Additional Chief Engineer
Office Of The Additional Chief Engineer PHED Project Region Udaipur 313001 RMV Road Nearby Hotal Florance
Drinking WSP for 1473vill of Chittorgarh Pratapgarh Rajsamand Udaipur District Pkg1
2025_PHCJ_469956_1
ACEP-UDR-NIT No. 09/2024-25
Open Tender
Civil Works - Water Works
Chittorgarh
All Document Required as TD
8 documents required · 8 mandatory
₹2,500
EE PHED Project div Chittorgarh
₹8.5 Cr
Yes
Udaipur
19 May 2025
19 May 2025
17 Sept 2026
19 May 2025
16 Sept 2026
2 Jun 2025
28 May 2025
Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge. excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately
Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in- charge.(excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M.
HDPE PE-100 PN-6
63 mm dia
75 mm dia
90 mm dia
110 mm dia
Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply of pipe shall be in straight length in 6/12 M.
HDPE PE-100 PN-6
125 mm dia
140 mm dia
160 mm dia
180 mm dia
200 mm dia
225 mm dia
Providing, lowering, laying and jointing in trenches, standard lengths ISI marked Rigid PVC-O S/S Pipes (push on joints) as per IS-16647: 2017 (amended up to date) with EPDM Gasket seals on joints including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, laying of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
PVC-O pipe Class 500 PN-12.5
110 mm dia
160 mm dia
200 mm dia
Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. For Laying Pipe
1219 mm dia 10 mm thick
1219 mm dia 12.5 mm thick
Providing and applying 3LPE (3 Layer Polyethylene) tape coating conforming to ISO 21809-1, DIN 30670-91 or CAN/CSA Z245.20-10 to external surface of M.S. Pipe comprising of a layer of fusion bonded epoxy (FBE), overlaid with PE adhesive with an outer layer of high density polyethylene including preparation of surface by solvent cleaning, abrasive blasting to a finish of Grade 2.5 to DIN EN ISO 8501-1 and surface profile of 50 to 75 microns as per DIN EN ISO 8503-2. Minimum thickness of FBE shall be 250 microns including field joints coating at site complete as per technical specification and direction of Engineer-in-Charge. Minimum thickness of coating shall be 3.0 mm on weld seam as well as remaining surface.
Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in In charge. Liquid Epoxy shall be NSF/WARS approved for drinking water and minimum thickness of lining shall be 406 microns.
Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. Note: The rates for DI double flanged pipes shall be reduced 5%, if used other than OHSR pipes.
Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. for Paddle collar
813 mm dia 8 mm thick
1016 mm dia 10 mm thick
1219 mm dia 11 mm thick
2032 mm dia 16 mm thick
Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.
100 mm dia
150 mm dia
200 mm dia
250 mm dia
300 mm dia
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.
In all types of Soils
upto 1.5 m
Above 1.5 mtr and up to 3.0 mtr.
In Soft Rock
upto 1.5 m
Above 1.5 mtr and up to 3.0 mtr.
In Hard Rock (Blasting Required)
upto 1.5 m
Above 1.5 mtr and up to 3.0 mtr.
In Hard Rock (Blasting Probihited)
upto 1.5 m
Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand.
Supplying and Filling in plinth with river sand under floors including watering ramming consolidating and dressing complete including cost of sand
Carriage of material sand, bajri etc. upto 25 Km
Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date) Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, FloatLP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside .Fasteners - CS/ Galvanised steel, Outlet of big orifice will have a screen to prevent Tamper of float, with DI metal seated D/F Non rising stem. Sluice Valves as per (IS: 14846 amended upto date) PN 1.6 ratings. Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work
Class PN 1.6
50 mm dia
80 mm dia
100 mm dia
150 mm dia
200 mm dia
Construction of RCC pillar for following size of air valves including earthwork excavation, RCC M25 grade for base slab, vertical pillar, including cost of steel reinforcement ,GI (class-B)/MS vertical pipe, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as per direction of Engineer-in-Charge.
Air valve pillar for air valves size of 80mm dia
Air valve pillar for air valves size of 100mm dia
Air valve pillar for air valves size of 150mm dia
Air valve pillar for air valves size of 200mm dia
Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves for Scour Valve straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
Manually Operated CI Sluice valve of Class PN-1.0
400 mm with Gear
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical S
pecifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
80 mm dia
100 mm dia
125 mm dia
150 mm dia
200 mm dia
250 mm dia
300 mm dia
Manually Operated Resilient Seated Sluice Valves of Class PN 1.6
350 mm dia
400 mm dia
450 mm dia
500 mm dia
600 mm dia
1100 mm dia
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical S
1400 mm dia
100 mm dia
150 mm dia
200 mm dia
250 mm dia
Manually Operated Resilient Seated Sluice Valves of Class PN 1.6
350 mm dia
Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6
Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR "O "ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
Manually Operated Resilient Seated Sluice Valves of Class PN 1.6
350 mm dia
400 mm dia
450 mm dia
500 mm dia
Class PN 1.6, Manually Operated with Gear
700 mm dia
800 mm dia.
1000 mm dia.
1200 mm dia
400 mm dia
Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6
Class PN 2.5, Manually Operated with Gear
Manually Operated Resilient Seated Sluice Valves of Class PN 1.6
350 mm dia
400 mm dia
Class PN 1.6, Motorised Operated
700 mm dia.
80 mm dia
100 mm dia
125 mm dia
150 mm dia
200 mm dia
250 mm dia
300 mm dia
Manually Operated Resilient Seated Sluice Valves of Class PN 1.6
350 mm dia
400 mm dia
450 mm dia
500 mm dia
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0
80 mm dia
100 mm dia
150 mm dia
200 mm dia
250 mm dia
300 mm dia
Manually Operated Resilient Seated Sluice Valves of Class PN 1.6
350 mm dia
400 mm dia
450 mm dia
500 mm dia
Class PN 1.6, Manually Operated with Gear
Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (Fabricated Steel) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer.
800 mm dia
600 mm dia
1000 mm dia.
1000 mm dia
1100 mm dia
1600 mm dia
Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer.
150 mm dia.
250 mm dia.
350 mm dia.
400 mm dia.
450 mm dia.
Class PN 1.6
100 mm dia
150 mm dia
200 mm dia
250 mm dia
Manually Operated Resilient Seated Sluice Valves of Class PN 1.6
400 mm dia
Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per IS 5312 (part -1):2004 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS.Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR "O "ring seal Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) .Main girder & End Carriage fabricated from Rollled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches, LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer.
2 MT Capacity (Span 7 M and Lift 6 M)
5 MT Capacity (Span 7 M and Lift 6 M)
Construction of RCC Scour valve chamber dry type for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge.
For Class-A loading
Scour valve chamber of size1.13m x0.85m x1.95m for connecting pipe size-upto100mm
Scour valve chamber of size1.175m x0.95m x2.25m for connecting pipe size-more than 100 mm & upto150mm
Scour valve chamber of size1.2m x1.08m x2.45m for connecting pipe size-more than 150 mm & upto200mm
Construction of RCC Scour valve chamber dry type for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge.
Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as directed by Engineer-in-Charge.
Sluice valve chamber of size1.13m x0.85m x1.27m for pipe size-upto100mm
Sluice valve chamber of size1.17m x0.95m x1.415m for pipe size-from 125-to-150mm
Sluice valve chamber of size1.26m x1.185m x1.82m for pipe size-from 200-to-300mm
Sluice valve chamber of size1.39m x1.43m x2.185m for pipe size-from 350-to-450mm
Sluice valve chamber of size1.61m x1.75m x2.795m for pipe size-from 500-to-700mm
Sluice valve chamber of size 2.07 m x 1.83 m x 3.455 m for pipe size-from 700-to-1000mm
Sluice valve chamber of size 2.39 m x 2.05 m x 3.455 m for pipe size-from 1000-to-1300mm
For Class-AA loading
Sluice valve chamber of size 1.13 m x0.85 m x1.325 m- for pipe size-up to 100 mm
Sluice valve chamber of size 1.17m x 0.95m x1.47m for pipe size-from 125-to-150mm
Sluice valve chamber of size 1.26m x1.185m x1.88m for pipe size-from 200-to-300mm
Sluice valve chamber of size 1.39m x1.43m x2.245m for pipe size-from 350-to-450mm
Sluice valve chamber of size 1.61m x1.75m x2.85m for pipe size-from 500-to-700mm
Sluice valve chamber of size 2.71m x2.27m x3.455m for pipe size-from 1300-to-1600mm
Construction of RCC Sluice valve Junction chamber for different type of valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as directed by Engineer-in-Charge. For Class-A loading
Junction valve chamber of size 1.8 m x2.1 m x2.0 m- for pipe size-upto 150 mm
Junction valve chamber of size 2.0 m x 2.2 m x 2.3m for pipe size-from 150mm -to-300 mm
Design, construction, testing
and commissioning of Rapid Gravity Filter Treatment Plant including all relevant civil, electrical , mechanical ,instrumentation, automization and SCADA works, chemical building and stores along with ancillary civil works as defined in scope of work, technical specification and provisions of CPHEEO manuals for the following sizes .
At Harma KI Rel Village 174 MLD
80 mm dia
100 mm dia
125 mm dia
150 mm dia
200 mm dia
for Remaining 2909.0909 KLH
SITC of Bulk Flow Meter with removable mechanism class "B" confirming to ISO:4064:2005/ IS: 2373 of approved make of following dia sized pipelines and specifications complete: Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68, Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive, Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.
Construction of Village Transfer Chambers Room Type-A
150 mm dia
Construction of Village Transfer Chambers Room Type-B
Providing, Supplying and fixing of D/F DI Pressure Reducing Valve in pipe line including jointing etc. complete as per standard/ technical specification and direction of Engineer-in-Charge
Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.
Bituminous courses
Granular courses
Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.
Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.
Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.
Plain cement concrete pavement of M-30 Grade
Removing & Re-fixing of Bricks Kharanja road by manual means for laying of pipe line, stacking of serviceable & unserviceable material separately, disposal of dismantled material lead up to 50 mtr. The Bricks interlocking be laid on average 12 mm thick bed of mud mortar and the joints to be filled with pointing in cement mortar 1:3. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the direction of Engineer in charge. The rates are inclusive of fixing of 80 percent reusable Bricks and cost of required new First class FPS bricks (min. 10.5 Mpa) in place of damaged bricks, all lead and lift as per Technical Specifications and direction of Engineer in Charge. Note: If existing bricks used more than 80%, than for every 1% above 80% use, deduction of 1% in cost shall be done for every 1% use above 80%.
Horizontal aligned Bricks
provision of Surge Proctection system as per L section and details Techanical specification in the Bid Document including Vetting charge including approval charges
provision of Cathodic proctection for temporary and permanent arrangement
Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. Providing M-30 grade concrete by using cement as per codal provision instead of M-20 grade design mix.
Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc.
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code)
Providing Household Tap Connection as per technical specification and approved drawing as per relevant IS code (amended up to date) from HDPE/uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PP mechanical Integrated saddle with inbuilt flow control valve made out of SS316 designed for 5 LPM discharge at 0.5 bar pressure , not exceeding the flow of 7 LPM at 2 bar and a compression elbow, moulded in single piece/ fusion welded (Complete job) including digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including GM Full-way Valve (IS:778 Mark) or wheel valve and specials with 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using PPR-C pipe with standard PPR fittings/ GI pipes in the premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.
For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr.
P& F Bib cock (IS : 8931 mark), superior quality of approved make , brss 400 gm, 15 mm nominal bore.
Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be done by using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.
Add extra over item no 1.21 & 1.22 for providing 20 mm PE 80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr.
Providing and laying in position specified grade of reinforcement cement concrete all RCC structural elements upto plinth level including curing compaction finishing with rendering in cement sand mortar 1:3 ( 1 cement : 3 coarse san
d) and making good the joints excluding the cost of centering shuttering and reinforcement M20 Grade nominal mix (with graded stone aggregate 20 mm nominal size) For Vertical Post
Construction of Pump house of RCC framed structure with pump pit in RCC walls as per scope of work and technical specification complete work in all respect including electrical works for indoor and outdoor lighting and fans, rain water drainage, sanitary, plumbing, monorail/ EOT crane etc. complete as per direction of Engineer-in-charge. The GA, structure, electrical, sanitary, P&ID, SLD to be prepared by the contractor and submitted to department for approval for earth quake zone II.
IPS-1/CPS WTP HARMARA KI REL
IPS-02 CPS MATA KHERA
IPS-03CPS RANDIYABADI
Construction of Pump house of RCC framed structure as per approved standard GA, structure, electrical drawing, scope of work and technical specification complete work in all respect including electrical works for indoor and outdoor lighting and fans, rain water drainage, sanitary, plumbing, monorail/ EOT crane etc for Earth quake zone II and SBC equal to or more than 7 T/sqm. Note: Standard drawings can be viewed on website https://pheddms.rajasthan.gov.in/private/public/dms_document.aspx.
Type I ( 72.3 Sqm)
Type II ( 111.34 Sqm)
Type III ( 150.6 Sqm)
Type IV ( 212.9 Sqm)
Type VI ( 407.48 Sqm)
Supply erection testing and commissioning of pumps & motors of approved duty conditions as perscope of work and specifications given in the tender document.
IPS-05 CPS GADRIYAWAS Route, 88 LPS/140 m head/(2W+1S) of 200 KW
CPS-05 PEEND, CPS-06 LINKODA ,BADI SADRI TOWN TP,CPS-07 PANDERA, CPS-08 GUMANPURA, IPS-02/CPS MATA KHERA Route, 293 LPS/160 m head/(6W+3S) of 633 KW
CSCL-11,13,14 Route, 23 LPS/115 m head/(1W+1S) of 55 KW
CSCL-7,8,12 Route, 13 LPS/130 m head/(1W+1S) of 37 KW
CSCL-1,2,4, (4) Route, 18 LPS/65 m head/(1W+1S) of 22 KW
NCL-8,9,10 Route, 17 LPS/60 m head/(1W+1S) of 22 KW
NCL-11,24,12 Route, 18 LPS/60 m head/(1W+1S) of 22 KW
BSCL-3,26 Route, 15 LPS/75 m head/(1W+1S) of 22 KW
CPS-9,10,11,1,2,13,14 IPS-3 Route, 92 LPS/145 m head/(6W+3S) of 200 KW
BHCL-10,15,1617,18,19,20 (5) Route, 31 LPS/100 m head/(1W+1S) of 75 KW
RCL-01,11,12 (4) Route, 18 LPS/70 m head/(1W+1S) of 30 KW
RCL-03,04,05(4) Route, 16 LPS/65 m head/(1W+1S) of 22 KW
RCL-09,19,20,21 Route, 15 LPS/70 m head/(1W+1S) of 22 KW
Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at syncronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions. Note: Duty condition of required pump shall also be mentioned in BoQ.
CSCL-19,20,22,23 Route, 26 LPS/75 m head/(1W+1S) of 37 KW
CSCL-3,5,6,9,10 Route, 21 LPS/60 m head/(1W+1S) of 30 KW
CSCL-17,18,21,22,25 Route, 17 LPS/55 m head/(1W+1S) of 18.5 KW
CPS-01 GOTHRA,CPS-1A NARANI,CPS-02 Bamaniya, CPS-2B Lasrawan,CPS-2C KALYANPURA Route, 166 LPS/65 m head/(1W+1S) of 160 KW
CPS-3 & CPS-4 Route, 38 LPS/45 m head/(1W+1S) of 37 KW
NCL-14,15,18,19,20 Route, 26 LPS/60 m head/(1W+1S) of 30 KW
BSCL-09,10,11,12,13,14(6) Route, 25 LPS/80 m head/(1W+1S) of 45 KW
BSCL-01,04,05,06 Route, 23 LPS/75 m head/(1W+1S) of 37 KW
BSCL-08,16 Route, 22 LPS/55 m head/(1W+1S) of 30 KW
BSCL-20,22,23,24,25,26 (7) Route, 37 LPS/65 m head/(1W+1S) of 45 KW
BSCL-7,15,18 Route, 23 LPS/50 m head/(1W+1S) of 22 KW
DG-1,8,12,15,18,26 Route, 43 LPS/67.85 m head/(1W+1S) of 55 KW
DG-3,4,5,6,16 Route, 22 LPS/67 m head/(1W+1S) of 30 KW
BCL-01,02,03,11,30 Route, 31 LPS/50 m head/(1W+1S) of 30 KW
BCL-04,05,06,08,07,09 (7) Route, 30 LPS/60 m head/(1W+1S) of 37 KW
BCL-26,27,28,29,30 Route, 28 LPS/40 m head/(1W+1S) of 22 KW
DGCL-09,10,25 Route, 23 LPS/70 m head/(1W+1S) of 30 KW
DGCL-18,19,20,23,27 Route, 35 LPS/45 m head/(1W+1S) of 30 KW
DGCL-02,11,21,29 (7) Route, 26 LPS/65 m head/(1W+1S) of 37 KW
DGCL-7,13,14,19 Route, 26 LPS/65 m head/(1W+1S) of 37 KW
BHCL-17,25,26,27,28 (6) Route, 21 LPS/65 m head/(1W+1S) of 30 KW
BHCL-01,02,03,04,05,06 (7) Route, 28 LPS/80 m head/(1W+1S) of 45 KW
BHCL-07,08,09,11 (6) Route, 28 LPS/65 m head/(1W+1S) of 37 KW
CPS-15 Akola, CPS-16 Raypuriya Route, 97 LPS/55 m head/(1W+1S) of 90 KW
CPS-17 Tara Khedi, IPS-4 Route, 85 LPS/70 m head/(2W+1S) of 90 KW
KPCL-07,11,17,26,28 (6) Route, 28 LPS/50 m head/(1W+1S) of 30 KW
KPCL-04,12,13,14,15(6) Route, 34 LPS/75 m head/(1W+1S) of 55 KW
KPCL-01,02,03,05,09 (7) Route, 38 LPS/45 m head/(1W+1S) of 37 KW
Cps-18 & 19 Route, 70 LPS/55 m head/(1W+1S) of 75 KW
RCL-14,15,18,25,27 (7) Route, 28 LPS/60 m head/(1W+1S) of 37 KW
RCL-22,23,24,26,28 (6) Route, 27 LPS/65 m head/(1W+1S) of 37 KW
SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection with existing pipeline including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.
EFM100 mm
EFM 150 mm
EFM 200 mm
EFM 250 mm
EFM 300 mm
EFM 400 mm
Providing, lowering, aligning & fixing in position DI D/F Plunger Type Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications: Body- Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or EN-JS 1030, Plunger/ Piston - Stainless steel AISI- 304/ Gr 1.4301, Piston Guides- Bronze Welded Overlay / SS Shaft/Crank/Spindle- Stainless steel AISI- 410/ Gr 1.4021 Body Seat Ring- Stainless steel AISI- 316/304/ Bronze IS:318- LTB2 ,Seal ( O- ring / Quad ring)- EPDM/ NBR, Bearing Bush - Bronze IS:318- LTB2,Slotted cylinder / Strainer / Diffuser- AISI- 420/ 304,Nut- Bolts - SS, Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16
.5, Class 150 and Class 300/ EN-1092-2. Insertion rubber of black EPDM 6mm thick ,Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied both inside and outside . Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- Charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
Plunger Type Flow Control Valve
100mm dia
200mm dia
250mm dia
d) and making good the joints excluding the cost of centering shuttering and reinforcement M20 Grade nominal mix (with graded stone aggregate 20 mm nominal size) For Vertical Post
Construction of Flow Meter Chamber in required size and shape as per drawing including required excavation of earth in all types of soil such as murrum, sand, sandy silt, black cotton soil, hard soil, kankar and all types of rocks etc.,disposing of surplus excavated material within a lead of 50 meters. The work includes laying of 100 mm thick plain cement concrete 1:4:8(1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) in bedding and foundation, construction of 150 mm thick RCC walls in M-20 grade C.C., covering it with class -A loading ferro cement covers of required sizes and complete with removal of excess material and making clean the site upto the satisfaction of Engineer in charge
Design & Construction of clear water Reservoirs of required capacity at following places, including its piping, fittings, etc complete in all respect as per the scope of work & specifications given in tender document
WTP/IPS-01 CPS Harmara ki rel
IPS-05 CPS GADRIYAWAS
IPS-03 CPS Randiyardi
CPS-1 BARWALA DEWAL
CPS-07 PANDERA
CPS-09 BHATOLI GUJRAN
CPS-10 AKOLA KHURD
CPS-15 Akola
CPS-16 Raypuriya
CPS-17 Tara Khedi
CPS-18 Gokulpura
IPS-06/CPS BAMANIYA
IPS-04/CPS BHIMAGARH
Construction of RCC (Dome type) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: -
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. . b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.
h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2 & 3.
CPS -02 NARANI
CPS-3 Lasrawan
CPS-4 KALYANPURA
CPS-05 LINKODA
CPS-06 Peend
CPS-8 GUMANPURA
CPS-11 MANDHIYA
CPS-12 NARDHARI
CPS - 13 BHADSODA
CPS-14 Jawanpura
CPS-19 Gurjaniya
Construction and commissioning of RCC flat slab Over Head Service Reservoir of following capacity and staging including all material and labour charges as per the Scope of work and Technical Specification, consisting of the following main activities: -
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface roof slab, and 600 mm height of the vertical wall. e) Successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the roof slab. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top Slab to bottom Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony and MS ladder with safety cage from balcony to top slab.
j) Providing and fixing water level indicator (float type). k) Providing and fixing of hand railing all around the balcony, roof and staircase, consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm p) CI/DI puddle collar shall be fixed in the bottom/slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 15 M
50 KL, staging Height 15 m (1-Nos.)
Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: -
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection al
l around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall. e) Conducting successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab. j) Providing and fixing water level indicator (float type).
k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm. p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II 18 M Staging
100 KL, staging Height 18 m
150 KL, staging Height 18 m
200 KL, staging Height 18 m
250 KL, staging Height 18 m
300 KL, staging Height 18 m
Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II 20 M Staging
100 KL, staging Height 20 m
150 KL, staging Height 20 m
200 KL, staging Height 20 m
250 KL, staging Height 20 m
Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II 22 M Staging
100 KL, staging Height 22 m
150 KL, staging Height 22 m
200 KL, staging Height 22 m
250 KL, staging Height 22 m
300 KL, staging Height 22 m
Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 24 M
100 KL, staging Height 24 m
150 KL, staging Height 24 m
200 KL, staging Height 24 m
250 KL, staging Height 24 m
Construction of RCC Dome type Ground Level Service Reservoir (GLSR) of following capacity as per the Scope of work and Technical specifications, consisting of the following main activities: -
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work. c) All the GLSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall giving. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from top bottom Slab inside container. Providing and fixing water level indicator (Float type).
i) Providing and fixing MS ladder from ground to top slab with safety cage. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipe of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
Rates for RCC GROUND LEVEL SERVICE RESERVOIR SEISMIC ZONE-II & III and SBC18T/sqm
50 KL capacity
100 KL capacity
150 KL capacity
200 KL capacity
Providing and fixing of flanged/ plain ended MS special of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depth in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.
MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet)
Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below: 1. Depth of foundation- 900 mm. 2. PCC in M-10, width -900 mm and thickness 100 mm, 3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonary in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm. 5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6. 6. Expansion joint shall be on every 30 mtr. 7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided. 8. Pillar for main gate 350x350 mm in size is part of boundary wall. 9. Cement paint of approved colour in 3 coat shall be done.
Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints.
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 Mtr. in width as well as 10 Sqm on plan including disposal of excavated earth upto 50 Mtr. and lift upto 1.5 Mtr. disposed soil to be levelled and neatly dressed : All Kind of spoil
Supply of dry manure including loading unloading transportation & stacking at site :
Goat dungmanure.
Supply of different varities of tree/ shrubs/ climbers according to height and age of the plant at site including loading/ unloading & transportation etc. complete :
Different varities of Climber 900 mm to 1500 mm
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering
- All work up to plinth level.
M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing up to floor five level pre cast cement concrete string or lacing courses, copings, bed plates, anchor blocks, windows sills, shelves, louvers steps, staircases, etc. including carriage, hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand) cost of required centering, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) on exposed surface, including all T & P, curing etc. complete: M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
Supply and erection of M S swaged tubular pole conforming to IS: 2713-1980 (part I to II) with galvanised base plate in position including excavation of the pit and filling the same with C.C. of M-20 grade (1:1.5:3) from base plate to 50 cm above ground level, with the help of steel frame not less than 40 cm dia up to 114.3mm outer dia and 50 cm beyond 114.3mm outer dia around the pole. Duly finished with cement plaster, earthing terminals, cable entry, GI cable sleeve complete as required. After eraction pole shall be painted with two coat of red oxide primer and two quote of enamel paint of silver colour as per the direction of Engineer incharge.The pole shall be fabricated by using ISI mark tube for structural purpose of following height & designation. ( See Table P - 02 for specs. ) complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure "A" attached with this BSR 7.5 mt high
Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) andsecondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A"attached with this BSR LED Street Light fixture 45 Watt
Providing and laying XLPE/PVC insulated & PVC sheathed Unarmoured control cables of 1.1 KV grade with copper conductor as per IS 1255 including excavationj of 30 CmX75 Cm size trench 25 Cm thick under layer of sand and Iind class bricks covering 4C x 2.5 sq.mm
Providing and fixing cow catcher made of R.S. joist angles channels MS rounds including cutting welding and fabrication with priming coat of red oxide (as per design).
Construction of Soakage well in all types of soil 300mm thick dry stone masonry, top and bottom 300 mm course in CM 1 : 6, 80 mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C. flooring earthwork complete as per approved drawing including disposal of earth within a lead of 50 Mtr.
Providing and fixing cow catcher made of R.S. joist angles channels MS rounds including cutting welding and fabrication with priming coat of red oxide (as per design).
Size 300 cm dia outside & 300 cm depth
Construction of Septic Tank in all types of soil with 40 Cm. thick masonry in CM 1 : 6, 15 Cm. thick C.C. bed of 1 : 5 : 10, M-15 grade C.C. flooring & over stone slab covering, 80 mm thick slab, jointing of slab in CM 1 : 3 Ralthal, Kharanja, 50 mm thick stone partition walls, 20 mm thick plaster in CM 1 : 6 finished with neat floating cement, 4 Nos C.I. foot rests of approved design, two No. 450 mm dia 25 Kg. of each C.I. cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 Mtr.
Size 400 x140x150 cm.(for 50 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 10mm ϕ @15 cm c/c bothways including shuttering complete in all respect.
Providing Laying & Jointing glazed S.W. pipes grade "A" (IS : 651 Marked) of approved make with spun yarn & stiff mixture of cement mortar 1:1 excavation & refilling of earth in all types of soil upto 1.2 m. depth, S.W. fittings, including testing of joints etc. complete.
150mm dia
Providing and Laying C.C. 1 : 5 : 10 (stone aggregate 40 mm nominal size) all around S.W. pipe including 15 cm. thick bed concrete as per Rajasthan PWD specifications : (Width W = Diameter of pipe in Cm + 40 Cm.). (Excluding cost of pipe )
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 Mtr. in width as well as 10 Sqm on plan including disposal of excavated earth upto 50 Mtr. and lift upto 1.5 Mtr. disposed soil to be levelled and neatly dressed : All Kind of spoil
Providing and fixing G.I. pipes (External Work) with G.I. fittings (IS : 1239 Mark) including trenching & refilling earth etc.
Supply of dry manure including loading unloading transportation & stacking at site :
Goat dungmanure.
25mm dia nominal bore
Providing and fixing Ball Cock (IS : 1703 Mark) with Rod & P.V.C. Ball complete.
Brass wt.Not less than 1000 gm 40mm.:
Laying of lawns including ploughing leveling breaking of clods manuring and removal of stones etc. (cost of manure or extra good earth to be paid separately )maintenance of lawn foe 30 days or more till the grass forms a thick lawns free from weeds and fit for moving in the duration of planting if lawn die some where the contractor will replant it at his own cost
in rows 5 cm apart in either direction
Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of
plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion)
Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification .
75mm thick.
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M20 grade Nominal Mix / Design Mix
75mm thick.
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :
Columns, pillars, posts and struts etc.
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :
Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :
Brick masonry with F.P.S. bricks of class designation 75 in foundation and plinth with bricks
Cement mortar 1 : 6 (1 cement : 6 coarse sand)
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :
Half brick masonry in foundation & plinth using bricks of designation 75
Cement mortar 1 : 4 (1 cement : 4 coarse sand)
Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75
Brick work in partition in super structure upto five storey 7cm. thick (brick on edges) using bricks of class designation 75 in :
Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete. Hot finished seamless type tubes.
Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :
Windows side hung /Ventilators top or centre hung (openable)
Partly fixed and partly openable [ fixed area not to exceed 33%]
Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance.
Providing and fixing Square bars or other flat welded to window, ventilatiors etc.
Brick on edge flooring with bricks of class designation 75 including cement slurry & pointing in CM (1 : 3) etc. complete laid on 20 mm thick bed of : Cement Sand Mortar 1 : 6
P & F 1st qualityHeavy Duty Vitrified Polished Digital tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. Size 600mm x 600mm
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish :
20mm thick .
Distempering with dry distemper of approved brand and shade (two or more coats) and of required shade on new work, over and including, priming coat of whiting to give an even shade including all scaffolding.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade :
Two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' : 30mm tick- commercial Veneer Both side
Providing and fixing in cement sand mortar 1 : 4 single paitam (rebated) stone doors windows and ventilator frames of approved quarry : Size 100 x 75mm.
Providing and fixing factory made P.V.C. door frame of the size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm PVC foam sheet mitred at two corners and jointed with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame shall be fixed to the wall using 65/100 mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4 nos of screw to be provided for each vertical member and minimum 2 nos for horizontal member etc. complete as per manufactures specification and direction of Engineer in Charge.
30mm thick factory made solid both side Pre laminated panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles and 15x15mm top & bottom rails. M.S .frame shall have a coat of steel primers of approved make and manufacture M.S. frame covered with 5mm thick heat moulded PVC ‘C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming stiles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75 mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2) thick, 20mm
wide cross PVC sheet shall be provided as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with 7mm (5mm +2mm) thick x 15mm wide PVC sheet bending on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacture’s specification & drawing.(For W.C.and bathroom door shutter).
Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges :
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter-53, 54 & 56 for additional technical parameters of product / work refer Annexure 'A' attached with this BSR
(A) Short point (up to 3.0 mtr.)
(C) Long point (up to 10 mtr.)
Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter-53, 54 & 56. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
On Board
Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works with Galvanized box of 1.2 mm thick with earth terminal with suitable size phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter-56 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
(A) 2x1.5 sq.mm
(B) 2x2.5 Sqmm +1x1.5sqmm
(C) 2x4.0 sqmm+1x2.5 sqmm
Supply & Laying following size' B ' class , G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. All as per pre approved by Engineer in-charge. (Earth Excavation will be Paid Extra)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annex ure "A" attached with this BSR. 32mm dia
Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in-charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened, color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Compli
ant. All as per pre approved by Engineer in-charge.
LED Street Light fixture 30 Watt
Supply & drawing Wiring for sub mains ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 6.0 Sq.mm
Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification .
75mm thick.
Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :
P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
P & F 3.0 mm thick Poly propelene plastic polished concealed fan box, squre of size (106x106) mm dia, depth 50 mm , 10 mm dia rod of MS with chrome plated with 55 mm length extended on each side . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR
Half brick masonry in foundation & plinth using bricks of designation 75
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR MCB 6 A to 32 A rating
S&F following sizes of ISI marked ( IS:14927 P - II ) virgin material UPVC trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 25mmx12mm
Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :
Windows side hung /Ventilators top or centre hung (openable)
S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 25mm
Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR. 300 mm sweep(900/1400 RPM)
Providing & Fixing of ISO certified company made TP&N 415 V AC-23A front handle operated switch disconnector fuse unit, cubical type, with metallic enclosure, as per PWD specification for electrical Works conforming to IS/lEC 60947-3 : 1999 with HBC fuses including making connections with lugs, testing etc as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR 100/125 A rating
SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting.
Brick on edge flooring with bricks of class designation 75 including cement slurry & pointing in CM (1 : 3) etc. complete laid on 20 mm thick bed of : Cement Sand Mortar 1 : 6
Providing & Fixing of ISO certified company made bus bar chamber housed in sheet metal box as per PWD specification for electrical Works Confirming to IEC-60439/IS-8623 & IEC-60529/IS-2147 made out from 1.6 mm thick powder coated CRCA sheet,degree of protection IP-31, front openable bus bar made out of aluminium or wrought aluminium alloy suitable for 100 amp. Capacity , bus bar fixed on porcelain/DMC insulators at approved spacing including making connections etc. as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR. 450 mm long , 4 strip
Supplying and fixing rolling shutters of approved make, made of 80 x 1.25mm. M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 25.3cm. long wire springs grade No. 2 and M.S. top cover 1.25mm thick for rolling shutters as per design. (Clear openable area to be measured for payment).
Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :
Providing and fixing 50mm thick cement concrete flooring with Metallic concrete hardener topping, under layer of 38mm thick cement concrete 1:2:4 (1-cement : 2-coarse sand : 4-graded stone aggregate 20mm thick nominal size) and top layer of 12mm thick metallic concrete hardener consisting of mix 1:2 (1 cement : 2 stone aggregate, 6mm nominal size) by volume & mixed with metallic hardening compound of approved quality @ 2Kg./Sqm including cement slurry, rounding off edges etc. but excluding the cost of nosing of step etc. complete.
Cement plaster in skirting and/dado 18 mm thick with cement mortar 1:3 (1 cement : 3 course sand) finished with a floating coat of neat cement including rounding of junctions with floor .
Colour washing of all shades to give an even shade including all scaffolding :
New work (two or more coats) with a base coat of white washing with lime.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including Prepration of base and all scaffolding :
New work (two or more coats) over and including scrapping and priming coat with cement primer.
Wiring of light point/ fan point/ exhaust fan point/ call bell point w
ith 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & it's accessories, round tiles,18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & false ceiling point, 6 A switch, 3.0 mm thick ISI marked phenolic laminated sheet, pvc bushes, check nuts, zinc plated / brass screws, cup washers, making connections, testing etc. as required.
Medium point (up to 6 mtr.)
S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 40 mm
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required.
2 x 6.0 sq. mm. + 1 x 2.5 sq. mm.
Providing & Fixing of Wiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 10-12 Module
Providing & Fixing of ISO certified company made TP&N 415 V AC-23A front handle operated switch disconnector fuse unit, cubical type, with metallic enclosure, as per PWD specification for electrical Works conforming to IS/lEC 60947-3 : 1999 with HBC fuses including making connections with lugs, testing etc as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR 63 A rating
Supply and fixing of 1.6 mm thick MS 11 kV Danger plates as per IS :2551-1982 & specification of Discom on the existing poles complete in all respectas per PWD / DISCOM specification. All as per pre-approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR
P & F ISI marked (IS:3854) 6 amp. flush type non modular switch with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Providing & Fixing of 6 amp. Combined flush type non modular socket and switch set as per PWD specification for electrical Works,made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR Recessed Mounting 18/20W
P & F of IP65 IK10 rated LED bulk head type light fixture made from CRCA sheet steel housing suitable for mounting LED tube system (integral driver), Power consumption of 10-15W , 500-600 lumens system lumen efficiency 70 lm/ watt output suitable for1x100 W GLS/9W CFL bulk head fixtures, life time of 50000 burning hours with 70% initial lumen maintained. CCT 3000° K,4000° K and 6000° K. Fixture shall be incompliance with CE & KEMA standards. LED BULK head luminaire 9/10 W
Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods watering, rolling each layer with 1/2 tonne roller, or stone or steel rammers and rolling every 3rd and top- most layer with power roller of minimum 8-10 tonne capacity and dressing up in embankment for roads, flood banks marginal banks and guide banks or filling up ground depressions, lead up to 50 Mtr. and lift up to 1.5 Mtr.: All kinds of soil
upto 1.5 mtrs
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing & fabricating steel reinforcement for R.C.C. work including cutting, bending, palcing in position and binding complete including cost of binding wire in foundations, Raft footing step Beams base of column etc. upto plinth level. Hot rolles deformed (IS:1139) cold twisted (IS:1786) bars.
Cleaning grass and removal of rubbish up to a distance of 50 mtr. out side the periphey of the area cleared
Excavation work by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains not exceeding 1.5 mtr. In width or 10 cum of plan including dressing of siees and ramming of bottoms , lfit up to 1.5 mtr. Including taking out the excavated soil surplus excavated soil as directed with in a lead of 50 mtr. including stacking of useful material if available ordinary rock
Providing and laying in position cement concrete including curing compaction etc . Complete in specified grade excluding the cost of centering and shuttering. All work up to plinth level using crusher broken aggregate All work up to plinth level 1:4:8 (1 cement :4 coarse sand : 8 graded stone aggregated 40mm nominal size)
Random rubble stone masonry for foundation and plinth in cement sand mortar above 30 cm thick wall in: cement sand mortar 1:6 (1 cement : 6 sand)
Honey comb brick work half brick thick wi
th bricks of class designation 75 up to third storey in. Cement mortar 1:6 ( 1 cement : 6 coarse sand )
Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand)
Providing and fabricating reinforcement for RCC work including straightening, cutting, bending, placing in position in binding (including cost of binding wire ) all complete up to floor three level Cold twisted deformed bars (IS:1786)
Supplying and fixing stone lintels/bed plates of approved quarry rough dressed in cement mortar 1:4 (A) up to 15 cm thick
Supplying and fixing in walls machine cut and polished stone shelves, tands, in 1:3 with machine cut edges
Kota stone minimum 30mm thick.
Grading roof water proofing treatment with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) with water proof compound as per manufature specification
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
Providing & fixing precast cement concrete coping 1 : 2 : 4 mix 50mm thick complete as per specification :
Structural steel work riveted or bolted in built up sections, trusses and framed work, including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr height In flates, tees, angles & Channals
Providing and fixing in position collapsible steel shutters with vertical M.S. , Channels 20x10x2mm and bracket with flat iron diagonals 20x5mm, size with top and bottom rail of T-iron 40x40x6mm . with top flat of 50 x 10 mm and bottom flat of 40 x 6 with 40mm dia steel pulleys/ ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer ( To be measured and paid as per outer dimension).
Supply and fixing door, window, chowkhats and other frame including antitermite treatment MS flat old faste of size 250x40x3mm mixed with MS bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade (Klin seesoned and chemically treated Hollock wood Grade-1
Providing and fixing external grade board solid core flush door shutter ISI 2202-67 marked using phenol formal dehyderesin in glue both sides with approved steel fitting complete as per annexure A 30 mm thick
B) Decorative teak veneer both side
Add extra for RR stone masonary with hard stone in square or Rectangular pillars Up to 45cm length and all sides are free
Providing and fixing vertical blinds, made out of non woven polyster fabric 85 to 90 mm wide of approved shade & design with power coated aluminium channel minimum 1"x1" system including cording set etc. complete as per specification & directon of engineer in charge
Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately). Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/neoprene gasket etc. complete as per the architecyutal drawing and the direction of engineer-in-charge (cowst of aluminum snap beading shall be paid in basic item) with glass panes of 4.0 mm thick (weight not less than 10 kg /sqm) as per IS 2835
Providing and fixing expanded grill made of anodised aluminium as per design and drawing having members section of 7.5 mm x 6.0 mm and opening of size 102 mm x 99 mm to aluminum window/vent with required screws. Y and H aluminum sec ( as per drawing) at the ends and middle joints respectively complete in all respect as per direction of Engineer-in-charge. Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer)
Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete.
P&F bright finished mortic lock of approved made Godrej or equilent with pair of CP handles for doors with necessary screws etc. complete (Best make of approved quality) as per direction of Engineer in charge
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. With brass cover plate
Random rubble stone kharanja under floor
Plaster on new surface on wall in cement sand mortar 1:6 including raking of joints etc. complete fine finbished
(A) 20mm thick
(B) 12mm thick
6mm thick cement plaster on ceiling of mix 1:3( 1 cement : 3 fine sand)
Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete
Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to code IS : 15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).
Providing and fixing Ist quality MAT finished ceremic tiles size 300 x 300 mm confirming to IS: 13755 & IS: 15622 colour such as white, grey, Ivory, fume red brown in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry including nicely finished joints using water proof joint filler powder and finishing with flush pointing in white cement mixed with pigment to match the shade of tile complete (including the cost of cement mortar bed 1:4).
Applying priming coat with ready mix pink oir gray primer of approved brand and manufacture on wlld work hard and soft wood
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work
Distempering with oil bound washable distemper of approved brand
and manufacture to give an even shade including all scaffolding : New work(Two or more coats) over and incluiding scrapping and priming coat with cement primer
Finishing wall with water proffing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding New work (two or more coat applied @ 3.84 kg/10 sqm)
Making of drip course(Tapka) in cement sand mortar 1:6 width up to 40mm and 10mm thick as per approved design
Earth work in excavation /by mechanical means(hydraulic excavator)/manual means over areas (exceeding 30 cm in depth 1.5 mtr. In width as well as 10 sum on plan) including disposal of excavated earth lead up to 50 mtr. And lift up to 1.5 mtr. Disposed earth to be levelled and neatly dressed :ordinary rock
Finishing wall with water proffing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding New work (two or more coat applied @ 3.84 kg/10 sqm)
Making of drip course(Tapka) in cement sand mortar 1:6 width up to 40mm and 10mm thick as per approved design
P&F curtain rods of 1.25mm thick chromim platged brass plate, with two chromim plated brass brackets fixed with C.P. brass screws and wooden plugs etc. whereover necessary complete 20mm
P&F indian type white glazed vitreous china ist quality WC orissa pan (IS 2556 Mark) with 100mm vitreous china P or S trap including cutting and making good the wall and floor size 580x440 mm
P&F WVC wash basin (Ist quality IS:2556 Mark) of approved make with C.I.Brackets duly painted 1 No. 15mm CP Pillar cock (IS 8934 Mark) and 32mm CP brass waste coupling of approved make, 25mm GI waste pipe complete including cutting and making good the wall size 580mmx450mm
P&F Towel Rall or Ring of approved quality/make CP brass Town pail with brackets 600x20mm
P&F PVC storage Tank (IS :12701 marked including the BIS license No.) of approved make with cover 25mm dia 1 M long GI over flow pipe and 25 cm. long wash cut pipe with plug & socket, including making connection etc. complete of approved design
(A) 1000 Litre capacity
(B) 500 Litre capacity
P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. Size 600 x 450 mm x 4 mm thick
P&F GI Pipe (internal work) with GI fitting (IS 1239 Mark) and MS clamps including cutting and making good the walls and floors Exposed on walls Size 600 x 450 mm x 4 mm thick
(A) 15mm dia nominal bore 'B' Class
(B) 25mm dia nominal bore 'B' Class
P&F GI pipe (External works) with GI fitting (IS 1239 mark) including trenching & refilling earth etc.
Making connection of GI distribution branch with GI main including all fitting up to 25mm dia
P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:
(A) CP Brass Bib cock 15mm nominal bore
(B) CP Brass Bib cock 15mm nominal bore long body 15mm nominal bore weight not less than 690 gram
P&F stop cock (IS 8931 mark) superior quality of approved make Brass 400 gram 15mm nominal bore
P&F Ball cock (IS 1703 Mark) with Rod and PVC Ball complete Brass wt. Not less than 300 gm,15mm.
P&F full way valve (IS 778 Mark) or wheel valve of approved make
(A) Gun metal 15mm nominal bore
(B) Gun metal 25mm nominal bore
P&F sand cast floor Trap (Nahni) of (IS 1729 mark) of approved quality/make with socket down or hinged grating includinbg good the floor Size 100x100mm
P&F Flush Cock/Flush Valve (IS 9758 mark) for wC of approved quality make
(A) Brass /Gun metal Half-turn weight 1 kg of approved quality /make 25mm nominal bore
Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 m
Construction of soakage well in all type of soil with 300mm thick dry masonary top and bottom 300mm course in CM 1:6 , 80mm thick stone slab, jointing of slab in CM 1:3 Ralthal, kharanja 40mm thick M-15 grade C.C.flooring earth work complete as per approved drawing including disposal of earth with in a lead of 50 mtr. Size 240 cm dia outside and 240 cm depth
Construction of septic tank in all types of soil with 40 cm thick masonary in CM 1:6, 15 cm thick C.C.bed of 1:5:10, M-15 grade C.C.flooring & over stone slab covering, 80mm thick slab jointing of slab in CM 1:3 Ralthal, kharanja, 50mm thick stone partition wall, 20mm thick plaster in CM 1:6 finished with neat floating cement 4 Nosa. CI foot rests of approved design two Nos. 450mm dia each Ferro cement cover with frame. earth work etc. with in a lead of 50 mtr.
(A) size 230x110x150 cm (for 20 users)
Providing and laying cement concrete 1:5:10 (Stone aggregate 40mm nominal size) up to haunches of S.W.pipes including 150mm thick bed concrete (Width W= Dia of pipe in CM+30 cm) concrete width to be reduced from width W at Centre of pipe to '0' at top of pipe (Excluding cost of pipe) 100mm diameter SW pipe
(A) Inside size 300x300 mm depth up to 0.5 Cement cover with frame.
P&F rigid pvc pipe (IS 4985 mark) class II (4 kg/cm2 ) approved quality,make including jointing the pipe with solvent cement rubber ring and lubricant
(A) 110mm dia
P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: 110mm dia
(A) Door bend (Top side)
(B) Bend 87.50
(C) Vent Cowel
P&F 15mm dia connection pipe of approved quality /make
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
(A) PVc Pipe with CP Brass nuts up to length 450mm
Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges :
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter-53, 54 & 56 for additional technical parameters of product / work refer Annexure 'A' attached with this BSR
(A) Short point (up to 3.0 mtr.)
Supply and fixing GI Union ISI marked in GI Pipe line as required complete in all respect of size
(A) 15mm dia nominal bore
(B) 25mm dia nominal bore
P&F Grating of approved quality/make stainless steel sheet size 125mm dia
P&F Ist quality WVC Urinal (IS 2556 mark) with 25mm dia GI waste pipe dome waste coupling connected iron brackets or screws etc. complete Flat Back (small) size 456x355x265 mm
P&F Marble Urinal partition slab both sides polished of approved design cut form marble size 900x600mm Makrana 'Albeta' Marble having light streaks
(A) 2x1.5 sq.mm
P&F European type white glazed vitreous china Ist quality Double syphonic WC (IS 2556 mark) with P orf S trap including cutting sna making good the wall and floor
(C) 2x4.0 sqmm+1x2.5 sqmm
P & F Low level Flushing Cistern of 10 litres capacith (IS : 2556 mark), of approve make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS : 1703 mark) complete including cutting and making good the wall: PVC bend of make commander champion PVC with PVC bend as per IS 7231
P &F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor. WVC Lab sink (IS: 2556 mark) size 530 x 430 x 180mm
P&F jet spray for water closet with CP copper tube flange of approved make
Wiring of light point/fan point/exhaust fam point bell point with 1.5 sq mm nominal size SR PVC insulated unsheathed 1.1 kv grade fixible copper conductor and 1.5 sq mm nominal size FR PVC isulate copper earth conductor (IS : 694) of approved make double lock/ISI marked single lock pvc casing copping & its assessories 18 SWG MS box wikth earth terminal screwless cage connector for neutral looping in switch vboaed & falce ceiling point 6 A switch 6 A socket ,3.0 mm thick phenolic laminated sheet zinc plated/brass screws, cup washers making connection testing etc. as required
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1
kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR
Supply & Laying following size' B ' class , G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. All as per pre approved by Engineer in-charge. (Earth Excavation will be Paid Extra)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annex ure "A" attached with this BSR 32mm dia
Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR
Plate Earthing as per PWD specification for electrical Works as perIS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia.G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure "A" attached with this BSR
Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% , THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K ±355K. Driver current <1000mA shown in LM79 report. Fixture shall be IS 10322 Compliant. All as per pre approved by Engineer in-charge.
High Power LED Flood Light 30W
P & F 3.0 mm thick Poly propelene plastic polished concealed fan box, squre of size (106x106) mm dia, depth 50 mm , 10 mm dia rod of MS with chrome plated with 55 mm length extended on each side . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
ant. All as per pre approved by Engineer in-charge.
Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 12 way
S&F following sizes of ISI marked ( IS:14927 P - II ) virgin material UPVC trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 25mmx12mm
S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 25mm
Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating ,minimum width of switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in-charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR.
(A) 10A one way switch
(B) 10 A two way switch
16 Amp. 2 Module switch With Led Indicator
(D) 5 step fan regulator 100 watt 2 Module
Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high-performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
(A) 4 Module
(B) 12 Modules
Providing & Fixing of extra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe including cutting, threading, drilling, fixing quarter pin etc as reqd. All as per pre approved by Engineer in charge. For additional technical p
arameters of products/ work , refer Annexure "A" attached with this BSR
Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . (900/1400 RPM)
SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting
Providing & Fixing of ISO certified company made bus bar chamber housed in sheet metal box as per PWD specification for electrical Works Confirming to IEC-60439/IS-8623 & IEC-60529/IS-2147 made out from 1.6 mm thick powder coated CRCA sheet,degree of protection IP-31, front openable bus bar made out of aluminium or wrought aluminium alloy suitable for 100 amp. Capacity , bus bar fixed on porcelain/DMC insulators at approved spacing including making connections etc. as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR. 450 mm long , 4 strip
Providing, installation, testing and commissioning of vacuum Feed Gas Chlorinator system with all accessories and making connection with existing pipeline required including supply & installation of ejector unit, Vacuum chlorination unit, trunnion roller support, auxiliary container valve, flexible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragm Valve on injector inlet & outlet, 32 OD uPVC pipe for chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GM gate valve on pump suction & delivery, 25 NB GM 'Y' type strainer on pump suction, 25 NB GM Check valve on pump delivery, pressure gauge with Isolated valve on pump delivery and chlorine booster pump with motor of required capacity including safety equipment complete in all respect as per specification and the direction of the Engineer.
3 Kg/hr capacity
Supply of Chlorine Tonner as per specifications with rollers complete 3 in all respect as per the direction of Engineer.
Construction of Chlorine Shed (5 m x 4 m x 4 m)
Construction of Chlorinator Room (5 m x 4 m x 5.5 m)
Construction of Tonner Room (4 m x 3 m x 3.5 m)
Construction of Quenching Tank
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge. (External work). 25 mm
Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer. Apply corrosion, resistant, protection on inside and outside of casing pipe as per technical specification.
300 mm Dia 8 mm thick casing pipe.
400 mm Dia 8 mm thick casing pipe .
500 mm Dia 8 mm thick casing pipe .
700 mm Dia 10 mm thick casing pipe .
Providing, laying and jointing RCC NP4 jacking pipe (with steel pushing collar) with suitable leak proof joints (with using `12mm MDF sheets etc.) with compliance for maintaining slope as per design by trenchless method adopting Micro tunnelling method or any suitable mechanical technology below ground at all depth under running traffic condition including carrying out survey work at the job site for determining underground cable trenches like telephone, power cable, water & sanitary lines and resistivity tests for finding the soil strata using necessary equipment’s for completion of work, mobilizing of machineries and specialized crew at the job site, etc. complete in all respects, including excavation of drive pit and exit pit (upto 3 metre depth) with proper protection at the three sides, providing and casting of MS cutting edges for front shield and constructing thrust bed at designed level as directed by the Engineer, necessary de-watering and providing concrete foundations at the base of the Drive pit, crane for handling of pipes, and any other machinery, tool & tackles required, construction of temporary works as per requirement complete in all respect (all depths) with all lead and lifts, as per specification and the direction of the Engineer. Note- 1. Manual Pipe jacking is not permitted for workm
en safety reasons. 2. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers. Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable.
1600mm dia RCC pipe
Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like with pumping set of following H.P. including P.O.L./Power consumption etc. complete.
Hire charges of Pumpset of capacity 4000 litres/hour
Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift.
SITC of star rated Aluminium wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & losses as defined as per 2014 (Fourth Revision) Level-1 . including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect . The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
SITC of star rated Aluminium wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & losses as defined as per 2014 (Fourth Revision) Level-1 . including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect . The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
250 KVA with Off -LTC (+5% to - 10% @ 2.5%)
315 KVA with Off -LTC (+5% to - 10% @ 2.5%)
400 KVA with Off -LTC (+5% to - 10% @ 2.5%)
Supply, installation, testing & Commissioning of Copper wound distribution Transformer of following rating and % Impedance, 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled losses as per IS 1180 part I 2014 (Fourth Revision) Level-1, with boltless core design including standard accessories like conservator with prismatic oil level gauge , silica gel breather, Bucholz relay, pressed steel radiator fins, Radiator Valve(above 800 Kva) Suitable size HT cable box, LT cable box with Busbar connection for outgoing cables, Off -LTC (+/- 2.5%, +/- 5% to - 7.5% ), temperature rise of 40 degree C in oil / 45 degree C in winding , drain valve, Air release device, Dial type Oil & Winding Temperature gauge with alarm & trip contacts, first filling of transformer oil as per IS :335-1953 , Epoxy primer and PU based paint as Top coat, Unidirectional rollers for rating upto 800 kva & bi- directionalabove 800 Kva rollers with locking arrangement etc. as required. The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including Temperature rise test in OEM's own lab shall be witnessed by Department engineer Physically. Transformer shall be tested from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor)Following tests shall be carried out on each transformer at site by OEM enginer in presence of department authorised representative:- a) Ratio test on each tapping.b) Resistance of windings at principal and all tapings.c) Insulation resistance of the winding between HV to earth / HV to LV / LV to earth.d) Vector group test.e) Magnetic Balance test. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
Supply & Installation of D.P. Structure With AIR BREAK SWITCH having following specifications A, B, C, D, E. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . A) Double pole structure on 2 no ISMB ( I beam ) of size 150 x 75 mm, 10 mtr length using 7 no MS channel each of size 100 mm x 50 mm x 2500 mm complete in all respect with nuts, springs washers, clamps as required. B) Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3-ø, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 nos pin insulator ,GI pipe of suitable length for operation. C) 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators D) 3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv Overhead line with rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required. E) 3 no 11kv ACSR conductors mounted on pin type insularors as required. 6.GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’
SITC of HT metering cubical panel as approved By DISCOMs fabricated out of 18 SWG CRCA sheet steel in two compartment & MS angle of size 60mmX 6mm having provision for Following: (i)Provision for fixing Trivector / Import - Export Meter (To be supplied by DISCOMs) (ii)Provision for fixing of combined CT PT Set with Copper strip for Connection (To be supplied by DISCOMs), (iii)Test terminal Block, (iv) 6mm thick Bakelite sheet on al
l sides, (V) 3/6 corex 1.5 / 2.5 Sq.mm copper cable for interconnections, etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
SITC of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, outdoor duty (IP54) , Extensible / Non extensible type Ring main unit (RMU) manually operated in combination of VCB modules and Load Break switch consisting of Copper busbar in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm with manometer. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFL classification for gas tank. Vacum Interrupter of VCB should be RMU Manufacturer’s own make. Each feeder of RMU should have voltage presence indicator. . and compring of followings:- 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. - 3 Nos. Protection CT shall be of Burden 2.5VA, ratio 50/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB.- 1 No. Manometer for each tank,- 1 nos. Fault Passage indicator,-Right angle boots for all the feeder Modules All the type test certificates as per IEC from Third party NABL / CPRI / ERDA accrediated lab to be submitted. (Cost of RCC Foundation / Steel Structure to be paid Extra) All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR
Extensible 2 way RMU with 1 no. VCB & 1 No. Load Break Switch
Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 11 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift.
3 core 95.0 Sq.mm
3 core 95.0 Sq.mm
Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. including testing etc. as required of following sizes. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
3 core 50/70/95 Sq.mm
Supply, receving, storing,inspection, handling , assembilng ,installing in correct alligned position, effecting proper connections, testing and commissioning of copper wound Transformers 33/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories with off load tap changer (+5% to -10% in steps of 2.5%), winding / Top --- temperature rise of 450/400 C first fill oil, having permissible totak less values not exceeding 7.5% of the maximum total loss values for 11 KV as per energy efficiency level - 2 at basic Insulation level conferming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014.
5000 KVA (33KV / 6.6KV) AS PER IS 2026
Supply, Installation, testing and commissioning of 33 KV Double Pole structure with Air Break Switch having following specifications.a) DP : Double Pole structure made of two nos. 11 m long PCC poles (400Kg) & 7 nos. MS Channel size 100x50x6mm complete with earthing of the structure as per REC standards in all respect with nuts, springs washers, clamps as required.b) GO: Off load type gang operated three pole Horizontal type switch suitable for 33KV, 800A, 3phase central post rotating double break isolator complete with MS Hardware, copper moving & fixed contacts, assembly of 9 Nos. Post Insulators, GI pipe of suitable length for operation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set / Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Post insulators.e) LA: 3 piece non linear resistor type lightening arrestor of approved make suitable for 3 wire, 33KV oh line with rated voltage 30KV rms & nominal discharge current rating of 10 KA & complete with galvanized clamping arrangement, GI bolts, nuts, washers etc. as require
d.e)Jumpers:3 Nos. ACSR Dog Conductor mounted on pin type insulators as required. The GO shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’. Complete as per technical specifications and /or as directed by engineer.
Supply, Installation, Testing and Commissiong of indoor type floor mounted metal clad, 33 KV Incomer VCB panel up to 630 A equipped with following switchgears and accessories designed & tested as per latest standard i.e. IEC 62271-200, suitable for STC 31.5KA/3 and IAC A-FLR for 31.5kA/1sec. Make of HT Panel, Vaccum Interrupter and VCB should be of same make.
Supply, Installation, Testing and Commissiong of indoor type floor mounted metal clad, 33 KV Bus Coupler VCB panel upto 630 A equipped with following switchgears and accessories. STC 31.5KA/3 and Internal Arc test A-FLR for full short circuit current for 1 sec. duration. Make of HT Panel,Vaccum Intrrupter and VCB should be of same Make. Bus Coupler 1 No 630 Amp. VCB
Supply, Installation, Testing and Commissiong of indoor type floor mounted metal clad, 33 KV Incomer cum outgoing VCB panel up to 630 A equipped with following switchgears and accessories designed & tested as per latest standard i.e. IEC 62271-200, suitable for STC 31.5KA/3 and IAC A-FLR for 31.5kA/1sec. Make of HT Panel, Vaccum Interrupter and VCB should be of same make.
O.L.T.C. With R.T.C.C. & AVR (for 33KV)
Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 33 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
3 core 185.0 Sq.mm
3 core 120/150/185 Sq.mm
Plate Earthling as per IS:3043 with copper Earth plate of size 600mm x 600 mm x 3.0mm by embodying 3 to 4 mtr. Below the ground level with 25 mm dia. G.I. ‘B’ class watering Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
Pipe Ear thing as per IS: 3043 with perforated 3.0 Mtr. Long, 40 mm dia. ‘B’ class G.I. Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300 mm and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance as required.
S & Laying following size ‘B’ Class G.I. Pipe confirming to IS: 1239 P-1 (1990) with accessories for laying earth conductor/ strip/
cable in ground/ surface/ recess as required.
50 mm dia.
Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
50mm x 6mm copper strip
25mm x 6mm G.I. ( Hot Dipped ) Strip
32mm x6mm G.I. ( Hot Dipped ) Strip
50mm x 6mm G.I. ( Hot Dipped ) Strip
Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
100mm x 50mm x 1.6mm
150mm x 50mm x 1.6mm
300mm x 50mm x 1.6mm
Supplying and drawing PVC insulated & sheathed solid/ stranded copper conductor multi core control cable ISI marked (IS:1554) of 1.1 kV grade of approved make as per chapter E11,in existing surface or recessed conduit/ casing capping including making connections etc. as required.
4 core, 1.5 sq. mm. armoured
8 core, 1.5 sq. mm. armoured
8 core, 2.5 sq. mm. armoured
19 core, 2.5 sq. mm. armoured
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
400 SQMM, 3.5 CORE
300 SQMM, 3.5 CORE
120 SQMM, 3.5 CORE
240 SQMM, 3 CORE
185 SQMM, 3 CORE
120 SQMM, 3 CORE
95 SQMM, 3 CORE
70 SQMM, 3 CORE
50 SQMM, 3 CORE
35 SQMM, 3 CORE
25 SQMM, 3 CORE
16 SQMM, 3 CORE
16 SQMM, 3 CORE
10 SQMM, 3 CORE
4.0 SQMM, 3 CORE
SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d, (e), (f), (g), (h) as below:- (a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. [c) nterconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. (f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra ) (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. (h) only outer surface area on all sides shall be
measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . busbar and Switchgear is to be Paid Extra ) (d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee
Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Electrolytic grade Aluminium bus bar 6010 grade
Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Three phase with universal Auxiliary supply + AMP + HZ + PF + KW + KVA + KVAR + KVARH + KWH + DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485
Three phase AMP+HZ+PF+KW+KVA+KVAR+T.ENERGY+THD-I, THD-V & RUN HRS
Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in-charge.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA
C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA
C T Class 1, Ratio 1600/5 to 3000/5, Burden 15 VA
Providing & Fixing of Cam operated rotary (Auto/manual) switches on existing panel with 2 way and off position using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Red/yellow/Blue
Red/Gree/ white Colour
Red/Green
Providing & Fixing of flush head push button actuators IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, including connection etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR
Non luminous type
Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
11 KV, Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage 45 KV AC (rms)
33 KV, class C 3 mm thick with proof voltage 36 KV AC (rms) for 3 min. and Break Down Voltage 65 KV AC (rms)
SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) mad
e of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
250 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
400 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
630 Amp , 50 kA, adjustable O/L & adjustable S/C setting,
Extended Rotary Handle
Mechanical Interlocking kit
Auxiliary + Trip alarm contact
Spreaders for 250A, 4 Pole MCCB
Spreaders for 400A, 4 Pole MCCB
Spreaders for 630A, 4 Pole MCCB
SITC of Draw out type 3/4 pole door interlock Air Circuit Breaker (ACB) as conforming to IS/IEC 60947 P - 2 :2003 in existing LT panel suitable for LT installation 440 V, 50 Hz and having adjustable over load short-circuit, Instantaneous , earth fault (LSIG) with separate LED indication for each type of fault shall confirm to EMI/ EMC test , LCD/LED display, last 10 trip history, provision of ZSI, Communication, Power metering module, Thermal memory , trip free mechanisum , suitable for ambient 50 degree and utilization catagary B. In built electrical & mechanical anti pumping feature , 100% rated neutral . ACB shall have separate indication for service, test, isolation & maintenance position, Breaking capacity Icu = Ics = Icw ( 1 sec ) , U imp - 12 KV, break time not more then 25 ms. Provision for electrical & mechanical interlock between ACBs, Min.electrical operation 10000 upto 2000 A rating and 5,000 for 2500 A to 4000 A. including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
2500 A Rating ,50 kA
1600 A Rating ,50 kA
Supply and fixing of following accessories for Air circuit breaker (ACB) compatible with MAin ACB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Shunt Trip Release
Under voltage Release
Microswitch for Indication
Operation Counter
Door Interlock
Auxiliary Contact 4 NO + 4 NC
Breaker Control Switch (TNC)
Providing & Fixing of IP54 microprocessor based 3 CT’s for all 3 phase sensing compensation power factor correction relay Size 139mm x 139 mm, Operating Voltage 415/440 V , IEC / EN 61000-6-(2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, RMS Value, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and 3 no. Class- 0.5 Cast Resin CT ( refer CT specs in this chapter )for sensing the relay including making coonection with 1.5 Sq.mm copper wire etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
6 to 8 stage
12 to 14 stage
Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs (temp class - 25 D) in 440 V/480 V Capacitor and for 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D) including making connections, testing etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Heavy duty Three phase 440 V, 50 Hz cylindrical type capacitor (Bank)
Providing & Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per PWD specification for electrical Works, IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
up to 6 KVAR
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load
and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
Triple pole MCB (With B/C curve trippingCharacteristics), 6 A to 32 A rating
50/63 A rating
125A rating
Four pole MCB (With B/C curve tripping Characteristics), 6 A to 32 A rating
Double pole MCB(With B/C curve tripping Characteristics) , 6 A to 32 A rating
SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus.
SITC of Local Push Button station fabricated with 16 SWG CRCA sheet, painted with polyster Powder coated finish after chemical treatment with Folliwng items and accessories:- i Shrouded Type push button with 2 NO Contacts element for Start/forward-reverse. ii Lockable Mushroom head type push buuton with 2 NC Contact element. iii 2.5 Sqmm clipon type terminals as requried with 20% spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried.
Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
7 Mtr., Poles with Octagonal Cross Section
Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Single arm overhang
Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . A) Excavation of Pit for Foundation Size upto required depth from Ground level B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete. C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete. E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and Pedestal F) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations. G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days. H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face.
Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr.
Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift.
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >
70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
LED Street Light fixture with Minimum lumen output 8700 lm
Providing & Fixing of IP - 65 protected impact resistant polycarbonate / Polysterene enclosures with knock out for cable entry/out including fixing with nut, bolt, fatner etc as required complete in all respect of following sizes.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
32 mm Dia.
Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
High Power LED Flood Light Minimum lumen output 10000 lm
Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metr depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of OH tank and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer.
Heavy Duty AL & CU Lugs, Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Washers, Electrical Taps, HT Tap, Danger Plates, 4.5 Kg. CO2 type portable fire extinguisher for Panel Room , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per site requirements.
33KV Switchyard Civil work for Transformers Foundations, DP Structure, Chain Link Fencying 1500mm Height, MS Gate , 40mm Gravels, boundary wall, Earthing Chambers, HT/LT cable Trench,covers ect.
11KV Switchyard Civil work for Transformers Foundations, DP Structure, Chain Link Fencying 1500mm Height, MS Gate , 40mm Gravels, boundary wall, Earthing Chambers, HT/LT cable Trench,covers ect.
Supply, Installation, Testing and Commissiong of indoor type floor mounted metal clad, 6.6 KV Bus Coupler VCB panel equipped with following switchgears and accessories. Bus Coupler upto630 Amp. VCB
ering and class 5P10 for protection 5. Multifunction Meter . Outgoing upto 630 A VCB for HT MOTORS
6.6 KV HT FMCA Digital Soft Starter Panel with reactor for min 500 KW HT VT Motor , --Inddor Type, Metal enclosed compartmentalized, Short Circuit withstand & duration (Sec.) - 9kA for 1Sec, Rated 7.2 KV ±10%, 50Hz ±5%, 3Ph, IP 4X, Control & Protection Sypply - 110VDC, 10KV for 1min power frequency, 2 Pole Vacuum Contactor 400A, Bus Bar - Copper, FMCA Coils type - Air Core as per IEC 60076-6, Insulation - Class F, Temp. rise limited to class B. Coil material - Copper conductor is wound on Fiberglass bobbin, No of Tappings - 5 nos., Single Power cable Based.
6.6 KV/ min 350 KVAR HT APFC Panel for 500KW HT Motor , - 7.2KV ±10%, 50Hz ±5%, 3Ph, IP 4X, Control & Protection Sypply - 110VDC, Connection - Line side ( Shunt Connection) , Air Cooled, Bus Bar 400A Copper, Metal enclosed compartmentalized.
Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 6.6 K.V.(UE) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
3 core 185.0 Sq.mm
3 core 150.0 Sq.mm
3 core 120/150/185 Sq.mm
6.6 KV NGR Control Panel, 3.81 Ohms with 100 A, 10 Sec Capacity with supporting Structure for installation.Hence NGR of 3.81 Ohms is required with capacity of 1000 Amp 10 sec.Complete as per technical specifications and as directed by Engineer in charge.
SITC of HT 33KV, 3Phase, 50Hz, totally enclosed metal clad SF6 switchgear having rupturing capacity upto 630 Amps, Outdoor Non Extensible Fixed Type (IP54), RMU (Ring main unit) comprising of manually operated Load Break Switch and manual charging fixed-type Vacuum Circuit Breaker as per requirement, inside robotically welded stainless steel grade 304 (Non Ferrite Non Magnetic Grade) tank having of minimum thickness 2 mm with IP67 Degree of Protection and enhanced BIL of 170kVp internally to manage voltage surges. RMU should be provided with internal bus bars, as well as earthing bus bars of electrolytic grade copper, padlock provisions & complete with all accessories. The RMU shall be type tested for Internal arc test of AFLR 25kA/1 sec for tank and cable chamber as per IEC62271-200. RMU shall have on-site-repair ability features such as site replaceable bushing/ coupling/ mechanism and gas refilling at site. The earthing bus bar shall be provided inside each cable compartment for solid earthing of cable sheilds. The outer hinged main door should cover entire front of switchgear including cable doors for providing better ingress protection. The unit shall include the following with all necessary standard fittings as required at site. Load Break Switch module consisting of following accessories : 33kV, 630 Amp Load Break Switch module and integrated earthing switch, both with full making capacity. Short Circuit withstand capacity - 25kA/3-sec, Making Capacity – 62.5 kAp, Auxiliary contacts - 1NO + 1NC Fault Pass Indicator - 1 Nos, touch-proof screen separable termination kit (push on type) VCB Breaker module consisting of following accessories : 33 kV, 630 Amp fixed-type Vacuum Circuit Breaker module for making and breaking of fault current along with disconnector + Earth Switch of full making capacity. Short time current breaking capacity - 25KA/ 3 sec, Making Capacity – 62.5kAp, Auxiliary contacts - 1NO + 1NC VCB operating sequence must be O-0.3Sec-CO-3Min-CO and mechanical endurance confirms for minimum 10000 operations. touch-proof screen separable termination kit (push on type) Numerical based self-powered OC+EF Protection Relay, providing Over Current (min. setting 20%), Earth-Fault (min. setting : 10%) 03 Nos 50-100/1, 2.5VA epoxy insulated, Ring Core CTs for protection (Acc. CL5P10), installed away from bushings to prevent saturation of core. (CT Ratio my change according to change in Load) All modules should have Suitable site replaceable cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/ testing/ replacement purposes.
Cable covers with self-Interlocking mechanism between doors, earth switch, disconnector & VCB Capacitive voltage indication fixed type system (i) Capacitive voltage indication fixed type VPIS 28-45 kV (ii) One No. Operating Handle for Manual Operation and one no. manometer (iii) Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturer’s directions (iv) Above switchgear shall confirm to all relevant IEC/IS Standards. (v) Vacuum interrupter should be of same make as RMU (vi) Cable bushing should be replaceable at site. (vii) Minimum 4 module should accommodate in one tank to avoid multiple coupling at site.
Non-Extensible Type 4 way RMU with 2 no. VCB & 2 No. Load Break Switch
SITC of Intelligent Manageable Ethernet Switches providing 24 x 10/100/1000 Fast Ethernet ports- and 2 dual purpose uplink (provision for Copper / Fibre Giga connectivity) with LAN based Software. The LAN based S/W supports enhanced integrated security, including Network Admission Control (NAC), advanced quality of service (QoS), availability and scalable management to enable new converged applications
Providing, installation, testing and commissioning of ONLINE UPS SYSTEM, Single Phase 230 V, 50 Hz with 2 hour backup SMF battery bank as per specification
Providing and laying Stranded/ Flexible Annealede Bare copper conductor ,XLPE/PVC insulated suitably laid up together overall polyster taped Al (inner sheated GI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steel armoured overall PVC sheathed (ST-1) overall screened Core armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009.
24 CORE, 1.0 sq. mm.
4 CORE, 1.0 sq. mm.
Providing and laying Stranded/ Flexible Annealed Bare copper conductor ,XLPE/PVC insulated suitably laid up together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wire overall PVC sheathed (ST-1) overall screened Pair armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. (2 Pair * 0.75SQMM)
Providing, Installation, Testing and Commissioning of Ultrasonic Level Transmitter : Principle : Time of Flight / Sensor MOC PP / Power Supply: 24 V DC / Output: 4- 20mA / Display: Integral display for programming and Display Reading / IP 66/ Accuracy ±1%
Providing, Installation, Testing and Commissioning of Pressure Transmitter : Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA with HART / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.44 MB
09.pdf
Tender Documents • 24.04 MB
BOQ_841451.xls
BOQ • 1.54 MB
COR12NIT09.pdf
PDF • 0.29 MB
COR11NIT09.pdf
PDF • 0.34 MB
Download all tender documents and submit your bid