Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹33.4 L+₹1.5 L (4.79%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹34.3 L+₹2.4 L (7.47%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹36.3 L+₹4.4 L (13.8%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹38.8 L+₹6.9 L (21.6%)Rejected-Finance LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
31 Aug 2022, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
REPAIR REPLACEMENT OF EXT WATER SUPPLY PUMP AND REWINDING OF MOTOR REPAIR MAINT OF SUMMER AND COOLING APPLIANCES AND REPAIR REWIRING OF INTERNAL WIRING AND LIGHT FITTINGS AT ADMIN AREA CPE ITARSI UNDER GE BHOPAL
2022_MES_543619_1
8915/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
ITARSI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹90,000
Yes
28 Sept 2022
5 Aug 2022
2 Sept 2022
5 Aug 2022
31 Aug 2022
19 Aug 2022
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
REPAIR/ REWIRING OF INTERNAL WIRING AND LIGHT FITTINGS AT ADMIN AREA CPE ITARSI UNDER GE BHOPAL
Taking down carefully aluminium / copper point wiring with surface/ concealed PVC conduit or wooden batten ( light, fan, socket, bell or power ) including sunk in cast iron / pressed steel terminal boxes except fitting such as switches, ceiling roses, lamp holders, sockets, regulators, call bells, light fittings of any sketch etc and making good disturbed surfaces of walls, floors etc complete all as specified and directed.
M&L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including concealed rigid non mettalic PVC conduit medium grade (Make of conduit : Presto Plast/Pressfit) not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall and making & maching the existing surface ) with 2.8 mm thick hylum brand laminated white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitable to fix modular cover plate with frame , concealed in wall or 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :-
(a) One light point/fan point controlled by one switch
(b) One socket outlet 5 Amps controlled by one switch on the same board.
(c) One socket outlet 5 Amps controlled by one switch on independent board.
(d) One bell / buzzer controlled by one bell push.
(e) One light point controlled by two way switch.
All as per item No.2.00 above but with 2.5 Sq mm multi stranded copper conductor cable for one 15 Amps socket outlet controlled by one switch on independent board and 1.5 Sq mm PVC insulated multistranded copper conductor cable as continuous earth wire complete all as specified and directed.
M&L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including surface PVC Casing Caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in cast iron / pressed steel terminal boxes (duly painted with two coats of anti corrosive paint out side and two coats of aluminium paint inside ) with 2.8 mm thick hylum brand laminated white bakelite sheet cover for mounting switches, sockets, fans regulators etc and 1.0 sq mm multi stranded copper conductor cable as continuous earth wire complete for the following :-
(a) One light point/fan point controlled by one switch
(b) One socket outlet 5 Amps controlled by one switch on the same board.
(c) One socket outlet 5 Amps controlled by one switch on independent board.
(d) One bell / buzzer controlled by one bell push.
(e) One light point controlled by two way switch.
All as per item No. 4.00 above but with 2.5 Sq mm multi stranded copper conductor cable for one 15 Amps socket outlet controlled by one switch on independent board and 1.5 Sq mm PVC insulated multi stranded copper conductor cable as continuous earth wire complete all as specified and directed.
Material and labour in repairs for Sub Main wiring with two single core 4 Sqmm multi stranded copper conductor, FRLS PVC insulated, unsheathed cable including rigid non metallic PVC conduit medium grade, ISI marked, 20 mm dia for sub main wiring including 2.5 sqmm FRLS PVC insulated and unsheathed stranded copper conductor as earth wire in surface/recess and making good to the disturbed surfaces to match the existing surfaces complete including taking down existing unserviceable sub main of any type and size all as specified and directed. Note:- Two runs of 4.0 Sq mm copper conductor cable, one run of 2.5 Sq mm copper conductor and one run of PVC conduit will be measured as one unit.
Material and labour in repairs for Sub Main wiring with two single core 6.0 Sqmm multi stranded copper conductor, FRLS PVC insulated, unsheathed cable including rigid non metallic PVC conduit medium grade, ISI marked, 20 mm dia for sub main wiring including 6.0 sqmm FRLS PVC insulated and unsheathed stranded copper conductor as earth wire in surface/recess and making good to the disturbed surfaces to match the existing surfaces complete including taking down existing unserviceable sub main of any type and size complete all as specified and directed. Note:- Two runs of 6.0 Sqmm copper conductor cable, one run of4.0 Sq mm copper conductor and one run of PVC conduit will be measured as one unit.
M&L for switch piano flush type pole one way 5 Amps, 240 V complete all as specified and directed.
M&L for Socket outlet 3 pin 5 Amps, 240 V flush type complete all as specified and directed.
M&L for piano flush type 5 Amps single pole two way complete all as specified and directed.
M&L for Switch piano flush type pole one way 15 Amps, 240 V complete all as specified and directed.
M&L for socket outlet flush type multi purpose 2 in 1, 3 pin 5 and 15 Amp, 230 Volts complete all as specified and directed.
M&L for ceiling rose surface bakelight two to three terminal complete all as specified and directed.
M&L for Lamp Holder, insulated body, with back plate for batten fitting complete all as specified and directed.
M&L for Electronic step type Fan Regulator/Mini switch type dimmer 120/280 Watt capacity including connecting up complete all as specified and as directed.
S&F 09 Watt LED bulb, in white colour with maximum Lumen output (850 lm) and colour temp 3000 K, complete all as specified and directed.
S&F 1 x 20 Watt LED tube light fitting prewired with all accessories and including LED tube rod 20 Watt 4 feet long inlcuding connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable 3 core of size 0.50 Sqmm complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F repair of switch piano flush type pole one way 5 Amps, 240 V complete all as specified and directed.
S&F in repair of Socket outlet 3 pin 5 Amps, 240 V flush type complete all as specified and directed.
S&F in repair and replacement of Bell push, flush type, 5 Amps complete all as specified and directed.
S&F in repair switch socket combination outlet flush type multi purpose 2 in 1, 3 pin 5 and 15 Amp, 230 Volts complete all as specified and directed.
S&F in repair and replacement of Ding Dong Bell AC, 240 Volts single pole complete all as specified and as directed.
S&F in repair of existing make Modular switch1 way 6A, 240 Volts 1 module complete all as specified and directed.
S&F in repair of existing make Modular switch 1 way 16A, 240 Volts 1 module complete all as specified and directed.
S&F in repair of existing make Modular Bell push 10A 1 module complete all as specified and directed.
S&F in repair of existing make Modular Socket, 6A - 5 pin combined 2 module complete all as specified and directed.
S&F in repair of existing make Modular Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
S&F in repair of existing make Modular Fan step regulator 120W, 240 Volts 1/2 module complete all as specified and directed.
S&F in repair 3 Pin, Plug Top 5/6 Amp, 220 volt complete all as specified and directed.
S&F in repair for 3 Pin, Plug Top 15/16 Amp, 220 volt complete all as specified and directed.
Supply only for replacement of unserviceable wire of size 1.5 sqmm single core FRLSH insulated multistranded copper conductor for working voltage 1100 volts sqmm complete all as specified and directed.
Description all as per srl item No 32.00 here in before but of size 2.5 sqmm.
Description all as per srl item No 32.00 here in before but of size 4.0 sqmm.
S&F in replacement of PVC insulated multistranded aluminium conductor twin core of size 6 sq mm, 1100 Volts grade heavy duty service cable, served with inner sheathing of PVC tape and over all PVC sheathed in service connections complete all as specified and directed.
S&F in replacement of Building Security light fitting LED 35 Watt energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source with toughened glass and impact resistance PF IK07 and GI pipe 40 mm dia, light grade for mounting bracket bent to shape 1.50 RM and fixing arrangement with two Nos of MS clamps set, nut bolts, washers of suitable size and fixing on wall/pole complete all as specified and directed.
S&F in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F in replacement of indoor 120 W Badminton Court Light, IP rating-IP66, cool white lighting color, single phase, frequency-50-60Hz, luminous intensity-15780 Lumens, 138 Lumen/Watt, colour temperature-6500K, LED Life-100000hrs including LEDs 115 Watt etc. complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F in replacement of recess mounted adjustable for LED15W Watt downlights made of extruded Aluminium housing and high power LED light source with Driver clear diffuser with separate electronic driver with complete accessories complete all as specified and directed. (Ceiling cutout size 180mm dia)
S&F in replacement of Surface LED15W Watt downlighter with white powder coated aluminium housing with integrated electronic driver complete accessories complete all as specified and directed.
S&F in replacement of LED flexi strip 24 watt (5 mtr each strip length) with electronic driver complete accessories complete all as specified and directed.
S&F in replacement of HEXA 10 W-IP-66 Bulk Head luminaries, with lamp holders, including one 1X 10W LED etc. complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ complete all as specified and directed.
S&F in replacement post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
S&F in repair on load change over switch 100 Amps, 4 pole, 415 Volts, 50 Hz with S S Enclosure complete all as specified and directed.
S&F in repair and replacement of sheet metal enclosure MCB DB 4 way tripple pole and neutral 415 Volts complete all as specified and directed.
Supply and fix in replacement of sheet metal enclosures for SPN DB's 240 volts, factory made double door flush type, IP-42 protection and all as per IS-8623, made from sheet metal 8 way 200 amps rated bus bar to be fixed with wall all accessories complete all as specified and directed.
S&F in replacement of Sheet metal enclosure single pole and neutral with a two pin and earth plug and socket with and including one single pole MCB 20 Amps 240 volts complete complete all as specified and directed.
S&F in replacement of MCB single pole 240 volts 6 to 40 Amps complete all as specified and directed.
S&F in replacement of MCB SPN 240 volts 16 to 40 Amps complete including taking down unserviceable fitting complete all as specified and directed.
S&F in replacement of MCB TPN 63 Amp 440 Volts including taking down unserviceable fitting complete all as specified and directed.
S&F in replacement MCB double pole 240 Volts 40 Amps complete all as specified and directed.
Note for item No 44 to 51 :- For MCB,s & MCB DB's, MCB shall be of 10 kA breaking capacity having 'C' characteristics as per IS-8828 with air circulating channels, bicontact terminals, dual position DIN rail clamps with IP-20 degree of protection, insulating sliding shutter, MCB for DB's shall be of same make of DB's, wiring cable shall be connected to MCB's with suitable lugs (Copper lugs for copper cable and aluminium lugs for aluminium cable)
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick and burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to a GI wire of size 4 mm dia by means of bolts , nuts, check nuts and washers connected to test poing or as directed including excavation and earth work in any type of strata, disposal of surplus soil to a distance not exc 50 mtrs, filling of adequate quantity of charcoal and common salt in alternate layers of 150mm each making PCC chamber by PCC 1:3:6 type C-1 and cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate 50mm thick duly reinforced with 8mm dia TMT bars 150 c/c and providing 20mm dia light grade GI pipe with funnel & wire mesh, necessary 15mm bore GI tube light grade for protection of GI earth wire 4mm upto test point etc complete all as shown in electrical plate No.3 of MES SSR Part-1 all as specified and directed. Note ;- GI wire and protection pipe upto 7.5 mtrs deemed including in the rate quoted.(Qty 7 Nos for rewiring and 04 Nos for Ext W/S)
REPAIR/ MAINT OF SUMMER AND COOLING APPLIANCES AT ADMIN AREA CPE ITARSI UNDER GE BHOPAL
Taking down carefully AC ceiling fan 1200mm/1400mm sweep, exhaust fan 300mm to 450mm sweep and wall moundted bracket fan 300/450mm sweep from their position complete for servicing such as removing dust and dirt from fan motor, washing blades with detergent powder including greasing to bearing, checking & replacing worn out screws with spring washers, rubber befit washers of fan blades, fan motor body, spilt pin/screw for fan down rod/check nuts as required for different makes of ceiling/exhaust fans to put fans fans to smooth and satisfactory working and refixing ceiling fan/exhaust fan after executing necessary servicing to their position connecting to electric system with suitable size of cable and testing, complete all as specified & directed. Note : Rates quoted by contractor shall deemed to be inclusive all minor items and no extra payment shall be admissible except for the items which are to be replaced which shall be measured and paid separately under respective item of Schedule 'A'.
Material & labour for preparation of old painted surfaces of ceiling fan, exhaust fan & wall mounting fan by scrubbing, cleaning with sand paper/wire brush etc making good surfaces and painting by applying synthetic enamelled first quality paint using spray gun in situ including filling cavities with filler and marking Srl No SM No / MES No with black paint, complete all as specified & directed.
Material and labour for rewinding of AC ceiling fan, 230 volts, 50 Hz, 1200mm/1400mm sweep of any make with appropriate gauge super enamelled copper winding wire including allied insulation material such as air drying insulation varnish, cotton tapes, lathered film paper, spacers, sleeves etc re-assembling at its position after repair, testing and commissioning, complete all as specified & directed.
Material and labour for rewinding of exhaust fan/wall mounted fan, 230 volts, 50 Hz, 300/450mm sweep of any make with appropriate gauge super enamelled copper winding wire including allied insulation material such as air drying insulation varnish, cotton tapes, lathered film paper, spacers, sleeves etc re-assembling at its position after repair, testing and commissioning, complete all as specified & directed.
Supply & fixing ball bearing 6202/6203 in replacement suitable for AC ceiling fan of 1200/1400mm sweep/ exhaust fan/ air circulation fan of any make to replace the unserviceable bearing including greasing as required, complete all as specified & directed.
Supply & fixing in replacement capacitor, 4/5 mfd 230 volts, AC, 50 Hz, complete all as specified & directed.
Supply & fixing in replacement capacitor, 2.5 mfd 230 volts, AC, 50 Hz, complete all as specified & directed.
Supply and fix in repair of split pin with hook, rubber and nut bolt of suitable for ceiling fan/exhaust fan of any sweep and make complete all as directed.
Supply and fix in repair of shaft of approved quality for ceiling fan/exhaust fan any make, type and size complete all as directed.
Supply and fix in repair of self lubricating bush of gun metal as per ceiling fan/exhaust fan complete all as directed.
Supply & fixing in replacement fan canopy, complete all as specified & directed.
Supply and fix in replacement of hanging rod 1ft/2 ft complete all as specified and directed
Supply and fix in replacement of fan blade 1200/1400 mm complete all as specified and directed
S&F in repair of Electronic step type Fan regulator (mini switch dimmer) 120/280 watt capacity including connecting up complete all as specified and directed.
Supply and fix in repair of PVC insulated, unsheathed three core copper flexible cable of size 1.5 sqmm including connection complete all as directed.
Taking down carefully Geyser of capacity 25/35 ltrs from its position for repair/servicing such as removal of dust, checking, replacing worn out parts, rubber etc, re-assembling at its position after repair, testing & commissioning & connecting to electric system with suitable size cable, complete all as specified & directed. Note : Rates quoted by contractor shall deemed to be inclusive all minor items and no extra payment shall be admissible except for the items which are to be replaced which shall be measured and paid separately under respective item of Schedule 'A'.
Supply & fixing galvanized iron water tubing, medium grade, 15mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., , fixed complete to walls and ceilings or laid in floors, complete including taking down all as specified and directed.
Supply & fixing galvanized iron water tubing, medium grade, 20mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., , fixed complete to walls and ceilings or laid in floors, complete including taking down all as specified and directed.
Supply & fixing geyser tank of capacity 25 ltrs, complete all as specified & directed.
Supply & fixing geyser tank of capacity 35 ltrs, complete all as specified & directed.
Supply & fixing heating element for geyser, 1500 watt, round type, complete all as specified & directed.
Supply & fixing heating element for geyser, 2000 watt, round type, complete all as specified & directed.
Supply & fixing heating element for geyser, 1500 watt, triangle type, complete all as specified & directed.
Supply & fixing heating element for geyser, 2000 watt, triangle type, complete all as specified & directed.
Supply & fixing thermostat suitable for geyser of any capacity, complete all as specified & directed.
Supply & fixing in repairs Angle stop valves, 15mm bore, fancy type, chromium plated with long shank and cup (concealed type), cast copper alloy, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specifed & directed.
Supply & fixing in repairs Bib tap, 15mm bore, fancy type, chromium plated , cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule, complete all as specified & directed.
Supply & fixing stainless steel connection 15mm dia, 900mm long with brass CP nuts and washers at both ends for hot water & Cold Water , fixed in repair, complete all as specified & directed.
Supply & fix in replacement ceiling fan complete with blades, down rods, electronic regulator and accessores , 230 V,1200 mm sweep with BEE 5 star rated BLDC type all as specified and directed by Engineer-in-Charge. Note:- Old fan shall be deposited in AGE store yard.
Taking down/out Deep freezer/Refrigerator transporting to contractor's workshop for carrying out repairs, taking out assembly, welding/brazing after detecting the leakage, as mentioned in respective items of Schedule including transporting back after repair, re-fixing at site, making it functional after replacement of worn out nuts, bolts, washer etc. including re-connecting electrical connection and testing, complete all as specified & directed. Note :- Cost of material and labour for providing new items shall be measured and paid for separately under relevant items of Sch 'A'.
Taking down/out Water Cooler of 40/80 ltrs and 60/120 ltr capacity transporting to approved workshop for carrying out repairs, taking out assembly, welding/brazing after detecting the leakage, as mentioned in respective items of Schedule including transporting back after repair, refixing at site, making it functional after replacement of worn out nuts, bolts, washer etc. including re-connecting electrical connection testing complete all as specified & directed. Note :- Cost of material and labour for providing new items shall be measured and paid for separately under relevant items of Sch 'A'.
Material & labour for preparation of old painted surfaces by scrubbing, cleaning with sand paper/wire brush etc making good surfaces and repainting by applying two coats of synthetic enamelled first quality paint using spray gun over over one coat of red oxide zinc chrome primer and marking Srl No SM No / MES No with black paint of following items :-
(a) Deep Freezer/Refrigerator/water cooler of capacity up to 320 Litres.
Supply and fixing in replacement of following unserviceable items of Deepfreezer/refrigerator of 300/310/320 litres as required at site including testing of the same, complete all as specified & directed :-
(a) MS condensing coil with fixing arrangement for 300/310/320 litres capacity complete with gas charging.
(b) Over load protector.
(c ) Thermostat switch (Auto defrost).
(d) Temp control knob with defrost push button.
(e) Electrical lamp pin/threaded type 15 watt, 240 volts AC supply.
(f) PVC ice tray of superior quality.
(g) Relay as per existing.
Supply, fixing and testing new compressor, single phase, 240 Volts, AC supply in replacement including cost of rubber bushes, bolts, nuts washers, copper tubing capillary tube, dryer filter terminal cover, thimbles, electrical wiring oil and gas charging (R-134 or as recommended by manufacture) and testing complete for the following including transportion etc :-
(a) Compressor of Deepfreezer/Refrigerator of cap 300/310 Ltr.
(b) Compressor of Water Cooler of capacaity 300/310 Litres.
Supply and fixing in replacement of following unserviceable items by opening of water cooler of 40/80 or 60/120 Ltrs capacity frost free for following replacement of unserviceable accessories and refixing, connecting and testing complete all as specified & directed :-
(a) Copper Condensing coil complete with fixing arrangement.
(b) Fan motor 1/2 HP, 240 volts, single phase AC supply.
(c ) Aluminium Blade for fan motor complete blower.
(d) Thermostat.
(e) Relay as per existing make.
(f) Over load protector.
(g) Float Valve brass 15 MM bore.
(h) Push type tap 15mm bore, brass chromium plated
Supply and filling/charging of following water coolers/Deep freezer with refrigerant R-22A/R-134 or as recommended by manufacturer including flushing out oil, vacuming, top up oil, brazing, leak detection, testing etc for following cooling appliances including replacement of capillary tube and dryer filter :- Note:-. The type of refrigerant gas shall be charged as per manufacturer recommendation.
(a) Water cooler 60/120 litres capacity.
(b) Deep Freezer/Refrigerator of capacity up to 320 Litres.
Supply and replacement of water lifting pump (water immersed) for desert cooler with model - HM - 09, 240 volts, 50 Hz, 40 watts, 1.5 metre max head and output 800 LPH complete all as directed.
Supply and fix in replacement of khas pads/wood wool pad of required size for desert cooler of any make complete all as directed.
Supply and fix in repair of blower motor, 230 volts, single phase, 50 Hz, suitable for desert cooler /Exhaust fan size 350/450 mm as per site requirement including kit consists of mounting clamps, blades, speed contol switch, nut, bolts and washers complete all as specified and directed.
Supply & fix in replacement of exhaust fan louver of any size complete all as specified and directed
Supply and Replacement/repair of voltage stabilizer of capacity 5 KVA installing and testing complete all as specified and directed.
Taking down defective Split/Window AC of 1.5 Ton capacity from any height and any places for repair and refixing at its original place after replacement of defective/wornout parts & making serviceable, complete all as specified & directed. Note:- Worn out spares parts required for making AC serviceable/functional shall be measured and paid separately under appropriate item as 'Supply only'.
(a) Supply only fan motor for 1.5 ton AC.
(b) Supply only AC compressor for 1.5 ton AC.
(c ) Supply and charging gas 22 R for 1.5 ton AC.
(d) Supply only AC copper pipe of size 8mm and 15 mm for 1.5 ton AC.
(e) Supply only 45 Mfd capacitor for 1.5 ton AC. Make.
(f) Supply only contactor, single phase, 30 Amp for 1.5 ton AC.
(g) Supply only fan belt for 1.5 Ton AC.
(h) Supply only printed circuit board of split AC/Window AC 1.5 ton
(j) Over load protector.
