Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC GORAKHPUR UTTAR PRADESH | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | L1 | Accepted-AOC The lowest tenderer | |
| 2 | L2₹18.8 L+₹2.3 L (13.8%)Rejected-Finance | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹19.7 L+₹3.2 L (19.2%)Rejected-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹21.7 L+₹5.2 L (31.2%)Rejected-Finance | L4 | Rejected-Finance Not the lowest tenderer | |
| 5 | L5₹22.8 L+₹6.2 L (37.6%)Rejected-Finance | L5 | Rejected-Finance Not the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹48,120
Closing Date
6 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
SPL REPAIR FOR AUTOMATIC POWER FACTOR CORRECTION PANELS INCLUDING CONNECTED WORKS AT FARIDKOT MIL STN
2023_MES_631956_1
CA NO CWE SGNR T-42 OF 2023-24
Open Tender
Miscellaneous Works
Item Rate
180 days
GE FARIDKOT
As per NIT
9 documents required · 9 mandatory
₹500
GE FARIDKOT
₹48,120
7 Mar 2024
9 Dec 2023
8 Jan 2024
9 Dec 2023
6 Jan 2024
23 Dec 2023
Amount
Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr in depth in soft/loose soil for laying under ground cable and getting out soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing the excavated soil to a distance n. exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M & L for sand cushioning with dry and clean locally available sand for underground cable 8cm before laying cable and 15 cm after laying cable and punned to 18 cm after laying of cable complete all as specified and directed by Engineer-in-Charge Note: Pressed thickness shall be considered for payment purpose
Supplying and laying un-reinforced precast concrete cable cover, class LV, type-1, flat, size 250 mm x 150 mm x 40mm complete all as specified and directed by Engr-in-Charge.
M&l for galvanised mild steel pipe /tubing of size 50 mm bore dia, light grade complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with mild steel clamps , bolts ,nuts and washers complete all as specified of following bore and as directed.
Supply, laying or passing in replacement through pipe, XLPE insulated armoured electric power UG cable with aluminium conductor 1100 volt grade of size 25 Sqmm 3.5 core including cable gland, terminal lugs in trenches, ducts, pipe on walls, pole complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks and pipe shall be measured and paid separately under appropriate items.
All as per item No 7.00 above but of size 50 Sqmm 3.5 core.
All as per item No 7.00 above but of size 70 Sqmm 3.5 core.
All as per item No 7.00 above but of size 95 Sqmm 3.5 core.
Supply, install, testing and commissioning in replacement weather and vermin proof LT feedar pillar box (Panel board) factory fabricated indoor type totally enclosed made out of 2.0 mm thick sheet metal enclosure of suitable size, with angle iron frame of MS angle 40 X 40 X 6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting suitable and sufficient nos circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated (15 micron) grey hammer tone with one coat of including connecting with LT armoured incoming and outgoing cables and including required sizes of cable lugs and angle iron stand with PCC work complete all as specified and directed and consisiting of following :-
(a) Aluminium bus bar of 1000 Amp current rating capacity, length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator. (b) ACB 800 Amps 4 Pole 60 KA, 415 V - 01 No. for incoming. (c) MCCB 400 Amps 4 Pole 50 KA, 415 V - 03 for outgoing. (d) MCCB 250 Amps 4 Pole 36 KA, 415 V - 02 for outgoing. (e) Digital mutifunction meter for indicating of current, voltage with necessary CTs etc - 01 No. (f) LED type indicator lamp Red/Yellow/Blue colour-01 set.
Supply, install, testing and commissioning in replacement weather and vermin proof LT feedar pillar box (Panel board) factory fabricated indoor type totally enclosed made out of 2.0 mm thick sheet metal enclosure of suitable size, with angle iron frame of MS angle 40 X 40 X 6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting suitable and sufficient nos circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated (15 micron) grey hammer tone with one coat of including connecting with LT armoured incoming and outgoing cables and including required sizes of cable lugs and angle iron stand with PCC work complete all as specified and directed and consisiting of following :-
(a) Aluminium bus bar of 1000 Amp current rating capacity, length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator. (b) ACB 800 Amps 4 Pole 60 KA, 415 V - 01 No for incoming. (c) MCCB 630 Amps 4 Pole 50 KA, 415V - 01 for outgoing. (d) MCCB 400 Amps 4 Pole 36 KA, 415 V - 02 for outgoing. (e) MCCB 250 Amps 4 Pole 36 KA, 415 V - 01 for outgoing. (f) Digital mutifunction meter for indicating of current, voltage with necessary CTs etc - 01 No. (g) LED type indicator lamp Red/Yellow/Blue colour-01 set.
Supply , installation, testing and commissioning in replacement of power factor improvement panel of capacity 200 KVAR (5 KVAR x 02 No, 15 KVAR x 01 No, 25 KVAR x 03 Nos and 50 KVAR x 02 Nos ) including suitable MCCB as incomer and TPN as outgoings with power factor controller relay 7 steps, seven segment LED Display fixed in suitable size of panel fully type test according to IEC 61439-1&2,IEC 61921 including interconnection with LT panel with appropriate size of electric cable, factory made, weather proof , dust and vermin proof (IP 65) 1100 V/660 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 14 SWG CRCA sheet welded on 40 x 40 x 3 mm angle iron frame / base of appropriate size and having four Nos angle iron legs made out of 40 x 40 x 6mm 60 cm long angle iron below frame with front door and back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:3:6 type C-1 using 20mm graded stone aggregate of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles , all as specified and directed by Engr-in-Charge and all other electric incoming and outgoing connections with PVC insulated multi stranded flexible copper cable of suitable size and PVC flexible conduit medium quality as required complete all as specified and directed.
Supply , installation, testing and commissioning in replacement of power factor improvement panel of capacity 100 KVAR (5 KVAR x 02 No, 15 KVAR x 01 No, 25 KVAR x 03 Nos ) including suitable MCCB as incomer and TPN as outgoings with power factor controller relay 7 steps, seven segment LED Display fixed in suitable size of panel fully type test according to IEC 61439-1&2,IEC 61921 including interconnection with LT panel with appropriate size of electric cable, factory made, weather proof , dust and vermin proof (IP 65) 1100 V/660 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 14 SWG CRCA sheet welded on 40 x 40 x 3 mm angle iron frame / base of appropriate size and having four Nos angle iron legs made out of 40 x 40 x 6mm 60 cm long angle iron below frame with front door and back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:3:6 type C-1 using 20mm graded stone aggregate of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles , all as specified and directed by Engr-in-Charge and all other electric incoming and outgoing connections with PVC insulated multi stranded flexible copper cable of suitable size and PVC flexible conduit medium quality as required complete all as specified and directed.
Supply , installation, testing and commissioning in replacement of power factor improvement panel of capacity 60 KVAR (2 KVAR x 01 No, 3 KVAR x 01 No, 5 KVAR x 01 No, 10 KVAR x 01 No and 20 KVAR x 02 Nos ) including suitable MCCB as incomer and TPN as outgoings with power factor controller relay 7 steps, seven segment LED Display fixed in suitable size of panel fully type test according to IEC 61439-1&2,IEC 61921 including interconnection with LT panel with appropriate size of electric cable, factory made, weather proof , dust and vermin proof (IP 65) 1100 V/660 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 14 SWG CRCA sheet welded on 40 x 40 x 3 mm angle iron frame / base of appropriate size and having four Nos angle iron legs made out of 40 x 40 x 6mm 60 cm long angle iron below frame with front door and back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:3:6 type C-1 using 20mm graded stone aggregate of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles , all as specified and directed by Engr-in-Charge and all other electric incoming and outgoing connections with PVC insulated multi stranded flexible copper cable of suitable size and PVC flexible conduit medium quality as required complete all as specified and directed.
Supply , installation, testing and commissioning in replacement of power factor improvement panel of capacity 40 KVAR (2 KVAR x 01 No, 3 KVAR x 01 No, 5 KVAR x 01 No, 10 KVAR x 01 No and 20 KVAR x 01 Nos ) including suitable MCCB as incomer and TPN as outgoings with power factor controller relay 7 steps, seven segment LED Display fixed in suitable size of panel fully type test according to IEC 61439-1&2,IEC 61921 including interconnection with LT panel with appropriate size of electric cable, factory made, weather proof , dust and vermin proof (IP 65) 1100 V/660 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 14 SWG CRCA sheet welded on 40 x 40 x 3 mm angle iron frame / base of appropriate size and having four Nos angle iron legs made out of 40 x 40 x 6mm 60 cm long angle iron below frame with front door and back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:3:6 type C-1 using 20mm graded stone aggregate of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles , all as specified and directed by Engr-in-Charge and all other electric incoming and outgoing connections with PVC insulated multi stranded flexible copper cable of suitable size and PVC flexible conduit medium quality as required complete all as specified and directed.
Supply, installation, testing and commissioning in replacement of power factor improvement panel of capacity 25 KVAR (2 KVAR x 01 No, 3 KVAR x 01 No, 5 KVAR x 02 No and 10 KVAR x 01 No ) including suitable MCCB as incomer and TPN as outgoings with power factor controller relay 7 steps, seven segment LED Display fixed in suitable size of panel fully type test according to IEC 61439-1&2,IEC 61921 including interconnection with LT panel with appropriate size of electric cable, factory made, weather proof , dust and vermin proof (IP 65) 1100 V/660 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 14 SWG CRCA sheet welded on 40 x 40 x 3 mm angle iron frame / base of appropriate size and having four Nos angle iron legs made out of 40 x 40 x 6mm 60 cm long angle iron below frame with front door and back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:3:6 type C-1 using 20mm graded stone aggregate of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles , all as specified and directed by Engr-in-Charge and all other electric incoming and outgoing connections with PVC insulated multi stranded flexible copper cable of suitable size and PVC flexible conduit medium quality as required complete all as specified and directed.
Material and labour Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 32 X 6 mm (upto the body of equipment) by means of GI bolts/nuts/washers, protected by 40 mm bore GI medium grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI light grade pipe for watering and including funnel, wire mesh,RCC cover & frame, PCC (1:3:6) type C2 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No 3 of MES schedule Part – I complete and directed by Engr-in-Charge.
Vinod Kumar Bajaj
Singla Electricals
m/s G.S. Enterprises
NEW AMRITSAR CONSTRUCTION COMPANY
Aziz Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .