Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹43.8 L+₹21,820 (0.50%)Rejected-Finance 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹46.8 L+₹3.2 L (7.41%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 bidder | |
| 4 | L4₹48.8 L+₹5.2 L (12.0%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 bidder | |
| 5 | L5₹49.7 L+₹6.1 L (14.0%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
23 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN-913862 C/o 56 APO
Special repair to area drainage, sewage system and special repair to security wall and view cutter at ALG of AGE B/R Dett-III under GE 862 EWS
2023_MES_577543_1
GER-74/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
Class D a(i)
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹96,000
Yes
7 Mar 2023
27 Jan 2023
25 Feb 2023
27 Jan 2023
23 Feb 2023
10 Feb 2023
Amount
Sch 'A' Part-I (B/R works) Demolition of cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
M&L for 75mm thick plain cement concrete 1:4:8, type D-2 using 40mm graded crushed stone aggregates as in sub base / floors, complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block (coloured) of any shape and size approved by EIC, ISI marked (IS:15658-2006) 60mm thick, M-35 grade (Medium Traffic), in paths and hardstanding,with grey cement and pigment, laid tightly over & including 25mm thick dry sand cushion (compacted) and joints filled with dry sand, colour and pattern as approved by GE, complete after demolition of old interlocking paver block of any size and type all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-1 using 20mm grade stone aggregate as in plinth courses, string, lacing courses, parapets and railing upto 60cm in height, coping, kneers, appx stone, bed plated, kerbs and water troughs and the like inlcuding weathering slightly rounded or chamfered aganles and throating, complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and not exceeding 10 Sqm on plan for foundation and getting out in any type of soil ,complete all as specified and directed.
M&L for plain cement concrete 1:4:8, type D-2 using 40mm graded crushed stone aggregates as in foundation, filling and mass concrete ,complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L for mild steel TMT bars 5mm dia & over upto and inlcuding 10mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as in stirrups, spacers and binders including binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L formwork to sides of concrete foundation, footings, bases of colums, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar work, in rough finished flat surface of concrete, complete all as specified and directed.
M&L formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surface of concrete, complete all as specified and directed.
M&L formwork to soffits of suspended slabs such as roof slabs, landings and similar work; n exc 200mm thick (Horizontal and sloping) for rough finished surface of concrete, complete all as specified and directed.
M&L for reinforced cement concrete M-25 (design mix) (20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns and the like, complete all as specified and directed
M&L for reinforced cement concrete M-25 (design mix) (20mm graded stone aggregates) as in columns, pillars, piers, post, struts and the like, complete all as specified and directed
M&L for reinforced cement concrete M-25 (design mix) (20mm graded stone aggregate) as Slabs supported on walls, beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and in shelves and the like, complete all as specified and directed
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for RCC beam & slabs, complete all as specified and directed.
Dismantling structural steel work including doors, gates, grills grating and framed truss etc, complete all as specified and directed.
M&L for mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks or portion framed and hung as gates, including pintel hinges, stops, hand made sliding bolt etc and similar work conforming to Fe 290 or E-165 work including welded fabricks frames, gate and framed truss etc, complete all as specified and directed.
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius, built in cement mortar 1:4 complete all as specified and directed.
Description all as per item No. 19 above but except bricks NOTE: Old brick retrieved from demolition shall be used.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work, finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of white cement primer, complete all as specified and directed.
M&L for plain cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregates) in surface channels and drains complete all as specified and directed.
M&L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide,for rough finished surfaces of concrete, complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi-tred/stopped ends etc, complete all as specified and directed.
Add or deduct for each 25 mm girth or part thereof over or under 30cm, complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick ,complete all as specified and as directed.
Removing excavated material ,not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting poin, complete all as specified and directed.
M&L for construction of septic tank, with cover slab of RCC M-30 design mix for 100 users, brick work in cement mortar 1:4 (with top of slab at ground level) including necessary filling and disposal of hard & dense soil surplus soil as directed, RCC manhole cover with angle iron welded frame ,complete with permanent speicifications, complete all as specified and shown on drawing No CE/TD 1202/2003 SH 1/2 & 2/2.
M&L for construction of soakage well 3.6 m dia and 3.00 m deep below inlet (depth) from inlet pipe to ground level 45cm including excavation and earth work in hard & dense soil, PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregates) in foundation, wall in honey combed brick work in cement mortar 1:4, cover slab of M-30 design mix, filling with brick bats, earth cushion on brick lining on top and inlet pipe 150mm bore and complete all as specified and shown on drawing No CE/TD 1202/2003 SH 1/2 & 2/2.
De-sludging of manhole, septic tank & filter beds of any description, any capacity and in any position by pumping out and removing to a distance exc 250m by mechanical mean (trolly mounted) and burring in pits all as per direction of Engr in Charge, complete all as specified and directed.
M&L for plain cement concrete 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150 mm bore SGSW pipe, complete all as specified and directed.
Supply and laying for 150 mm bore grade 'A' salt glazed stone ware pipes laid on concrete bed and jointed in cement mortar 1:1 including testing, complete all as specified & directed.
M&L for rendering 15 mm thick on fair faces of brick wall or concrete surface in cement mortar 1:4, mixed with and including water proofing compound as per manufracturer's instructions, finished even and smooth without using extra cement, complete all as specified and directed.
M&L for precast cement concrete 1:2:4, type B-1 (20mm grade crushed stone aggreagte) as in landing, cover slab, manhole cover, chajjas etc and similar articles with plain faces set in cement mortar 1:6 including necessary form work, complete all as specified and directed.
M&L for plain cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) as in apex stone, coping, benching, hold fasts, manhole covers, bed block, surface channel and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work ,complete all as specified and directed.
S&F for 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floor, complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) bend any radius, complete all as specifed and directed by Engr-in-Charge.
S&F for 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints,fixed to wall or in floor, complete all as specified and directed.
S&F for PVC (SWR) junction single (Single 'T') equal or unequal 110mm complete, all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and removing surplus soil to a distance n exc 50m and making good surface in any type of soil, complete all as specified and directed.
M&L for plain cement concrete 1:2:4, type B-2 using 40mm graded crushed stone aggregates as in mass filing to posts of fences, foundation etc, complete all as specified and directed.
S&F for rooled mild steel in joist, channel, agnle, or tee sections, fixed independently, without connecting plates, etc., (Cut to ordinary lengths i.e. within 20mm of the length as indicate) in Fe-410W Gde E-250 quality 'B', complete all as specified and directed.
S&F for 0.80 mm thick corrugated galvanised, mild steel sheeting,as in walls, roofs etc and straight flashings (length and girth as fixed) with grade of Zinc coating 275 gram / Sqm, complete all as specified and directed.
S&F for concertina coil 600 mm dia, 56 loops, 2.5mm core wire heavy galvanised (wire-275 GSM & strip-200 GSM), tensile strength of wire 1400-1500 N/Sqmm, weight 15.20 Kg/coil, stretchable length 12M inlcuding securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc after dismantling of old concertina coil of any type complete all as specified and directed.
S&F for galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line of wire to be measured) after dismantling of old unserviceble barbed wire complete all as specified and directed.
M&L for preparation of new steel surface exc 10 cm width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed by Engr-in-Chagre.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nanital or similar pattern roof covering complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
NATIONAL TRADING COMPANY
MEHTA OM PARKASH
P N Constructions
M/S BADRI NATH GUPTA
aamir farooq bhat
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .