Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.0 LAccepted-AOC PO PS BOMDILA DISTT WEST KAMENG ARUNACHAL PRADESH 790001 | BOMDILA | WEST KAMENG | ARUNACHAL PRADESH | 790001 | L1 | Accepted-AOC AOC awarded due to L1 bidder | |
| 2 | L2₹57.4 L+₹5.5 L (10.5%)Rejected-Finance | L2 | Rejected-Finance BIDDER REJECTED DUE TO HIGHER BID VALUE | |
| 3 | L3₹62.4 L+₹10.4 L (20.1%)Rejected-Finance | L3 | Rejected-Finance BIDDER REJECTED DUE TO HIGHER BID VALUE | |
| 4 | L4₹64.2 L+₹12.3 L (23.7%)Rejected-Finance | L4 | Rejected-Finance BIDDER REJECTED DUE TO HIGHER BID VALUE | |
| 5 | L5₹66.4 L+₹14.4 L (27.8%)Rejected-Finance | L5 | Rejected-Finance BIDDER REJECTED DUE TO HIGHER BID VALUE |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
19 Aug 2023, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL BIRENDRA SINGH
GE 859 EWS PIN - 913859 C/O 99APO
PROVISION OF COVERED SHED FOR 05 X GENERATOR SET AT 46 INF BDE CAMP AND SPECIAL REPAIR/REPLACEMENT OF EXTERNAL WATER SUPPLY PIPE LINES STORAGE TANKS AND CONNECTED ITEMS AT AREA OF AGE E/M AND AGE B/R P
2023_MES_611230_1
8453/E8
Open Tender
Civil Works
Item Rate
270 days
BASAAKI
PL REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 859 EWS
₹99,000
Yes
11 Oct 2023
29 Jul 2023
21 Aug 2023
29 Jul 2023
19 Aug 2023
12 Aug 2023
Amount
S&F 3 layer 110 mm dia PP-R polypropylene random copolymer pipes SDR 7.4 (PN 16) UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
S&F 3 layer 75 mm dia PP-R polypropylene random copolymer pipes SDR 7.4 (PN 16) UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
S&F 3 layer 63 mm dia PP-R polypropylene random copolymer pipes SDR 7.4 (PN 16) UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
S&F 3 layer 50 mm dia PP-R polypropylene random copolymer pipes SDR 7.4 (PN 16) UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
S&F 3 layer 40 mm dia PP-R polypropylene random copolymer pipes SDR 7.4 (PN 16) UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
Description all as per item No 5 of above but of size 25 mm dia all as specified & directed
Description all as per item No 5 of above but of size 20 mm dia all as specified & directed
Supply and fix 110 mm bore outer dia PPR gave valve brass insert complete all as specified and directed.
Supply and fix 75 mm bore outer dia PPR gave valve brass insert complete all as specified and directed.
Supply and fix 63 mm bore outer dia PPR gave valve brass insert complete all as specified and directed.
Supply and fix 50 mm bore outer dia PPR gave valve brass insert complete all as specified and directed.
Supply and fix 40 mm bore outer dia PPR gave valve brass insert complete all as specified and directed.
Supply and fix 25 mm bore outer dia PPR gave valve brass insert complete all as specified and directed.
Supply and fix 20 mm bore outer dia PPR gave valve brass insert complete all as specified and directed.
S & F in replacement of 50 mm bore air release valve double chamber as per IS 14845 including mounting GI pipe and clamps as per requirement at site suitable for cast iron pipe/ ductile iron pipe incl all fittings washer, nuts & bolt etc complete all as specified and directed.Make : KIrloskar/Zoloto/Sant/Leader
S&F PVC water storage tanks of 5000 ltrs capacity rotational moulded (3 layered cylindrical vertical with closed top) ISI marked hoisted and fixed in position complete all as specified and directed.
S&F PVC water storage tanks of 2000 ltrs capacity rotational moulded (3 layered cylindrical vertical with closed top) ISI marked hoisted and fixed in position complete all as specified and directed.
M & L for road cutting incl necessary excavation 45 cm wide and 90 cm in depth as in trenches in any type of soils/rock for laying GI/PPR pipe after laying GI pipe trenches will be filling top with M&L PCC 1:3:6 type C-1 using 20 mm grdaeds stone aggregates from top over 15 cm thick hard good of broken boulders , 63 mm gauge over 15 cm bolders 100 mm dia over filled and rammed earth to make good the disburbed surface etc
M&L for cutting of existing PPR pipe 75 mm dia & inserting of Tee of 50x40x25 mm including refixing testing & commissioning etc-
M&L for PCC 1:3:6 type C-1(20 mm graded aggregate) precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete.
M&L for PCC 1:3:6 Type C2 for foundation of platform, mass concrete with 40 mm gradede coarse agreegete complete all as specified and as directed.
M & L for 15mm thick rendering on fair faces of brick,stone work/concrete surfaces of wall in CM (1:4), finished surface even and smooth without using extra cement complete all as specified and as directed.
M&L for Construction of Valve pit of size 1050cm x 1050cm x 900cm (internal dimensions) with Brick masonry construction including all necessary excavation and earth work in hard/ dense soil,returning,filling,in disposal of surplus soil to a distance not exceeding 50 m and depositing where directed , PCC in foundation of the mix (1:4:8) Type D-2 (using 40 mm graded crushed stone aggregate), PCC Pocing in PCC(1:2:4), type B0 using 12.5m crushed graded aggregate, brick masonry work in cement mortar (1:4) rendering,15 mm thick in cement mortar (1:4) internally,finished even and fair and pointing in CM 1:3 flush pointing externally . Mild steel angle iron 50x50x6mm frame work ,MS sheet cover with 3.15mm thick with handle made of flat iron 30x5 mm thick and locking arrangment including providing pad lock ( Godrej/Link/Horisson ) 50 mm size Brass , and applying two coats of synthetic enamel paint of tint as approved over a coat of red oxide primer to all mild steel surfaces and providing two coats of black bituminous paint to all embedded portion of mild steel work etc. complete all as specified and shown on drawing.
Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out hard & densile soil complete all as specified and as directed.
Returning fitting in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed.
Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
M&L Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard / dense soil.
M&L Surface dressing n exc 15 cm deep in hard/dense soil complete all as specified and directed.
M&L for Hard core, (broken srone or boulders) broken to gauge exc 63 mm and n exc 100mm complete all as specified and directed.
M&L for 100mm thick Cement concrete type C-2, 1:3:6 (using 40mm graded agg) as in foundations, filling and mass concrete
M&L for PCC 1:2:4 type B-2 using (40 mm graded stone aggregate) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases).
S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete as specified.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridge , Gutter, Gable flashing, corner flashing etc, fixed with self tapping screws as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridge , Gutter, Gable flashing, corner flashing etc, fixed with self tapping screws as specified and directed.
M&L for preparation of newly steel surface of any description, over 10cm in width or girth,not otherwise described with two coat of synthetic enamel paint over a coat of red oxide primer.
M/s 99 Enterprise of India
M/S T G ENTERPRISES
M/S L N BUILDERS
M/S TARAYANA BUILDERS
SHELLUNG CONSTRUCTION
M/S L.N. TRADERS
PARBIN SIDDIKI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .