Tender Value
₹4.6 L
EMD Value
₹9,200
Closing Date
11 Aug 2021, 12:00 pmClosed
EEE-II Shah(S)
OFFICE OF THE Ex ENGINEER (ELECT)-II 2 nd Floor Technical Laboratory Near NH-24 Ghazipur Delhi
Repair Renovation of E.I and fans at M and CW Center A block vivek vihar phase-II in ward no.30E under shd. South zone
2021_EDMC_83824_1
EE (Elect)-II//2021-22/8.1
Open Tender
Electrical Works
Item Rate
90 days
works
Please refer to tender documents
5 documents required · 5 mandatory
₹500
₹9,200
Yes
9 Jul 2024
3 Aug 2021
12 Aug 2021
3 Aug 2021
11 Aug 2021
3 Aug 2021
Amount
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group-C
supply and fixing of following sizes medium class pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required a)25 mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3x2.5 sq.mm
3x4 sq.mm
3x6 sq.mm
Supplying and fixing following piano type switch/ socket on theexisting switch box/ cover including connections etc. as required. 5/6 amps switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
supply of XLPE PVC Sheathed Al. Conductor Armoured Cable for working voltage upto 1.1kV confirming to IS-7098(Part-I) of following sizes: 2 x 10 sq.mm
4 x 25 sq.mm
Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal)size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as require
supply and fixing of Metal box 180mm x 100 mmx 60 mm deep (nominal size) on surface / recess with suitable size of phenolic laminated sheet cover infront including providing and fixing 6 pin 5/6 &15/16A socket outlet and 15/16A piano type switch ,connection painting etc as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker single pole suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 Amp rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing Single pole blanking plate in the existing MCB DB complete etc. as required
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel,dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way 8 way (4 + 24), Double door
Providing and fixing following Rating and breaking capacity MCCB WithThermomagnatic release and Terminal Spreader in existing cubical panel board including drillingholes in cubical panel ,making connection etc as required.disconnector fuse switch unit inside the existing panel board with ISI Marked HRC fuses including drilling holes in cubile panel making connection etc as reqd. 100A
Supply and fixing of 4.5 Kg DCP with COCO2 fire extinguisher (wall mounting type) gas cartridge fire extinguisher (conforming to IS: 2171 with cylinder fully charged)
Supplying and installing at approved location approved make 4 nos. fire buckets of 24 gauge galvanized steel , painted white inside as red outside and back on the bottom, inscribed with letter "FIRE" in black and gold including stand fabricated out of sheet metal (16 gauge) shade, platform and associated civil works, painting etc. as approved by the fire authority.
Supplying & fixing of light class GI pipe of 50 mm dia (nominal) 3 m length along the pole for protection of U/G cable as reqd.
supply and erection of 3.5 meter length (above the ground level) M.S Decorative street light pole having two section of M.S Pipe. The inner dia, outlet dia and length of bottom section should be 132 mm x139 mmx1000 mm (NS) respectively and of upper section should be 69 mm x76 mmx2490 mm. The pole should have a circular base plate of dia268 mm and thickness 9.75 mm and also an inbuilt junction box having opening and closing doors that is one no 10 amp. MCB and neutral link at the bottom section. the pole should be PU painted that is 4 no 10 mm J Type foundation bolt and 0.25 cum cement concrete(1:3:6) foundation etc as red.
Supply instaltaion testing and commssioning of 25 W LED IP 65 post top fitting made of dia cast Al spigot spun AL powered coated top cover and clear acrylic deffuser with high voltage protection low power LED's connected in series and parallel combination with better heat sink arrangement input voltage 160-260 volt AC, 50 Hz Ac supply power factor .0.95. luminious efficiency .100 lumines/ watt, CCT 5700 degree K +/- 300 degree K, Surge protection not less than 10KV complete etc. as required.
SITC of 60W LED Flood Light luminiare fitted with lense, made of pressure die cast aluminium housing & toughned glass cover complete with the following specification as reqd.. (b) Total system wattage =60 watt +/- 5% c) Luminaire Efficacy>=100 Lm/w d) Power Factor>=0.95s f) Protection IP-66
S/I/T/C of LED Tube type luminaire 20 Watt rating complete with Extruded Aluminium Batten prewired with high efficient LEDs with the following: a) Total system wattage 20 ±5% Watt b)Luminaries efficacy ≥ 95 Lumens/ watt c) Pf ≥ 0.95
supply and fixing of 400mm single phase swing wall fan as reqd.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. D) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A
Supply of 1.5 Ton Window Air Conditioner ( 5 star rating) ( copper conduncer) along with cu cable remote suitable for,230 V +- 10 % electric supply as reqd.
P&F of 4 KVA Voltage Stabilizer with TDR and Triple step, High & Low voltage Cutt off device complete as reqd.
Standard Installation charges for Window AC including labour and petty items reqd. for the installation of the same as complete as reqd.
Providing and fixing of invertor of 2000 VA 2 Nos 150 AH Batteries with trolley suitable for keeping 2 Nos Battery and 1 no inverter i/c wiring & connections etc as reqd.
SITC of single phase/three phase monoblock pump set complete with allaccessories workable on 240/415V ,50HZ ac supply 1hp single phase pump set head from 12-30 meter suction and delivery 25*25mm
P&F of water/weather proof junction/pole box made out of 16 SWG MS sheet steel of size200x150x100mmdeep dully painted complete with one No SP-MCB(6to32Amp) and neutral link & locking arrangement etc as reqd.
Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conformingto IS: 12818, including required hire and labour charges, fittings & accessoriesetc. all complete, for all depths, as per direction of Engineer -in-charge. a) 100 mm nominal size dia.'
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. al lcomplete, for all depths, as per direction of Engineer-in-charge. a) 100 mm nominal size dia
Redevelopment of tubewell with suitable capacity of air compressor i/c lowering of necessary induction pipe or line i/c cost of fuel,hire charges of compressor etc. The development shall be considered complete when graval stop sinking,discharge ceased to improve nad the sand contains are not more than 10 PPM after 20 minutes of starting the pump complete as required
S/I/T/C of surface mounting CRCA housing 8 watt LED luminaire with acrylic cover diffuser with following specifications including fixing on existing wall /surface with connections as reqd. (a) Total system wattage = 8 watt +-/-5% (c) Luminous efficacy>=95 limens/watt. (D) Power factor>=0.95
Supplying and fixing 20 amps, 240 V, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
SITC of Desert cooler in metalic body of 18mm gauge ,12 inch deep capacity with fan of 18 inch size having 3 blades heavy duty motor with iron angle stand as per required size and design
SITC of wall mounting BEE 5 star rating water heater geyser of capacity 6 liter, pressure rating 60N/sq.cm and material of inner container shall be stainless still with minium length of flexible cable with 3 pin plug of 16AMP etc as required
SITC of 150 ltr water cooler with following specifications are:- a) Cooling Capacity ltrs /hr .b) Eco - Friendly ( Non CFC Refrigent) c) water tank sheet material and thickness .-Stainless Steel ( Grade AISI 3 04 ), Thickness >= 0.8 d) water tank cover and lid bottom sheet material - High Impact Polystrene (HIP) e) Conformity to IS : 1475 latest.
G D Electricals
CANTILEVER ENGINEERS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .