Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.6 LAdmitted-Finance C 5 YAMUNA VIHAR DELHI 110053 | DELHI | DELHI | DELHI | 110053 | ₹48.6 L | L1 | Admitted-Finance |
| 2 | L2₹48.8 LAdmitted-Finance B 3 88 PASHCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | ₹48.8 L | L2 | Admitted-Finance |
| 3 | L3₹50.6 LAdmitted-Finance | ₹50.6 L | L3 | Admitted-Finance |
| 4 | L4₹60.9 LAdmitted-Finance | ₹60.9 L | L4 | Admitted-Finance |
| 5 | L5₹61.2 LAdmitted-Finance 4TH FLOOR VOLTAS HOUSE A BLOCK DR BABASAHEB AMBEDKAR ROAD CHINCHPOKLI MUMBAI MAHARASHTRA 400033 | MUMBAI | MAHARASHTRA | 400033 | ₹61.2 L | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | TRANSCEND CONTRACTS PVT. LTD. L4 | VOLTAS LIMITED L5 | M/S COOLREF ENGINEERS L3 | ARCHY SERVICES PRIVATE LIMITED L1 | HONEY COLLECTION L2 | COOL EARTH HVAC ENGINEERS PRIVATE LIMITED L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00SUB HEAD - 1 (SITC of VRV/VRF AC) | |||||||||
| 2.00Supply, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow (VRF)/Variable Refrigerant Volume (VRV) air cooled Outdoor (Condenser) units suitable for cooling having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual separate PCB) for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in conformation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celsius. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz ac power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio of the unit shall be as per following and complete as per CPWD specification, connections, interconnections etc. as required. Value of ISEER shall not be less than 5.4. Test certificate of OEM for unit / particular model shall be produced showing ISEER value is not less than 5.4. (Acceptable make: Any Reputed make) | |||||||||
| 2.01 | 08 HP Module for CART Office | 1 | Each | 2,55,265 ₹2.6 L | 2,39,908 ₹2.4 L | 2,32,402 ₹2.3 L | 2,60,000 ₹2.6 L | 2,55,635 ₹2.6 L | 2,68,686 ₹2.7 L |
| 2.02 | 10 HP Module for NMR Lab (01) and TEM Lab (03 - Multiple modules shall be interconnected with master-slave arrangement) | 4 | Each | 2,72,410 ₹10.9 L | 2,47,101 ₹9.9 L | 2,33,798 ₹9.4 L | 2,70,000 ₹10.8 L | 2,62,736 ₹10.5 L | 2,78,185 ₹11.1 L |
| 3.00Supply, Installation, Testing and Commissioning of following minimum capacity High wall type Indoor unit equipped with and comfort washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control with batteries as required, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase ac supply, complete as required. The Indoor units must have provision to shut down upon receiving a signal from the BMS System/Fire Signals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor) | |||||||||
| 3.01 | 1.6 TR (For CART Committee Room) | 4 | Each | 25,844 ₹1.0 L | 26,493 ₹1.1 L | 23,383 ₹93,532 | 19,500 ₹78,000 | 18,628 ₹74,512 | 29,854 ₹1.2 L |
| 3.02 | 0.6 TR (For CART Committee Room Annex) | 1 | Each | 21,399 ₹21,399 | 19,364 ₹19,364 | 20,785 ₹20,785 | 19,000 ₹19,000 | 16,444 ₹16,444 | 23,747.5 ₹23,747.50 |
| 3.03 | 2.0 TR (For TEM Lab) | 4 | Each | 26,606 ₹1.1 L | 26,493 ₹1.1 L | 27,280 ₹1.1 L | 20,500 ₹82,000 | 18,628 ₹74,512 | 33,246.5 ₹1.3 L |
| 4.00Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must have provision to shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DB and 19 degree C WB temperature. (Make will be same as of Outdoor) | |||||||||
| 4.01 | 2.0 TR (For NMR Lab) | 4 | Each | 40,385 ₹1.6 L | 42,310 ₹1.7 L | 38,972 ₹1.6 L | 41,000 ₹1.6 L | 40,475 ₹1.6 L | 48,173.5 ₹1.9 L |
Tender Value
₹52.5 L
EMD Value
₹1.1 L
Closing Date
16 Apr 2026, 3:00 pmClosed
Executive Engineer
Assistant Executive Engineer-in-charge, AC Division, Works Department, IIT Delhi, Hauz Khas, New Delhi - 110016
SITC of VRF / VRV Type AC and Split-WAC in different locations in IIT Delhi (ACCR FEB 2026)
2026_IIT_904970_1
IITD/WORKS (SP- 5282)/2026
Open Tender
Miscellaneous Works
60 days
Indian Institute of Technology Delhi Hauz Khas
Price to be quoted in given .xls format
14 documents required · 14 mandatory
₹0
₹1.1 L
6 May 2026
9 Apr 2026
17 Apr 2026
9 Apr 2026
16 Apr 2026
9 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SUB HEAD - 1 (SITC of VRV/VRF AC) | |||||
| 2Supply, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow (VRF)/Variable Refrigerant Volume (VRV) air cooled Outdoor (Condenser) units suitable for cooling having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual separate PCB) for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in conformation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celsius. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz ac power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio of the unit shall be as per following and complete as per CPWD specification, connections, interconnections etc. as required. Value of ISEER shall not be less than 5.4. Test certificate of OEM for unit / particular model shall be produced showing ISEER value is not less than 5.4. (Acceptable make: Any Reputed make) | |||||
| 2.01 | 08 HP Module for CART Office | - | Each | - | - |
| 2.02 | 10 HP Module for NMR Lab (01) and TEM Lab (03 - Multiple modules shall be interconnected with master-slave arrangement) | - | Each | - | - |
| 3Supply, Installation, Testing and Commissioning of following minimum capacity High wall type Indoor unit equipped with and comfort washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control with batteries as required, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase ac supply, complete as required. The Indoor units must have provision to shut down upon receiving a signal from the BMS System/Fire Signals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor) | |||||
| 3.01 | 1.6 TR (For CART Committee Room) | - | Each | - | - |
| 3.02 | 0.6 TR (For CART Committee Room Annex) | - | Each | - | - |
| 3.03 | 2.0 TR (For TEM Lab) | - | Each | - | - |
| 4Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must have provision to shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DB and 19 degree C WB temperature. (Make will be same as of Outdoor) | |||||
| 4.01 | 2.0 TR (For NMR Lab) | - | Each | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.70 MB
BOQ_951206.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid