Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC 131 SANGAM NAGAR OPP NATIONAL SCHOOL SANGHVI PUNE 411027 | PUNE | MAHARASHTRA | 411027 | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹22.4 L+₹3.4 L (17.9%)Rejected-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L2 | Rejected-AOC Bidder not quoted L1 rates | |
| 3 | L3₹23.5 L+₹4.5 L (23.8%)Rejected-AOC | L3 | Rejected-AOC Bidder not quoted L1 rates | |
| 4 | L4₹26.3 L+₹7.3 L (38.7%)Rejected-AOC | L4 | Rejected-AOC Bidder not quoted L1 rates | |
| 5 | L5₹26.8 L+₹7.8 L (41.0%)Rejected-AOC 22 319 GALI NO 5 MAHABIR PARK BAHADURGARH 124507 HARYANA | JHAJJAR | HARYANA | 124507 | L5 | Rejected-AOC Bidder not quoted L1 rates |
Tender Value
Refer Docs
EMD Value
₹57,000
Closing Date
21 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SOUTH PUNE
NO 1 GENERAL BHAGAT MARG PUNE 411040
8311 MAINTENANCE AND REPAIRS TO SECURITY LIGHT FITTINGS, CABLE, POLES, STREET LIGHT LUMINARIES AND MISC WORK IN THE AREA OF No. I AND OTHER CONNECTED AREA UNDER GE SOUTH PUNE
2021_MES_489450_1
8311 GE SOUTH PUNE
Open Tender
Civil Works
Item Rate
273 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹57,000
Yes
7 Feb 2022
20 Nov 2021
23 Dec 2021
20 Nov 2021
21 Dec 2021
7 Dec 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in following type of soil complete all as specified and as directed :-
Soft/Loose soil
Hard / Dense soil
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed .
Supply, lay, joint, test and commissioning of LT under ground cable XLPE insulated and sheathed heavy duty armoured with aluminium conductor 1100 volt grade with cable glands, lugs etc including taking up Old unserviceable cable complete of following size :-
06 sqmm 4 core
10 Sqmm 4 core
16 Sqmm 4 core
Material and labour for Reinforced concrete pipes, class NP2 with one collar per length of pipe of dia 100mm, half round (02 Nos for top & bottom) complete all as specified and as directed.
Supply and lay in trenches G I Tubing light grade for protection of cable complete with all accessories of the following size : -
50 mm bore
80 mm bore
100 mm bore
Taking down old unserviceable conventional street light fittings from pole/ building and supply and fix street light fittings Pressure die cast aluminium housing, heat resistance toughened glass with frame LED street light luminaries, IP-66 complete with driver and all standard accessories of capacity 70 Watt LED including necessary fixing arrengements connection complete all as specified and directed. (Make - Havells Cat Part No. ENDURAPEARLPLUSSL70WLED757SASYTOPC or of equivalent model in Wipro / HPL / Bajaj)
Taking down old unserviceable conventional street light fittings from pole/ building and supply and fix LED street light fittings, Pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP-66 protection complete and all standard accessories of capacity 90 Watt LED including necessary fixing arrengements, connection complete all as specified and directed (Make - Havells Cat Part No. ENDURACITYLINERNEOSL90WLED757SASYBOTG or of equivalent model in wipro/HPL/Bajaj)
M&L in replacement of PVC insulated and sheathed 1100 volt grade of size copper wire 2.5 sqmm copper 3 core for connection of street light fitting from over head line/ pole box complete all as specified and as directed.
Taking down unserviceable old bracket from street light pole and supply and fix new street light bracket made out of MS pipe 40mm bore heavy duty not exceeding 1.5 mtr in length including 2 Nos. MS Clamp of suitable size with fixing arrangements (welding etc) to fix the bracket on pole all as specified and directed.
Taking down existing conventional flood light fittings and supply and fix LED lamp type flood light fittings, pressure die cast housing with IP 66 protection of capacity 100 watt suitable for operation on 230 volt 50 Hz AC supply complete with all standard accessories and necessary fixing arrangements complete all as specified and as directed. (Make - Havells Cat Part No. JETAIRISFLS100WLED757SYMLTG or of equivalent model in Wipro / HPL / Bajaj)
Taking down existing conventional flood light fittings and supply and fix LED lamp type flood light fittings, pressure die cast housing with IP 66 protection of capacity 150 watt suitable for operation on 230 volt 50 Hz AC supply complete with all standard accessories and necessary fixing arrangements all as specified and as directed. (Make - Havells Cat Part No. JETAIRISFLS150WLED757PSYMLTG or of equivalent model in Wipro / HPL / Bajaj)
Supply and fix in repairs garden security light fittings LED type suitable for 10 watt LED inverted pyramid tripod type LED bollard with soft 360 light, IP 65 protection, resistance to corrosion complete with necessary fixing arrangements, PCC (1:3:6 ) in foundation suitable for operation on 230 volt 50 Hz AC supply including all standard fittings and fixture all as per the direction (Make :- Crompton Cat Part No LBLSN-10-CDL or equivalent model in Wipro / HPL / Bajaj)
Taking out existing unserviceable junction box from pole/building and Supply and fix Junction box [FRP] of size 300x200x100 mm complete with Bakelite connector 100 amps capacity 4 way,MCB SP 10 amps capacity with necessary fixing arrengements by providing MS clamps 2 nos made out of MS flat 25x5 mm including nut bolts etc complete all as specified and as directed.
M&L for taking down existing LED fitting 18/20 watt and supply and fix LED Batten 20 Watt capacity on surface and wall mounted with polycarbonate housing & integrated electronic driver including standard accessories complete all as directed or specified. (Make - Havells Cat Part No. LUMILINEBS20WLED830SPCWH or equivalent model in Bajaj / HPL / Wipro)
Taking down unserviceable post top/gate light and supply and fix LED Post top light fitting for 360 degree indirect light, IP 65 protection, resistant to impact and corrosion, glare free and better uniformity, including necessary fixing arrangements as required at site complete of capacity 35 watt complete all as specified and as directed (Make - Havells Cat Part No. CORALPT35LED757PSYMTOPC or of equivalent model in Wipro / HPL / Bajaj / Orient)
Taking down unserviceable post top/gate light and supply and fix LED Post top light fitting for 360 degree indirect light, IP 65 protection, resistant to impact and corrosion, glare free and better uniformity, including necessary fixing arrangements as required at site complete of capacity 70 watt complete all as specified and as directed. (Make - Bajaj Celesta or of equivalent model in Havells / HPL / Crompton /Orient)
Taking down old unserviceable conventional street light fittings from pole/ building and supply and fix street light fittings Pressure die cast aluminium housing, IP 66 Proptection, heat resistance toughened glass with frame LED street light luminaries complete with driver and all standard accessories of capacity 20 Watt LED including necessary fixing arrengements with GI Pipe 25mm and MS clamp 02 Nos, necessary connection etc all as specified and directed by Engineer-in-charge (Make :- Havells Cat Part NO. ENDURAPEARLSL20WLED757SASYTOPCMP or of equivalent model in Wipro / HPL / Bajaj)
Supply and fix in repairs electronic driver suitable for 20/25 watt LED street light fittings complete for 230 volt 50 Hz AC Supply complete all as specified and as directed.
All as per Sr. Item No. 19.00 above but suitable for 60 to 72 Watt LED street light fittings complete for 230 volt 50 Hz AC Supply complete all as specified and as directed.
All as per Sr. Item No. 19.00 above but suitable for 100 to 120 watt LED street light fittings complete for 230 volt 50 Hz AC Supply complete all as specified and as directed.
All as per Sr. Item No. 19.00 above but suitable for 140 to 160 watt LED flood light fittings complete for 230 volt 50 Hz AC Supply complete all as specified and as directed.
Supply only surge protection device compatible with industrial and outdoor LED street light/flood light fitting upto rated power of 75 watt, 5 KV complete all as specified and as directed.
All as per Sr. Item No. 23.00 above but rated power of 75 watt and upto 150 watt, 5 KV complete all as specified and as directed.
Material and labour for painting of steel tubular pole 9 m height including cross arm, clamp, back plate etc in situ on with one under coat and one finishing coat with aluminium paint after cleaning preparation of surface including making alternate white and black strip 30 cm wide 5 Nos. with two coats of synthetic enamel paint complete all as specified and as directed.
M&L for testing and fault locating of HT cable with the help of bringing Cable fault locating machine at site complete all as specified and as directed. (Note - The machine for locating of fault will be arranged by the contractor and the quoted rate is included.)
M&L for testing and fault locating of LT cable with the help of bringing Cable fault locating machine at site complete all as specified and as directed. (Note - The machine for locating of fault will be arranged by the contractor and the quoted rate is included)
S&F in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 150 to 240 Sqmm 3.5 core including all accessories required complete all as specified and as directed.
All as per Sr. Item No. 28.00 above but cables 95 to 120 Sqmm 3.5 core including all accessories required complete all as specified and as directed.
All as per Sr. Item No. 28.00 above but cables 35 to 95 Sqmm 3.5 core including all accessories required complete all as specified and as directed.
Supply & fix timeline distribution board, timeline 32Amps 3 pole, 230 volts with analog time switch Cat Part No TL032ABO of Indo Asian or equivalant to L&T/Havells/Schneider, to be fixed for wall and pole with mounting arrangement all as specified and directed.
Supply & fix timeline distribution board, timeline 32Amps 3 pole, 230 volts with Astronomincal time switch Cat Part No TL032ASO of Indo Asian or equivalant to L&T/Havells/Schneider, to be fixed for wall and pole with mounting arrangement complete all as specified and directed
Supply and fix in repair 3 pole Power Contactors - 415 Volt AC rating AC3,-185 Amps conforms to IS/IEC 60947-4-1. Cat Part No 850227,HSN CODE 8536 of Indo Asian(Opticon) or equivalant to L&T/Havells complete all as specified and as directed.
Supply and fix in repair 3 pole Power Contactors - 415 Volt AC rating AC3,-225 Amps conforms to IS/IEC 60947-4-1. Cat Part No 850237,HSN CODE 8536 of Indo Asian(Opticon) or equivalant to L&T/Havells complete all as specified and as directed.
Supply and fix in replacement MCB SPN 20-40 Amps, 230 volts,10 KA, 'C' series complete all as specified and as directed.
Supply and fix in replacement MCB TPN 16-32 Amps, 415 Volts complete all as specified and as directed.
Supply and fix in replaement of MCCB 250 Amps, 25 KA, 4 Pole, 415V with thermal release complete all as specified and as directed.
Supply and fix in replacement of MCCB 200 Amps, 25 KA, 4 Pole, 415V with thermal release complete all as specified and as directed.
Supply and fix in replacement of MCCB 63 Amps, 16 KA, 4 Pole, 415V with thermal release complete all as specified and as directed.
Supply and fix in replacement of MCCB 100 Amps, 16 KA, 4 Pole, 415V with thermal release complete all as specified and as directed.
Supply and fix in replacement of MCCB 125 Amps, 16 KA, 4 Pole, 415V with thermal release complete all as specified and as directed.
M & L for earthing with galvanised steel earth plate electrode 600 x 600 x 6.3 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to a depth of not less than 1.5 m below ground level connected to and incl GI wire 4 mm dia and GI pipe 15 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I incl RCC cover, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit incl excavation and earth work in any type of soil / strata on completion etc complete all as specified and directed by Eng-in-Charge.
metro electrical services
SHRI SWAPNAYOG ENTERPRISES
RAJKUMAR KISHANCHAND JASWANI
R R Associates
TULAJA ENTERPRISES
CHAITANYA WINDWELL
ASHWAMEDH ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .