| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | Admitted-Finance |
| 2 | Admitted-Finance 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | Admitted-Finance |
| 3 | Admitted-Finance 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | Admitted-Finance |
| 4 | Admitted-Finance NO 14 M C RAJA STREET MITTANAMALLI I A F AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | Admitted-Finance |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
29 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I RD AVADI
AGE I RD AVADI CHENNAI 600054
REPAIRS AND MAINTENANCE OF COOLING APPLIANCE AT CVRDE AVADI
2020_MES_389129_2
8328/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AVADI
As per NIT
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹19,000
Yes
5 Jan 2021
2 Dec 2020
31 Dec 2020
2 Dec 2020
29 Dec 2020
15 Dec 2020
2 Dec 2020 - 15 Dec 2020
60 days
Amount
M&L for servicing complete Split type AC up to 1.5/2.0 Ton capacity of any make as and when ordered including cleaning of air filters, greasing of fan/blower motors, electrical connections etc. as in preventive maintenance all as specified and as directed. Note:Replacement spares, charging of gas, etc. shall be measured and paid separately under relevant items of this Schedule.
M & L for attending low cooling complaint by pressure testing and rectifying the leakages found in the system of split type ACs capacity up to and including 2 Ton capacity including vacumizing,charging and checking the gas pressure to desire level complete for satisfactory functioning all as specified and as directed.Note:Topping up of gas will be measured and paid seperately
M&L for shifting of Air Conditioner,Split type capacity up to 2 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing etc complete all as specified and directed. Note: Topping up of gas and copper tubing will be measured and paid seperately
S&F in replacement hermatically sealed new compressor for split AC of capacity 1.5 Ton including disconnecting the electrical and refrigerant connection of defective sealed unit of split AC of capacity and connection of all pipe line & charging of refrigerant and testing etc complete all as specified and directed. Note: (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
All as per the item 4 above but 2 Ton capacity air conditioner.
S&F Condenser copper coil in replacement after disconnecting the refrigerant connection of defective condenser coil unit of split AC 1.5 Ton and replacing the condenser coil unit connecting the same unit with refrigerant connections etc complete all as specified and directed.
All as per item no 6 above but 2.0 TR capacity complete all as specifed and directed.
Supply and fixing in replacement Condenser Fan motor suitable for split type Air Conditioner of any make up to and including 1.5TR capacity, etc complete all as specified and directed.
All as per item no 8 above but 2.0 TR capacity complete all as specifed and directed.
Supply and fix in replacement of copper cooling coil for 1.5 Ton Split type AC all as directed.
Supply and fix in replacement copper cooling coil for 2.0 Ton Split type AC all as specifed and directed.
Supply and fix in replacement of indoor unit blower fan motor for 1.5 Ton split type AC all as specifed and directed.
Supply and fix in replacement of indoor unit fan motor for 2.0 Ton split type AC all as specifed and directed.
Supply and fix in replacement of outdoor unit fan motor for 1.5 Ton split type AC all as specifed and directed.
Supply and fix in replacement of outdoor unit fan motor for 2.0 Ton Split type AC all as specifed and directed.
Supply and fix in replacement PCB suitable for 1.5/2.0 Ton AC suitable for as per site requirement all as directed
Supply and replace air filter suitable for split AC upto 2Ton any model make complete all as specified and directed.
Supply and fix in replacement starting relay suitable for 1.5Ton A/C all as directed.
All as per item No. 18 above but suitable for 2.0 Ton A/C.
Supply and fix in replacement wiring kit suitable for 1.5 / 2.0 Ton A/C all as directed
Supply and fix in replacement running capacitor 36mfd 230/415 Volt all as directed. Make: Keltron/Sarada/Usha/Tibcon.
All as per item No. 21 but 50 mfd 230/415 all as directed
All as per item No. 21 above but 45mfd 230/415 Volt
Supply and fix in replacement starting capacitor 80/100mfd 230/415 Volt
Supply and fix in replacement thermostat for split AC upto 2TR capacity complete all as specifed and directed.
Supply and Fix in replacement of the PVC drain pipe, flexible, 15mm dia bore fixed on wall with clamps etc for aircondition indoor unit any type & capacity complete all as specified and as directed.
Supply and fix NUF insulation for copper tubing suitable for split AC all as directed
Supply and fix in replacement compressor(sealed unit) as per existing size, specification & make suitable for water cooler of capacity 80 ltrs and connecting up to allthe system including gas charging all as directed.
All as per item No. 28 above but suitable for 120 ltr cap water cooler
All as per item No. 28 above but suitable for 150 ltr cap, water cooler
Supply and fix in replacement of copper condenser coil for water cooler of 80 ltr capacity all as directed.
All as per item No. 31 above but suitable for 120 ltr cap water cooler
All as per item No. 31 above but suitable for 150 ltr cap, water cooler
Supply and fix in replacement of Relay suitable for water cooler of any capacity all as directed
Supply and fix in replacement running capacitor cap 15 Mfd suitable for water cooler of any capacity all as directed
Supply and fix in replacement starting capacitor cap 25 Mfd suitable for water cooler of any capacity all as directed
Supply and fix in replacement thermostate switch suitable for water cooler of capacity all as directed.
Supply and fix in replacement OLP suitable for water cooler of any capacity all as directed.
Supply and fix in replacement fan motor suitable for water cooler any capacity all as directed.
Supply and fix drain tray (stainless Steel) for water cooler of any capacity all as specifed and directed.
Material and Labour for tinkering and painting of rusted and damaged body and leg for water cooler complete all as specifed and directed.
Dismantling the voltage stabilizer of any make of 5KVA capacity and transporting to workshop carryout repair/replace defective parts and reassembling commissioning at site and testing complete all specifed and directed.Note : (i) Rate deemed to include minor spare parts (ii) Major spare parts shall be measured under relevant items.
All as per item no 42 above but 4KVA
All as per item no 42 above but 3KVA
Supply only relay suitable for 5KVA stabilizer
Supply only relay suitable for 4KVA stabilizer
Supply only relay suitable for 3KVA stabilizer
Supply only PCB board suitable for 5KVA stabilizer
Supply only PCB board suitable for 4KVA stabilizer
Supply only PCB board suitable for 3KVA stabilizer
M&L for Rewinding of transformer with super enameled copper conductor suitable for 5KVA stabilizer complete all as specifed and directed.
M&L for Rewinding of transformer with super enameled copper conductor suitable for 4KVA stabilizer complete all as specifed and directed.
M&L for Rewinding of transformer with super enameled copper conductor suitable for 3KVA stabilizer complete all as specifed and directed.
Supply and fix in replacement PVC cable 3 core PVC insulated 4Sqmm copper conductor 1100V all as specified and directed .
Supply and fix in replacement MCB SP 16 to 32 Amps 230Volt all as specifed and directed.
Supply and fix in replacement of AC remort controller unit incl fixing remote holder suitable for split ac model as specifed and directed.
M&L for refrigerant gas, (R410) suitable for cooling equipments supplied and filled etc complete all as specified and directed.
M&L for refrigerant gas,(R22) suitable for cooling equipments supplied and filled etc complete all as specified and directed.
M&L for refrigerant gas, (R134A) suitable for cooling equipments supplied and filled etc complete all as specified and directed.
S&F in replacement of outdoor unit sunction/discharge control valve brass complete all as specifed and directed
S & F in replacement copper tube, 15mm / 18 mm dia, superior quality suitable for refrigeration and suction lines of split ACs, drawn trough pipes/ fixed to walls/ laid on floor or roof etc complete all as specified and directed.
S&F in replacement copper tube, 9 mm dia, superior quality suitable for refrigeration and discharge lines of split ACs, drawn trough pipes/ fixed to walls/ laid on floor or roof etc complete all as specified and directed.
S & F inreplacement top plug 3 pin 5A bakelite etc complete all as specified and directed.
Supply and fix in replacement of chromium coated brass bip Tap for water cooler 15mm size all as specifed and directed.
M &L for point wiring with 4 Sqmm size PVC insulated unsheathed single core multistranded copper conductor cable ISI marked for working voltage 1100 volts grade, drawn in to and including PVC casing & caping with accessories controlled by one switch including 4 sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to earth dolly and to be terminated and including taking down the old wiring complete all as specified and as directed.
Supply & fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A , 240V including taking down the old enclosure complete all as specifed and directed.
Supply and fix in replacement of 15 mm float valve for water cooler all as specifed and directed.
M&L for writing letters/number in thick paint n. exc. 30 cm high Indoor/outdoor /water cooler as per format all as specifed and directed.
BKR Enterprises
KRISHNA ENTERPRISES
SAMYDOSS CONSTRUCTIONS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .