| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC | L1 | Accepted-AOC Accepted being Lowest Bid Value | |
| 2 | L2₹25.1 L+₹1.2 L (5.01%)Rejected-AOC | L2 | Rejected-AOC Rejected being L2 bidder | |
| 3 | L3₹25.4 L+₹1.5 L (6.29%)Rejected-AOC | L3 | Rejected-AOC Rejected being L3 bidder | |
| 4 | L4₹26.7 L+₹2.8 L (11.7%)Rejected-AOC | L4 | Rejected-AOC Rejected being L4 bidder | |
| 5 | L5₹27.7 L+₹3.9 L (16.2%)Rejected-AOC PO BUD BUD DIST BURDWAN WEST BENGAL PIN 713 403 | BUD BUD | BURDWAN | WEST BENGAL | 713403 | L5 | Rejected-AOC Rejected being L5 bidder |
Tender Value
₹27.2 L
EMD Value
₹54,440
Closing Date
17 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE PANAGARH
HQ CWE PANAGARH, MES, PO - PANAGARH, DIST - BURDWAN, WB, PIN - 713420
PROVN OF JCOS LIVING BLOCK WITH ATTACHED TOILET BATHROOM AT MAHAR UNDER GE PANAGARH
2022_MES_502584_1
8758/E8
Open Tender
Civil Works
Item Rate
180 days
PANAGARH
Pl refer Tender Documents
7 documents required · 7 mandatory
₹500
GE PANAGARH
₹54,440
Yes
8 Mar 2022
19 Jan 2022
19 Feb 2022
19 Jan 2022
17 Feb 2022
3 Feb 2022
60 days
Amount
B/R PORTION
Excavation in trenches not exc 1.5m wide and n. exc. 1.5m deep for foundation etc and getting out in soft/loose soil , complete all as specified and as directed.
Excavation in trenches not exc 1.5m wide and exc 1.5m deep and n. exc 3 m deep for foundation etc and getting out in soft/loose soil , complete all as specified and as directed.
M&L for sand filling under floors or in foundation including watering and consolidation, complete all as specified and as directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in bed concrete for foundation filling & mass concrete, complete all as specified and as directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
All as per item No 1.05 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, complete all as specified and as directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter, complete all as specified and as directed.
M&L for reinforced cement concrete (Design Mix) M-25 (20mm graded stone aggregate) foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc. and mass concrete etc, complete all as specified and as directed.
M&L for formwork for rough finished surface of concrete (flat surface) to sides of pillars, posts, struts, piers, columns, and stanchions for rough finished surfaces of concrete, complete all as specified and as directed.
M&L for reinforced cement concrete (Design Mix) M-25 (20mm graded stone aggregate) in columns, pillars, piers, etc, complete all as specified and as directed.
M&L for formwork to sides of floor and roof beams, beam haunchings sides and soffits , and similar work, vertical or to batter, complete all as specified and as directed.
M&L for reinforced cement concrete (Design Mix) M-25 (20mm graded stone aggregate) in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work for rough finished surface, not exceeding 200m thick (Horizontal or sloping), complete all as specified and as directed.
M&L for reinforced cement concrete (Design Mix) M-25 (20mm graded stone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed.
M&L for rendering 10 mm thick on fair faces of roof surfaces or concrete surface in CM (1:4) complete all as directed finished even and smooth with using extra cement, complete all as specified and as directed.
M&L for preparation of new surfaces of roof and applying two coats of Polyurethane (PU) acrylic based water proofing liquid compound over and including one coat of self priming primer @ one litre per 10 Sqm with reinforcing fabric sheet as per manufacturer's instructions to stop leakage/seepage from roof/wall complete all as specified and as directed by the Engr-in-Charge (Notes :- (i). As per description of this item, minimum two coats of Polyurethane (PU) acrylic based water proofing liquid compound over one coat of primer shall be carried out as per manufacturer's instruction. Please note no price adjustment shall be made, if as per manufacturer's instructions more coats of Polyurethane (PU) acrylic based water proofing liquid compound and primer are required for roof treatment. (ii). Quoted Rate shall be deemed to be included for work in building/structure of any height.
M&L for brickwork with fly ash bricks straight or curved on plan to any radius built in CM 1:6 , complete all as specified and as directed.
M&L for brickwork with fly ash bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:6, complete all as specified and as directed.
M&L for rendering 15 mm thick with CM 1:6 on fair faces of brick work or concrete wall surfaces & finishing the surfaces finished even and smooth without using extra cment, complete all as specified and as directed.
M&L for rendering 15 mm thick cement plaster with CM 1:4 on external fair faces of brick/concrete work surfaces finished even and smooth (without using extra cement) including WPC , complete all as specified and as directed. Note: WPC shall be measured and paid separately.
M&L for rendering 5 mm thick with CM 1:3 on fair faces of brick work or concrete wall surfaces & finishing the surfaces fair and even on ceiling, complete all as specified and as directed.
Supply only Integral waterproofing compound , complete all as specified and as directed.
M&L for Preparation of new wall surfaces and applying two coat of oil bound distemper over a coat of alkali resistant priming paint over one coat of putty minimum 1 mm thick, complete all as specified and as directed.
M&L for finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) after preparation of new wall surfaces with complete removal of existing finishes, complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation new plastered surfaces and applying three coat of white washing on ceiling, complete all as specified and as directed.
M&L for broken bricks hard core gauge n.exc 63mm deposited, spred and levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces, complete all as specified and as directed.
M&L for 75 mm thick PCC type D-2, 1:4:8 (using 40 mm graded stone aggregate) finishing the surfaces even and smooth without using extra cement, complete all as specified and as directed.
M&L for cement concrete type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) 25 mm thick as in floor for receiving screed bed, complete all as specified and as directed.
M&L for Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry over 15 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed.
M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match coloured tiles over 10 mm thick screed bed surface in CM 1:3 , complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil, complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be convered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvant cement for stiles and plain colour PVC sheet top rail, lock rail and bottom rail on either side and as gap insert of top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitabale PVC sheet beading, and jointed together with solvant cement, and S&F in the frame at side as per specification and drawing, complete all as specified and as directed.
S&F solid PVC door frame of size 50 x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube , complete all as specified and as directed.
M&L for Plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed with 2nd class Hardwood, complete all as specified and as directed.
M&L for Flush shutters of 40 mm thick , solid core construction with block board core and plywood face panels, commercial type on both sides , complete all as specified and as directed.
M&L for Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) , complete all as specified and as directed.
M&L for Anodised powder coated aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified and as directed.
S&F Sheet glass 5.5 mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane, complete all as specified and as directed.
M&L for PCC (1:2:4) type B-0 as in bed blocks for hold fast including necesssary formwork , complete all as specified and as directed.
S&F mild steel flat iron as in hold fast, clamps articles conforming to FE 290 Gde-E-165, complete all as specified and as directed.
S&F 100 mm size butt hinges extruded aluminium alloy with galavanised mild steel hing pin anodised and fixed type C-21, complete all as specified and as directed.
S&F 200 mm long Aluminium, anodised, barrel tower bolt of extruded section, complete all as specified and as directed.
S&F aluminium handles, cast type, anodised 150mm long, complete all as specified and as directed.
S&F 300 mm long Aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy , complete all as specified and as directed.
S&F for 15 mm dia medium grade galvanised steel water tubing,with all fittings and fixed complete to walls and ceiling or laid in floors, complete all as specified and as directed.
S&F Wash down EWC white (Pedestal pattern ), complete all as specified and as directed.
Supply only 10 ltrs PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, complete all as specified and as directed. Note: Fixing rate included in Ser item No 1.47 above of WC item.
S&F Vitreous China under counter wash basin white , flat back, size 500 X 400 X 130 mm including cutting for pinning in ends of brackets, complete all as specified and as directed.
S&F Stop valves of 15 mm bore, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions , complete all as specified and as directed.
S&F 15mm dia bib tap cast copper alloy chromium plated fancy type , screwed down screwed for iron pipe or for brass ferrule and fixed, complete all as specified and as directed.
S&F 15 mm pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type , screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, complete all as specified and as directed.
Supply only flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern, complete all as specified and as directed.
S&F Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union, complete all as specified and as directed.
S&F Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed for 15 mm diameter pipe, complete all as specified and as directed.
S&F soap dish, vitreous china white, approximate size 160 x 160 x 90mm, complete all as specified and as directed.
S&F PVC connection 15 mm size with PTMT nuts of length 450mm, complete all as specified and as directed.
S&F 20mm bore for gun metal glove or gate valves with iron wheel head screwed both ends for iron pipe, complete all as specified and as directed.
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and as directed.
S&F PVC (SWR) floor trap 75mm dia of outlet plain with grating including jointing with solvent cement , complete all as specified and as directed.
S&F PVC (SWR) bends any radius of 75 mm bore with access door, complete all as specified and as directed.
M&L for Salt -glazed stoneware drain pipes of 150 mm internal dia laid in trenches and jointed , complete all as specified and as directed.
M&L for concrete bed to 150 mm dia drain pipes including packing under, haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 , complete all as specified and as directed.
M&L for Granite (of any type) work (table rubbed and polishedin steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed.
M&L for PCC (1:2:4) type B-0 as in bed blocks for hold fast including necesssary formwork , complete all as specified and as directed.
M&L for On site Hume Pipe Septic Tank designed to carry sewage and sullage water, excavation in any type of Soil, PCC 1:4:8 below foundation, vent shaft, connection etc., complete for 20 users.
M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6 walls of honey combed masonry with top ring of M-25 Concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M 25/SFRC cover, interconnecting ppes of RCC/ DWC complete filled with brick bats of size 1.2 m by 1.5 m effective depth .
E/M PORTION
Material and labour for point wiring of light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc, complete all as specified and as directed.
Material and labour for wiring of 5 Amps socket out let on Same Boards controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc, complete all as specified and as directed.
Material and labour for wiring of 5 Amps socket out let on independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc, complete all as specified and as directed.
Material and labour for wiring of 15 Amps socket out let on independent Boards controlled by one, one way switch using 4 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc, complete all as specified and as directed.
Supply and fix switch piano flush type, single pole , 5/6 Amps, one way, complete all as specified and as directed.
Supply and fix switch socket combination, 2 in 1 multipurpose 5 pin , (5/6 Amps ), complete all as specified and as directed.
Supply & fix Bell push , flush type , 5 amp , complete all as specified and as directed.
Supply and fix switch socket combination, 5/16 Amps 5 in 1 flush type controlled by one switch, complete all as specified and as directed.
Supply & fix Buzzer, Ding dong, AC 230 Volts, single pole 230 volts, complete all as specified and as directed.
Supply & fix ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps, complete all as specified and as directed.
Supply & fix stepped type electronic fan regulator flush type 240 Volts ISI marked , complete all as specified and as directed.
Supply & fix 01x 18 W LED batten light fittings, with T-8 tube, lighting fixture with extruded polycarbonate complete with all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing , complete all as specified and as directed.
Supply and fix security light fittings 25 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size, complete all as specified and as directed.
S&F decorative wall mounting made out of polycarbonated suitable for and incl retrofit 7 watts LED Bulb. complete all as specified and as directed.
Supply and fix 9 W LED light fitting wall mounted batten 2ft , extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 9 watt , 6000K including necessary connection, complete all as specified and as directed.
Supply & fix exhaust ventilation fan of sweep 300mm,240 volts, BEE 5 star rated, steel body,ISI marked ,complete all as directed by Engr-in-Charge.
Supply & fix ceiling fan 1200mm size , star 3 rated, ISI mark, 240V, 50 Hz , complete all as specified and as directed.
Supplying and fixing two single core, 6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked), concealed, including 6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire, complete all as specified and as directed.
Supply and fixed epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Triple pole and neutral 415 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact, complete all as specified and as directed.
Supply and fixed epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact, complete all as specified and as directed.
Supply and fixed MCCB TPN 125 Amps, 25kA, 240 Volts,ISI marked and to be housed in DBs complete including necessry connection, complete all as specified and as directed.
Supply and fixed MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessry connection, complete all as specified and as directed.
Supply and fixed MCB SPN 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection, complete all as specified and as directed.
Supply & fixing XLPE armoured cable 16 sqmm 4 core,1100 volts grade heavy duty cable,ISI marked passing through pipe, with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed , complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in hard/dense soil, complete all as specified and as directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil, complete all as specified and as directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and as directed.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying, complete all as specified and as directed. (Note : Punned thickness shall be measured).
M&L for sub class B bricks locally available of size 25 x 12.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable, complete all as specified and as directed.
Supply and fixing of electric water heater storage type 25 Ltrs with all fixing arrangement including nuts & bolts etc, complete all as specified and as directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply & fix 25 mm bore GI Tubing medium grade in Trenches/ Floor/Pillar and connection including fitting like socket /Union/Tee/Reducer Nipple etc , complete all as specified and as directed by Engineer in Charge.
Supply & fix 50 mm bore GI Tubing medium grade in Trenches/ Floor/Pillar and connection including fitting like socket /Union/Tee/Reducer Nipple etc , complete all as specified and as directed by Engineer in Charge.
Supply & fix 25 mm bore gun metal globe or gate valve,yoke type, full opening with iron wheel head, screwed both ends, heavy duty, ISI mark for Iron pipe , complete all as specified and as directed by Engineer in Charge.
Supply & fix rotational moulded polyethylene water storage tanks of 500 ltrs capacity (Cylindrical, vertical with closed top with three layered) confirming to relevent IS complete including provision of all inlet outlet overflow and drain pipe fitting , complete all as specified and as directed by Engineer in Charge.
S&F 25 mm bore Ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and as directed.
Jaibalaji Enterprise
BABY ENGINEERING ELECTRICAL MECHANICAL STORES
HIGH HILLS INFRA
ROY ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .