| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-Finance ROOM NO 680 GANESH MURTY NAGAR PART NO 03 CAPT PRAKASH PETHE MARG COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-Finance Lowest One | |
| 2 | L2₹27.1 L+₹4.0 L (17.3%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹27.9 L+₹4.8 L (20.9%)Rejected-Finance E 84 OF HQ CWE NW MUMBAI AGE 87 1 3 GEETA NAGAR NAVY NAGAR COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹28.1 L+₹5.1 L (22.1%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹34.7 L+₹11.7 L (50.6%)Rejected-Finance 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹79,720
Closing Date
12 Dec 2022, 6:00 pmClosed
GE NW NOFRA
Dr Homi Bhabha Road New Navy Nagar Colaba, Mumbai
REPAIR REPLACEMENT OF OLD DETERIORATED STREET LIGHT POLES AND LED STREET LIGHTS GARDEN LIGHTS ALONG WITH CONNECTED WORKS AT VARIOUS LOCATIONS AT OUTLAYING AREAS UNDER GE (NW) NOFRA
2022_MES_563232_1
8091
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Mumbai
Please refer tender document
8 documents required · 8 mandatory
₹500
GE NW NOFRA
₹79,720
Yes
20 Dec 2022
15 Nov 2022
17 Dec 2022
15 Nov 2022
12 Dec 2022
29 Nov 2022
15 Nov 2022 - 28 Nov 2022
Amount
Excavation in trenches not exceeding 1.5 Mtrs. wide and not exceeding 1.5 Mtrs. in depth for foundation, laying of cablesetc and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material (Soil) n.exc 50 m and depositing where directed at a level n. exc 1.5 Mtrs. above the starting point complete all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc. 25cm depth in soil complete all as specified and directed by Engineer-in-Charge.
Cutting and removing grass, vegetation bushes etc and brooming in side/outside of water supply electric supply installation and removing all rubbish to a distance not exceeding 50 m as directed and cleaning/ brooming in water /electric supply station complete all as specified and directed by Engineer-in-Charge.
Trimming tree branches on the route of LT line nearer to LT/HT line , pump house , pipe , roof, street light fitting & poles complete all as specified and directed by Engineer-in-Charge.
Dismantling steel poles/struts, any size from existing detorated street pole complete all as specified and directed by Engineer-in-Charge.
Checking and repairs to street light fitting Junction box, cable lugs, cable joint cable brunt, MCCB, MCB, DB , earthing wire and attend each defect complaint consider one job from Highbay light, flood light , Perimeter light , Post Top Lanterns , Obstruction light, Avaition light fittings inside / out side of NT POOL, SASSON COMPLEX , BOOT POOL, TALWAR CAMP, REIVERA & HARBOUR HEIGHTS, DUXBURY, ADITI AHILYA, VISHAKHA , VANDNA AND FOMA HOUSE , fitting any height street light pole (9/11) mtrs, hanger, truss, wall repair and checking and cleaning internal complete wiring, LED Driver , bulb, ignator, holder, rectifying the defects if any including repair/replacing the unserviceable items as mentioned in below items (wherever necessary) and testing the same on ground at site for its serviceability and refixing the same at original place/location complete all as specified and directed by Engineer-in-Charge. Note :- If the contractor have not given job card to his tradesman in any working day and have not attended any complaint , the necessory recovery of Rs. 500/- per day shall be imposed by Engineer-in-charge Routine check shall be done for all types of non opps street / secutity light fitting in each and every location in routine wise manner every day by tradesman.
S&F cable junction boxes IP 66/67 weather proof for out door installation with knock outs cable entry junction box size should be 205x255x112 with terminals including complete all accessories, all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable junction box . S&F of new cable junction boxes IP 66/67 weather proof for outdoor installation (with knock outs cable entry junction box size should be 300x100x450 mm aluminium bus bar 4 strip mounted on protection insulator with two Nos and front openable hinged and locking arrangements including complete all accessories , all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable garden light. Supply and fixing of LED garden light 10 W cylindrical shaped integral decorative LED bollard with Opal acrylic diffuser and IP 65 With all acessories including PCC foundation tapper plug bolts,nuts,screwed and GI pipe 76 mm dia etc complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable garden light. S&F for post top 35 watt energy saving environmental friendly long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminiare with high power LEDs as light source complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable light. S&F in repair of new 45 watt LED new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting Source and LENs embedded toughned glass cover with IP66 Protection and impact resistance of IK07 complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable fitting. S&F of New LED Bldg security light 70 Watt indus series powder coated pressure die cast aluminium high power LED bldg security light with heat resistant toughned glass with lens with IP66 Protection , complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable fitting. S&F of 120 WATT LED street light made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable fitting. Supply & fix 120 watt JETA PRO PLUS Energy saving environmental friendly, long life,exclusive innotive die cast aluminium IP65 flood light with high power LED s as light source,suitable for high lighting architectural façade highmast and general purpose.
Supply & fix in reppcement of Industrial highbay integral LED fittings of capacity 120 watt complete and all accessories at top of any height of workshop hanger including proper hanging fixing with angle/rond bar flat iron with clamping as good appearance complete all as specified and directed by Engineer-in-Charge.
S&F in Replacement LED driver for street light / highbay light fitting / flood light 45 watt to 120 Watt of any type and size etc to match with existing complete all as specified and directed by Engineer-in-Charge.
S&F in Replacement LED driver for street light / highbay light fitting / flood light 150 watt to 250 Watt of any type and size etc to match with existing complete all as specified and directed by Engineer-in-Charge.
Supply and fix of LED lights fittings 09 Watt robustly designed IP65 of length 0.8 mtr with die cast aluminium housing, polycarbonate cover, single phase, 50Hz complete with all accessories including, all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable fitting. S&F of new 120 Watt LED flood light with pressure die cast aluminium housing with lens (IP 65 rating)) ,complete with all accessories i.e. nuts, bolts, washers etc items included and errection charge of pipe in hard stand Note : For Ser No 12 to 16 Street light 45 /70/120 watt street light any type any height and high bay light/flood light deposited to Bhagirthi MES store for repair and replace of driver as per cap and refixing at site .
Supply and fixing in repair Steel tubular swaged street light poles complete with pole arms 1.2 m & cast iron base plate ,finial taper plug,bolts,nuts and screws as specified type 410 SP-31 , 8.5 mtr long and painting with two coat of aluminium paint over one coat of primer on exposed surface of pole complete all as specified and directed by Engineer-in-Charge. (NOTE- Excavation & PCC will be measured and paid separately)
Supply & fix in replacement hot dip galvanized anti corroded weather proof octagonal electric poles 6 mtrs long top mounting on foundation complete with base plate and final including PCC foundation as per manufacturer design with 1500 mm long Arms bracket, tapper plug,bolts nuts and screws etc as specified complete all as specified and directed including taking out existing damaged pole with street light bracket complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of test Link for connecting the earth pit and down conductor complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of in repair 1x 50 sqmm copper conductor with 0.5 mm thick PVC sheathed cable complete all as specified and directed.
Taking down old unserviceable clamp and Supply and fixing iron clamp (flate 25 x 4 MM) with nuts, bolts, washers and removing old clamps complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable bracket and Supply and fixing of new bracket for street/security light fitting made of GI pipe 25 / 40 mm light grade 1.2 m long bend to shape including two Nos of clamps nuts and bolt as required complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable bracket and Supply supply and fixing of new bracket for street/security light fitting made of GI pipe 50 mm light grade 1.2 m long bend to shape including two Nos of clamps nuts and bolt as required complete all as specified and directed by Engineer-in-Charge.
M&L for straight through jointing heat shrinkable kit for cable of 150 Sqmm to 300 sqmm 3.5 core suitable for aluminium conductor including earth work complete for LT cables complete all as specified and directed by Engineer-in-Charge.
M&L for straight through jointing heat shrinkable kit for cable of 16 Sqmm to 120 sqmm 3.5 core suitable for aluminium conductor including earth work complete for LT cables complete all as specified and directed by Engineer-in-Charge.
Taking up old U/S XLPE cable size 25 sqmm to 120 sqmm insulated screened. PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor including Old concrete cable cover from trenches/walls/ceiling/poles etc any size complete all as specified and directed by Engineer-in-Charge.
Supply and lay Insulated screened PVC bedded, copper electric cables 1100 Volts grade with stranded Copper conductor of size 1.5 sq mm 2 core. laid in duct / along pole/wall etc including making connection complete all as specified and directed by Engineer-in-Charge. Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Supply and lay Insulated screened PVC bedded, copper electric cables 1100 Volts grade with stranded Copper conductor of size 2.5 sq mm 2 core. laid in duct / along pole/wall etc including making connection complete all as specified and directed by Engineer-in-Charge. Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Supply and lay Insulated screened PVC bedded, copper electric cables 1100 Volts grade with stranded Copper conductor of size 10 sq mm 4 core. laid in duct / along pole/wall etc including making connection complete all as specified and directed by Engineer-in-Charge. Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed by Engineer-in-Charge. Make :Polycab/Havells/Plaza/KEI Note : The cost of Al thimbles/lugs etc to be included in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed by Engineer-in-Charge. Make :Polycab/Havells/Plaza/KEI Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed by Engineer-in-Charge. Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed by Engineer-in-Charge. Make :Polycab/Havells/Plaza/KEI Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as directed. Make :Polycab/Havells/Plaza/KEI Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as directed. Make :Polycab/Havells/Plaza/KEI Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Taking down old unserviceable MCCB . S & F MCCB, 415 volts, 3/4 pole of cap 63 Amps, including spreader terminal/ thimble of suitable size and making connections conforming to IEC 60947-2 , complete all as specified and directed by Engineer-in-Charge.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 3.5 core. laid in duct / along pole/wall including making connection complete all as specified and directed by Engineer-in-Charge.Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Taking down old unserviceable MCCB . S & F MCCB, 415 volts, 3 pole of cap 100 Amps, 25 KA, including spreader terminal/ thimble of suitable size , making connections & incliding necessary fixing /fitting tools in this qoted rate complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable MCCB. Supply and fiixing MCCB, 415 volts, 4 pole of cap 160 Amps, 25 KA, including spreader terminal/ thimble of suitable size, making connections & incliding necessary fixing /fitting tools in this qoted rate complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable MCCB . Supply and fixing MCCB, 415 volts, 3 pole of cap 250 Amps, 25 KA, ICS = 100% ICU with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size , making connections & incliding necessary fixing /fitting tools in this qoted rate complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable MCCB .Supply and fixing MCCB, 415 volts, 3 pole of cap 630 Amps, 36 KA, ICS = 100% ICU with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size , making connections & incliding necessary fixing /fitting tools in this qoted rate complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of MCB, SPN 40/63 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of MCB SP 6-32 Amps, 240 Volts - 10 Nos , complete all as specified and directed by Engineer-in-Charge.
Supply & fix MCB , TPN 100 Amps capacity, C Curve type suitable for 415 volts AC supply, DP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed by Engineer-in-Charge. Make-Legrand / Siemens / GE.
M&L for PCC 1:3:6 type C2 (using 20mm graded stone aggreagate) for base of pole including use and wste of form work complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:2:4 for coping of pole complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Engineer-in-Charge.
S&F HDPE of pressure rating 6kg/cm sq pipe of 90 mm dia including necessary bends, elbows, Tees etc on cable protection complete all as specified and directed by Engineer-in-Charge.
S&F HDPE of pressure rating 6kg/cm sq pipe of 63 mm dia or nearest site including necessary bends, elbows, Tees etc on cable protection complete all as specified and directed by Engineer-in-Charge.
M&L for scraping the old paint from steel tublar poles by wire brush not more than up to 9/11 mtr length above ground level including street light arms applying one coat of steel primer and two coat of aluminium paint and marking pole no. , complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable recess mounting tube light . Supply and fixing serene tube light 2 x 2 fit panel 36 Watts LED luminary back lit recess mounting , CRCA housing white powder coated, with decorative polymer diffuser complete with accessories locking arrangement, clips , per wire for connection and fixing in falls ceiling all as directed by Engr -in-Charge.
Material and labour for refixng of Old uprooted lightening arrestor strips including saddling of strips with suitable saddles and nails all as directed at site by Engineer - in - Charge.
M&L in replacement Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strips 25 x 4 mm
Material and labour for refixng of Old uprooted Air Termination Rods including saddling with suitable saddles and nails all as directed at site by Engineer - in - Charge.
M&L in Replacement Air termination, single pointed aluminium rod 12mm dia and 300mm long
Supply and fixing of 4 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through ISI marked with accessories fixed on pole/wall/ceiling/truss etc complete
Testing of earthing for earth resistance provided for various electrical panels/bldgs/main DBs etc all as per clause 19.146.3 of SSR part-I and recording the test results complete including providing earth megger and test leads (Note :- The results are to be recorded in register as directed by Engineer-in-charge)
Material and labour for fault finding on HT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge.
ORIENT ELECTRIC CO
shree arihant constrution
NOEL ENGINEERS
Darpan Construction
SHREE JAGDISH FURNITURE CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .