| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹8.2 L+₹1.3 L (18.9%)Rejected-Finance 41 A COLONELGANJ CANTT FATEHGARH DISTT FARRUKHABAD UP 209601 | FATEHGARH | FARRUKHABAD | UP | 209601 | L2 | Rejected-Finance being not lowest |
Tender Value
₹9.8 L
EMD Value
₹20,000
Closing Date
23 Dec 2023, 6:00 pmClosed
AGE(I) Fatehgarh
Fatehgarh
REPAIR/MAINT AND REPLACEMENT OF GI PIPE LINES, VALVE PITS AND CERTAIN MISC WORKS AT FATEHGARH CANTT.
2023_MES_628814_1
AGE(I)/FAT/ET-37 OF 2023-2024
Open Tender
Miscellaneous Works
Item Rate
270 days
AGE(I) Fatehgarh
PLEASE REFER TO TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
AGE(I) Fatehgarh
₹20,000
Yes
9 Feb 2024
18 Nov 2023
30 Dec 2023
18 Nov 2023
23 Dec 2023
5 Dec 2023
18 Nov 2023 - 4 Dec 2023
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth and getting out for taking up and laying of pipe in soft/loose soil all complete as specified & as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc 25 Cms in soft/loose soil all as specified and directed.
Removing excavated material (soil) n. exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point as specified and directed.
Taking up or down 15 mm bore GI tubing and connections from trenches/floor /walls /Ceiling of following sizes and grade, including cleaning for re-fixing or removal to store, complete all as specified and directed.
Ditto as above but for size 20 mm bore…ditto as above…
Ditto as above but for size 25 mm bore…ditto as above…
Ditto as above but for size 40 mm bore…ditto as above…
Ditto as above but for size 50 mm bore…ditto as above…
Ditto as above but for size 80 mm bore…ditto as above…
Supply & Fixing inreplacement 15 mm bore galvanized steel tubing , medium grade with all fittings and fixed to walls , ceilings or laid in floors, trenches complete as per IS 1239 Part-II all as specified and directed
Supply & Fixing inreplacement 20 mm bore galvanized steel tubing , medium grade with all fittings and fixed to walls , ceilings or laid in floors, trenches complete as per IS 1239 Part-II all as specified and directed
Supply & Fixing inreplacement 25 mm bore galvanized steel tubing , medium grade with all fittings and fixed to walls , ceilings or laid in floors, trenches complete as per IS 1239 Part-II all as specified and directed
Supply & Fixing inreplacement 40 mm bore galvanized steel tubing , medium grade with all fittings and fixed to walls , ceilings or laid in floors, trenches complete as per IS 1239 Part-II all as specified and directed
Supply & Fixing inreplacement 50 mm bore galvanized steel tubing , medium grade with all fittings and fixed to walls , ceilings or laid in floors, trenches complete as per IS 1239 Part-II all as specified and directed
Supply & Fixing inreplacement 80 mm bore galvanized steel tubing , medium grade with all fittings and fixed to walls , ceilings or laid in floors, trenches complete as per IS 1239 Part-II all as specified and directed
Re-fixing only 15 mm bore galvanized steel tubing , medium grade with all fittings in trenches,ceilings,walls, floors complete all as specified and directed.
Re-fixing only 20 mm bore galvanized steel tubing , medium grade with all fittings in trenches,ceilings,walls, floors complete all as specified and directed.
Re-fixing only 25 mm bore galvanized steel tubing , medium grade with all fittings in trenches,ceilings,walls, floors complete all as specified and directed.
Re-fixing only 40 mm bore galvanized steel tubing , medium grade with all fittings in trenches,ceilings,walls, floors complete all as specified and directed.
Re-fixing only 50 mm bore galvanized steel tubing , medium grade with all fittings in trenches,ceilings,walls, floors complete all as specified and directed.
Re-fixing only 80 mm bore galvanized steel tubing , medium grade with all fittings in trenches,ceilings,walls, floors complete all as specified and directed.
M&L in replacement of 80 mm dia sluice valve class PN-1.6 heavy duty flanged ends drilled , ISI-marked confirming to IS:14846 suitable for following bore pipe, wheel oprated (Handle) with high tensile stainless steel spindle, including nuts, bolts and jointing with jointing materials etc. complete including taking out old existing unservicable sluice valve incl. making arrangement for safe working all as specified and directed
M&L in replacement of 100 mm dia sluice valve class PN-1.6 heavy duty flanged ends drilled , ISI-marked confirming to IS:14846 suitable for following bore pipe, wheel oprated (Handle) with high tensile stainless steel spindle, including nuts, bolts and jointing with jointing materials etc. complete including taking out old existing unservicable sluice valve incl. making arrangement for safe working all as specified and directed
M&L in replacement of 150 mm dia sluice valve class PN-1.6 heavy duty flanged ends drilled , ISI-marked confirming to IS:14846 suitable for following bore pipe, wheel oprated (Handle) with high tensile stainless steel spindle, including nuts, bolts and jointing with jointing materials etc. complete including taking out old existing unservicable sluice valve incl. making arrangement for safe working all as specified and directed
S & F in replacement of valve pit cover for chamber of size 1200x1200x 1200 mm made out of 3mm thick mild steel plain sheet and frame work of angle iron of size 40x40x6 mm thick incl providing 4 Nos mild steel butt hinges 100 mm size and MS handle of flat iron fabricated and two coat of synthetic enamel paint over a coat of red oxide primer and including preparation of steel surfaces complete all as specified and directed
Ditto as above but for size 900mmX900 mm….ditto….
Ditto as above but for size 600mmX 600mm
Supply & fixing in replacement 15 mm dia of Gun-metal , globe or gate Valves, with iron wheel head , screwed both ends for iron pipe and fixed complete all as specified & as directed
Ditto as above but for 20 mm dia….ditto as above….
Ditto as above but for size 25 mm bore….ditto as above….
Ditto as above but for size 40 mm bore ….ditto as above….
Ditto as above but for size 50 mm bore….ditto as above….
M&L in replacement of 80 mm dia old U/S Sluice valve spindle with assembly of stainless steel suitable for following size of sluice valves including nut, bolt and washers packing, new lead , gland, dori etc required for making leak proof,complete all as specified ansd directed
Ditto as above but for size 100 mm dia ….ditto as above….
Ditto as above but for size 150 mm dia….ditto as above….
M & L for GI flanges jointing with 2 Nos GI flanges including 04 Nos nuts, bolts, washer, rubber or lather gasket incluiding screwing and fixing complete all as specified and as directed of size.80 mm bore
M & L for GI flanges jointing with 2 Nos GI flanges including 04 Nos nuts, bolts, washer, rubber or lather gasket incluiding screwing and fixing complete all as specified and as directed of size.100 mm bore
M & L for GI flanges jointing with 2 Nos GI flanges including 04 Nos nuts, bolts, washer, rubber or lather gasket incluiding screwing and fixing complete all as specified and as directed of size 150 mm bore
S & F for drilling hole in existing CI/GI water main (in any position) and making arrangement for tapping water connection for 15 /20/25 mm with and including mild steel clamp of size 50 x 6 mm in existing CI/DI/GI pipeline any size,dia. with necessary nut bolts,GI tubing up to 1.5 metre long with required fittings and necessary welding works ,gasket etc complete all as specified and directed
M & L for construction of brick masonry valve pits with sub-class 'B' brick built in cement mortar (1:6) of size 1200 x 1200 x 1200 mm (internal dimension) with one brick walling and 190 cm x190 cm x 10 cm base foudation with PCC 1:3:6 rendering cement plastering 10 mm thick with cement mortar (1:4) on internal & exposed surfaces, including MS cover of size 01 mtr x 01 mtr made out from 3 mm thick MS sheet including 40 x 40 x 5 mm angle iron framing on MS cover as well as on top wall of the valve pit & painting of the MS cover with two coat of synthetic enamel paint over a coat of red oxide primer including necessary earth work & demolitioln of the existing old valve pit all as specified and as directed.
M & L for construction of brick masonry valve pits with sub-class 'B' brick built in cement mortar (1:6) of size 900 x 900 x 900 mm (internal dimension) with one brick walling and 150 cm x150 cm x 10 cm base foudation with PCC 1:3:6 rendering cement plastering 10 mm thick with cement mortar (1:4) on internal & exposed surfaces, including MS cover of size 01 mtr x 01 mtr made out from 3 mm thick MS sheet including 40 x 40 x 5 mm angle iron framing on MS cover as well as on top wall of the valve pit & painting of the MS cover with two coat of synthetic enamel paint over a coat of red oxide primer including necessary earth work & demolitioln of the existing old valve pit all as specified and as directed.
M & L for construction of valve pits with sub-class 'B' brick built in cement mortar (1:6) of size 600 x 600 x 600 mm (internal dimension) with one brick walling and 120 cm x120 cm x 10 cm base foudation with PCC 1:3:6 rendering cement plastering 10 mm thick with cement mortar (1:4) on internal & exposed surfaces, including MS cover of size 75 x 75 cm made out from 3 mm thick MS sheet including 30 x 30 x 5 mm angle iron framing on MS cover as well as on top wall of the valve pit & painting of the MS cover with two coat of synthetic enamel paint over a coat of red oxide primer including necessary earth work & demolitioln of the existing old valve all as specified and as directed.
S & F in replacement of cast iron air release valves with single air outlets of 25 mm dia bore fixed on 150 mm dia (confirming to IS-14845) pipe line complete all as specified & as directed.
S & F in replacement of cast iron air release valves flanged end with two air outlets of 100 mm dia bore fixed on 150 mm dia (confirming to IS-14845) pipe line complete all as specified & as directed.
S & F in replacement of cast iron air release valves flanged end with two air outlets of 150 mm dia bore fixed on 150 mm dia (confirming to IS-14845) pipe line complete all as specified & as directed.
M & L in replacement of non-return valves (Reflex) of 100 mm nominal (confirming to IS-5312) dia complete all as specified and as directed
M & L in replacement of non-return valves(Reflex) of 150 mm nominal dia (confirming to IS-5312) complete all as specified and as directed
M&L for Leakage detection in GI water mains 15/20/25 mm bore and carrying out necessary repairs including cutting, reducing for insertion of GI fittings such as Tee, Bends, reducer, elbow, nipple, union etc incl welding, all as required at site including Excavation, returning, filling in and removal of excess soil complete all as directed
M&L for Leakage detection in GI water mains 40/50 mm bore and carrying out necessary repairs including cutting, reducing for insertion of GI fittings such as Tee, Bends, reducer, elbow, nipple, union etc including welding, all as required at site including Excavation, returning, filling in and removal of excess soil complete all as directed
M&L for Leakage detection in GI water mains 80 mm bore and carrying out necessary repairs including cutting, reducing for insertion of GI fittings such as Tee, Bends, reducer, elbow, nipple, union etc including welding, all as required at site including Excavation, returning, filling in and removal of excess soil complete all as directed
M & L for MS Clamp made out of 32 x 6 mm strip bend to shape, fixed on wall with 02 Nos Y shape steel fastner of suitable size for securing GI pipe 50/40 mm dia rising mains fixed on various buildings including scafolding complete all as specified and as directed.
Testing of Raw and treated water of capacity 50 KLD STP for the following parameters BOD,COD, Focal Coliform (FC) testing will be carried out from Govt authorised agencies/Lab , the sample of Raw and treated water obtain from STP in sealed plastic containers Note:- Transportation charges of water samples for testing shall be borne by the contactor
Material & labour for water sample colletcted from all pump houses of the station for testing from HBTI Kanpur/Jal Nigam board, Agra or authorised agencies for testing of water for chemical and bacteria logical tests as per IS:10500. Sample of water obtained from pump houses in sealed plastic containesr of 5 ltrs capacity.Transportation charge of water samples for testing shall be borne by the contractor.The following tests are required at each pump houses...... (i) pH test (ii) Total Dissolved Solids (TDS) test (iii) Coliform test (Microbiological test) (iv) Total hardness test (v) Calcium hardness test (vi) Fluoride test and (vii) Iron test
MS. BK BROTHERS AND CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .