| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.1 LAccepted-AOC 94A APR COLONY BILHARI JABALPUR MP | JABALPUR | MADHYA PRADESH | 482020 | L1 | Accepted-AOC lowest | |
| 2 | L2₹46.2 L+₹65,334 (1.44%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹46.5 L+₹97,375 (2.14%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹46.9 L+₹1.4 L (2.97%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹47.2 L+₹1.7 L (3.67%)Rejected-Finance NO 9 6 203 1 G2 DURGA BHAVANI NAGAR CHAMPAPET HYDERABAD 500059 | HYDERABAD | TELANGANA | 500059 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
25 Sept 2023, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
REPAIRS TO ROOF TREATMENT AND CONNECTED WORKS IN CERTAIN BUILDING IN RETRICTED AREA (ZONE A) OF KANCHANBAGH HYDERABAD
2023_MES_617285_1
GE I KBAGH TOKEN 66 OF 2023 2024
Open Tender
Civil Works
Item Rate
240 days
GE I R and D Kanchanbagh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹98,000
Yes
13 Oct 2023
5 Sept 2023
27 Sept 2023
5 Sept 2023
25 Sept 2023
19 Sept 2023
5 Sept 2023 - 12 Sept 2023
Amount
General Notes for item No. 1.00 to 30.00:- (i) water proofing treatment shall be carried out by authorised applicator only, necessary approval shall to be taken from GE before commencement of work. (ii) Material required for water proofing treatment shall be procured and kept in site before taking down old tratment, after removing old roof treatment shall be covered with water proof cover till laying new treatment. (iii) Mother slab, shall be made clean and neat by buffing to complete satisfaction of Engineer-in-charge.
M&L for Plain Cement Concrete Type B0 1:2:4 (using 12.5 mm graded stone aggregate) as in padding concrete, coving of vertical junctions on roof top incl dismantling old loose /cracked cement concrete including demolition of old concrete and removal of rubbish outside MOD Land complete all as directed by Engr-in-charge.
M&L for brushing neat cement slurry with 3 Kg of cement per Sqm over the RCC slab and sides complete all as directed by Engineer -in- Charge.
M&L for rendering 10mm in CM 1:3 over concrete surfaces on RCC roof slab and parapets mixed with WPC @ 3% by weight of cement shall be carried out complete all as specified and directed by Engr-in-Charge. Note : WPC will be measured under separate item of this schedule.
Supply only integral water proofing compound Make :- SCOTT /AQUA PROF/RAILIA
M&L water proofing treatment with polymeric standard membrane of weight not less than 3.50 kg per sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less than 150gms/sqm) laid over primed surface by forced application complete. Shall be fused uniformly by LPG torch flame on horizontal/vertical/slope surface on roof complete and preparation of surfaces of any description, over 10cm in width or girth otherwise described and appplying two coat of aluminium paint @100ml per sqm over APP membrabe sheet complete all as specified and directed dismantling of existing roof treatment including tar felt/cement plaster/concrete tiles/stone slabs/brick tiles etc from roof surfaces including cleaning the surface and removing the debris from site by Engr-in-Charge. Water proof treatment consist of as under: - (i) Applying one coat of bitumous primer conforming to IS 3384 @ 0.3 ltrs per sqm (ii) Laying APP based memberane as specified thickness and weight. (iii) Applying one coat of bitumen grade 85/25 @1.20Kg per sqm. (iv) Two coats of aluminium paint
M&L water proofing treatment with polymeric standard membrane of weight not less than 3.50kg per sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less than 150gms/sqm) laid over primed surface by forced application complete. Shall be fused uniformly by LPG torch flame on horizontal/vertical/slope surface on roof complete and preparation of surfaces of any description, over 10cm in width or girth otherwise described and appplying two coat of aluminium paint @100ml per sqm over APP membrabe sheet complete all as specified and directed dismantling of existing roof treatment including tar felt/cement plaster/concrete tiles/stone slabs/brick tiles etc from roof surfaces including cleaning the surface and removing the debris from site by Engr-in-Charge. Water proof treatment consist of as under: - (i) Applying one coat of bitumous primer conforming to IS 3384 @ 0.3 ltrs per sqm (ii) Laying APP based memberane as specified thickness and weight. (iii) Applying one coat of bitumen grade 85/25 @1.20Kg per sqm. (iv) one layer of cement concete tiles 250x250x22mm over 15mm screed bed in CM 1:4 Joints of tiles are filled with bituminious based grout
M&L for cutting grooves in brick wall 70mm wide and 65mm deep and sweeping horizontal face of groove with cement mortar (1:3) and making good in CM 1:3 after inserting membrane into the groove complete all as specified and directed by Engr-in-Charge.
M&L for cutting out cracks to 'V' - section in existing roof or terracing, cleaning out, wetting grouting with cement and sand slurry (1:3) .
M&L for providing, cement concrete (1:2:4) type B0 12.5mm graded aggregate as in roof kerbs or mud stops, rounded or chamferred on edges .
M&L for brick work built in CM (1:6) with sub clas 'B' fly ash bricks, old size bricks, straight or curved on plan exc 6m mean radius including demolition of exalt brick work complete .
M&L for rendering 15mm thick in cment mortor 1:6 on fair faces of brick work finished even and smooth w/o using extra cement including taking down old plaster complete all as specified.
M&L for preparation of new plastered surfaces and applying two coats of weather proof antifungal exterior paint as per manufacturers instructions over a coat of true care exterior wall primer over two coats of external birla putty 1.5mm thick each layer to level the surface and finished smooth with emery paper No.180 followed by emery paper No.320 or 400 and wipe it clean complete all as specified and as directed . Make:- APEX ULTIMA of ASIAN PAINT/ WEATHER COAT SMOOTH (BERGER PAINTS)/ WEATHER SHIELD MAX EXTERIOR ACRYLIC(DULUX)
Disconnecting existing tanks of exc 500 & n exc 1000 ltr capacity , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately)
Cleaning and removing all scale and dirt, etc, from tanks of exc 500 & nexc 1000 ltr capacity and from mouths of circulating pipes, etc
M & L 1000 ltr Rotational moulded polyethylene water storage tanks triple layered white in colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
Taking up or down steel tubing of 25 mm bore and connections, including cleaning for re- fixing or removal to store
Refixing old steel tubing of 25 mm bore and connections in new or old position (Walls, ceiling, floors, etc.)
S&F 25 mm bore Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors etc
Taking up or down steel tubing of 20mm bore and connections, including cleaning for re- fixing or removal to store
Refixing old steel tubing of 20 mm bore and connections in new or old position (Walls, ceiling, floors, etc.)
S&F 20 mm bore Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors etc
Taking up or down steel tubing of 15 mm bore and connections, including cleaning for re- fixing or removal to store
Refixing old steel tubing of 15 mm bore and connections in new or old position (Walls, ceiling, floors, etc.)
S&F 15 mm bore Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors etc
S&F in repair 20 mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
S&F in repair 25 mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
S&F in repair 25 mm bore Ball valves high pressure of PTMT with epoxy coat ed Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0mm-210gms./ 25mm-455gms)
Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks, etc., complete all as specified & as directed.
S&F PVC SWR pipe 110mm dia pipe single socketed in any length with rubber ring joints fixed to walls all as specified & directed.
S&F 110mm PVC (SWR )bends with access door of any radius all as specified & directed.
MVS ENTERPRISES
SUN LIGHT HOUSE
Maruthi international
M/S GDR CONSTRUCTIONS
Anjana corporation
shyam engineerings
PAVAN ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .