Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.7 LAccepted-AOC A 93 SECTOR 36 GREATER NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201308 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201308 | L1 | Accepted-AOC L1 | |
| 2 | L2₹25.6 L+₹1.8 L (7.52%)Rejected-Finance 1 OPP NAGAR NIGAM KATNI MAIN ROAD KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | L2 | Rejected-Finance Being not lowest tenderer | |
| 3 | Rejected-Technical H NO 106 D POCKET A MAYUR VIHAR PHASE II DELHI 110091 | DELHI | EAST DELHI | DELHI | 110091 | - | Rejected-Technical Not admitted due to not enlsited in requisite criteria |
| Sl No | Description | Qty | Unit | Neeraj Enterprises L2 | Deepak Electricals L1 |
|---|---|---|---|---|---|
| 1.00 | Supply and install hi wall split units indoor/outdoor complete with minimum 5 star rating and EER 3.2.of capacity 2 TR as shown complete all as per specified and as directed.
Note: 1 Making hole in wall, insulation of copper tubes, stand for outdoor unit (wall mounted/roof top type), T&P required for installation & making good the disturbed surface is deemed to be included in quoted rates. | 12 | Each | 55,010 ₹6,60,120 Lowest | 60,750 ₹7,29,000 |
| 2.00 | Supply and fixing Industrial socket sheet metal enclosure with socket plug top and MCB single pole and neutral with a two pin and earth plug and socket with one single pole MCB of 32 Amp complete all as specified and directed by Engineer-in-charge. | 12 | Each | 1,100 ₹13,200 | 900 ₹10,800 Lowest |
| 3.00 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 160 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed by Engineer-in-charge. | 12 | Each | 4,520 ₹54,240 | 3,550 ₹42,600 Lowest |
| 4.00 | M&L for Sub main wiring complete with non-metallic rigid PVC insulated fire retardant grade unsheathed 1100V grade multistranded copper conductor cable 2 run of 4 Sqmm single core confirming to IS-694 with copper conductor drawn through PVC casing capping/conduit heavy duty and accessories in walls, roof and floors along with 1 run of 4 Sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor complete including chase cutting by cutter concealed in PVC conduit all as specified and as directed by Engineer-in-Charge. | 450 | RM | 230 ₹1,03,500 | 195 ₹87,750 Lowest |
| 5.00 | M&L for earthing with electrode should be 2 No’s Copper Plate of size 90cmx60cmx5mm inter connected with 50 X 6 mm copper strip of length 1.5 mtrs and in center shall be 32 X 6 mm copper strip of 3 meter with suitable brass nut bolts and brazing for lower resistance. Alternate layers of Soil & Curec+ or equilent (03 kgs bag x2 ) ; make as per IEEE 80 2000 ,
Clause 14.5 D, Maintenance Free Earthing System to give Earthing Resistance value of ≤ 1Ω. The soil shall be mixed with backfill CURENITE or equivalent (25-kgs x 2bags). Copper Electrode’s should be solid rod and surrounded with highly conductive and non corrosive nature (pH value certified) & covered with Poly plastic Earth Pit Cover in and including construction of PCC boundry with specified colour coding around the poly plastic pit cover. Further electrodes of GI pipe atleast 30mm dia shall be interconnected in parallel fashion incase low ohmage is not achievable poly plasticc enclosure shall be provided. | 1 | Each Job | 75,020 ₹75,020 | 60,500 ₹60,500 Lowest |
| 6.00 | S&F in replacement of factory made epoxy polyster powder coated distribution board SPN 6 way fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incoming and 6 outgoings complete all as specified and confirming to IS: 8623.
Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate. | 10 | Each | 1,510 ₹15,100 | 1,250 ₹12,500 Lowest |
| 7.00 | Supply and install Flame proof air cooled,GI powder coated outer body units indoor/outdoor complete with cordless remote control unit with minimum 5 star rating and EER 3.2.of capacity 1.5 TR as shown Make:- Friz Cool Twin Compressor-single speed Type :- floor mounted Power input : 220V/50 Hz/ Single phase or equivalent as approved by GE.
Note: 1) Making hole in wall(included Lintel Beam), insulation of copper tubes, stand for outdoor unit (wall mounted/roof top type), T&P required for installation & making good the disturbed surface is deemed to be included in quoted rates. | 2 | Each | 2,15,050 ₹4,30,100 | 2,08,500 ₹4,17,000 Lowest |
| 8.00 | Supply and fixing Industrial socket sheet metal enclosure with socket plug top and MCB single pole and neutral with a two pin and earth plug and socket with one single pole MCB of 32 Amp complete all as specified and directed by Engineer-in-charge. | 2 | Each | 1,500 ₹3,000 | 900 ₹1,800 Lowest |
| 9.00 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 160 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed by Engineer-in-charge. | 2 | Each | 4,550 ₹9,100 | 3,550 ₹7,100 Lowest |
| 10.00 | Supply and fix dehumidifier continuous operating complete, Power rated consumption 660W(30 degree centigrate 80% RH)
*Airflow:-250M3/H
*Air Flow(Dry Mode): 380M3/H
*Noise Level:50DB(A)
*Moisture Removal (L/Day):35L/Day (26.7 Degree Centigrade 60% RH) 50L/Day (30 Degree C 80% RH
*Water tank Cap:-5L
*Refrigerant:-R410 | 1 | Each | 1,25,055 ₹1,25,055 | 1,22,500 ₹1,22,500 Lowest |
Tender Value
₹26.7 L
EMD Value
₹53,360
Closing Date
2 Feb 2026, 6:00 pmClosed
GE AF TUGHLAKABAD
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
IMPROVEMENT TO DAILY ISSUE LOCK-UP AT ARMOURY AND PROVN OF AIR CONDITIONER AND ASSOCIATED ITEMS AND PROVN OF EMERGENCY EYE WASH POINTS AND ALLIED WORKS AT PWs AT AF STN 7BRD AND ADDN/ALTN TO BLDG NO. P-87 AND IMPROVEMENT TO OTM ACCN NEAR BLDG NO. P88
2026_MES_748146_1
GE/TKD-70/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI
As per NIT conditions
8 documents required · 8 mandatory
₹0
₹53,360
Yes
11 Apr 2026
12 Jan 2026
4 Feb 2026
12 Jan 2026
2 Feb 2026
26 Jan 2026
Supply and install hi wall split units indoor/outdoor complete with minimum 5 star rating and EER 3.2.of capacity 2 TR as shown complete all as per specified and as directed. Note: 1 Making hole in wall, insulation of copper tubes, stand for outdoor unit (wall mounted/roof top type), T&P required for installation & making good the disturbed surface is deemed to be included in quoted rates.
Supply and fixing Industrial socket sheet metal enclosure with socket plug top and MCB single pole and neutral with a two pin and earth plug and socket with one single pole MCB of 32 Amp complete all as specified and directed by Engineer-in-charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 160 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed by Engineer-in-charge.
M&L for Sub main wiring complete with non-metallic rigid PVC insulated fire retardant grade unsheathed 1100V grade multistranded copper conductor cable 2 run of 4 Sqmm single core confirming to IS-694 with copper conductor drawn through PVC casing capping/conduit heavy duty and accessories in walls, roof and floors along with 1 run of 4 Sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor complete including chase cutting by cutter concealed in PVC conduit all as specified and as directed by Engineer-in-Charge.
M&L for earthing with electrode should be 2 No’s Copper Plate of size 90cmx60cmx5mm inter connected with 50 X 6 mm copper strip of length 1.5 mtrs and in center shall be 32 X 6 mm copper strip of 3 meter with suitable brass nut bolts and brazing for lower resistance. Alternate layers of Soil & Curec+ or equilent (03 kgs bag x2 ) ; make as per IEEE 80 2000 , Clause 14.5 D, Maintenance Free Earthing System to give Earthing Resistance value of ≤ 1Ω. The soil shall be mixed with backfill CURENITE or equivalent (25-kgs x 2bags). Copper Electrode’s should be solid rod and surrounded with highly conductive and non corrosive nature (pH value certified) & covered with Poly plastic Earth Pit Cover in and including construction of PCC boundry with specified colour coding around the poly plastic pit cover. Further electrodes of GI pipe atleast 30mm dia shall be interconnected in parallel fashion incase low ohmage is not achievable poly plasticc enclosure shall be provided.
S&F in replacement of factory made epoxy polyster powder coated distribution board SPN 6 way fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incoming and 6 outgoings complete all as specified and confirming to IS: 8623. Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate.
Supply and install Flame proof air cooled,GI powder coated outer body units indoor/outdoor complete with cordless remote control unit with minimum 5 star rating and EER 3.2.of capacity 1.5 TR as shown Make:- Friz Cool Twin Compressor-single speed Type :- floor mounted Power input : 220V/50 Hz/ Single phase or equivalent as approved by GE. Note: 1) Making hole in wall(included Lintel Beam), insulation of copper tubes, stand for outdoor unit (wall mounted/roof top type), T&P required for installation & making good the disturbed surface is deemed to be included in quoted rates.
Supply and fixing Industrial socket sheet metal enclosure with socket plug top and MCB single pole and neutral with a two pin and earth plug and socket with one single pole MCB of 32 Amp complete all as specified and directed by Engineer-in-charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 160 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed by Engineer-in-charge.
Supply and fix dehumidifier continuous operating complete, Power rated consumption 660W(30 degree centigrate 80% RH) *Airflow:-250M3/H *Air Flow(Dry Mode): 380M3/H *Noise Level:50DB(A) *Moisture Removal (L/Day):35L/Day (26.7 Degree Centigrade 60% RH) 50L/Day (30 Degree C 80% RH *Water tank Cap:-5L *Refrigerant:-R410
S&F in repalcement of MCB SP 63 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed by Engineer -in -charge.
Supply and fixing in replacement of Automatic transfer switch of capacity 200 Amp 4 pole,AC-31 A,50 HZ,415 V automatic/ manual with inbuilt time delay complete all as specified and as directed by Engr-in-charge.
S&F stop valve cast copper alloy chromium plated high pressure, fancy type screwed on both ends with iron pipe or unions, 15 mm bore fancy type all as specified and directed.
S/F waste fittings brass Chromium Plated for glazed ware sinks basins etc with long screwed shanks and fly nuts flange end embedded in red lead cement and other end fixed of 32mm size all as specified and directed.
S&F of 32 mm bore of pipe low density (LDPE) of pressure rating 6 kg/ sqcm fixed to wall or floor etc including fittings complete all as specified and as directed.
M&L for PVC (SWR) floor trap of 75mm dia, plain with grating including jointing with solvent cement all as specified and directed.
S&F 75 mm bore PVC (SWR) rain water pipes of single socketed in any length with rubber ring joints, jointed with solvent laid in trenches or in floors with matching PVC SWR rings including cutting holes and making good the disturbed portion with PCC 1:2:4, type B0 complete all as specified and directed by Engr-in-Charge.
Supply and fixing framed work such as grills, gratings, tank cover, drain covers made of angle,for monkey proofing, channel, bars and sheets etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and as directed.
Material and labour for preparation of new steel surfaces of any description over 10 cm in width or girth not other wise described and applying two coats of synthetic enamel paint over a one coat of red oxide zinc chrome primer complete all as specified and as directed.
Supply and fixing 500 litre capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 20mm bore ball PTMT, valve high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed minimum weight 210 gram complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) , removing serviceable tiles to store and rubbish off the permises complete all as specified and directed.
M&L Glazed ceramic coloured tiles of size 450x300x7mm thick on vertical surface set and jointed in neat cement slurry and pointed in white or colour cement to match the shade etc including 10mm thick rendering in CM (1:4) complete all as specified and directed .
S&F SS 304 Grade Wall Mounted safety Eye wash Kit / Fountain /Shower with all connected fittings like SS Sprinklers, SS Nozzels, SS Push plate/ liver,Waste pipe etc.As per BIS 10592:1982 Make : SoleSafe or equivalent as approved by GE.
Taking down chowkats or frame with shutter (without taking out shutter from the frame) exceeding 1.50 sqm and n exc 4.00 sqm each and removal from site all as specified and directed
Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each and removal from site all as specified and directed
Taking down or up 15 mm bore galvanised iron tubing and connection including cleaning for refixing or removal all as specified
All as per item No 26 here in before but 20 mm bore
Demolition of concrete is reinforced (Reinforcement cut as required to faciliate demolition) of any descrition and in any position not other wise specially provided for complete all as specified and directed by Engineer in Charge All dismantling/demolished material removed from MOD land completely.Rate of removal outside side from MoD land deemed to be included in the same item.
Taking down cement plaster including raking out joints hacking for key and scrubbing down with water complete as specified and directed.
Taking down rain water pipe and eaves gutters (any size and pattern) including all fittings heads shoes bends swan necks etc complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar incl. all quoins arches, pillars etc. but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed.
M&L for Precast RCC slab, landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs,mangers, shelves type B1(1:2:4) and similar articles with plain faces set in cement mortar 1:4 all as spfd and directed
M&L TMT steel bars 10mm dia and over cut to length bent shape required, including cranking bending binding with mild steel wire (annealed) not less than 0.9mm dia quality conforming to relevant IS complete all as specified.
S & F GI tubing medium grade with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 15 mm complete all as specified.
All as per serial item 34 here in before but 20 mm bore
S&F factory made white color 3-Track UPVC sliding window are made of UPVC extruded profile with wall thickness of (2.3mm to 2.5mm), window profile with hollow section with multi chamber, Frame (91mmx47mm), sliding glazed sash (60mmx34mm), 1 No SS mesh sash (60mmx34mm), sliding interlock (one vertical length in each shutter) (38.4mm x29.5mm), incl glazed through 5mm thick glass with glazing bead (18mmx16mm) will be metered cut and fusion welded at all corners, including driling of holes for fixing hardware with 2 Nos touch lock, 06 Nos roller wheel and drainage of water etc making arragement of fixing of hardware, EPDM gasket(1.2 mm to 3mm) thick, GI of (1.2mm tto 1.5mm) thick in frame, 2 sliding glass sash and 1 sliding mesh sash to be inserted in required profile , frame will be fixed by wall with 8mmx100mm long fasteners complete fittings and fixtures as per manufacture's specification and direction of Engr-in-Charge. Note : Quoted rate included all above complete descritption.
M&L for 15mm thick rendering in CM 1:4 on other than fair faces of brick or concrete surfaces finished even and smooth without using extra cement all as spfd and directed.
S & F cast iron floor trap with graating of 100 mm size including jointing to waste pipe with cement joints etc complete as directed
S&F in repair vitreous china wash basin under counter oval type (536mm X 435 mm) , white, flat back, size 550 mm x 400 mm fixed over granite and including cp waste coupling, waste fitting and union complete all as specified and as directed.
S&F deck mount type pillar tap mixer cast copper alloy for iron pipe pipe and fixed with 15mm bore in repairs all as directed.
S & F 32mm dia waste fitting brass chromium plated for basin with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed.
S & F in repair PVC connection 15 mm size with CP nuts of length 600 mm etc complete all as specified.
S&F angle valves CP screwed down high pressure of fancy type chromium plated screwed both ends for iron pipe or for union and fixed with 15mm bore in repairs
S&F two way angle cock CP screwed down high pressure of fancy type chromium plated screwed both ends for iron pipe or for union and fixed with 15mm bore in repairs
S&F in repair of CP soap tray fixed to walls with rubber plugs complete all as specified and directed.
S&F in repair brass chromium plated tubular towel rail 20 mm dia D type, 60 cm long between flanges complete all as specified and as directed.
S & F 110 mm bore of pipe PVC (SWR) pipes double socket in any length with rubber ring joint laid in trenches or floor as directed
S&F in repair colour venetian blinds of 100mm width of strip with frame and fittings fixtures complete all as sfpd and directed
M&L for Mirror polishing on Old Kota stone work where ever required to give high gloss finish complete all as spfd and directed
M&L brick work in CM (1:6) with sub class ‘B’ bricks straight or curved on plane exc 6m mean readius,used in drain, boundary wall,compound wall complete all as specified and directed by engr in charge.
M&L for 20mm thick granite (of any type)work (table rubbed and polished ) in steps, jambs, pillars, window cills, cooking plateforms and like over 15mm thick screed bed in CM 1:6 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite etc complete all as specified.
Rounding to the edge of stone slabs on edge such as cooking platform
M & L for preparation of new plastered surfaces of walls and applying two coat of Oil Bound distemper over a coat of 1mm thick wall care putty on wall, complete all as specified.
M&L in repair for fixing of Aluminium composite panel of 3mm thick fixed on wall as wall paneling with making grid of 1200mm X1200mm of MS square pipe of size 25mmx25mm of 4mm thick fixed complete all as specified and directed by Engr-in-charge. Note : Pattern/design and color shall be approved by Accepting Officer. No Extra shall claim by the contractor for same. Note : Necessary scafolding rate deemed to be included in same item
M & L preparation of old painted surface of steel and iron work of any description over 10 cm width or girth and applying one coat of synthetic enamel paint etc complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) fitting such as switches, ceiling roses, pendents, regulators, sockets etc complete removing material to store for keeping in safe custody and making good disturbed surfaces of walls, floors etc all as specified as directed.
Material & Labour for concealed point wiring with single core PVC insulated and unsheathed 1100 volts grade cable with multistranded copper conductor of size 1.5 Sqmm nominal area drawn through & including non metallic rigid PVC conduit (circular/flat pvc conduit), medium duty not less than 20 mm dia concealed in wall/fixed with all fittings including tees , junction boxes, modular GI gang box & provision for modular box and modular cover of suitable size for mounting modular switches , sockets & regulators & drawing through continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with copper conductor solid conductor of size 1.5 sqmm complete all as specified & directed by Engineer -In-Charge. Note: 1) Cost for cutting chases and making good to match the existing surface shall be deemed to be included in the quoted rate. 2) Rates are deemed to be inclusive of Modular GI gang box & cover plates of any module & Qty as required on site.
For one light point/call bell controlled by one single pole switch & socket.
For one fan/exhaust fan point controlled by one single pole switch.
For one 3 pin sockets outlet 5 Amps on the same board with other switches with cable of size 1.5 sqmm
For 3 pin socket outlet 5Amps independent with cable 1.5 Sqmm size
For one 3 pin sockets outlet 15 Amps idependent with cables 2.5sqmm size
Supply and Fixing of modular switches 1 way, 6 Amp 1 module complete all as specified & directed by Engineer - In-Charge.
Supply and Fixing modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified & directed by EIC.
Supply and Fixing of modular switches 1 way, 16 Amp 1 module complete all as specified & directed by Engineer - In-Charge.
Supply and Fixing modular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified & directed by Engineer - In-Charge.
Supply & Fixing of Ceiling Rose, 3 phase polycarbonate isolated body complete all as specified & directed by Engineer - In-Charge.
Supply and fix in replacement of factory made epoxy polyster powder coated distribution board SPN 6 way fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incoming and 6 outgoings complete all as specified and confirming to IS: 8623 (Make: Legrand /Siemens). Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate.
S&F in repalcement of MCB SP 6-32 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed by Engineer -in -charge .
S&F in repalcement of MCB SPN 32 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed by Engineer -in -charge .
S&F submain wiring with unsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 4 Sqmm single core HR Grade and one run of 2.5 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB/ Geyser/ AC plug points complete all as specified and as directed. Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. Note: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.
M&L in replacement of wall fan of 450 mm sweep, 3 blade type, 1440 rpm, 80 watts with 3 speed rating suitable for AC supply, 230 volts, 50 Hz and deposit the old fan into AGE E/M store yard at Vayusenabad complete all as specified and directed by Engr-in-Charge.
S&F in replacement 2'x2' size LED panel lighting luminaire glare free illumination suitable fr false ceiling (armstrong/Grid) fitting size 600x600x70 mm (LXWXH) of 42 watts capacity recess mounting with high brightness SMD LEDs completee incl taking down old UNSV fittings all as directed by EIC,
S&F in repair false ceiling with semi perforated 12mm thick micro tegular edged GRG false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in Charge.
S&F PVC wall lining joint free consisting of 5mm thick color PVC sheet inclusive of solvent adhesive/scews and fixing at site on PVC frame as per specification and drawing. Note : Pattern/design and color shall be approved by Accepting Officer. No Extra shall claim by the contractor for same.
S&F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing.
S&F in repair of glazed ceramic coloured tiles 7mm thick 450 x 300mm size in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade. Etc including 10 mm thick rendering in CM 1:4 including dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), All dismantling/demolished material removed from MOD land completely
M & L Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors over 15 mm thick screed bed in CM (1:6) etc set and jointing in neat cement slullry and pointed in white or coloured cement to match, including dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), All dismantling/demolished material removed from MOD land completely
Material & labour for dura stone (HDVT) 15/16mm thick heavy duty outdoor tiles, matt/rustic finish of size 600x600mm in floors etc set & jointed in high performance polymer based adhesive (laticrete 315 Plus of equivalent ) to be mixed with water or latex with spacer and grout fill with MYK LATICRETE Stellar grout OR MYK LATICRETE Sanded or Unsanded Grout mixed with MYK LATICRETE 1776 Grout Admix Plus or equivalent complete all as specified and directed incl dismantling floor,hearth or wall tiling including cement motrar bedding cement mortar bedding (but not backing ) all as spfd and directed. All dismantling/demolished material removed from MOD land completely.Rate of removal outside side from MoD land deemed to be included in the same item.
M&L machine cut kota stone slab flooring 20-25 mm thick (minimum size 55 cms x 55 cms) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, mirror polishing complete.
M&L Screed bed or bedding layer of mortar 20 mm thick in CM (1:6) for laying floor finishes.
M&L for 20mm thick granite (of any type)work (table rubbed and polished ) in steps, jambs, pillars, window cills, cooking plateforms and like over 15mm thick screed bed in CM 1:6 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite etc complete all as specified.
Rounding to the edge of stone slabs on edge such as platform all as directed
Dismantling of wrought iron or Mild Steel work of any description complete all as specified and directed by EIC
M & L for Rolled Steel section (Fe -410, Grade E-250)as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
M&L for joist, channel, angle, or tee sections, (Fe -410, Grade E-250) fixed independently, without connecting plates, etc. (cut to ordinary lengths) all as directed by Engr-in-Charge
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in chajja/roof covering/cladding to wall,fixed with self tapping screws to steel frame work, as specified.
M & L for PCC 1:2:4 type B1 in lintels upto 1.5m clearspan, cills, steps; seismicand other similar bands,plinth courses, string courses,lacing courses, parapets andrailings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed.
M&L for Cement concreteType C2(1:3:6) (40mm graded aggregate) in foundations, filling and mass concrete to fix vertical post all as directed
M&L for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming toFe-290 Gde E-165
M&L for preparation of old surfaces including complete removal of old existing treatment of wall surfaces and applying two coat of Oil Bound distemper over a coat of 1mm thick wall care putty on wall,
M & L preparation of new surfaces of steel and iron work of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed.
Schedule of Credit
stage.html
html • 0.05 MB
technical_837822.pdf
techsummary_837822.pdf
finance_837822.pdf
BOQ Comparative Chart
xlsx
finsummary_837822.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
Tender.pdf
Tender Documents • 0.94 MB
BOQ_837822.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .