Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹47.5 LAdmitted-Finance | -4.25% | ₹47.5 L | L1 | Admitted-Finance |
| 2 | L2₹48.9 LAdmitted-Finance | -1.50% | ₹48.9 L | L2 | Admitted-Finance |
| 3 | L3₹49.1 LAdmitted-Finance | -1.10% | ₹49.1 L | L3 | Admitted-Finance |
Tender Value
₹50.4 L
EMD Value
₹1.1 L
Closing Date
1 Apr 2026, 3:00 pmClosed
SE
Agra
Construction of 03 Nos Computer Lab at Kasturba Gandhi Balika Vidhyalaya in Different Block District Kasganj (Package-4)
2026_UPHDB_1126164_1
646/UPHDB/D-3/09 Date 09.03.2026
Open Tender
Civil Works - Buildings
Percentage
120 days
Kasganj
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
Executive Engineer
₹1.1 L
15 Apr 2026
17 Mar 2026
2 Apr 2026
17 Mar 2026
1 Apr 2026
17 Mar 2026
Earth work in excavation in trenches for foundations and pipes ables etc in ordinary soil (loan clay or sand) including lift upto 1.5 m, lead upto 50 m and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer- in- charge with in a lead of 50m .(Including royalty). DSR 2.8.1
Filling of good earth for filling low land pocket from 8 km distence including loading unloading & ramming watering proper compaction with 20 cm layer not exceeding work executed as per direction of engineer-in-charge complete. DSR 2.25a
Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. DSR 4.1.8
Sand filling in plinth including supply of necessary quantity of sand from a distance not excluding 8km from the site of work and including watering dressing etc. rate to include cost of all materials, labour and T&P etc.required for proper completion of the work. DSR 2.27
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 5 liters/sqm (6) Treatment of soil apron along external perimeter 5 liter per SQM. DSR 2.35.3.1
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) Upto plinth level R.C.C. work in Footing
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) Upto plinth level R.C.C. work in Plinth Beam
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) Upto plinth level R.C.C. work in Columns
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) Above plinth to floor-V lvl R.C.C. work in Columns
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) Above plinth to floor-V lvl R.C.C. work in Lintel. DSR 5.3
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) Above plinth to floor-V lvl R.C.C. work in Beam. DSR 5.3
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) Above plinth to floor-V lvl R.C.C. work in Slab. DSR 5.3
Centering and shuttering including strutting, propping etc. And removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete. DSR 5.9.1
Centering and shuttering including strutting, propping etc. And removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick. DSR 5.9.21
Centering and shuttering including strutting, propping etc. And removal of form for all heights : Edges of slabs and breaks in floors and walls Under 20 cm wide. DSR 5.9.16.1
Centering and shuttering including strutting, propping etc. And removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts. DSR 5.9.6
Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in anover all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. DSR 5.22.6
First class brick work in 1:6 cement and coarse sand of 2.25 fineness modulus) mortar using class-150 brick work in foundation & plinth including supply of all materials, labour and T & P etc reqiored for proper completion of the work. DSR 6.1.2
First class brick work in 1:6 cement and coarse sand of 2.25 fineness modulus) mortar using class-150 brick work in above plinth level up to floor five level including supply of all materials, labour and T & P etc reqiored for proper completion of the work. DSR 6.4.2
First class brick work in 1:4 cement and coarse sand of 2.25 fineness modulus) mortar using class-150 brick work in above plinth level up to floor five level including supply of all materials, labour and T & P etc reqiored for proper completion of the work. DSR 6.4.1
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Single leaf. DSR 9.20.1
Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. Hold fast for chaukhats of doors/windows. DSR 10.1
Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. Door / windows & Staircase grill. DSR 9.48.1
Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. Z-Section windows (Openable) DSR 10.25.2
Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size. DSR 10.13.1
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes. DSR 10.30.1
Fixing of M.S. Chaukhats Door chaukhats. (MR)
15 mm thick plaster in 1:4 cement & course sand on outer wall below Ground level & inner wall below plinth level in 15 cm width. DSR 13.5.1
12 mm cement plaster in single coat on FAIR side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 C. sand. DSR 13.4.2
15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 C. sand. DSR 13.5.2
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. DSR-5.30
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. DSR-5.30
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN] DSR 11.41.2
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN] DSR 11.47.2
Steel Painting:Applying priming coat: (a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. DSR 13.62.1
Steel Painting:Applying priming coat: (b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. DSR 13.62.1
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) DSR -13.47.1
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR 13.80
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including water thinnable priming coat with cement primer. DSR 13.41.1
Providing & fixing stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm (MR)
P/Fixing stainless steel tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as / IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. 250 mm x 10mm (MR)
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. DSR 22.7
Providing and laying damp-proof course 40mm thick with cementconcrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 12.5mm nominal size derived fromnatural sources) DSR 4.10
Providing & applying a coat of residual petroleum bitumen of grade ofVG-10 of approvedquality using 1.7kg per square metre on damp proofcourse after cleaning the surface with brushes and finally with apieceof cloth lightly soaked in kerosene oil. DSR 4.13
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) DSR 4.1.3
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C (DSR E&M 2022 - 1.10.3)
Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X1.5 sqmm + 1x1.5 sqmm earth wire (DSR E&M 2022 - 1.14.1)
Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X2.5 sqmm + 1x 2.5 sqmm earth wire (DSR E&M 2022 - 1.14.2)
Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X4.0 sqmm + 1x 4.0 sqmm earth wire (DSR E&M 2022 - 1.14.3)
Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 20mm (DSR E&M 2022 - 1.21.1)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. TV antenna socket outlet (DSR E&M 2022 - 1.24.7)
Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (DSR E&M 2022 - 1.25)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (DSR E&M 2022 - 1.26)
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 module(75mm X 75 mm ) (DSR E&M 2022 - 1.27.1)
Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/woodedn block including connectionetc. As required. (DSR E&M 2022 - 1.33)
Supplying and fixing brass batten/angle holder including connectionetc. as required. (DSR E&M 2022 - 1.34)
Instalation,testing & commissioning of wall bracket/ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required. (DSR E&M 2022 - 1.35)
Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required. (DSR E&M 2022 - 1.41)
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. (DSR E&M 2022 - 1.49)
Installation of exhaust fan in the existing opening, including making good the damage, connections, testing, commissioning etc. as required. upto 450 mm sweep. (DSR E&M 2022 - 1.50.1)
Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes. (DSR E&M 2022 - 1.51)
Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, `C` curve including connections, painting etc. as required. (DSR E&M 2022 - 1.57)
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Disect Current(BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6, Air delivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (DSR E&M 2022 - 19.1)
Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB / Isolators). 12 way, Double door (DSR E&M 2022 - 2.3)
Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. Single Pole. (DSR E&M 2022 - 2.10.1)
Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. Double Pole. (DSR E&M 2022 - 2.10.3)
Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required. (DSR E&M 2022 - 2.11)
Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 10 sqmm 2 core. (MR)
Supply & fixing of 7/9 W LED BULB complete in all respect. (MR)
Supply and fixing of LED Tube Light with batten suitable for up to 1X20 watt LED tube light complete including tube etc. on surface complete in all respect. (MR)
Supply & fixing ofrecess/Surface/Pendent mounting round 10 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects. Cat. AAA (MR)
Supply anf fixing of 36 watt to 46 watt indoor recess mounting LED square fitting for armstorng ceiling having Powder Coated die cast aluminium housing body with extended heat sink & diffuser of special polycarbonate material and driver set complete in all respect. (MR)
Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screwed, one loc at the conrners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. (MR)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 110mm diameter (DSR 12.41.2)
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. (DSR 12.22)
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm (DSR 12.43.2)
Supply and fixing of ABC type (4 kg.) ISI Marked 1131 (MR)
Supply and fixing of CO2 gas type (4.5 kg.) ISI Marked (MR)
Supply and fixing of self glow type exit signage (MR)
23-Port Network Switch (Gigabit) (MR)
Cat6 LAN Cable (305m box) (MR)
RJ45 Connectors (Pack of 100) (MR)
I/O Ports with Faceplates & Boxes (MR)
Patch Panel (23 Port) (MR)
Cable Ducts, Ties & Clips (MR)
Switch Rack / Wall Mount Rack (MR)
Labor: Cabling & Setup (MR)
Testing & Configuration (MR)
stage.html
html • 0.03 MB
technical_2099895.pdf
techsummary_2099895.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.33 MB
P4Tech50kas.pdf
Tender Documents • 12.61 MB
BOQ_2099895.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].