Maintenance for operationaly fit of RO based aqua guard installed for water cooler, with replacement of candle, Replacement of Membrane, Replacement of Pree filter candle, Replacement of Diaphragm Pump 24 volt DC and open flow minimum 2.0 Ltr/min checking of AC supply circuitary of aqua guard and made functional, replacement of step down transformer 230 volt to 12/24 volts, as per sample, incl servicig of RO complete all as directed at site.
Supply and fixing in repair/replacement of desert air cooler made up of MS sheet with copper wounde exhaust motor with capacitor, copper winded water pump 230V single phase, 50Hz and ON OFF switch, regulator, water tank capacity up to 75 ltr duly painted with double coated complete all as specified and directed. Note:- Old cooler shall be deposited in AGE store yard.
Dismantling and refixing the complete unit with new solar water heater plate (set of 5)/tube type of capacity 500 LPD installed at various sites complete all serviceable accessories including repairing/replacing all defective parts such as water tank, nuts, bolts, washers, drain plug, cleaning tanks, defective tubes and all other minor accessories as required at site including painting the solar water heater by rubbing the old paint and applying with two coats of synthetic enameled paint by spray painting where necessary and testing the same after repair all as specified and directed by Engineer-in Charge.
Supply & fixing the following items/spares in replacement for solar heaters of various capacities as mentioned in Srl No 99.00 here-in-before all as specified :-
(a) Heating element of capacity upto 2 KW (Electric rod) having rubber washer of size 1 ¼” or 1 ½” complete all as specified.
(b) Heating element of capacity upto 1.5 KW (Electric rod) having rubber washer of size 1 ¼” or 1 ½” complete all as specified.
(c) Glycol (Anti freezing solution) for filling in copper tubes complete all as specified.
(c ) Dead flange with nut, bolts and washers complete all as specified.
(d) Float valve assembly 15mm dia complete all as specified.
(e) Thermostat suitable for solar heater complete all as specified
(f) Hot water steel tank non stick 2mm thick with ceramic lining of capacity 500 Ltrs each including making necessary connections complete all as specified.
: REPAIR/REPLACEMENT OF EXT WATER SUPPLY, PUMP AND REWINDING OF MOTOR AT ADMIN AREA CPE ITARSI UNDER GE BHOPAL
Material and Labour for taking out of defective submersible pump set of capacity 10HP/12.5 HP of any make with column assembly of any size / capacity including disconnecting electrical and water line connection, lifting in with the help of chain pulley, clamp, tripod etc., and repairing, lowring and refixing the same after making it serviceable, rethreading of column pipe and replacement of worn out nuts, bolts washers, transportation of same from site to workshop and back etc., including test and commisionnig complete all as specified and directed. Note: (i) Defective spares parts for pump and column assembly shall be measured and paid separetely under relavent item. (ii) Cost of detaching the pump and motor removed and refixing after carry out the nessary repair shall be deemed to be included in the unit quated rate. (iii) After taking out submersible pump set the bidders shall cover the tube well imidiatly wihout any delay with cover/cap to avoid any accident and cots of covering the tube well shall be deemed to be included in the unit quated rate.
Material and labour for rewinding the submersiable motor of any make of capacity 10 to 12.5 HP with PVC insulated water proof conductor copper wire of best quality of existing gauge and turn with minimum weight of 1.2 Kg of copper wire per HP of motor and reassembling after replacement of bush, bearing sleeves, grinding as required and polishing of rotor shaft, repair to starter etc., and re fixing the same in existing position, test and commisionnig complete Including dismantling defective submersiable motor of any make complete all as specified and directed. Note:- Bush/bearing /sleeves/thrust plate shall be measured and paid separately under relavant items.
(a) Supply only bush/bearing (gun metal) of suitable size for 10/12.5 HP for the submersible motor complete all as directed.
(b) Supply only stainless steel sleeve of suitable size for 10/12.5 HP complete all as directed.
(c) Supply only thrust plate set 10/12.5 HP complete all as directed.
(d) Supply only thrust plate bearing housing
(e) Supply only rubber oil seal
Material and Labour for taking out of defective submersible pump set of capacity 7.5 HP of any make with column assembly of any size / capacity including disconnecting electrical and water line connection, lifting in with the help of chain pulley, clamp, tripod etc., and repairing, lowring and refixing the same after making it serviceable, rethreading of column pipe and replacement of worn out nuts, bolts washers, transportation of same from site to workshop and back etc., including test and commisionnig complete all as specified and directed. Note: (i) Defective spares parts for pump and column assembly shall be measured and paid separetely under relavent item. (ii) Cost of detaching the pump and motor removed and refixing after carry out the nessary repair shall be deemed to be included in the unit quated rate. (iii) After taking out submersible pump set the bidders shall cover the tube well imidiatly wihout any delay with cover/cap to avoid any accident and cots of covering the tube well shall be deemed to be included in the unit quated rate.
Material and labour for rewinding the submersiable motor of any make of capacity 7.5HP with PVC insulated water proof conductor copper wire of best quality of existing gauge and turn with minimum weight of 1.2 Kg of copper wire per HP of motor and reassembling after replacement of bush, bearing sleeves, grinding as required and polishing of rotor shaft, repair to starter etc., and re fixing the same in existing position, test and commisionnig complete Including dismantling defective submersiable motor of any make complete all as specified and directed. Note:- Bush/bearing /sleeves/thrust plate shall be measured and paid separately under relavant items.
(a) Supply only bush/bearing (gun metal) of suitable size for 7.5 HP for the submersible motor complete all as directed.
(b) Supply only stainless steel sleeve of suitable size for 7.5 HP complete all as directed.
(c) Supply only thrust plate set for 7.5 HP complete all as directed.
(d) Supply only thrust plate bearing housing for 7.5 HP complete all as directed.
(e) Supply only rubber oil seal for 7.5 HP complete all as directed.
Dismantling and opening of defective submersible pumping set having capacity up to 12.5 HP any stage/discharge and dismantling all spare parts by opening studs complete with machine/lathe ork/grinding/polishing and fitting of all spare parts and re-assembling installation in position after necessary repair / replacement of studs, nuts, bolts etc., including refixing the same after making it serviceable in its existing position including test and commisioning complete all as directed.o (Spare parts shall be measured & paid separately under respective items as under)
(a) Supply only submiersible pump bowl assembly of gun metal impeller
(b) Supply only submiersible intermediate bowl
(c) Supply only submiersible bowl bush (rubber)
(d) Supply only submiersible bowl bush (gun metal)
(e) Supply only submiersible cast iron impeller seal ring (neck ring)
(f) Supply only submiersible stainless steel running sleeves
(g) Supply only submiersible impellor locking keys stainless steel
(h) Supply only submiersible pump shaft 25.40 mm dia of any capacity
(j) Supply only rinning strainer for pump
Material and labour for taking out monblock/centrigugal/non clogging Motor Set of capacity 3 H.P to 7.5 HP from position and transportation of same from site to workshop and back, dismantling of cable/ pipe connection and reinstallation of motor set after necessary repairing on the existing foundation and making electrical connections including necessary nuts, bolts, washers etc., required at site of work, complete all as specified & directed Note : All spares parts required shall be measured and paid for separately
(a) Ball Bearing of suitable size
(b) Rubber washer of suitable size
(c) Packing sheet of suitable size
(d) Bush cover of suitable size
(e) Mechanical Seal of suitable size
(f) Circlips Clamp of suitable size
Material and labour for taking out Centrifugal/ non clogging/monoblock Pump of capacity 3 HP to 7.5 H.P and transportation of same from site to workshop and back, dismantling of cable/ pipe connection and reinstallation of pump set after repair on the existing foundation and making electrical connections complete all as specified and directed Note : All spares parts required shall be measured and paid for separately
(a) Pump overhauling GM bushes, shaft rematteling making key gland packing, replacement of coupling of pump/ motor of any existing size of heavy grade, incl all engineering work.
(b) Pump shaft stainless steel of same make and model duly grinded/polished
(c) Bearing of suitable size of pump
(d) Plugging leaks in casing by welding the same incl grinding for smooth surface
Material and labour for rewinding of damaged/burnt motor of capacity 3 H.P to 7.5 H.P any type by using enamelled copper wire of superior quality of existing grade and same Nos. of turns including varnishing ‘F’ class insulation and drying in heat chamber / oven including all other material / fittings and testing on completion, complete all as specified & directed.
Supply and fixing in replacement of CI Non Return Sluice Valves ISI Marked flanged class 1.6 PN with by-pass arrangement and necessary bolts and nuts of suitable size with and including rubber gasket for flanged joints and testing including taking out old unserceable non return valves complete of following sizes :-
(a) 100mm bore
(b) 80mm bore
Supply and fixing in replacement of CI Sluice Valves ISI Marked flanged class 1.6 PN with necessary bolts and nuts of suitable size with and including rubber gasket for flanged joints and testing including taking out old unserviceable sluice valves complete of following sizes :-
(a) 200 mm bore
(b) 150 mm bore
(c) 100 mm bore
(d) 80 mm bore
Supply and fixing in replacement of Gun metal globe, Ball or gate valve class-2 with iron wheel head screwed both ends for pipes of following sizes complete including taking down old unserviceable gate valves all as specified and directed :-
(a) 50mm bore
(b) 40 mm bore
(c) 32 mm bore
(d) 25 mm bore
(e) 20 mm bore
Supply and fixing in replacement of Cast Iron Foot Valve, conforming to IS-4038, complete suitable for pipes of following sizes complete including taking down old unserviceable foot valve all as specified and directed :-
(a) 63 mm bore
(b) 50 mm bore
Excavation in trenches not exceeding 1.5 mtr wide and 1.5 mtr in depth for laying of pipe lines and getting out old pipes in any type of soil all as specified and directed
Returning and filling in incl spreading, levelling watering and well ramming in layers not exc 25 cm in in any type of soil all as specified and directed.
Removal of excavated surplus soil at a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr from the starting point all as directed.
Taking up or down GI tubing & connection incl cleaning for re fixing and removal to site of following sizes complete includingtaking down old unserviceable gate valves all as specified and directed :-
(a) 100 mm bore
(b) 80 mm bore
(c) 50 mm bre
(d) 40 mm bore
(e) 25 mm bore
(f) 20 mm bore
Supply and fixing in replacement of Galavised iron tubing (GI), medium grade, with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminshing pieces, caps, plugs and unions etc., laid in trenches / fixed to walls and ceilings or laid in floors, complete all as specified and as directed of the following description :-
(a) 100 mm bore
(b ) 80 mm bore
(c) 50 mm bre
(d) 40 mm bore
(e) 25 mm bore
(f) 20 mm bore
Taking up or down CI water mains Pipe (including all fitting) of following sizes with spigot and socket/both side flanged ends and lead joints including burning out joints and recovering lead all as specified and directed :-
(a) 200 mm bore
(b) 150 mm bore
(c ) 100 mm bre
(d) 80 mm bore
Supply and fixing in replacement of Cast Iron pipe with the follwing sizes with spigot and socket/both ends flanged centrifugally cast Class LA , in any length laid in trenches/Over Head Tank with all fittings such complete all as specified and as directed of the following description :-
(a) 200 mm bore
(b) 150 mm bore
(c) 100 mm bre
(d) 80 mm bore
Material & Labour in replacement of lowering GI pipe heavy class of size 50mm dai bore with long GI socket in 3 meter length incudling taking down old GI Pipe. Make- Jindal/Tata/Swasticcomplete all as directed by Eng-In- Charge. (Note- All T&P required for execution will we arranged by Contractor).
M&L in replacing Gland for pump set capacity 2 HP to 10 HP complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair 15mm dia stop valves, cast copper alloy, screwed down high pressure with crutch or buterfly handle, screwed both ends for iron pipe or union and fixed all as specified and as directed, including taking down.
Taking down existing air release valve and supply and fix in repair CI air release valve 80 mm bore, ISI marked , rubber gasket , mild steel nuts, and washers including testing complete all as specified and directed.
Material and labour for cleaning RCC overhead water storage tank of capacity 50000 Gallon taking out sludge and depositing the same outside the Cantt area at a place meant for the purpose, removing all scale, dirt, algae, vegetation, remvoe honycomb on the wall of OHT if any and flushing after cleaning with water and bleaching powder, cleaning walls and floors by scratching with wire brushes and apply 2 coats of waterproofing SmartCare Epoxy TriBlock asian paints of maximum 250 Sqm area of inner side of the tank and also writing the date of Cleaning and capacity of the tank using synthetic enamel paint on black ground and white paint complete all as specifed and directed. Note : The work will be completed within 24 hours after that the water will be supplied to the users.
Material and labour for cleaning RCC overhead water storage tank of capacity 30000 Gallon taking out sludge and depositing the same outside the Cantt area at a place meant for the purpose, removing all scale, dirt, algae, vegetation, remove honycomb on the wall of OHTif any and flushing after cleaning with water and bleaching powder, cleaning walls and floors by scratching with wire brushes and white wash to be carried out in the inner side of the tank and also writing the date of Cleaning and capacity of the tank using synthetic enamel paint on black ground and white paint complete all as specifed and directed. Note : The work will be completed within 24 hours after that the water will be supplied to the users.
S&F in replacement Submersible flat cable PVC insulated and PVC sheathed LT 1100 volts grade with copper conductor of size 6 Sqmm 3 Core, complete all as specified and directed.
Supply, lay, connecting and testing in replacement of XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminum conductor,1100 volts with earthed system, 4 core, cross sectional area 25sqmm complete all as directed.
Material & Labour for well burnt brick Sub class B old size brick laying in trenches perpendicular to axis of cable all as specified and directed.
M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection (8 cm below cable & 15 cm above cable) complete all as specified and directed. [Note:-Compacted/punned thickness shall be measured & paid]
Material and labour run lead joint in wet/dry soil including removing necessary existing lead from the fittings of following sizes of pipes complete all as specified and directed. Note: Bidder should be ensure that any demages/casualities occured during removing the lead, bidder is the only responsible and no extra cost shall be deemed to quoted rate.
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
Supply and replacement of MS flange with rubber gasket suitable for following sizes pipes to the existing make and system including nuts, bolts and washers complete all as directed.
(a) 50 mm dia pipe
(b) 80 mm dia pipe
(c) 100 mm dia pipe
Supply and fix D joint alonwith rubber packing for CI pipe line for the following sizes including necessary excavation in wet condition cutting of pipes, stoping of water removing water and providing necessary extra fitting complete all as directed. Note: Earth work and D joint shall deemed to be included in the quoted rate and nothing extra shall be paid on this account.
(a) 80mm dia
(b) 100 mm dia
(c) 150mm dia
Cleaning the vegetation, rooting etc by spraying the water mixed chemical used for cultivation to avoid the grown up of vegetation etc complete all as directed. Note- Contractor shall ensure that on spraying of chemical vegetation shall be dried if not the same has to be again carried out with out any extra cost to department.
Material and labour for construction of valve pit chambers of size 600 X 600 X 600mm (internal dimensions) as under provided with 10 cm thick PCC 1:4:8 type D2 as in foundation over 15 cm thick hard core, 23 cm thick brick walls built in cement mortar 1:4, 15 mm thick internal plaster including top of floor, externally upto 150 mm below GL in CM 1:3 finished even and smooth without using extra cement, 3.00 mm thick MS sheet cover with 40 x 40 x 6 mm MS angle frame fixed in PCC 1:2:4 type B1, 50 mm thick coping with 25 x 6 mm flat iron hold fasts, hinges, handles, locking arrangements and applying 2 coats of syntheric enamel paint over acoat of red oxide primer to all steel surfaces and 3 coats of white wash to internal surfaces of chamber including excavation and earth work in any type of soil and removing of surplus soil to a distance not exceeding 50 m complete all as specified and directed.
All as per item No. 137.00 here in above but size 900 X 900 X 900mm.
Material and Labour for repair of leakage in the under ground GI pipe water line of following sizes including necessary excavation , dewatering with the kept of external pump and filling in wet condition, taking out of existing pipes/cutting of pipes, stoping of water, threading of pipes and providing of necessary GI fittings i.e. tee, elbow, socket, union if required complete all as directed. Note :- (i) GI fitting if required for stopping the leakage shall be supplied by the contractor without extra cost. (ii) Earth work for stoping the leckage shall be included in quoted rate (iii) The leakage will be rectified within 24 hours after that the penaltity charges @ 500/- per day deemed to the contractor.
(a) 20mm to 32mm dia GI Pipe
(b) 40mm to 50 mm dia GI Pipe.
(c) 80mm to 100mm dia GI Pipe.
Material and labour for repair of leakage in the under ground CI pipe water line of following sizes including necessary excavation and filling in wet condition, taking out of existing pipes/cutting of pipes, stoping of water, threading of pipes and providing of necessary CI fittings i.e. tee, elbow, socket, union if required complete all as directed. Note :- i) Earth work for stoping the leackage deemed to be included in quoted rate by the contractor.(ii) The leakage will be rectified within 24 hours after that the penaltity charges @ 500/- per day deemed to the contractor.
(a) 80mm to 100 mm dia CI Pipe
(b) 150 mm dia CI Pipe.
(c) 200 mm dia CI Pipe.
Material and labour for cutting the existing cast iron pipe150/100 mm dia for inserting 20/25/40/50 mm dia GI pipe, drilling, welding, and screwing with nuts, bolts, and washers with mild steel clamps welded with GI socket 20/25/40/50 mm dia including excavation of earth work, removal of soil and RFR complete all as specified and directed
M&L in repair CI fittings confirming to IS for Spigot socket end pipes up to 200mm bore such as bends (any type, radius angle) Tapers any type(straight,bend,increasing,descreasing or double socket etc)T pieces,single branch,`Y` junction,double branch cross (all sockets or socket and spigot)collars, caps and plugs etc. complete all as specified and directed
Material and labour for High strength Calcium based granular chlorination chemical containing appropriate quantities of dispersants / corrosion inhibitors to prevent encrustation / scaling in distribution systems. The brand and make of the chlorination chemical must be stated and certified by All India Institute of Hygiene & Public Health (Govt. of India), confirming compliance to all the above specifications with a declaration from the laboratory that from the technical, strength, stability, health, safety, and operational point of view, as well as the fact that this product is used for drinking water applications for consumption by humans, the brand and make of Calcium based granular chlorination chemical is suitable for drinking water chlorination and is recommended for use. The report must indicate that the sample has been drawn by All India Institute of Hygiene & Public Health complete all as directed. Make- as approved by GE
Repair to sluice valve with new accessories as per requirement like spindle and check nuts of sluice valve including nuts, bolts and rubber sheet complete suitable for 80 mm to 100 mm sluice valves complete all as specified and directed
Repair to sluice valve with new accessories as per requirement like spindle and check nuts of sluice valve including nuts, bolts and rubber sheet complete suitable for 150 mm to 200 mm sluice valves complete all as specified and directed
Supply and Fix MS Nuts, Bolts, Washers and clamps suitable for CI, GI and DI Pipes suitable for 40 mm dia to 200 mm dia Flanged joints as per site requirement all as specified and as directed by Engr-in-Charge.
Taking down old unsv MS Angle iron and materail and labour for fabricaion and fixing, bracings, supports, clamps and back plates fabricated from structural steel sections i.e M.S. channel or angle sections etc. including new nuts, bolts, washers as reqd dia/length in size, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive one primer coat of red oxide, one under coat and one finishing coat of black paint (1st quality ) as reqd complete as specified.
M&L for replacement of MS sheet covers of valve pit as per existing thickness, duly painted with one coat of redoxide paint as primer and two coats of synthetic enamel black paint over a redoxide paint incl fixing arragement with existing angle iron frame (hinges, welding, nut and bolts ) complete all as directed by Engr-in-Charge
M&L for repair of existing damaged brick walls in CM 1:6 of valve pits of size (900x900x600mm) incl 15 mm thick plastering in CM 1:4 for smooth finishing complete all as directed by Engr-In Charge
Supply, fix and commisioing of Chemical Dosing pump plunger type model RMPS-11 capacity 30 ltr /hr against 15 Kg Back pressure with its all accessories like injection, check valve , Y Strainer, PRV, suction/discharge tubing etc sutiable for chlorine and liquid dosing alongwith 100 Ltr FRP Solution preparation cum settling tank with lid, port hole, inlet/outlet/drain connection, sludge collection facility, level gauge etc and fitted with speed reducing motor and SS-316 agitator (FRP Coated for extra protection) CDS-100 Model RMCO including taking down of exisring dosing pump all as specifed and directed by the Engineer-in-Charge.
Development of tube well by means of pumping by air compressor of minimum pressure 10Kg/cm2 (compressor to be arranged by the contractor at his own cost) until sand free clean water is obtained at optimum yield complete all specified. Note :- Development of bore well (150 feet to 300 feet long),
Material and labour for replacement of water level indicator at Over Head Water Tank of capacity 50000/30000 Gallon at Adm Area CPE Itarsi including items like Iron/Wooden Board with marking with leveling, Float Valve, Wire and indicating level etc and completeall as specifiedand directed.
S&F in repair G.I union for 20/25/32 mm dia pipe, complete all as specified and directed.
S&F in repair G.I union for 40/50 mm dia pipe, complete all as specified and directed.
S&F G.I in repair union for 80 mm (3 inch) dia pipe, complete all as specified and directed.
S&F in repair G.I Nipple with length of 06 inch for 20/25/32 mm dia pipe, complete all as specified and directed.
S&F in repair G.I Nipple with length of 06 inch for 40/50 mm dia pipe, complete all as specified and directed.
S&F in repair G.I Nipple with length of 06 inch for 80 mm dia pipe, complete all as specified and directed.
Schedule of credit (calculation will be done off line) Rs. 121836.00
TANUJ CONST. CO.
M/s SHIVRATAN CONSTRUCTION
M/s Prayag Construction
PRAGATI ELECTRICALS AND ELECTRONICS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .