Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹17.1 LAccepted-AOC | 1 | Accepted-AOC L1 BIDDER | |
| 2 | 2₹17.3 L+₹23,342 (1.37%)Accepted-AOC | 2 | Accepted-AOC HIGHER RATES | |
| 3 | 3₹17.4 L+₹39,274 (2.30%)Accepted-AOC | 3 | Accepted-AOC HIGHER RATES | |
| 4 | 4₹18.2 L+₹1.2 L (6.95%)Accepted-AOC | 4 | Accepted-AOC HIGHER RATES |
Tender Value
Refer Docs
EMD Value
₹34,610
Closing Date
10 Oct 2023, 4:00 pmClosed
OFFICE OF THE EXECUTIVE ENGINEER EDIV KHANYAR
OFFICE OF THE EXECUTIVE ENGINEER EDIV KHANYAR
Renovation/Modernisation of Sub stations under Capex within the jurisdiction of EDIV Khanyar
2023_PDD_228131_1
EDIV/12 OF 2023-24
Open Tender
Electrical and Maintenance Works
Turn-key
14 days
RAINAWARI
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
EXECUTIVE ENGINEER EDIV KHANYAR
₹34,610
Yes
4 Dec 2023
31 Aug 2023
11 Oct 2023
31 Aug 2023
10 Oct 2023
31 Aug 2023
31 Aug 2023 - 31 Aug 2023
Supply, installation, testing and commissioning of:
Loading at Divisional strores , unloading at site Installation Testing Commissioning of 9 Mtr. Long Pole, ST-410 SP33 ( ST Poles to be provide by KPDCL and to be lifted from Divisional stores)
Supply , fixing of 11 kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply , fixing of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply , fixing of 11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type.
Supply , fixing of G.I Pipe of 150 mm dia 2 mtr long for Pole Butts including clamp fibricated out of 50x 8 mm flat GI Strip for sub station bed
Supply , fixing of GI Channel X-arm including clamps and braces ( fibricated out of 100X50X50X8 MM,75x40x40x 6 mm with top Bracket including clamp fibricated out of 50x 8 mm flat GI Strip for substation framw and transformer bedding
Supply , fixing testing and commissioning of 400 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
Supply , fixing testing and commissioning of 240 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
Supply , fixing testing and commissioning of 300 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
Loading at Divisional strores , unloading at site,erection , Installation testing and commissioning of of fixing of 50 mm² ACSR Conductor(conductor to be provide by KPDCL from Divisional stores)
Supply , fixing, testing and commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply , fixing, testing and commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply , fixing of Galvinized Nuts and Bolts
Supply , fixing of Danger Plates with Clamps
Anti-Climbing Device ( of Barbed wire with clamps )
Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm
Providing of Painting of poles with 2 each coats of Red Oxide & aluminum Paint with 1 liter of Redoxide and aliminum paint each
Providing of Cement bottoming 1:2:4 mix as per Standards 0.5 cum per pole complete with material & labour
Providing testing and conmmissioning of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing and fixing of Sundry items like aluminium lugs, Jumpers, binding Tape,
Dismentelling of existing Red Material and carriage from site to Divisional stores Khanyar Old Wooden poles As per acctual
Dismentelling of existing Red Material and carriage from site to Divisional stores Khanyar damaged cable, link sets, wooden cross arms ,Drop out sets ,and allied items as per actual.
M/S HILAL ENTERPRISES
M/S FAIRDEAL TRADERS
M/S MALIK CONSTRUCTIONS AND SUPPLIERS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .