| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.5 LAccepted-Finance U 57 OPP AGGARWAL NURSING HOME RAJU GAS AGENCY OFFICE VIJAY NAGAR NARELA DELHI DELHI 110040 | NORTH | DELHI | 110040 | 1 | Accepted-Finance 1 | |
| 2 | 2₹9.3 L+₹80,111 (9.44%)Rejected-Finance UC I USHA PARK HARI NAGAR NEW DELHI 64 | NEW DELHI | DELHI | 110001 | 2 | Rejected-Finance 2 | |
| 3 | 3₹9.9 L+₹1.4 L (16.3%)Rejected-Finance B 17 2 GALI NO 20 JITAR NAGAR NEAR PARVANA ROAD KRISHNA NAGAR EST DELHI 51 | NEW DELHI | DELHI | 110001 | 3 | Rejected-Finance 3 |
Tender Value
₹9.6 L
EMD Value
₹20,009
Closing Date
21 Feb 2024, 11:00 amClosed
EEE-II/CLZ
EEE-II/CLZ
Construction of 5 Nos Class Rooms in M C Pry School Udhyog Nagar , 2 Class Rooms ,3 Toilet blocks for Boys and 3 Toilet blocks for Girls in M C Pry School Nithari No-02 , 1 toilet blocks for Boys and 2 toilet blocks for girls in MC Pry School Sector-
2024_MCD_186501_1
EEE-III/RZ/TC/2023-24/27.1
Open Tender
Electrical Works
Item Rate
365 days
EEE-II/CLZ
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹20,009
22 Feb 2024
16 Feb 2024
22 Feb 2024
16 Feb 2024
21 Feb 2024
16 Feb 2024
Amount
OD24445/2023-2024:(1.58) Supplying and fixing PVC Batten/ Angle Holder including connection etc. as required.
OD24446/2023-2024:(1.38) Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
OD24447/2023-2024:(2.12.2) Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
OD24448/2023-2024:(2.10.1) Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
OD24449/2023-2024:(2.3.3) Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2 + 12 double door
OD24450/2023-2024:(1.30) Supplying and fixing metal box of 180mmx100mmx60mm deep (normal size) of surface or in recess with suitable size phenolic laminated sheet cover in the front i/c providing and fixing 6pin,5/6 amps and 15/16amps socket outlet and 15/16amps piano type switch connection painting etc as required.
OD24451/2023-2024:(1.24.4)Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 Pin 5/6 amp socket outlet
OD24452/2023-2024:(1.24.1) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 Amp switch
OD24453/2023-2024:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
OD24454/2023-2024:DSR 22 (1.31) Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required
OD24455/2023-2024:DSR 22 (1.21.3)Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 32 mm
OD24456/2023-2024:DSR 22 (1.21.2)Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 25 mm
OD24457/2023-2024:DSR 22 (1.14.4 )Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
OD24458/2023-2024:DSR 22 (1.14.7 )Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(b) 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
OD24459/2023-2024:DSR 22 (1.12) Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required
OD24460/2023-2024:DSR 22 (1.10.3) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
OD24461/2023-2024:SR 22 (7.7)Laying of one no PVC insulated and PVC sheathed/XPLE Al Conductor armoured power cable of 1.1KV grade of following size on wall surface as required. Up to 35 sq,mm (clamped with 1mm thick saddle)
OD24463/2023-2024:P/F of 6 SWG dia GI wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required.
OD24466/2023-2024:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
OD24467/2023-2024:SITC of single /three phase mono block pump set complete with all accessories workable on 240/415 volts ,50 HZ AC supply .(a) 1 HP (0.75 KW) single phase pump set head from 12-30metre suction and delivery 25 X 25 mm
OD27390/2023-2024:(2.3.2) Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2 + 8 double door
OD27391/2023-2024:(5.2) Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
OD27392/2023-2024:(2.2.14) Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A,36KA,FPMCCB
OD27393/2023-2024:(1.50.1) Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. up to 450 mm sweep
OD27394/2023-2024: DSR 18 CIVIL (10.18) P/F circular/hexagonal cast iron/MS sheet box for ceiling fan clamp of internal dia.140 mm.73 mm.height top lid of 1.5mm thick MS sheet with its top surface for proper bending top lid shall be secured in to cast iron MS sheet box by means of 3.3 mm dia.be made of 12 mm.dia.MS bar bent to shape as per standard drawing complete as reqd.
OD27395/2023-2024:Providing and fixing 25mm x 5mm GI strip on surface or in recess for connections etc as reqd
OD27396/2023-2024:Supply of 15"(380mm) 1400rpm sweep exhaust fan heavy duty complete with blades, shutter etc as required
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
122.1.2:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
122.1.42:Supply of 14/15 Watt LED retrofit lamp suitable for B22 holder
122.2.2: P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
122.2.28:SITC of 60W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.150.(b):Supply, lowering and fixing following size of G.I. Pipe (M-Class) i/c cutting threading on both sides etc. ISI marked etc as reqd. 32mm(Nominal Bore)
122.2.151.(a):S & F following size of G.I. Socket. as reqd. 25mm
122.2.151.(b):S & F following size of G.I. Socket. as reqd. 32mm
122.2.152.(a):S & F following size of G.I. Union. as reqd. 25mm
122.2.152.(b):S & F following size of G.I. Union. as reqd. 32mm
122.2.153.(a):S & F following size of G.I. Elbow. as reqd.. 25mm
122.2.153.(b):S & F following size of G.I. Elbow. as reqd.. 32mm
122.2.188:S/I/T/C of LED Tube type luminaire 2X20 watt rating box type complete with extruded Al. batten prewired with high efficient LEDs with the following: (A) Total system wattage 40 watt+/- 5% (B) Luminous efficacy lumens/ watt >=95 (C) Power Factor >=0.95.
122.2.189:SITC of metal clad, powder coated, compartmentalized cubical panel board as per CPWD electrical specifications including insulated aluminum bus bars, supports, interconnection, erection of switch gears with depth 30 cm to 60 cm and making provisions for termination of incoming/ outgoing cables/ bus ducting and making foundation etc as required. (Suitable for 400 Amp TP & N)
122.2.150.(a):Supply, lowering and fixing following size of G.I. Pipe (M-Class) i/c cutting threading on both sides etc. ISI marked etc as reqd. 25mm(Nominal Bore)
OD27770/2023-2024:SR22 (1.22.2 )Supply and fixing of Metal box of 100 mm X 100 mm x 60 mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in front i/c painting etc as required
122.2.84:Supplying and fixing of full stainless steel body self-contained drinking water cooler with cooling capacity 150ltr per hr, storage capacity 150ltr and suitable for 230V supply as required.
122.2.124:Supplying AND Installation of Reverse Osmosis (RO) water purifier of capacity 50 ltr/hr complete as required.
SRI BALAJI ELECTRICALS
bharat electricals & electronics
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .