Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹31.0 LAccepted-Finance VILLAGE KARTHOLI NATIONAL HIGHWAY BARI BRAHAMANA JAMMU JAMMU KASHMIR 181133 | SAMBA | JAMMU AND KASHMIR | 181133 | 1 | Accepted-Finance qualified | |
| 2 | 2₹35.4 L+₹4.4 L (14.3%)Accepted-Finance TEHSIL TRINTHA DISTRICT REASI 182311 JAMMU AND KASHMIR | REASI | JAMMU AND KASHMIR | 182311 | 2 | Accepted-Finance qualified | |
| 3 | 3₹35.6 L+₹4.7 L (15.0%)Accepted-Finance | 3 | Accepted-Finance qualified | |
| 4 | 4₹39.3 L+₹8.3 L (26.9%)Accepted-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | 4 | Accepted-Finance qualified | |
| 5 | 5₹40.9 L+₹9.9 L (32.0%)Accepted-Finance | 5 | Accepted-Finance qualified |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
6 Mar 2021, 4:00 pmClosed
Executive Engineer
Electric Division JPDCL Udhampur
Erection of HT and LT line with creation of substations
2021_PDD_118419_1
ED/UDH/30 of 2020-21, dt 26-02-2021
Open Tender
Electrical Works
Turn-key
30 days
District Udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer Electric Division JPDCL
₹80,000
10 Jul 2021
27 Feb 2021
8 Mar 2021
27 Feb 2021
6 Mar 2021
27 Feb 2021
27 Feb 2021 - 2 Mar 2021
Supply, Transportation, carriage, erection, testing and commissioning for laying of 2.5 km 11KV HT line on 9/11 mtr ST poles with weasel conductor at Mansar and Debrah
9 mtr long ST Pole (ST-410SP33) for HT Line
11 mtr long ST Pole (ST-410SP56)
GI V cross-arm with top Bracket including clamp
GI Channel X-arm including clamps and braces
0.03 ACSR Weasel conductor
PG Clamps for 0.03 ACSR Weasel Conductor
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
11KV Pin Insulator (Polymeric) with Pins (12kv, 5KN) Creepage Distance 320mm
11KV Disc Insulators (Polymeric 45KN ) creepage distance 320 mm with tension fittings
Earthing complete by GI Rod 20 mm 2.5 mtr long through G.I Strip 25X3 mm in HT Lines
Painting of 11 mtr ST poles including crossarms/clamps with Red oxide Paint (1 coat) (Asian/Nerolac Make )
Painting of 11 mtr ST poles including crossarms/clamps with Aluminium Paint (2 coat) (Asian/Nerolac Make )
Painting of 9 mtr ST poles including crossarms/clamps with 1 coat of Red oxide Paint (Asian/Nerolac Make )
Painting of 9 mtr ST poles including crossarms/clamps with 2 coat of Aluminium Paint (Asian/Nerolac Make )
Cement bottoming 1:2:4 mix as per REC standards
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
Supply, Transportation, carriage, erection, testing and commissioning for creation of 1 no 250KVA Distribution Transformer at Mansar
11/0.433kV, 3-phase 250KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, Copper wound for 250kVA rating and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
300 mm² (2 ckt), 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
9 mtr. Long ST Pole (ST-410 SP33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution Box with MCCB for incomer & SFU's for Outgoing Circuits ( For 250 KVA Substation)
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge Connectors / PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
3-Ø, 4-Wire Trivector Meter with CT
Cement bottoming 1:2:4 mix as per REC standards
Painting of ST Poles 9mtr of substation including cross arm, clamps with1 coat of Red Oxide (Asian/Nerolac Make )
Painting of ST Poles 9 mtr of substation including cross arm, clamps with 2 coats of Aluminium Paint (Asian/Nerolac Make )
Supply, Transportation, carriage, erection, testing and commissioning for creation of 2 no. 100KVA Distribution Transformer at Debrah
11/0.433kV, 3-phase 100KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, Aluminium wound for 100kVA rating and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
185 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
9 mtr. Long ST Pole (ST-410 SP33)
11kV Polymeric composite Disc Insulator 12kV, minimum failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution Box with MCCB for incomer & SFU's for Outgoing Circuits ( For 100 KVA Substation)
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge Connectors / PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
3-Ø, 4-Wire Trivector Meter with CT
Cement bottoming 1:2:4 mix as per REC standards
Painting of ST Poles 9mtr including cross arm,clamps with 1 coat of Red Oxide (Asian/Nerolac Make )
Painting of ST Poles 9 mtr including cross arm, clamps with 2 coats of Aluminium Paint (Asian/Nerolac Make )
Supply, Transportation, carriage, erection, testing and commissioning for laying of 0.65 km 3-ph 4-wire on 8/9 mtr ST poles with weasel cond
8 mtr. Long ST Pole (ST-410 SP15)
9 Mtr Long ST Pole (ST-410 SP33)
GI M-Clamps for Shackle Insulators
0.03 ACSR Weasel Conductor
16kN Polymer Shackle Insulators
Galvinized Nuts and Bolts.
Earthing Complete GI Rod 20mm 2.5 mtr long through GI Strip.
Painting of ST Poles 8 mtr including cross arm,clamps with 1 coat of Red Oxide (Asian/Nerolac Make )
Painting of ST Poles 9mtr including cross arm,clamps with 1 coat of Red Oxide (Asian/Nerolac Make )
Painting of ST Poles 9 mtr including cross arm, clamps with 2 coats of Aluminium Paint (Asian/Nerolac Make )
Painting of ST Poles 8 mtr including cross arm, clamps with 2 coats of Aluminium Paint (Asian/Nerolac Make )
Cement bottoming 1:2:4 mix as per REC standards
LT Line Spacers
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut- bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
M/S SURAJ PARTAP SINGH
AJAY KAPOOR
vijay builders
M/S JCM CONSTRUCTIONS
M/S VAISHNO TRADERS
R S CONSTRUCTION
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .