Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹42.7 L+₹15,338.43 (0.36%)Accepted-AOC | L2 | Accepted-AOC L2 | |
| 3 | L3₹43.2 L+₹60,481.88 (1.42%)Accepted-AOC VILLAGE PO KANOH TEHSIL BARSAR DISTT HAMIRPUR HP | HAMIRPUR | HIMACHAL PRADESH | 174304 | L3 | Accepted-AOC L3 | |
| 4 | L4₹44.7 L+₹2.1 L (4.99%)Accepted-AOC | L4 | Accepted-AOC L4 | |
| 5 | L5₹49.6 L+₹7.0 L (16.5%)Accepted-AOC R O SUJANPUR TEHSIL DISTT HAMRIPUR | L5 | Accepted-AOC L6 |
Tender Value
₹53.9 L
EMD Value
₹86,402
Closing Date
29 Jul 2021, 11:00 amClosed
EE JSV Division Barsar
EE JSV Division Barsar
(SH CO Infiltration gallery 40 mtrs long, Pump House, Raw water clear water tank 40000 liters capacity each, Sedimentation tank 20000 liters, filters beds 2 units clear water tank sump well 20000 liters
2021_HPIPH_50183_1
EE-JSV-BSR-TA-21-22 9151-9200
Open Tender
Civil Works
Item Rate
150 days
Sub Division Barsar
Please refer Tender documents.
7 documents required · 7 mandatory
₹800
Yes
EE JSV Division Barsar
₹86,402
Yes
9 Dec 2021
22 Jul 2021
29 Jul 2021
22 Jul 2021
29 Jul 2021
22 Jul 2021
22 Jul 2021 - 29 Jul 2021
Amount
Excavation in foundation , trenches etc., in all kinds of soil such as pickwork, jumper work blasting work, in soft / hard rock, including chiseling wedging out of rocks clearance of bushes etc.including shoring, dewatering etc. in all leads and lifts stacking the excavated soil upto any lead and lift clear from the edge of excavation and then returning the stacked soil in 15cm layers when required into plinth , sides of foundation etc. consolidating each deposited layers by ramming and watering and then disposing of all surplus earth within all leads and lifts complete to the entire satisfaction as directed by the Engineer-in-charge of the site of work.
Earth work without dewatering
Earth work with dewatering
Providing and Laying cement concrete1:3:6 (1Cement :3Sand:6 graded stone aggregate 40 mm nominal size) including curing complete excluding the cost of form work in foundation and plinth in all leads and lifts.
Providing and Laying cement concrete1:6:12 (1Cement :6Sand:12 graded stone aggregate 40 mm nominal size) including curing complete excluding the cost of form work in foundation and plinth in all leads and lifts.
Providing and Laying cement concrete 1:1.5:3 nominal size (1Cement :1.5 Sand:3graded stone aggregate 20 mm nominal size) & curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :-
In sloppy portion in all leads and lifts. in all leads and lifts.
Foundation and plinth in all leads and lifts. in all leads and lifts.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centring, shuttering , strutting and propping etc. with wooden battens and ballies height of propping and centering below supporting floor to ceiling not exceeding 4meters and removal of the same for insitu reinforced concrete and plain.
Flat surfaces such as soffits of suspended floors, roofs, landings and the like floors etc. above 200mm. In thickness with in all leads and lifts & to the entire satisfaction of the Engineer-in-charge
Vertical surfaces such as walls(any thickness) partitions and the like including attached pilasters, buttresses, plinth and string courses and the like complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Sides and soffits of beams, beams hunching, cantilevers, bressumers and lintles not exceeding 1 meter in depth in all heights from floor complete in all respects in all leads and lifts
Providing in RCC work smooth finishing of the exposed surface with cement mortar 1:3 (1 cement : 3 sand) with in all leads and lifts & to the entire satisfaction of the Engineer-in-charge.
Squared rubble stone masonry coursed with hard stone of approved quality in foundation & plinth including racking out of joints in cement mortar 1:6 ( 1 cement :6 sand ) in all leads & lifts
Brick work using common burnt clay building bricks (IInd class) in in super structure above plinth level upto floor two level in cement mortar 1:6 (1cement:6 sand) in all leads and lifts..
Stone/ Boulder filling behind the long wall facing toward upstream side of infilteration gallery/ under floor/ behind retaing wall complete in all leads and lifts
Steel work welded in built up sections,trusses & framed work, including cutting ,hoisting & fixing in position & applying a priming coat of red lead paint :- In grating, framed ,guards,bars, ladders, railing, brackets & similar works in all leads and lifts..
Laying jointing and testting of GMS pipe following dia (medium/ light class) for scour pipe, inlet pipe , over flow pipe & distribution system including carriage of material in all leads & lifts.( Labour rates.)
150 mm dia .
65 mm dia .
Providing and fixing double flanged C.I sluice valve of following dia (with hand wheel) as per IS: 780 (including brass spindleand as per IS: 2906 Class-II complete with bolts., nuts, rubber insertion etc. ( along with tail pieces if required) following dia including all leads and lifts complete. ( Bir make) with M.S. flanges of table 5.
150 mm dia .
65 mm dia .
Constructing chamber for sluice valves with C.I surface box 100mm top diameter, 160mmbottom diameter and 180mm deep (inside with chained lid and RCC top slab1:2:4(1cement:2sand: 4 graded stone aggregate 20mm nominal size ) 100mm thick foundation concrete 1:5:10 (1cement :5sand:10 graded stone aggregate 40mm nominal size ) and insideplastering with cement mortar 1:3(1cement:3sand) finished with a floating coat of neat cementincluding curing complete with 600x600x750mm inside size with 150mm thick wall of RCC 1:2:4 ( 1cement :2sand :4 graded stone aggregate 20mm nominal size ) complete with formand reinforcment with 6mm bars at not exceeding 150mm centres both ways in all leads andlifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and fixing CI Man hole cover with frame having frame size of 500mm internal dia (Medium duty) The Weight of cover & frame should not less than 116kg including carriage ofmaterial in all leads & lifts.
Providing and fixing SFRC Man hole cover with frame having frame size of 560mm internal dia (Medium duty) The Weight of cover & frame should not less than 100kg including carriage ofmaterial in all leads & lifts.
Providing and Laying cement concrete M25 ( Design Mix) not leaner than ) 1:1.5:3 nominal size (1Cement :1.5 Sand:3graded stone aggregate 20 mm nominal size) & curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :-
In foundations,footings bases of columns and the like and mass concrete in all leads and lifts. in all leads and lifts.
Walls (any thickness but not less than 0.10 metre thickness) including attached pilasters buttersses ,plinth and string courses etc. from top of foundation upto floor two level in all leads and lifts.
Suspended floors,roofs,landing shelves and their supports balconies beams,girders bressumers and cantilever upto floor two level including carriage of material in all leads & lifts.
Providing and laying damp proof course 38mm thick with cement concrete 1:2:4 (1 cement:2 sand:4 stone aggregate 12.5mm nominal size) and curing complete in all leads & lifts
Applying a coat of hot bitumen (mexphalt 80/100 or equivalent) using 1.70 kg. per square metre on damp proof course after cleaning the surface with a piece of cloth lightly soaked with kerosene oil in all leads and lifts..
Providing wood work in frames of doors, windows and other frames wrought framed and fixed in position with second class deodar wood in all leads and lifts.
Providing and fixing wood paneled glazed or paneled and glazed shutters for doors, windows and clear story 40mm thick windows including bright finished black enameled iron with necessary screws with second class deodar wood 40mm thick in all leads and lifts.
Providng and fixing wire gauge shutters using GMS wire guage of IS gauge designation 85 G with wire of dia 0.56 mm for doors, windows & clerestory windows including bright finished black enamelled iron hinges with necessary screws.2nd class deodar wood.40mm thick including 6 mm thick PVC solid sheet with required adhesive in all leads and lifts.
Providing and Laying cement concrete 1:2:4 (1Cement :2 Sand:4graded stone aggregate 20 mm nominal size) & curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :-
Suspended floors,roofs,landing shelves and their supports balconies beams,girders bressumers and cantilever upto floor two level including carriage of material in all leads & lifts.
Cement concrete flooring 1:2:4(1cement:2sand:4 graded stone aggregate 20mm nominal size) laid in one layer finished with a floating coat of neat cement (40mm thick) in all leads and lifts.
20 mm cement plaster in single coat of rough sides of bricks/concrete stone walls for interior plastering upto floor two level including arrises internal rounded angles chamber and rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:6(1cement:6sand) in all leads and lifts.
6 mm cement plaster to ceiling in cement mortar 1:3 (1Cement :3 Sand) in all leads and lifts.
Providing plinth protection 50mm thick in cement concrete 1:3:6 (1cement:3sand:6 graded stone aggregate 20mm nominal size) including finishing of the top surface of concrete smooth in all leads and lifts.
Providing tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level including carriage of material in all leads & lifts.
Applying two coats of wood preservative on new wood and wood based surfaces after and including preparing the surface by thoroughly cleaning oil,grease, dirt and other foreign matter,sand papering and knotting.
Applying priming coat over new wood and wood based surface after and including preparing the surface by thoroughly cleaning oil dirt grease and other foreign matter sand papering and knotting ready mixed paint brushing wood primer pink in all leads and lifts.
Painting two coats (excluding priming coat) on new wood and wood based surface with ready mixed paint brushing the give and even shade including cleaning of all dirt dust and other foreign matter and sand papering and stopping with ready mixed paint other than white in all leads and lifts.
White washing with lime on undecorated walls surface (two coats) to give an even shade including thoroughly brooming the surface dirt dust mortar dirt and other foreign matter in all leads and lifts.
Finishing wall with water proof cement paint of approved brand and manufactuers and of required shade on undecorated wall surfaces ( two coats) to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered material in all leads and lifts
Providing and fixing M.S.fan clamp(Type-I of 16mm dial M.S. Bar bent to shape with hooked ends in RCC. Slab during laying including painting the exposed portion of loop all as per standard design complete in all leads and lifts.
Providing 40x3mm flat iron hold fast 40cm long including fixing to frame with 10mm dial meters bolts and nuts and wooden plug and embeding in cement mortar block 30x10x15cm 1:3:6(1cement:3sand:6 graded stone aggregate 20mm nominal size in all leads and lifts..
Providing and fixing following anodized aluminium fittings of anodized transparent and shade with necessary screw etc.complete
Sliding door bolts 250x16mm.
M.S. tower bolts (Barrel type) leads and lifts. 200x10mm.
M.S. tower bolts (Barrel type) leads and lifts.150x10mm.
M.S. tower bolts (Barrel type) leads and lifts. 100x10mm.
M.S. handles 125 mm dia
M.S. handles 100 mm dia
Providing and fixing M.S. round or square bars 16mm dia at required spacings in wooden frames of windows and clerestory windows complete in all leads and lifts.
Precast concrete block masonry in partition walls 10 cm. thick with solid block of approved size including quion blocks, jamb blocks, closer etc. made of cement concrete 1:3:6 (1 cement:3 sand:6 graded stone aggregate 40mm and down gauge I cement mortar 1:3( 1cement:3sand ) in all leads and lifts.
Providing and placing the filter media in horisontal layer duly graded, screended and cleaned as per specification complete in all respecrts and in all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Top layer :- Fine sand effective size : 0.20 to 0.40 mm and uniformity co-efficient (2-3) .
2nd layer:- Coursed sand 3 mm to 6mm .
3rd Layer :- 6 mm to 20mm
4th Layer Bajri :- 20mm to 25mm
Bottom Layer :- Broken stone 50mm to 75mm
AVINASH THAKUR
Anurag Deep
SUNIL VERMA
RAJE ENGINNERING WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .