Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 LAccepted-AOC | ₹6.7 L | L1 | Accepted-AOC work order has been awarded |
| 2 | L2₹7.2 L+₹49,504.60 (7.41%)Rejected-Finance A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | ₹7.2 L+₹49,504.60 (7.41%) | L2 | Rejected-Finance Not L1 |
| 3 | L3₹8.1 L+₹1.4 L (21.5%)Rejected-Finance | ₹8.1 L+₹1.4 L (21.5%) | L3 | Rejected-Finance Not L1 |
Tender Value
₹9.1 L
EMD Value
₹20,000
Closing Date
20 Jul 2026, 1:00 pmClosed
EEE-I
MUNICIPAL CORPORATION OF DELHI Office of the Executive Engineer (Elect)-I Room No.5 First Floor Vishwakarma Nagar Near Hanuman MandirJhilmil Colony Delhi-110095
Provision of 04 Nos. Semi High Mast Light Poles with LED lights in Mayur Kunj Society, Patparganj Village in Ward No. 197, AC-57 (Patparganj) under Shahdara (South) Zone.
2026_MCD_283948_1
EEE-I/2026-27/2.3
Open Tender
Electrical Works
Percentage
60 days
work
Please refer to tender documents
4 documents required · 4 mandatory
₹590
₹20,000
18 Sept 2026
13 Jul 2026
20 Jul 2026
13 Jul 2026
20 Jul 2026
13 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earthing with GI earth pipe 4.5 Metre long, 40mm dia i/c accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/coke and salt) as required. | 8 | Set | 5,958 | ₹47,664 |
| 2 | Providing and Fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. | 16 | metre | 84 | ₹1,344 |
| 3 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm | 168 | metre | 47 | ₹7,896 |
| 4 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm | 70 | metre | 36 | ₹2,520 |
| 5 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm | 250 | Metre | 95 | ₹23,750 |
| 6 | Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 Hz, Operating temp range -15 deg to 50deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66, IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR -15 , lenses for beam angle 30deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (Asper ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single corecable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 150 W | 24 | Each | 3,602 | ₹86,448 |
| 7 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplersetc. conforming to IS 14930, Part II complete with fitting andcutting, jointing etc..direct in ground (75 cm below ground level)including excavation and refilling the trench but excluding sandcushioning and protective covering etc., complete as required.(a) 63 mm dia (OD-63 mm & ID-51 mm nominal) | 130 | Metre | 289 | ₹37,570 |
| 8 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplersetc. conforming to IS 14930, Part II complete with fitting andcutting, jointing etc. in theexisting trench , complete as required.(a) 63 mm dia (OD-63 mm & ID-51 mm nominal) | 38 | Mtr | 136 | ₹5,168 |
| 9 | Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh i/c MV danger plate and grounding the protection system in suitable quality of CC etc as reqd. | 48 | sqm | 1,108 | ₹53,184 |
| 10 | Fabrication,Supplying,Installation,testing,Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick (Single dip ) inside and out sides and suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumfrential weld. It should also included accessories For High Mast head frame ,2 point suspension system with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. flood light luminaries symmitrically And its control gears boxes and lighting finial ,the mast shall have integral type manual raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC(1:2:4) shallow foundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in possion, reinforcement of cold twisted bars of 12 mm dia-2100mm long(approx)-16 nos. and reinforcement of cold twisted bars of 8 mm dia-3700 mm (approx)-13 nos. (with 150mm specing ) as required with positioning of foundation bolts and providingDWC HDPE pipe for cable entry and exit as required for the high mast considering The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c 4 Nos S.P MCB, 63Amp.DPIsolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS. | 4 | each | 1,54,138 | ₹6,16,552 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
condition.pdf
Tender Documents • 0.39 MB
BOQ_331258.xls
BOQ • 0.28 MB
viewsbd.pdf
Additional Documents • 15.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .