| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAdmitted-Finance | ₹1.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.6 Cr+₹6.8 L (4.46%)Admitted-Finance | ₹1.6 Cr+₹6.8 L (4.46%) | L2 | Admitted-Finance |
| 3 | L3₹1.6 Cr+₹9.5 L (6.19%)Admitted-Finance | ₹1.6 Cr+₹9.5 L (6.19%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M.A.ELECTRICALS L2 | M/S ZAHOOR TRADERS L3 | M/S RAHAT & BROTHERS ELECTRICALS L1 |
|---|---|---|---|---|---|---|
| 1.00Supply Of Material | ||||||
| 1.01 | ABC Bunch Cable 3*120 sqmm | 2,595 | Mtr | 521 ₹13,51,995 | 532 ₹13,80,540 | 495 ₹12,84,525 Lowest |
| 1.02 | PCC pole 8.5 mtr long | 304 | No | 2,920 ₹8,87,680 | 3,250 ₹9,88,000 | 2,850 ₹8,66,400 Lowest |
| 1.03 | Stone Pad 300x300x75mm | 107 | No | 85 ₹9,095 | 84 ₹8,988 | 80 ₹8,560 Lowest |
| 1.04 | Dead & Clamp | 252 | No | 205 ₹51,660 | 195 ₹49,140 | 188 ₹47,376 Lowest |
| 1.05 | Stay rod Complete | 33 | No | 2,205 ₹72,765 | 2,210 ₹72,930 | 2,162 ₹71,346 Lowest |
| 1.06 | STP Pole 11 mtr | 64 | No | 24,550 ₹15,71,200 | 26,500 ₹16,96,000 | 23,910 ₹15,30,240 Lowest |
| 1.07 | V type Cross arm with clamp | 25 | No | 929 ₹23,225 | 935 ₹23,375 | 910 ₹22,750 Lowest |
| 1.08 | T off channel with clamp | 17 | No | 942 ₹16,014 | 950 ₹16,150 | 930 ₹15,810 Lowest |
| 1.09 | 11 kv disc Insulator with fitting | 93 | No | 284 ₹26,412 | 290 ₹26,970 | 276 ₹25,668 Lowest |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
13 Feb 2023, 12:00 pmClosed
SE EDC KASGANJ
SE EDC KASGANJ
EDCK-54/2022-23
2023_DVVNL_771575_1
EDCK-54/2022-23
Open Tender
Electrical Work/ Equipment
Turn-key
90 days
KASGANJ
EDCK-54/2022-23
2 documents required · 2 mandatory
₹5,900
DVVNL WEBSITE
₹1.7 L
15 Feb 2023
4 Feb 2023
13 Feb 2023
4 Feb 2023
13 Feb 2023
4 Feb 2023
Amount
Supply Of Material
ABC Bunch Cable 3*120 sqmm
PCC pole 8.5 mtr long
Stone Pad 300x300x75mm
Dead & Clamp
Stay rod Complete
STP Pole 11 mtr
V type Cross arm with clamp
T off channel with clamp
11 kv disc Insulator with fitting
11 KV pin Insulator with fitting
F Bracket
ACSR Weasel Conductor
Danger board with clamp
Nut bolt & washer off size
Earthing Rod Set Complete
100 kva T/F 11/0.4 kva new
Dropper Channel 100x50x5x2028
LT clamp with nut bolt
Holding clamp for top channel TPMO & fuse set with nut bolt
MS Top Channel 125x65x2210mm
T/F base angel set
11 KV TPMO set complete
LT incoming pannel with metering equipment & fixing arragement (LS)
Danger board barbed wire including jumper
Stay complete (Double Pole)
Red oxide Paint
Alluminimum Paint
Suspention Clamp
I Hook
LT Distrubution box 3 phase 4 wire
MS Top Channel 100x50x2240mm
Guarding Angel 65x65x6x2.5 M long
Holding clamp with nut bolt
LT PVC Cable AL 3.5x150/70 sqmm.
PG clamp for dog conductor
11 KV Fuse set complete
LT ABC cable (3x95+1x35+1x16)
Lt Insu. Piercing Connector 95x50 mm
Piercing Connector 3x95
Clamp for Distrubution Box
Eye Hook with Eye Bolt
LT ABC cable (3x95+1x70+1x16)
20x2500 mm & 6 SWG earthing wire
Alluminimum Lugs 120 sqmm.
11 KV XLPE 3x185 sqmm cabel
11 KV Jointing kit 3x185 sqmm o/d
G.I. Pipe 6" dia
160 mm HDPE 4 PE 80 grade UV HDPE Pipe
63 kva T/F 11/0.4 kv new
Brassing MS angel with clamp
PG clamp for ACSR weasel conductor
Erection Of Material
Erection of single support including complete H.T/L.T fittings S.T. Pole 11 Mtr. SP-55 including Earthing, Grouting & Muffing of pole.
Erection of single support including complete H.T/L.T fittings PCC Pole 8.5 Mtr including Earthing, Grouting & Muffing of pole.
Erection of single support including complete H.T/L.T fittings PCC Pole 8.5 Mtr including Grouting & Muffing of pole.
Fixing Of Danger board
Fixing Of Danger board barbed wire including jumper
Erection of double pole on S.T. pole including the work of complete lineS.T. Pole 11 Mtr. SP-55 including Earthing, Grouting & Muffing of pole.
Fixing of 11 KV TPMO Set Complete
Erection of stay set complete including the work of nuzzling etc.
Erection of Stay set (Double Pole) complete including the work of nuzzling etc.
Laying sagging stringing, binding and jumpering ACSR Weasel conductor
Laying & Fixing of LT ABC cable (3x95+1x70+1x16) sqmm.
Laying of 11 kv cabel cost meter of sand & bricks
Painting of ST Pole with red oxide & ailunimum paint as per RESPO norms
Laying & Fixing of ABC Bunch cable 3x120 sqmm.
Laying & Fixing of LT AB cable 3x95+1x35+1x16 sqmm.
Laying & Fixing of LT PVC cable Al. 3.5 x150/70 sqmm.
Fixing of LT Distiubution Box 3 phase 4 wire in all respect.
Installation of 100 KVA /63 KVA T/F 11/0.4 KVA New in all respect
Installation of LT incoming pannel with metering equipment & fixing arragement (LS)
Laying & Fixing of 11 KV XLPE 3x185 sqmm cabel in all respect.
Connecting HT Cabel connection from 33 kv side & 11 KV side of 10 MVA Power Transformer
Water level earthing by Boring and lowering of G.I. pipe size 40 mm dia & thickness 2 mm into the ground at 20 mtr depth or upto the water level with the lower end of solid copper cone Approx 225 mm long and 750 gm in weight shall be provided and screwed in pipe as well as bringing out a continuous copper wire 6 SWG from the cone up to the ground surface where it will be bolted to the M.S. earth Strip for Transformer body & neutral connection, the earth strip will be welded to the G.I. pipe and neutral earthing support. All required material provided/ supply by the contractor own his cost.
Making of M.S. Angle Ladder type frame of Angle (75x75x8mm) & GI Strip (50x6mm) near power transformer for power cable with concreting of the same in the ground and proper clamping (50x6mm) of the same with transformer cable.
Making of M.S. Angle frame of (75x75x8mm) in L shape to connect T/F Neutral by flexible copper strip including cost of copper strip & wll be connected to newly constructed well type earthing for Power T/F Neutral as per RESPO norms.
M.A.ELECTRICALS
M/S ZAHOOR TRADERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .