Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC ASADUNA TODRAN TEHSIL BAHADURGARH DISTRICT JHAJJAR 124505 HARYANA | BAHADURGARH | JHAJJAR | HARYANA | 124505 | ₹1.6 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹1.8 CrRejected-Finance VPO KILO DORPANA DISTRICT ROHTAK 124401 HARYANA | ROHTAK | ROHTAK | HARYANA | 124401 | ₹1.8 Cr | L2 | Rejected-Finance Higher Bidder |
| 3 | L3₹2.1 CrRejected-Finance 858 SECTOR 23 127021 | BHIWANI | HARYANA | 127021 | ₹2.1 Cr | L3 | Rejected-Finance Higher Bidder |
| 4 | L4₹2.2 CrRejected-Finance | ₹2.2 Cr | L4 | Rejected-Finance Higher Bidder |
| Sl No | Description | Qty | Unit | Jitender Contractor L1 | virender contractor L2 | M/S SHREE BALAJI BUILDERS L3 | BAL KRISHAN CONTRACTOR L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | NS ITEM: Credit of old steel bars (scrap) | 2,433.44 | Kg. | 30 -₹73,003 | 30 -₹73,003 | 30 -₹73,003 | 30 -₹73,003 |
| 2.00 | NS ITEM: Credit of RCC pipe class NP3 pipe: 600 MM outer Dia Removed Pipe of Diversion | 40 | Metre | 1,798 -₹71,920 | 1,798 -₹71,920 | 1,798 -₹71,920 | 1,798 -₹71,920 |
| 3.00 | NS ITEM: RCC pipe class NP3 pipe : 1200 MM outer Dia | 5 | Metre | 4,343 -₹21,715 | 4,343 -₹21,715 | 4,343 -₹21,715 | 4,343 -₹21,715 |
| 4.00 | NS ITEM: Credit of Old NP3 1000mm Pipe | 5 | Metre | 3,575 -₹17,875 | 3,575 -₹17,875 | 3,575 -₹17,875 | 3,575 -₹17,875 |
| 5.00 | NS ITEM: Credit of Old NP3 900mm Pipe | 15 | Metre | 2,889 -₹43,335 | 2,889 -₹43,335 | 2,889 -₹43,335 | 2,889 -₹43,335 |
| 6.00 | NS ITEM: Credit of RCC pipe class NP3 pipe : 1200 MM outer Dia | 56.58 | Metre | 4,761 -₹2,69,377 | 4,761 -₹2,69,377 | 4,761 -₹2,69,377 | 4,761 -₹2,69,377 |
Tender Value
₹2.0 Cr
EMD Value
₹3.9 L
Closing Date
23 Mar 2026, 6:00 pmClosed
ISHAN SINGH SIWACH
W.S. Divn., B/Garh
Replacement of pipe culvert into RCC Box Culvert on Sarai Aurangabad kassar Link Drain at RD 716,2300,6460,7250,27700 and 28960
2026_HRY_507733_1
20263161DEB8 626A 4471 9D6D 1D4EA08D7AD91616IRR
Open Tender
Civil Works
120 days
KASSAR LOWA KHURD NUNA MAJRA Zardakpur MANDOTH
Replacement of pipe culvert into RCC Box Culvert on Sarai Aurangabad kassar Link Drain at RD 716,2300,6460,7250,27700 and 28960
3 documents required · 3 mandatory
₹15,000
₹3.9 L
Yes
Bahadurgarh
3 Apr 2026
12 Mar 2026
24 Mar 2026
12 Mar 2026
23 Mar 2026
12 Mar 2026
16 Mar 2026
NS ITEM: Credit of old steel bars (scrap)
NS ITEM: Credit of RCC pipe class NP3 pipe: 600 MM outer Dia Removed Pipe of Diversion
NS ITEM: RCC pipe class NP3 pipe : 1200 MM outer Dia
NS ITEM: Credit of Old NP3 1000mm Pipe
NS ITEM: Credit of Old NP3 900mm Pipe
NS ITEM: Credit of RCC pipe class NP3 pipe : 1200 MM outer Dia
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
HSR Item [11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) [Through Rate]
HSR Item [11.57]Providing and laying average 6mm thick POP Coating on walls, Ceiling, beams and lintels etc. complete in all respects as approved by the Engineer-In-Charge. [Through Rate]
HSR Item [11.95.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) [Through Rate]
HSR Item [17.13]Granular Sub-Base (Mix in place) Construction of granular sub-base by providing Material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per technical clause 401 of MORT&H technical specifications [Through Rate]
HSR Item [17.69.2]Interlocking Concrete Block Pavement 2. Providing and Laying 80 mm thick ISI marked Interlocking Paver Blocks conforming to IS 15658:2006/IRC SP 63: 2004 of all shapes and colours in design mix cement M 40 over the bed of 30 mm thick fine sand complete in all respect. [Through Rate]
HSR Item [21.95.10]Providing lowering cutting jointing and testing RCC pipe class NP3 as per IS-458-2003 with spigot and socketed joints manufactured with ISI marked sulphate resistance cement as per ISI 12330 with rubber rings ISI marked antiternmite as required at site in to trenches for all depths and laying out the same to correct alignment gradients and levels including dressing and trimming and cutting of concrete beds and side of trenches, if required jointing with rubber rings in trenches and jointing with 1:3/2 cement sand mortar and with end dowels filled with 1:3/2 cement sand mortar and finishing the joints at an angle of 45 degree with faces of spigot of socket joints cutting and finishing the cut surface to a uniform finish etc. as fully described in item No. 21.38, item 21.44, item 21.45, and item 21.46 including cartage loading and unloading complete in all respects. the internal diametric of the sewer being: 10. 1200 mm [Through Rate]
HSR Item [27.10.1.2]RCC Grade M25 1.2. With Batching Plant, Transit Mixer and Concrete Pump [Through Rate]
HSR Item [27.13]Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and MoRTandH Specifications 1600 & 2200. [Through Rate]
HSR Item [27.15]Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing force. Complete as per drawing and MoRTandH Specifications 2706 & 2200. [Through Rate]
HSR Item [27.28.1.1]Using Batching Plant, Transit Mixer and Concrete Pump 1.1. For formwork and staging add the following: For solid slab super-structure, 20-30 per cent of labour, material and machinery cost Height up to 5m [Through Rate]
HSR Item [27.44.1]Drainage Spouts complete as per drawing no. SD/205 and MoRTandH MoRTandH specification clause 2705 with 6 meter long GI 100 mm dia drainage GI light grade pipe (For Bridges) 1. For fabrication [Through Rate]
HSR Item [27.5]Plain/Re-inforced cement concrete in sub-structure complete as per drawing and MoRTandH specifications 1500,1700 and 2200. PCC Grade M15 (with concrete Mixer) Height up to 5m [Through Rate]
HSR Item [27.51.3]Filler joint 3. Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement up to 20 mm, covered with sealant complete as per drawing and MoRT&H specifications. [Through Rate]
HSR Item [27.7.1.2]PCC Grade M25 1.2. With Batching Plant, Transit Mixer and Concrete Pump [Through Rate]
HSR Item [34.19.1]Hazard Marker sign board 300x900mm rectangular as per IRC 67- 2012 with retro reflective Sheeting as per ASTM D 4956 09 and IRC 67 2012, fixed over 4mm thick Aluminium Composite Material (ACM) sheeting having skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 firmly fixed to ground including foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORTandH specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting and a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67- 2012. 1. Using retro reflective Sheeting Class C as per IRC 67 2012 [Through Rate]
HSR Item [34.4.1]Cautionary sign board 900x900x900mm triangular as per IRC 67- 2012 with retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORTandH specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting and a certified copy of test reports including three year outdoor weathering test report for sheeting tested in India condition from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 1. Using retro reflective Sheeting Class C as per IRC 67 2012 [Through Rate]
HSR Item [4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil [Through Rate]
HSR Item [4.16.1.5]Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1.5. Pipes, cables etc, exceeding 900 mm dia but not exceeding 1200 mm dia. [Through Rate]
HSR Item [4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. [Through Rate]
HSR Item [4.33]Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. [Through Rate]
HSR Item [5.23.2]Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 2. Nominal concrete 1:2:4 or leaner mix (i/c equivalent design mix) [Through Rate]
HSR Item [5.25]Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. [Through Rate]
HSR Item [5.53.1]Removing hume pipes-NP 2/NP 3/NP 4 including excavation and taking out the pipes manually/ by mechanical means and stacking the pipes within standard lead as per direction of Engineer-in-charge 1. up to 600 mm dia [Through Rate]
HSR Item [5.53.2]Removing hume pipes-NP 2/NP 3/NP 4 including excavation and taking out the pipes manually/ by mechanical means and stacking the pipes within standard lead as per direction of Engineer-in-charge 2. above 600 mm dia [Through Rate]
HSR Item [7.21.3]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 3. Cement mortar 1:3 (1 cement : 3 coarse sand) [Through Rate]
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.70 MB
BOQ_586497.xls
BOQ • 0.39 MB
AD0154865.pdf
Additional Documents • 0.44 MB
Download all tender documents and submit your bid