Executive Engineer
Electrical Division -02, Vikas Minar
Renovation of club house and other miscellaneous work in DDA lake view Golf course Bhalswa.
2026_DDA_910448_1
10/EE(E)/ELD-2/DDA/2026-27( Recall )
Open Tender
Electrical Works
Percentage
60 days
As per tender documents
Please refer Tender documents.
13 documents required · 13 mandatory
₹0
₹50,834
12 Jun 2026
27 May 2026
4 Jun 2026
27 May 2026
3 Jun 2026
27 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Servicing of following ac installed in DLVGC by using foam and jet spray for both indoor and outdoor unit complete etc as required as per satisfaction of Engineer In-charge. | |||||
| 1.01 | a) Tower AC | 6 | Job | 912 | ₹5,472 |
| 1.02 | b) Split/Window | 10 | Job | 590 | ₹5,900 |
| 2 | Charging of Refrigerent/Gas in Tower/Window/Split ac and removing any leakage in piping complete as required. | 10 | Kg | 1,216 | ₹12,160 |
| 3 | Repairing and servicing of 4/6 feet air curtain installed in club house complete as required. | 4 | Job | 4,559 | ₹18,236 |
| 4 | Dismanteling, shifting and reinstalling the existing 10 mtr GI Octagonal pole at preferred location as given by secretary on the existing foundation complete as required. ( The existing foundation should be disposed out of golf course.) | 30 | Job | 2,847 | ₹85,410 |
| 5 | Providing and laying in position (1:2:4) reinforced cement concrete foundation of size 500 mm long x 500 mm wide and 1600 mm deep ( Lengh and width may change according to existing pole PCD) i/c excavation of earth, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia 1650mm long (approx.) -8 Nos. and reinforcement ring of cold twisted bar of 8 mm dia 1800 mm long (approx.)-10 Nos. (with 150 mm spacing) i/c supplying of 4 Nos. M-24 x 750 mm long (150 mm top threaded portion) GI foundation bolt (EN- 8 grade) with 3 Nos. nuts and 2 Nos. washer, bolt along with 2 Nos. templates/ Anchor plate of size 320 mm x 320 mm x 4 mm thick having 4 Nos. 26 mm dia holes to match with PCD of poles base plate with positioning of foundation bolts and providing 63 mm (OD) 2 Nos DWC pipe for cable entry and exit as required. (Drawing to be approved by Engineer in charge.) | 30 | each | 8,897 | ₹2,66,910 |
| 6 | Supplying and inastallation of Ring/round type bracket of 1000 mm dia made out of 48mm dia pipe suitable for to house 4 Nos of fitting with a canopy of 400mm on the existing 10 mtr GI octagonal pole complete as required. | 30 | Each | 6,605 | ₹1,98,150 |
| 7 | Supplying and replacement of 200 Watt Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | 80 | Each | 4,095 | ₹3,27,600 |
| 8Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | |||||
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.27 MB
BOQ_956872.xls
BOQ • 0.26 MB
NIT10.pdf
Tender Documents • 5.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .