XLPE insulated PVC outer sheathed aluminium conductor armoured cable confirming IS: 7098 (Part-1) and as per tech spec. of reputed make Polycab/ Finolex/KEI /Havells/ RR Kabel /Universal/ V-Guard/ Anchor/ RPG/CCI or similar. Inspection: RITES, Inspection charges: Borne by Railways. | — | — | — | 6,08,000 | |
| — | 2000.00 | — | — | ||
| Laying, connecting, testing and commissioning of 4x70 sqmm, 1.1KV grade, LT PVC insulated PVC outer sheathed aluminium conductor armoured cable in trench/pipe as per spec (Cable will be supplied by railway). Inspection: Consignee, Inspection charges: None. | — | — | — | 26,000 | |
| — | 3000.00 | — | — | ||
| Supply of HDPE pipe conforming to IS 4984:2016, 50 mm dia, wall thickness 3 mm, PN 6 PE 80 under the road. Inspection: Consignee, Inspection charges: None. | — | — | — | 1,59,000 | |
| — | 3000.00 | — | — | ||
| Laying of HDPE pipe conforming to IS 4984:2016, 50 mm dia, wall thickness 3 mm, under the ground/road. The work involves laying of HDPE pipe along with transportation. Inspection: Consignee, Inspection charges: None. | — | — | — | 21,000 | |
| — | 3200.00 | — | — | ||
| Digging and filling of trench size 0.4 x 0.8 mtr as per spec. (trench work may be on kuchha/pucca land and all type of soil as per site requirement and without protective layer of brick) Surface of trench shall be made good in all respect and satisfaction of site engineer. Inspection: Consignee, Inspection charges: None. | — | — | — | 1,02,400 | |
| — | 18.00 | — | — | ||
| Supply, laying and fixing of GI pipe medium "B" class (Blue) confirming to IS 1239 part-I for passing incoming and outgoing cable from ground through it size 50 mm dia. Pipe should be of reputed make and as per tech. spec. Inspection: Consignee, Inspection charges: None. | — | — | — | 3,384 | |
| — | 19.00 | — | — | ||
| Supply and fixing of junction box size 390/388x305/304x170mm comprising of SMP/FRP material with rubber gasket, locking arrangement, zinc passivated earth bolt, etc. Make Sintex or similar with 4 no. aluminum busbar cap 200 Amp., suitable for 415 volt supply requirement. The box shall be fixed robustly with clamps at pole/ wall as per requirement. All the material should be of good quality. Inspection: Consignee, Inspection charges: None. | — | — | — | 33,060 | |
| — | 47.00 | — | — | ||
| Supply, installing, testing and commissioning earth electrode complete in all respect with perforated GI pipe medium "B" class (Blue) confirming to IS 1239 part-I length of 4 mtr., bore 50mm with all accessories like nut bolt, reducer nipple, wire meshed funnel and CC finished chamber covered by CI/RCC frame etc. Digging pit and refilling it with charcoal and salt in successive layers and connection with Strip and as per IS:3043, drawing attached as Annexure-I & testing of earth resistance as reqd. Inspection: Consignee, Inspection charges: None. | — | — | — | 77,268 | |
| — | 2.00 | — | — | ||
| Supply and fixing of 4 pole MCCB 100 amp. 25 kA with adjustable thermal and fix magnetic release complete with box. MCCB should be of reputed make and as per tech. spec. Inspection: Consignee, Inspection charges: None. | — | — | — | 41,412 | |
| — | 80.00 | — | — | ||
| Design, manufacturing, supplying and fixing of 110 V battery charging points as per specification and drawing. Inspection: Consignee, Inspection charges: None. | — | — | — | 1,14,720 | |
| — | 80.00 | — | — | ||
| Design, manufacturing, supplying and fixing of three phase 440 V pre-cooling points complete with 3P 80A MCCB, 63A 5 pin coupler (male + female) and accessories as per specification and drawing. MCCB and coupler should be of reputed make and as per tech. spec. Inspection: RITES, Inspection charges: Borne by Railways. | — | — | — | 7,64,320 | |
| — | 1000.00 | — | — | ||
| Supply of 4 x 50 sq. mm, 1.1KV grade, LT XLPE insulated PVC outer sheathed aluminium conductor armoured cable confirming IS: 7098 (Part-1) and as per tech spec. of reputed make Polycab/ Finolex/KEI /Havells/ RR Kabel /Universal/ V-Guard/ Anchor/ RPG/CCI or similar. Inspection: Consignee, Inspection charges: None. | — | — | — | 2,25,000 | |
| — | 1000.00 | — | — | ||
| Laying, connecting, testing and commissioning of 4x50 sqmm, 1.1KV grade, LT PVC insulated PVC outer sheathed aluminium conductor armoured cable in trench/pipe as per spec (Cable will be supplied by railway). Inspection: Consignee, Inspection charges: None. | — | — | — | 7,000 | |
| — | 610.00 | — | — | ||
| Supply of HDPE pipe conforming to IS 4984:2016, 75/80 mm dia, PN 6, PE 80 as per requirement. Inspection: Consignee, Inspection charges: None. | — | — | — | 51,240 | |
| — | 610.00 | — | — | ||
| Laying of HDPE pipe conforming to IS 4984:2016, 75/80 mm dia, under the ground/road. The work involves laying of HDPE pipe along with transportation. Inspection: Consignee, Inspection charges: None. | — | — | — | 6,710 | |
| — | 36.00 | — | — | ||
| Supply, laying and fixing of GI pipe medium density B class for passing incoming and outgoing cable from ground through it size 100 mm dia. Inspection: Consignee, Inspection charges: None. | — | — | — | 18,864 | |
| — | 400.00 | — | — | ||
| Supply of HDPE pipe conforming to IS 4984:2016, 110 mm dia, PN 6, PE 80 as per requirement. Inspection: Consignee, Inspection charges: None. | — | — | — | 1,28,800 | |
| — | 400.00 | — | — | ||
| Laying of Spun/MS/GI/DWC/HDPE pipe 100 mm to 200 mm by drilling of Horizontal bore by machine in Railway yard/below track/Road. Inspection: Consignee, Inspection charges: None. | — | — | — | 4,00,400 | |
| — | 2400.00 | — | — | ||
| Supply of 2 x 120 sq. mm, 1.1KV grade, LT XLPE insulated PVC outer sheathed aluminium conductor armoured cable confirming IS: 7098 (Part-1) and as per tech spec. of reputed make Polycab/ Finolex/KEI /Havells/ RR Kabel /Universal/ V-Guard/ Anchor/ RPG/CCI or similar. Inspection: RITES, Inspection charges: Borne by Railways. | — | — | — | 6,16,800 | |
| — | 2400.00 | — | — | ||
| Laying, connecting, testing and commissioning of 2x120 sqmm, 1.1KV grade, LT PVC insulated PVC outer sheathed aluminium conductor armoured cable in trench/pipe as per spec (Cable will be supplied by railway). Inspection: Consignee, Inspection charges: None. | — | — | — | 31,200 | |
| — | 2400.00 | — | — | ||
| Supply of 4 x 120 sq. mm, 1.1KV grade, LT XLPE insulated PVC outer sheathed aluminium conductor armoured cable confirming IS: 7098 (Part-1) and as per tech spec. of reputed make Polycab/ Finolex/KEI /Havells/ RR Kabel /Universal/ V-Guard/ Anchor/ RPG/CCI or similar. Inspection: RITES, Inspection charges: Borne by Railways. | — | — | — | 9,57,600 | |
| — | 2400.00 | — | — | ||
| Laying, connecting, testing and commissioning of 4x120 sqmm, 1.1KV grade, LT PVC insulated PVC outer sheathed aluminium conductor armoured cable in trench/pipe as per spec (Cable will be supplied by railway). Inspection: Consignee, Inspection charges: None. | — | — | — | 45,600 | |
| — | 4000.00 | — | — | ||
| Providing SH rail post 1.5 / 2.5 mtrs. Long for EFT & supporting cable tray. Work includes cutting of 50@47<47K47@90 lbs capacity rails in pieces of desired length (1.5/2.5 mtrs.), digging of pit and erection of rail pole (Rails will be supplied by railway and is to be collected by contractor from concerned SSE). The rail pole shall be erected over a cement concrete bed (1:3:6) of 15 cm thickness and back filling of pit with excavated earth soil. The depth of the pit shall be 0.5 mtrs. or as directed by Site Engineer. These rail poles should be grouted properly so that cable tray / EFT box are fixed in truly vertical position. Inspection: Consignee, Inspection charges: None. | — | — | — | 41,40,000 | |
| — | 1650.00 | — | — | ||
| Supply, erection and commissioning of cable tray made from MS angle 35x35x5 mm and MS flat 35x5 mm as per technical specification. Inspection: RITES, Inspection charges: Borne by Railways. | — | — | — | 7,22,700 | |
| — | 4.00 | — | — | ||
| Supply, installation, testing and commissioning of Battery charger rectifier set for input of 415 V 3 Phase, 50 Hz, AC and output of 110V-150V DC at 200 Amps. As per RDSOs latest specifications Inspection: RITES, Inspection charges: Borne by Railways. | — | — | — | 10,06,880 | |
| — | 2.00 | — | — | ||
| Design, manufacturing, supply, testing, erection and commissioning of LT panel made by 2 mm CRCA sheet with 1 no. Incomer 250A MCCB and Outgoing - 2 no. 4 pole MCCB 125 amps., 2 nos. 4 pole MCCB 63 amps. and 2 nos. 4 pole MCCB 40 amps. with meter & indication LED, copper bus bar etc. as per spec. with foundation. Inspection: Consignee, Inspection charges: None. | — | — | — | 2,34,684 | |
| — | 1.00 | — | — | ||
| Design, manufacturing, supply, testing, erection and commissioning of indoor LT panel, medium voltage(a) Incoming 2 x 630 amps.4 pole MCCB with microprocessor release having integral overload, short circuit, earth fault and neutral protection and breaking cap 70 kA (Ics = 100% Icu).(b) Outgoing 2 x 250 amps., 2 x 200 amps., 4 x 125 amps. and 7 x 100 amps. 4 pole MCCB with adjustable overload and adjustable short circuit trip unit and breaking cap. 50 kA (Ics = 100% Icu).(c) 1 x 630 amps. 4 pole Switch disconnector unit as bus-coupler.(d) 1 x 315 amps. 4 pole manual on load change over switch. Work includes formation of foundation for panel with suitable trench upto the satisfaction of the site engineer. As per technical specification. Inspection: RITES, Inspection charges: Borne by Railways. | — | — | — | 6,13,040 | |
| — | 800.00 | — | — | ||
| Supply of 4 x 240 sq. mm, 1.1KV grade, LT XLPE insulated PVC outer sheathed aluminium conductor armoured cable confirming IS: 7098 (Part-1) and as per tech spec. of reputed make Polycab/ Finolex/KEI /Havells/ RR Kabel /Universal/ V-Guard/ Anchor/ RPG/CCI or similar. Inspection: RITES, Inspection charges: Borne by Railways. | — | — | — | 8,16,000 | |
| — | 800.00 | — | — | ||
| Laying, connecting, testing and commissioning of 4x240 sqmm, 1.1KV grade, LT PVC insulated PVC outer sheathed aluminium conductor armoured cable in trench/pipe as per spec (Cable will be supplied by railway). Inspection: Consignee, Inspection charges: None. | — | — | — | 18,400 | |
| — | 4.00 | — | — | ||
| Supply, installing, testing and commissioning of copper plate earthing with connection complete in all respect with copper plate size 60 x 60 x 0.315 cm. Digging pit and refilling it with charcoal and salt and connection by copper flat. Masonry enclosure of 40 x40 x 30 cm.(inner), 12.5cm. should be provided at the top of the pit as per drawing and IS:3043. Inspection: Consignee, Inspection charges: None. | — | — | — | 18,580 | |
| — | Breakup for | details. | — | ||
| Concealed/surface wiring of Light/Fan/Exhaust/Call bell point with 1.5 sq. mm PVC insulated multi strand copper conductor cable and 1.5 sq mm PVC insulated multi strand earth copper cable voltage grade 1.1 kV conforming to IS: 694-1990 in existing conduit/casing capping for concealed/surface wiring including controlling switch, batten holder/ceiling rose as per requirement. All material should be of reputed make and as per tech. spec. Inspection: Consignee, Inspection charges: None. | — | — | — | 14,620 | |
| — | Breakup for | details. | — | ||
| Supply and fixing of socket as per specification. Inspection: Consignee, Inspection charges: None. | — | — | — | 2,370 | |
| — | Breakup for | details. | — | ||
| Supply and fixing of MS board manufactured by 1.6mm MS sheet duly finished with two coats of red oxide, earth terminal, 3mm sunmica sheet, zinc plated/ brass screw, cup washer etc in recessed, as reqd. Inspection: Consignee, Inspection charges: None. | — | — | — | 7,990 | |
| — | 500.00 | — | — | ||
| Supply and fixing of PVC conduit/casing caping (as per instruction of site supervisor) and its accessories, size 25 mm, thickness 1.6 mm as per IS 9537-part I. Inspection: Consignee, Inspection charges: None. | — | — | — | 18,500 | |
| — | 500.00 | — | — | ||
| Making and filling of chase for 25 mm dia PVC/MS conduit. Surface of chase shall be made good in all respect and satisfaction of engineer incharge. Inspection: Consignee, Inspection charges: None. | — | — | — | 3,500 | |
| — | 500.00 | — | — | ||
| Supplying and drawing 4.0 sq. mm PVC insulated multistrand copper conductor cable as submain and 1.5 sq. mm PVC insulated multistrand earth copper cable voltage grade 1.1 kV as earthing wire conforming to IS: 694-1990 in existing conduit/casing capping. Wire should be of reputed make and as per tech. spec. Inspection: Consignee, Inspection charges: None. | — | — | — | 19,000 | |
| — | 50.00 | — | — | ||
| Fixing of LED tube light complete. (Fitting will be supplied by Railway). Inspection: Consignee, Inspection charges: None. | — | — | — | 1,400 | |
| — | 10.00 | — | — | ||
| Fixing & commissioning of ceiling fan & regulator with nut bolt ensuring all safety aspects. Contractor is responsible for falling of fan within a period of 12 month. (Fan & regulator will be supplied by Railway.) Inspection: Consignee, Inspection charges: None. | — | — | — | 230 | |
| — | 1.00 | — | — | ||
| Supply and fixing of Double Door MCB DB SP 10 way (8+2 module), neutral and earth link, with one no. DP MCB 40-amp, one no. DP RCCB 40 amp. 30 mA and six nos. SP MCB 32/25/16/10 amp. 'C' series. Breaking capacity not less than 10 kA. MCB, RCCB and DB should be as per tech spec. and of same make. Inspection: Consignee, Inspection charges: None. | — | — | — | 5,163 | |
| — | 4.00 | — | — | ||
| Supply and fixing of single-phase Double Door MCB DB SP (4+2) way, with DP MCB 40 amp 'C' series one number & SP MCB 32/25 amp. 'C' series four number. Breaking capacity not less than 10 KA. MCB, RCCB and DB should be as per tech spec. and of same make. Inspection: Consignee, Inspection charges: None. | — | — | — | 10,552 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCwithACS10.pdf
ATTACHMENT
17-STDmilitaryline1.pdf
ATTACHMENT
CableCutJPOBikanerDivision.pdf JPO Cable cut
ATTACHMENT
CableCutJPOBikanerDivision.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .