Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹61.6 L
EMD Value
₹1.2 L
Closing Date
27 Jul 2024, 5:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Accessories Division, Lucknow
HINDUSTAN AERONAUTICS LIMITED Accessories Division, Lucknow Post Office, Lucknow - 226 016 Uttar Pradesh, India
Air Conditioning Work for Wheels and Brakes Shop 1 and 2 of Mechanical Factory at HAL Lucknow.
8595
HAL-ADL/CWA-23AC/7
Works
Accessories Complex - Lucknow Divn - Plant Maintenance
₹0
₹1.2 L
27 Jul 2024
4 Jul 2024
4 Jul 2024
27 Jul 2024
Submission of EMD (Scan Copy & Original both, Refer Section-3). Particulars of EMD i) Demand Draft /Bankers Cheque No/Transaction No ii) Date iii) Name of Bank iv) Address of Bank v) Validity of DD/Bankers Cheque
Bid Securing Declaration Form (Refer Section-2) (Please upload in pdf)
Submission of Documents as detailed below:
Authorization Letter/Power of Attorney (IF APPLICABLE) (Please upload copy in pdf)
Proof of Valid Legal Entity. (Ref: Section -3) (Please upload copy in pdf)
PAN Copy (Ref: Section -3) (Please indicate PAN Number & upload PAN copy in pdf )
GSTIN Registraion Copy. (Ref: Section -3) (Please indicate Goods and Services Tax Registration no & upload copy in pdf)
Copy of EPFO Registration (Ref: Section -3) (Please indicate registration no. & upload copy in pdf)
Copy of ESIC Registartion (Ref: Section -3) (Please indicate registration no. & upload copy in pdf)
Proof of Annual Turnover of Last 3 Years-Profit Loss Account & Balance Sheet (Ref: Section -3). (Please upload copy in pdf)
Latest & Valid Solvency Certificate (within the period of 12 Months from the final date of submission of tender) (Ref: Section -3) (Please upload copy in pdf).
Self declaration containing details of communication (Ref: Section -3). (Please indicate e-mail ID, Name & Designation of Contact Person, Mobile No/Landline No)
Proof of experience and Proof of Work in-hand (Ref: Section -3) (Please upload in 'pdf' format)
Compliance to read and understand the Requirement & Scope of Work of the contract. (Refer Section-4 and Section-5)
Undertaking by competent authority (It is desirable to upload signed copy in pdf format)
An undertaking by the party to the effect that he is not debarred or blacklisted by any Govt. Organization /Govt. Undertaking
Undertaking from Bidder that no conditions are imposed in their price bid.
Acceptance to Complete Tender Requirement, Scope of Work, Terms & Conditions mentioned in the bidding document are properly understood and undertaking to comply with them.
Please confirm that your offer is in conformity with tender documents, wherever your offer is silent.
The rates quoted are valid and binding upon the bidder for the entire period of contract and it is certified that the rates quoted are the lowest rates as quoted in any other institution in India under same Terms and conditions as notified in present tender.
I/We give the rights to the competent authority of the Hindustan Aeronautics Limited to forfeit the Earnest Money/Security money deposit by me/us in case of breach of conditions of Tender/Contract.
I/We hereby undertake to provide services as per the directions given in the tender document/contract agreement.
I/We hereby confirm that all information/attachment/data etc. submitted with the offer are true and correct. I/We will be solely responsible for authenticity of submitted documents/data. In case at any stage, it is found that false declaration has been made suitable action as per norms can be initiated against us.
Acceptance for clause 1.24 and 1.25 of section-5 of tender document in respect of supervision of work and disposal of scrap respectively.
Acceptance to complete the work within Four months from date of work order, if awarded.
HAL-ADL/CWA-23AC/7
Description
Installation
Supply, installation, testing and commissioning of factory built floor mounted chilled water double skin type horizontal / vertical air handling unit made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with air blower section with blower suitable for static pressure as required , minimum 2 bend GSS/PVC eliminators, cooling coil section with aluminum finned copper tubes (tubes thickness not less than 0.5mm ) cooling coil of 6 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air pre filters, belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% volts, 50Hz , 3 phase AC supply suitably designed for variable frequency drive applications, drain connection, stainless steel (18G) drain pan with PUF insulation, 150mm dia. dial type pressure gauges (2 nos.) and industrial type thermometers ( 2 nos.) at the inlet and outlet of coil, The units shall incorporate with dampers for outlet, return and fresh air, fire retardant canvass connection & vibration isolation pads. Maximum face velocity across filters:2.5 m/s, Min 6R deep coil, Maximum fan outlet velocity:10 m/s.auto pressure valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities.
Supplying , laying / fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building ( with necessary clamps , vibration isolators and fitting but excluding valves , strainers , gauges etc. ) duly insulated with following closed cell elastomeric nitrile rubber of minimum 45 Kg/cu m density class ‘O’ insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect .
Meter
Meter
Supply & installation of following sizes PN16 hand lever type Aqua-seal Butterfly valve in the inlet/outlet & bypass of chilled water line with flanges, nut bolts and gasket.
Supply & installation of following sizes PN16 Balancing valve with flanges, nut bolts and gasket.
Supply & installation of following sizes Y strainer with flanges, nut bolts and gasket.
Supply & installation of following sizes 3-way modulating valve along with actuator & digital thermostat complete with flanges, nut bolts and gasket and Cu control cabling.
Supply and laying of 40 mm dia UPVC pipe with bend and socket for drain duly insulated with Nitrile insulation as per site requirement for AHU .
Supply and fixing of 4"dia Industrial Thermometer with fittings of range 0-50 deg C.
Supply and fixing of 4" dia Water Pressure Gauge with Siphon & fittings of range 0-7 Kg/cm2.
Supply & installation of 15 mm ball valve
Supply and fixing of Factory fabricated elliptical type supply air & return air GI ducting with insulated from inside with 13 mm XLPE insulation of following gauges complete with hanging arrangement, nuts, bolts, neoprene rubber gasket etc.
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal ducting complete with neoprene rubber gaskets, elbows, splitter damper, vanes, hangers, supports etc. for AHU connection and of following sheet thickness complete as required :
Supply and fixing of accoustic lining of supply air duct and plenum with 25mm thick resin bonded glass wool having density of 32 kg/m3, with 25mm X 25mm GI section of 1.25mm thick, 600mm centre to centre covered with reinforced plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface with cadmium plated nut, bolt, stick pins, CPRX compound etc complete as required and as per specifications
Supply and fixing of powder coated extruded aluminum supply air grills with aluminum volume control dampers as per specifications
Supply and fixing of powder coated extruded aluminum return air grills without volume control dampers complete as required
Supply, installation, testing and commissioning of Givolume control duct damper complete with neoprene rubber gasket, nuts, bolts, screws linkages, flanges etc as per specifications
Supplying, fixing, testing and commissioning of fire dampers in supply air ducts/ main branch and return air path as and where required.
Fabrication and installation of suitable length MS angle/channel.
Supply Installation of Canvass connection.
Supply & installation of electrical panel near to AHU within AHU room having starter to run the AHU motor along with digital metering, safeties & ON/OFF push button.
Supply and laying of PVC insulated PVC sheathed steel armoured 1.1 KV grade LTMV Aluminium/Copper conductor power cable (confirming IS: 1554 Part-I/1988) as per following sizes.
Supply and installation of suitable 8 SWG G.I. earth wire.
Dismantling of old AHU, existing duct with accessories, AHU connection pipe etc and shifting of scrap material to scrap yard
Supply, Installation, testing and commissioning of Package AC. Supply, installation, testing & commissioning of twin circuit 11 TR Air-cooled Package units including refrigerant (eco-friendly) Scroll compressor inbuilt in package AC
Supply and Installation of hard drawn copper pipe. Refrigerating hard copper piping between indoor and outdoor unit complete work like elbow socket gas welding, Nitrogen testing, suitable pipe supports etc. After laying pipelines, wall openings to be closed with POP.
Ceiling Suspended Ducted AC. Supply of ceiling mounted air-cooled ducted unit with fix speed type scroll compressor, efficient heat exchanger, low noise condenser fan, suitable for Cooling only complete in all respects with ecofriendly gas.
Refrigerant Piping
Supply, Installation of Out Door Stand. Condenser frame structurally angle of suitable size for outdoor units made of structural MS and painted with one coat of primer and two coats of synthetic enamel paint of color same as that of condenser unit.
Supply, Installation of Indoor Stand. Indoor unit stand frame structurally M.S C Channel of suitable size indoor units make of structural steel and painted with one coat of primer and two coats of synthetic enamel paint of colour same as that of indoor unit.
Supply, site unloading, Installation, Testing & Commissioning of rigid UPVC drain piping with fittings, supports as per specifications and duly insulated with 6mm thick closed cell nitrile rubber insulation etc. complete as required.
Electrical Panels: Supply & Installation of Electrical panel for AC units with following incoming and outgoing specifications: 1- Outgoing: 1 nos of 63Amp TPN MCB and 1 nos 125A MCCB Switchgear Make Wires/Cables Busbars with RYB sleeve: Copper Indicating lamp for incomer Ammeter/Voltmeter It must be manufactured and painted (color RAL7032/Siemens Grey). Authorization certificate of manufacturer must be produced by vendors at the time of drawing clearance. Drawing must be approved by HAL prior to manufacturing. Line diagram alongwith components used must be as per direction of Engineer-In-Charge.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
NoticeInvitingTender.pdf
TENDER_DOCUMENT • 0.02 MB
TenderDocument.pdf
TENDER_DOCUMENT • 0.16 MB
Technicalbid.xlsm
TENDER_DOCUMENT • 0.01 MB
PriceBid.xlsm
TENDER_DOCUMENT • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .