Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC WARD NO 13 NEW SURATGARH | SURATGARH | ₹6.6 L Quoted ₹6.8 L | L1 | Accepted-AOC VALID |
| 2 | L2₹10.7 L+₹3.9 L (57.0%)Rejected-Finance | ₹10.7 L+₹3.9 L (57.0%) | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹10.8 L+₹4.0 L (58.4%)Rejected-Finance RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | ₹10.8 L+₹4.0 L (58.4%) | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | L4₹12.0 L+₹5.1 L (75.1%)Rejected-Finance 140 DEORISINGHPURA RANIPUR JHANSI JHANSI UTTAR PRADESH 284205 UDYAM UP 39 0007853 | JHANSI | UTTAR PRADESH | 284205 | ₹12.0 L+₹5.1 L (75.1%) | L4 | Rejected-Finance NOT BEING LOWEST |
| 5 | L5₹14.7 L+₹7.9 L (115.7%)Rejected-Finance R G BARUAH ROAD NEAR SHIV MANDIR GUWAHATI AIRPORT GUWAHATI 781015 | KAMRUP METRO | ASSAM | 781015 | ₹14.7 L+₹7.9 L (115.7%) | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
30 Jul 2021, 6:00 pmClosed
GE AF SURATGARH
GE AF SURATGARH
COMPREHENSIVE REPAIR MAINT OF SEWAGE TREATMENT PLANT RO PLANT AND CERTAIN EM WORKS AT AF STN SURATGARH
2021_MES_443411_2
8862/E8
Open Tender
Civil Works
Item Rate
334 days
GE AF SURATGARH
AS PER TENDER DOCUMENT
10 documents required · 10 mandatory
₹500
Yes
GE AF SURATGARH
₹20,000
Yes
28 Oct 2021
6 Jul 2021
2 Aug 2021
6 Jul 2021
30 Jul 2021
14 Jul 2021
Amount
BOQ (COMPREHENSIVE REPAIR/MAINT OF SEWAGE TREATMENT PLANT, RO PLANT AND CERTAIN E/M WORKS AT AF STN SURATGARH)
Dewatering the left over water from existing old sewage water storage tank of existing storage capacity , having round shape bottom plan size 5 meter and depth 9 meter, desalting, sludge, silt, all accumulate material with mud and sewage sludge from the bottom and sides and removing and cleaning, desalting, sludge, silt, all accumulate material with mud and sewage sludge from the bottom and sides from the outer perimeter of tank and depositing/spreading where directed by Engr-in-charge including preparation of surface by wire brushing and washing the surface with 2% potassium permanganate solution for disinfection and applying one coat of white wash including removal of roots and uprooting of grass etc. all around up to 3 meter from plinth of old sewage tank, and removing mud and sludge out from area of sewage treatment plant ,complete all as specified and directed by Engr-in-charge.
Dewatering the left over water from existing still chamber and per screen chamber of existing storage capacity , having size 3x1.5 meter and depth 2 meter, desalting, sludge, silt, all accumulate material with mud and sewage sludge from the bottom and sides and removing and cleaning, desalting, sludge, silt, all accumulate material with mud and sewage sludge from the bottom and sides from the outer perimeter of tank and depositing/spreading where directed by Engr-in-charge including preparation of surface by wire brushing and washing the surface with 2% potassium permanganate solution for disinfection and applying one coat of white wash including removal of roots and uprooting of grass etc. all around up to 3 meter from plinth of still chamber and per screen chamber and removing mud and sludge out from area of sewage treatment plant ,complete all as specified and directed by Engr-in-charge.
Dewatering the left over water from existing sludge holding tank of existing storage capacity , having size 6x8 meter and depth 5 meter, desalting, sludge, silt, all accumulate material with mud and sewage sludge from the bottom and sides and removing and cleaning, desalting, sludge, silt, all accumulate material with mud and sewage sludge from the bottom and sides from the outer perimeter of tank and depositing/spreading where directed by Engr-in-charge including preparation of surface by wire brushing and washing the surface with 2% potassium permanganate solution for disinfection and applying one coat of white wash including removal of roots and uprooting of grass etc. all around up to 3 meter from plinth of sludge holding tank,and removing mud and sludge out from area of sewage treatment plant complete all as specified and directed by Engr-in-charge.
Dewatering the left over water from existing chlorine content tank of existing storage capacity , having size 6x8 meter and depth 5 meter, desalting, sludge, silt, all accumulate material with mud and sewage sludge from the bottom and sides and removing and cleaning, desalting, sludge, silt, all accumulate material with mud and sewage sludge from the bottom and sides from the outer perimeter of tank and depositing/spreading where directed by Engr-in-charge including preparation of surface by wire brushing and washing the surface with 2% potassium permanganate solution for disinfection and applying one coat of white wash including removal of roots and uprooting of grass etc. all around up to 3 meter from plinth of chlorine content tank , and removing mud and sludge out from area of sewage treatment plant complete all as specified and directed by Engr-in-charge.
Dewatering the left over water from existing equalize tank of existing storage capacity , having size 3x5 meter and depth 7metre, desalting, sludge, silt, all accumulate material with mud and sewage sludge from the bottom and sides and removing and cleaning, desalting, sludge, silt, all accumulate material with mud and sewage sludge from the bottom and sides from the outer perimeter of tank and depositing/spreading where directed by Engr-in-charge including preparation of surface by wire brushing and washing the surface with 2% potassium permanganate solution for disinfection and applying one coat of white wash including removal of roots and uprooting of grass etc. all around upto 3 metre from plinth of equalize tank, and removing mud and sludge out from area of sewage treatment plant complete all as specified and directed by Engr-in-charge.
Taking up or down steel tubing and connections of size 100 mm bore with connected valves, including internal cleaning of pipe and connected valves and removing from sludge and mud deposited inside the pipe and cleaning pipe internally with clean water pressure and refixing of pipes with suitable nuts and bolts as existing location complete all as specified and directed.
Taking up or down steel tubing and connections of size 150 mm bore with connected valves, including internal cleaning of pipe and connected valves and removing from sludge and mud deposited inside the pipe and cleaning pipe internally with clean water pressure and refixing of pipes with suitable nuts and bolts as existing location complete all as specified and directed.
Taking up or down steel tubing and connections of size 40/50/75 mm bore with connected valves including internal cleaning of pipe and connected valves removing from sludge and mud deposited inside the pipe and cleaning pipe internally with clean water pressure and refixing of pipes with suitable nuts and bolts as existing location complete all as specified and directed.
Painting of steel tubing and connections of size 40/50/75/100/250 mm bore with connected valves including outer cleaning of pipe and connected valves with suitable existing blue/black /yellow colour with arrow mark approved paint and refixing of pipes with suitable nuts and bolts as existing location complete all as specified and directed.
Painting of motor pump sets including outer cleaning of motor pump sets and connected pipes with suitable existing blue /red colour with suitable marking approved paint and refixing of motor pumps sets with suitable nuts and bolts as existing location complete all as specified and directed.
Supply Dewatering Polyelectrolyte (DWPE ) powder, dewatering of organic sludge from sewage complete all as specified and directed by Engr-in-charge
M & L for servicing and repair /maint of RO Plant of capacity 11000 Ltrs/hrs including replacement of all bag filters ,catridge filter,backwash of membrane (including chemical ) ,tightening of all bends and coupling of PVC Pipe ,checking of electrical and control wiring etc including testing of water from authorised lab after every service to check the desired value of drinking water ,complete all as specified and directed by Engineer-in-charge . Note :- Spare parts suitable for existing plant required to be replaced shall be separately under respective items .
Supply only Bag filter of size 7 "x 32 "
Supply only Catridge filter of size 40 x 2.5 "
Supply only RO antiscalant for using Reverse Osmosis membrane effective in controlling deposition of inorganic scales effective in presence of chlorine and hardness up to 1000ppm,Effective calcium carbonate dispersion of high PH(up to 10) and alkalinity (upto 750),Excellent scale controle for high silica waters upto 150 ppm complete all as specified and as directed. Make : RADIX-31
Supply only chemical for maintainiing PH value of RO Plant within permisible limit
Supply only salt (NACL) used for regeneration of resin filter installed in RO Plant .
Supply only granuler activated carbon material for Ro Plant
Supply only Stequa 411 AE plastic cylindrical sealed disposable sanitiser refill for disinfication of drinking water with arrangement for operation through suitable feeder in pressurezed line. Replacement Indication : visual & weight variation Operation type : Non Contact,non inhalatory Cylinder Dia : 2.5 Inches +/- 0.5 Inches Cylinder height : 10.0 Inches +/- 0.5 inches Model :Stequa 411 AE or Equaivalent Make :Declibac Technologies Pvt Ltd
S&F in replacement of MCB 5 to 32 Amp, 240 Volts, SP, breaking capacity 10 KA, B curve in the MCB DB and panel complete with connection testing and commissioning complete all as specified. Make: Legrand/SIEMENS/L & T/Havells/Standard
S&F in replacement of MCB 63 Amp, 415 Volt, TP, breaking capacity 10 KA, B curve, in the MCB DB and panel complete with connection testing and commissioning complete all as specified. Make :- Make: Legrand/SIEMENS/L & T/Havells/Standard
M&L for replacement of MCCB 4 pole 250 Amp, 36 KA with adjustable thermal and adjustable magnatic setting including making all incoming and outgoing connections, complete all as specified and as directed by Engr-in-Charge. Make: Legrand/ABB/Siemens/L&T/Havells.
Supply and fixing in replacement of Galvanised steel water tube 100 mm dia, 'Heavy class', with all fitting including cutting, threading etc as per site requirement and drilling holes/fixing clamp set for taking branch connection from main pipe line & fixed on walls or laid under floors complete all as specified and directed.
M&L for sub-main wiring with two four core 4 sq mm FR PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of massinory including 25 mm dia non-metallic PVC conduit fixed in wall including two core 2.5 sq mm copper earth continuity wire, accessories and connecting to earth dolly including taking down old u/s submain wiring complete, all as specified and as directed by Engr-in-charge.Make : Polycab/Havells/Plaza HPL/Gloster
Supply and laying LT XLPE insulated 1100 volt grade heavy duty cable multi stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel strip wire or tape and connecting up to the electrical system with suitable size of aluminium lugs of size 4 sqmm 4 core including taking down old u/s cable, complete all as specified and directed.
Supply and fix in repair of indicator lamp assembly LED type with red/green/blue for phases R,Y,B complete all as specified suitable for LT panels complete all as specified and directed.
Supply and fix in repair of Digital voltmeter 0-500 volt of size 96 Sqmm suitable for LT panels complete all as specified and directed.. Make:- AE/MECO/SECURE/SCHNEIDER.
Supply and fix in repair of Digital ampere metre 0-300 Amps of size 96 Sqmm suitable for LT panelscomplete all as specified and directed. Make:- AE / MECO / SECURE / SCHNEIDER.
Supply only Compressor lube oil 320 Grade Make Castrol/Power Supreme - for Top up and filling up the oil in the sump after completely flushing the old oil out of the tank and cleaning of the tank for fresh filling all as directed by Engineer-in-charge.
Repair /maint of centrifuge machine Make :Haller including removing & fixing of spare parts cleaning and greasing of all spare parts with suitable chemical and tight with bolts ,nuts ,washer etc all as specified and directed by Engineer-in-charge . Note :- Spare parts suitable for existing centrifuge machine required to be replaced shall be separately under respective items
M & L for servicing and repair /maint of air compressor Make :Usha capacity 667 cubic meter/hrs including removing & fixing of spare partscleaning and greasing of piston ,piston rings,piston shafts,coupling ,bearings,connecting rods, bushes,gaskets,air filters etc with suitable chemical all as specified and directed by Engineer-in-charge . Note :- Spare parts suitable for existing compressor required to be replaced shall be separately under respective items
Supply and fixing in repair of fan belt of Make - Finner/ Dunlop as required at site for the capacities of USHA Air compressor
M&L for mild steel work for pulley structure suitable iron size including cutting, bending to shape, welding drilling holes, jointing by nuts, bolts, washers etc using MS chanel, equal angle, flat iron, sheet steel etc including two coat of painting over a coat of red oxide primer paint, including taking down old u/s mild steel work all as directed by Engr in Charge.
S & F sheet metal work made out of galvanised MS sheet 22 Gauge for cover shed for motors of any capacity including dismantling and refixing of the accessories in the new unit including taking down old u/s mild steel sheet complete all as specified and directed.
Supply and filling Bio pac MBBR media cylindrical shape with external fins with 15 mm height and 22 mm diameter ,black colour and effective surface area of media 400 m2/m3 complete all as specified and directed by Engineer-in-charge
Testing and checking to maintain clear treated water from sewage treatment plant with the effluent quality as below :- (a) BOD < 10 mg/ ltr (b) COD - 150 mg/ ltr (c) DO - 20 mg/ ltr or more (d) TSS < 10 mg/ ltr (e) PH - 6.5-8.5 (f) Oil and Grease < 10 mg/ ltr (g) Coliform < 100 MPN/ 100 ml (h) Res Chlorine < 1 mg/ ltr (i) Testing from NABL certified laboratories fortnightly to be carried out for item (a) to (g) above and proper record to be maintined. (ii) Residual Chlorine test to be carried out daily as per item No (h) above and proper record will be maintained. The testing record to be shown to JE concerned daily and weekly to Engr-in-Charge. Note : Rate quoted by the tenderer also includes the following (a) Cost of testing and maintaining record. (b) Cost of chlorination to achieve specified residual chlorine contents. (c) Cost of chemical required to obtained effluent quality as above (a) to (g).
Cutting and uprooting grass, vegetation shrubs, bushwood undergrowth, roots and trees not exceeding 30 cm girth (measure one metre above ground level) and removing rubbish to a distance upto 50 metres outside the periphery of the area, and out from area of sewage treatment plant complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of gland packing dori with 10 mm in suitable size motor pumpsets complete all as specified and directed by Engineer-in-charge
Altoch-GP (Calcium based granular disinfectant more stable than chlorine gas & stronger than bleaching powder and sodium hypochlorite) for treatment of drinking water. Packing in 45 Kg plactic drums. Make : Declibac, Brand name : "ALTOCH-GP" or equivalent.
Disconnecting & dismantling the defective three phase induction motor squirrel cage of make :ABB and of capacity 2 HP 415 Volts, 50 HZ, 2850 RPM and from foundation by opening of coupling and foundation bolts and spray painting with one coat of existing colour paint and writing SM/MES No with white paint including replacement of center ring,ball bearing suitable size,pump motor assembly with tyre,bearing bowl with ball bearing plate and housing,remetaling ,turning and grinding to pump shaft,reparing to bearing housing,repair to impeller seat,replacement of coupling as per existing size,relacement of gun metal bush including installing, commissioning and testing on full load complete all as specified and directed. Note : Any other items required to make functional is deemed to be included in this quoted rate. (a) Transportation charges from installation to contractor works shop and back after repair are included in the rates quoted against the above items. (b) Cost of nuts, bolts, washers, connection plate, grease/ lubrication to bearing bushes etc, are deemed to be included in this item. (c) Old dismantled winding wire will be contractor property for which credit has been considered under schedule of credit.
All as per srl item No.41 here-in-before but Make: Siemens motor of capacity 1 HP.
All as per srl item No.41 here-in-before but Make Kirloskar motor of capacity 5 HP.
All as per srl item No.41 here-in-before but Make :ABB motor of cap 7.5 HP.
All as per description of serial item No.41 here-in-before but Make :ABB motor of capacity 30 HP.
Repair & Maint and fixing of Fully Automatic Star-delta starter, AC 3 phase, 415 Volt, 50 Hz with sheet metal enclosure type suitable for minimum 30 HP motor including making connections complete all as specified and directed by Engineer-in-Charge.
Supply only single phase preventor suitable for 3 phase, 415 Volts including all necessary wiring. Make : Minilac or equivalent.
Supply only 3 pole power contactor ML-1.5. Make : L&T cat no. SS91851COOO
Supply only 3 pole power contactor ML-2. Make : L&T cat no. CS96005LOOO
Supply only 3 pole power contactor ML-3. Make : L&T cat no. CS90907LOOO
Supply only overload relay range 13-21/20-32 Amp 230 Volt. Make : L&T cat no.SS91859OOCO/SS91859OOEO
Supply and fix in replacement of overload relay range 28-42 amp : L&T/BCH
M&L for cleaning and scraching the surface of filter bed ,walls,floor truffs,drains etc,by wire brushes or other wise to remove the deposited mud scms etc and washing the filter bed with clean water complete all as directed by Engineer - in charge
Taking out Existing exhausted filter media from filter bed of any size /depth including removing material to distance exceeding 50 meter but not exceeding 100 meter complete all as specified and as directed by Engineer - in -charge.
Supply and laying the natural gravel pebbles of size 10 mm to 20 mm grades complete all as specified and as directed by engineer in charge
Supply and laying the natural gravel pebbles of size 6mm to 10 mm grades complete all as specified and as directed by engineer in charge
Supply and laying the natural gravel pebbles of size 2 mm to 6 mm grades complete all as specified and as directed by engineer in charge
Supply and laying white silica sand filter media of effective size 0.5 mm to 2mm as per sample in GE office complete all as specified and directed by Engineer -in-Charge. Note: Gravel for filter bed shall be obtained from approved source and filter sand shall be as per sample Kept in GE office.
Supply and fixing in repair of flange type CI foot valve 100 mm dia size and 20 mm thickness complete all as specified and directed by Engineer-in-Charge.
Material and labour for cleaning RO water storage tank of storage capacity 10000Ltrs, material from the bottom and sides and removing to a distance not exceeding 50 metre from the outer perimetre of tank and depositing/spreading where directed by Engr-in-charge. including preparation of surface by wire brushing and washing the surface by clear water including removal of roots and uprooting of grass etc. all around upto 2 metre from plinth of tank, complete all as specified and directed by Engineer-in-Charge.
supply and fixing testing and commissioning of CPVC pipes of size 50mm including using elbow,union,tee,etc as per site reqquirement including removing old unserviceable pipes complete all as specified and as directed. MAKE :Prince
supply and fixing testing and commissioning of CPVC pipes of size 20mm including using elbow,union,tee,etc as per site requirement including removing old unserviceable pipes complete all as specified and as directed. MAKE :Prince
supply and fixing testing and commissioning of CPVC Ball valve union type of size 20mm including using elbow,union,tee,etc as per site requirement including removing old unserviceable valves complete all as specified and as directed. MAKE :Prince
supply and fixing testing and commissioning of CPVC Ball valve union type of size 50mm including using elbow,union,tee,etc as per site requirement including removing old unserviceable valves complete all as specified and as directed. MAKE :Prince
supply and fixing testing and commissioning of flow meter of range 1600-16000 (panel mount) icluding suitable size of washers etc.and any small item is required for fixing in panel is included in this rate complete all as specified and as directed. MAKE :Prince
supply and fixing testing and commissioning of flow meter of range 250-2500 (panel mount) including suitable size of washers etc.and any small item is required for fixing fixing in panel is included in this rate in panel .complete all as specified and as directed. MAKE :Prince
supply and fixing testing and commissioning of TDS meter model no CI -550 (panel mount) complete all as specified and as directed. MAKE :Prince
Contract Amount shall be derived after affecting the amount of Schedule of Credit in General Summary on serial page No 16 of tender documents.
DASHMESH ENTERPRISES
SRI SAI CONSTRUCTION COMPANY
M/s Tiwari & Sons
M/S VISHNU ENTERPRISES
RATHORE ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .