Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC | L1 | Accepted-AOC LOWER RATE QUOTED | |
| 2 | L2₹24.0 L+₹84,780 (3.66%)Rejected-AOC SAINIK SOCIETY HITKARINI DENTAL COLLEGE DUMNA ROAD JABALPUR MP 482001 | JABALPUR | JABALPUR | MP | 482001 | L2 | Rejected-AOC HIGHER RATE QUOTED | |
| 3 | L3₹25.3 L+₹2.2 L (9.34%)Rejected-AOC | L3 | Rejected-AOC HIGHER RATE QUOTED | |
| 4 | L4₹26.7 L+₹3.6 L (15.4%)Rejected-AOC | L4 | Rejected-AOC HIGHER RATE QUOTED | |
| 5 | L5₹27.8 L+₹4.7 L (20.2%)Rejected-AOC VILLAGE PO BUD BUD DIST BURDWAN WB PS BUD BUD PIN 713403 | BUD BUD | BURDWAN | WEST BENGAL | 713403 | L5 | Rejected-AOC HIGHER RATE QUOTED |
Tender Value
₹33.7 L
EMD Value
₹67,400
Closing Date
14 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
As per BOQ
2023_MES_629417_1
8500-040/E8
Open Tender
Civil Works
Works
180 days
PANAGARH
As per Tender documents
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹67,400
Yes
17 Jan 2024
23 Nov 2023
15 Dec 2023
23 Nov 2023
14 Dec 2023
7 Dec 2023
Amount
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M&L for fly ash brick brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM (1:4) complete all as specified and directed. Make : ACC/Lafarge/L&T/Shyam steel Pvt Ltd
Taking down cement plaster, any description on brick or stone walls and ceiling ,chajja, landing etc including racking of joints hacking for key scrubbing down with water etc and removing rubbish off the premises complete all as specified and directed.
M&L for 15mm thick rendering in CM (1:6) on internal surfaces of brick masonry wall finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in CM (1:4) mixed with water proofing compound on external surfaces of brick masonry wall finished even and and smooth with out using extra cement (water proofing item to be paid separately) complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed. (Make : Pidilite Industries/ Impermo/Snowcem India Ltd/Sika)
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash on walls complete all as specified and directed.
Taking chowkats or frames with out taking shutter n.exc 1.50 Sqm complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of cement based paint on new plastered surfaces including preparation complete all as specified and directed.
M&L for two coats of syntetic enamel paint on old steel surfaces including preparation complete all as specified and directed.
Dismantling plain or corrugated, semicorugated sheet in roof covering complete all as specified and directed.
M&L for Pre-painted galvatume aluminum zinc coating @150 GSM GI based semi/fully corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by Engr-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating @150 GSM GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in Ridges fixed with self tapping screws complete all as specified and directed.
M&L for flat iron fillets (for securing wire mesh, CGI Sheets etc.), Hand rails, half round or other steel section including embedding in concrete and screwing etc, wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge complete shall as specified.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, locking arrangement etc all complete as per architectural drawings and the directions of Engineer-in-charge etc complete all as specified
S&F 4mm thick sheet glass ordinary quality with oil putty in square n.exc 0.5m in each pane complete all as specified and directed.
S&F steel windows with side hung shutters (minimum wt of steel section should be 1.42 kg/M) including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed.
All as per item No 19.00 mentioned above but without glazing bars complete all as specified and directed.
M&L for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Dismantling of wall or ceiling boards of any thickness including cover fillets complete all as specified and directed.
S&F 605mm x 605mm Anodised aluminium snap grid frame work for false ceiling with all necessary aluminum angle & Tee arrangement with and including fixing cleats screws etc complete all as specified and directed.
S&F Hangers 4 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3 mm size 60mm long complete all as specified and directed.
S&F 6mm thick (non asbestos fiber) designer building boards fixed in aluminium frame work in ceiling flat or sloping with screw complete all as specified and directed.
Demolition of cement concrete (un-reinforced) n.exc15 cm thickness of any description and in any position not otherwise specifically provided and removing rubbish off the premises complete all as specified and directed.
M&L for 75mm thick PCC 1:2:4 type B-1 (using 20mm graded coarse aggregate) in flooring finished even and smooth with using extra cement with nominal reinforcement complete all as specified and directed. Note : Reinforcement shall be measured and paid separately.
M&L for 75mm thick PCC 1:4:8 type D2 (using 40mm graded coarse aggregate) in sub base complete all as specified and directed.
M&L for 75 mm thick PCC type C-1 1:3:6 (using 20 mm graded stone aggregate) finishing the as in Plinth protection surfaces even and smooth without using extra cement complete all as specified and directed..
M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in surface channels and drains complete all as specified and directed.
M&L for Cement Concrete, 1:2:4, type B1 (using 20mm graded stone aggregate) as in bed block, coping ,lintel upto 1.50 m span, cills, kerbs etc complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F roof trusses (framed), trussed purlins, angle , crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc Fe-410-W (Gde-E-250) quality-A complete all as specified and directed.
M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on newly steel surfaces of any description over 10cm in width or girth not otherwise described including preparation of surfaces and as all specified
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on old steel surfaces of any description over 10cm in width or girth not otherwise described including preparation of surfaces and as all specified
S&F welded steel wire fabric supplied and fixed complete to wood or steel members complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
M&L for repairs to crack portion with Jacketing technique, taking down the extg plaster up to brick wall surface of min 200mm wide, cleninng the loose particles on surface of brick work along the length of the crack and filling the gap/crack area with PCC 1:1.5:3 type A0 using 12.5mm aggregate up to brick surface and inserting the welded mesh of size 25X25X2mm dia along the crack on both sides of the wall surface fixed with, drilling holes 10mm dia on either side of the crack by means of drilling mechane trouoght the full width of the wall @ 25cm c/c and insert 8/10mm dia rod in the drilled holes, welded with horizonal rod to with hold the welded mesh and applying grit plaster 1:1:2 using 4mm and down aggregate finished even and smooth with out using extra cement complete all as specified and directed.. Note: Reinforcement and welded mesh will be measured and paid separately.
M&L for Chequered cement pre-polished coloured concrete tiles 30cm x 30cm x 25mm thick with mixture of grey cement and pigments set, jointed and pointed in neat cement slurry over cement screed bed 15mm thick in CM (1:6), including including dismantling wall tiling and cement mortar bedding complete all as specified and directed.
Mild steel TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Excavating in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
M&L for moorum filling in floors or pavings, laid in layers n.exc15 cm thick, spread, levelled and rammed including watering complete all as specified & directed
M&L for PCC 1:3:6, D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete all as specified and directed
M&L for hardcore of broken stone or boulder of gauge exc 63mm but n.exc 75 mm deposited, spread & leveled in lyers n.exc 15 cm thick watered & rammed to a true surface complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material (soil) n.exc 50m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified & directed
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) with Old size bricks complete all as specified and directed.
Extra for forming fair finished drain or channel upto 40 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
M&L for PCC 1:3:6 type C1 as in lintels / beam upto 1.5m clear span, and other similar bands, copings, kneelers, apex stones, bed plates, kerbs and haunching/ benching, water troughs and the like including weathering, slightly rounded or chamfered ang complete all as specified & directed
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) on wall surface and finishing even and fair complete all as specified and directed.
M&L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. Make : ACC/Lafarge/L&T/Shyam steel Pvt Ltd
M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. (Make: M/s Apex Ultima of Asian/ Weather Coat all guard of Berger/Xtra Tough of Shalimar)
M&L for two coats oil bound distempering on new plastered surfaces over a coat of alkali resistant primer over a coat of putty to bring the plastered surface uniform complete all as specified and directed
S&F SS Double Handle of size 250mm long fixed in toughned glass door complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work finished even and smooth with out using extra cement complete all as specified and directed.
M&L for complete removal of existing surface preparation of old plastered surface of wall for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces complete all as specified and directed. (Make: M/s Apex Ultima of Asian/ Weather Coat all guard of Berger/Xtra Tough of Shalimar).
M&L for 18-20mm thick marble machine cut in skirting/dado laid over cement screed and jointed with grey cement slurry including cutting and polishing of Black marble Black Zebra Kishangarh using white cement slurry is instead of grey cement slurry over and including10mm thick rendering CM (1:3) for laying floor finish complete all as specified and directed.
M&L for Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed..
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
M&L for Vitrified light shade tiles 10mm thick (Square or rectangular) polished, area of each tile not exc 0.36 Sqm in floors etc jointed in neat slurry and pointed in white or coloured cement to match the shade using coloured tiles laid over and including screed bed or bedding layer of 15mm thick in CM (1:6) complete all as specified and directed. (Note : Design, shade and pattern of fixing of tiles shall be as directed by Engr-in-charge)
All as per item No 61.00 above but as in skirtings/ dado over 10mm thick in CM (1:3) complete all as specified and directed.
S&F Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat/stepped surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (Fillets, metal frame work and G.I. wire mesh paid separately) GI/Aluminum framework with screw all as specified and directed.
S&F Anchor fasteners 12mm dia 75mm long including necessary drilling in RCC floor/ concrete surfaces complete all as specified and directed
Dismantling, floor, hearth or wall tiling /terrazo including cement mortar bedding but not backing and removing rubbish off the premises complete all as specified and directed.
M&L for two coats of oil bound distemper over a coat of alkali resistant primer including preparing of new plastered surfaces of ceiling complete all as specified and directed. Make: Asian Tractor/Berger Bison/Shalimar Premium Acrylic
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with CM (1:3) complete all as specified and directed.
S&F PVC (SWR) pipe fixed in walls/ as Gutter 150mm die with necessary clamp complete all as specified and directed.
S&F 12mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required, Handles, locking arrangement , rubber gasket/beading etc complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
S&F 10mm thick Toughened glass as in hinged doors, partitions automatic doors partition and similar work including cutting to shape, drilling holes required complete all as specified and directed.
E/M PORTION Taking down carefully aluminium conductor point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling rose, pendents, regulators sockets etc and removing (except those to be reused shall be kept in safe custody at the site) and making good disturbed surfaces of walls, floors etc to match with the existing complete all as specified and directed.
M&L for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size heavy grade PVC conduits fixing with SS saddle max 1 mtr apart and fittings like socket, elbow, bend etc of medium grade, including PVC (white) terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectional area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
All as per item No 73.00 above but One 3 pin 5 Amps socket out let points on independent board complete all as specified and directed.
All as per item No 73.00 above but 5 Amp socket on same board with other switches complete all as specified and directed.
Material and labour wiring for socket out let on independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size heavy grade PVC conduits fixing with SS saddle max 1 mtr apart and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 4.0 sqmm nominal cross sectional area multistranded copper conductor,PVC insulated unsheathed FRLSH cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
S&F switch piano flush type, single pole, 5/6 Amps, one way complete all as specified and directed.
S&F switch socket combination 2 in 1 multipurpose 5 pin, (6 Amps) flush type controlled by one switch complete all as specified and directed.
S&F socket outlets 2 in 1, 5 pin, 5/6 Amps flush type 230/240 V complete all as specified and as directed
S&F switch socket combination 5 in 1, 6 pin, (5/16 Amps) flush type controlled by one switch complete all as specified and as directed
S&F ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified and as directed
S&F stepped type electronic fan regulator flush type 240 Volts complete all as specified .
S&F submain two single core 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable PVC insulated unsheathed 1100 volts grade drawing in and suitable size heavy grade PVC conduits fixing with SS saddle max 1 mtr apart including 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 volts grade as earth wire complete all as specified and directed. (Note: Three runs cable and PVC conduit will be measured as a single unit)
S&F submain two single core 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable PVC insulated unsheathed 1100 volts grade drawing in and suitable size heavy grade PVC conduits fixing with SS saddle max 1 mtr apart including 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 volts grade as earth wire complete all as specified and directed. (Note: Three runs cable and PVC conduit will be measured as a single unit)
S&F wall LED security light fittings 35 watt, 230 volts, minimum lumn output 100 lumen/watt, made up of pressure dia cast housing with prismatic polycarbonate diffuser and industrial LED with secondary optic and IP-65/66 including necessary connection complete with all accessories including connected with 3 core copper cable of suitable 1.5 sqmm size complete allas specified and directed. Make: Havells/Jaquar/Bajaj/CG
S&F wall mounted LED light fittings 1 x 10 watt, 230 volts, bulkhead luminires including LED driver holder connecting up including connected with 3 core copper cable of suitable 1.5 sqmm size complete allas specified and directed. Make: Havells/Jaquar/Bajaj/CG
S&F LED light fitting 1 x 20 watt box type with same make LED tube rod side connection AC decorative box type 4' long with driver, holder including LED tube connecting up with complete all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete all as specified and directed. Make: Havells/Jaquar/Bajaj/CG
S&F recessed mounted 2' x 2' LED lminaire 36 watt for grid ceiling minimum lumen output 100 lumen/watt pre-treated CRCA frame powder coated with difused profiled including necessary connection complete all as specified and directed. Make: Havells/Jaquar/Bajaj/CG
S&F epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral, 8 ways, with mounting fitted with 200 Amps rated bus bar, DIN channel, neutral link and incoming contact complete all as directed. Make : ABB/Legrand/Hager/Schneider
S&F MCB SPN 32 Amps, 'C' Series 10KA, 240 Volts and to be housed in DBs complete including necessary connection all as specified and directed. Make : ABB/Legrand/Hager/Schneider
S&F MCB SP 6-32 Amps, 'C' series 10KA, 240 Volts and to be housed in DBs complete including necessary connection all as specified and directed. Make : ABB/Legrand/Hager/Schneider
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 25 x 4 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 32 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion.
S&F in repair D clamp of strip size 25x6 mm with bols, nuts & washers including making shape for fixingon 40 mm dia GI pipe and inclusive of one primer coat ,one under coat, one finish coat of paint complete for hanging of ceiling fan all as specified and as directed.
M&L for taking down of ceiling fans of any sweep and transportation to work shop including dismantling for repair/overhauling, oiling, greasing, varnishing and replacement of unserviceable accessories like capacitor, connector etc. After repair re-assembling fan, testing for efficient functioning including hanging it back in position and provn of 0.5 Sqmm copper flexible twin twisted cable (length not exceeding 0.5 metre) from ceiling rose to fan, complete all as specified and as directed by Engrs-in-Charge. Note: Capacitor and Connector are measured & paid separately
M&L for painting of ceiling fans upto 1400mm sweep carefully, dismantling fan blades and paint with one coat of synthetic enamel paint including filling cavities with filler after cleaning all dust etc, complete all as specified and as directed by Engrs-in-Charge.
Supply only Capacitor 2.5 mfd, 230 Volts, AC, 50 Hz, 440 VAC for ceiling fans complete all as specified and as directed. Make: Universal/Bajaj/ Havells
Supply only PVC connector for Ceiling fan of 1200/1400mm sweep including all connection complete all as specified and directed.
M&L for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including sheet metal modular box for suitable fame 2 to 8 module size and 1.5 sqmm nominal cross sectional area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Note: (i) Three runs cable and PVC conduit will be measured as a single unit. (ii) Quoted rate shall be included for necessary chasing, cutting and making good as per existing specification)
All as per item No 98.00 above but One 3 pin 5 Amps socket out let points on independent board complete all as specified and directed.
All as per item No 98.00 above but 5 Amp socket on same board with other switches complete all as specified and directed..
M&L for point wiring for power point controlled by one, one way switch using 4 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including sheet metal modular box for suitable feame 2 to 8 module size and 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Note: (i) Three runs cable and PVC conduit will be measured as a single unit. (ii) Quoted rate shall be included for necessary chasing, cutting and making good as per existing specification)
S&F switch modular type 6 Amp one way, one module, single phase, complete all as specified and directed. Make : Legrand/Anchor(wood)/ABB
S&F switch modular type 16 Amp one way, one module, single phase, complete all as specified and directed. Make : Legrand/Anchor(wood)/ABB
S&F socket outlet 6 Amps, 5 pin, modular type, 2 module, single phase complete allas specified and as directed Make : Legrand/Anchor(wood)/ABB
S&F socket outlet 6/16 Amps, 5 pin, modular type, 2 module, single phase complete allas specified and as directed. Make : Legrand/Anchor(wood)/ABB
S&F submain two single core 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable PVC insulated unsheathed 1100 volts grade drawing in and suitable size PVC conduit (ISI Marked) concealed including 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 volts grade earth wire complete all as specified and directed. (Note: (i) Three runs cable and PVC conduit will be measured as a single unit. (ii) Quoted rate shall be included for necessary chasing, cutting and making good as per existing specification)
S&F submain two single core 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable PVC insulated unsheathed 1100 volts grade drawing in and suitable size PVC conduit (ISI Marked) concealed including 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 volts grade earth wire complete all as specified and directed. (Note: (i) Three runs cable and PVC conduit will be measured as a single unit. (ii) Quoted rate shall be included for necessary chasing, cutting and making good as per existing specification)
S&F wall mounted decrative (Apple) type LED light fitting 1 x 12 watt with LED lamp 12 watt capacity, PC unbreakable complete all as specified and directed. Make:Havells(LHE0FTE1TZ1W012)/Crompton/Jaquar/ Bajaj
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) without remote complete all as specified and as directed. Make : Havells/Usha/Bajaj/CG
S&F stepped type electronic fan regulator modular type 240 Volts ISI marked complete all as specified and as directed. Make : Legrand/Anchor(wood)/ABB
SINGH CONSTRUCTION
M/s BISWAJIT GHOSH
S.P.S. SUPPLIERS
rahul enterprise
SANJAY KUMAR SUPAN
SARASWATI ENTERPRISE (INDEX NO CEEC D-81)
M/S N B SEN CONSTURCTION
M/S Ali Trading Co
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .