Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Bid | |
| 2 | L2₹15.7 L+₹90,485 (6.10%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L2 | Rejected-Finance Not Lowest Bid | |
| 3 | L3₹16.9 L+₹2.0 L (13.6%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bid | |
| 4 | L4₹17.2 L+₹2.4 L (16.1%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L4 | Rejected-Finance Not Lowest Bid | |
| 5 | L5₹17.3 L+₹2.5 L (16.8%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bid |
Tender Value
₹20.7 L
EMD Value
₹41,400
Closing Date
9 Dec 2019, 5:00 pmClosed
CWE Kirkee
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
SPECIAL REPAIR AGAINST REPLACEMENT OF BER ELECTRONIC ENERGY METER AT CME UNDER GE CME KIRKEE
2019_MES_298492_1
CWE/KKE/33 OF 2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE CME KRIKEE
Class E Cat b(i)
5 documents required · 5 mandatory
₹500
Yes
GE CME Kirkke
₹41,400
Yes
7 Jan 2020
18 Nov 2019
11 Dec 2019
18 Nov 2019
9 Dec 2019
3 Dec 2019
18 Nov 2019 - 27 Nov 2019
Amount
Removing the unserviceable existing single/three phase electromechanical energy meter of any make and capacity by disconnecting from the existing electric connections and depositing to MES store yard of AGE E/M (CME) all as directed by Engr-in-Charge
S & F tamper proof,AC Single phase static Energy meter of Accuracy class 1.0, 240V, 50Hz, with Backlit LCD display of rating 5-30A (Measures & Display KWH, V, I, KW, PF, Last month history of KWH & MD in KW) with special features like TOD, Tamper logging, Optical communication port & display in absence of Power including transparent hinge type box, Cat Ref SPPL1321120002ME03 of HPL or L & T or equivalent approved make with teak wood board of suitable size for mounting of meter incl. wiring as required for interconnection using approved cables and PVC flexible pipes. Make- L&T, HPL, Secure,Siemens as approved by GE. NOTE : Submain wiring required for shall be measured and paid separately.
S & F tamper proof,AC Three phase static Energy meter of Accuracy class 1.0, 3x240V, 50Hz, with Backlit LCD display of rating 10-60A (Measures & Display KWH, V, I, KW,PF Hz, Last month history of KWH & MD in KW) with special features like TOD, Tamper logging, Optical communication port & display in absence of Power including transparent hinge type box, Cat Ref TPPB152113000ME01 of HPL or L & T or equivalent approved make with teak wood block of suitable size for mounting of meter incl. wiring as required for interconnection using approved cables and PVC flexible pipes. NOTE : Submain wiring required for shall be measured and paid separately.
M & L for submain wiring with two runs of 6 sqmm single core multi stranded PVC insulated and unsheathed copper conductor of grade 1100 volt FRLSH cable (red for phase & black for neutral) & 4 sqmm copper conductor cable PVC unsheathed green coloured for earthing in and including PVC conduit with complete accessories duly connected with earth duly complete incl taking down old unserviceable all as specified & as directed. NOTE: 1) Two run of cables, one run of PVC conduit and one run of continuous earth wire will be measured as one length of submain wiring. 2) Makes of cable : Finolex / Polycab / Havells / Indo-Asian / Anchor / HPL
M & L for submain wiring with two runs of 4 Sqmm single core multi stranded PVC insulated and unsheathed copper conductor of grade 1100 volt FRLSH cable ( red for phase & black for neutral ) & 2.5 Sqmm copper conductor cable PVC unsheathed green coloured for earthing in and including PVC conduit with complete accessories duly connected with earth duly complete incl taking down old unserviceable all as specified & as directed. NOTE: 1) Two runs of cables, one run of PVC conduit and one run of continuous earth wire will be measured as one length of submain wiring 2) Makes of cable : Finolex / Polycab / Havells / Indo-Asian / Anchor / HPL
M & L for submain wiring with four runs of 6 Sqmm single core multi stranded PVC insulated and unsheathed (FRLSH) insulated copper conductor of grade 1100 volt ( red for phase & black for neutral ) & two runs of 4 Sqmm copper conductor cable PVC unsheathed green coloured for earthing in and including PVC conduit with complete accessories duly connected with earth duly incl taking down old unserviceable complete all as specified & as directed. Note :1) Four runs of cable,two runs of earth wire and one run of PVC conduit together shall be considered as one length 2) Makes of cable : Finolex / Polycab / Havells / Indo-Asian / Anchor / HPL
M/S. Niksun Electro-Infra Private Limited
Pritam Electro Mechanical Services
Rama Electricals
Tulsani Associates
SHREE VAIBHAV ELECTRICALS
MAYUR ELECTRIC SERVICES
Om Construction
metro electrical services
K D Electricals
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .