Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical HOLDING NO 389 WARD NO 26 BOMBAY HOTEL BUILDING JUNUSPATNA JOBRA ROAD COLLEGE SQUARE CUTTACK 753003 ODISHA | CUTTACK | CUTTACK | ODISHA | 753003 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 5 | Admitted-Fee/PreQual/Technical 24 PARAGANAS NORTH BELGERIA KOLKATA 700056 WEST BENGAL KOLKATA WEST BENGAL 700056 | 24 PARAGANAS NORTH | WEST BENGAL | 700056 | Admitted-Fee/PreQual/Technical |
Tender Value
₹47.0 Cr
EMD Value
₹94.0 L
Closing Date
20 Jan 2026, 11:00 amClosed
PU Head, Bhubaneswar
RITES Limited, Bhubaneswar
Supply, Installation, Testing Commissioning of Electronic Interlocking System along with all the outdoor gears, cables etc. for alteration in existing Electronic Interlocking arrangement at BOCM CABIN3 CABIN4 Railway yards Make SIEMENS and Ne
2025_RITES_260967_1
RITES/BBSR/Lakhanpur/SnT/OT_09
Open Tender
Information Technology
Percentage
365 days
MCL Lakhanpur
please check the uploaded tender document
4 documents required · 4 mandatory
₹21,240
Payable To RITES Limited
₹94.0 L
13 Feb 2026
30 Dec 2025
21 Jan 2026
30 Dec 2025
20 Jan 2026
13 Jan 2026
Amount after unconditional Rebate
Item Rate BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
S & T WORK
BoQ3 SCHEDULE - A1 (EI Execution Schedule)
BoQ4 SCHEDULE - A2 (Indoor & Outdoor Execution Schedule)
BoQ5 SCHEDULE - B1 (EI Supply Schedule)
BoQ6 SCHEDULE - B2 (Supply Schedule)
BoQ7 SCHEDULE - C (Drawing & Design)
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE - A1 (EI Execution Schedule) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bid is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
NOTE:- 1) Installation & commissioning of Electronic Interlocking is as per technical specification. 2) If it is phase working, other than initial phase design, supply of application logic required for phase working should be done by the Contractor agianst this item. 3) The work includes manufacture/ fabrication, supply and installation of SM's console and side table extension as per site requirement and as advised by site Engineer to accomodate VDUs, other S&T equipments and SM's stationary for operation of VDUs and execution of day to day work for operation of trains.
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE - A2 (Indoor & Outdoor Execution Schedule) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bid is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Fixing of route Indicator/Shunt LED in units, LED type lamp unit with current regulator in illuminated marker/route indicator unit. This includes taking the cable inside the unit, fixing of current regulator etc., complete wiring, fitting of terminals, LED signal lamps, and dismantling of existing lamps and fittings as required. The painting and lettering of existing markers and numbering plate to be done by enamel paint. All materials including PVC wires, blanking stretcher, PVC flexible pipe, hylum strip (6 mm thick), terminals and all sundry materials are to be supplied by the contractor. MCL will supply LED Units.
Transportation, excavation of pit, casting of foundation, plastering and erection of Steel Apparatus case (full size) with fixing of E-Type lock, wiring, cable entry, termination clamping, filling cable pit with sand, painting and lettering etc., as per Drg.No. S&T/CON/SK/16. This includes earth work and/or masonry work required for securing the apparatus case as per site condition. MCL will supply apparatus case with 'E' type lock only. Tenderer will supply all wiring materials, PBT Terminals, fuses, fuse blocks, bus bars, hylum sheet ISI mark [6mm thickness], wood plank board of good quality [minimum 3/4" thick], Cement and transport all the materials to site of work at his own cost. The wiring materials such as wire coils, PBT terminals, fuses, fuse block, etc. should be used from RDSO approved sources. 1) Modifiaction of inside arrangement of Apparatus cases if required for fixing of relays/transformers etc. shall be done by the contractor. Extra shelf, if any, shall be deposited to the MCL stores by the contractor. 2) All cables shall be terminated by providing copper eyelet of suitable size.
Transportation, excavation of pit, casting of foundation, plastering and erection of Steel Apparatus case (Half size) with fixing of E-Type lock, wiring, cable entry, termination clamping, filling cable pit with sand, painting and lettering etc., as per Drg.No. S&T/Con/BBS/92/90. This includes earth work and/or masonry work required for securing the apparatus case as per site condition. MCL will supply apparatus case with 'E' type lock only. Tenderer shall supply all wiring materials, PBT Terminals, fuses, fuse blocks, bus bars, hylum sheet ISI mark [6mm thickness], wood plank board of good quality [minimum 3/4" thick], cement and any other materials that are required for the work at his own cost. Contractor has to transport all the materials from store at his own cost to the work site. The wiring materials such as wire coils, PBT terminals, fuses, fuse block, etc. should be used from RDSO approved sources. 1) Modifiaction of inside arrangement of Apparatus cases if required for fixing of relays/transformers etc. shall be done by the contractor. Extra shelf, if any, shall be deposited to the MCL stores by the contractor. 2) All cables shall be terminated by providing copper eyelet of suitable size.
Supply, transportation and fixing of MS ladder with suitable clamping arrangement & associated masonary and smithy work in Relay room, equipment room, Battery room, Goomties and cabins etc. The MS ladder should be made of 1" X 1" (1/8"/3 mm thickness) and MS flat size of 1" wide X 1/8" / 3 mm thickness. MS flat shall be provided at every 8"apart. Width of ladder shall be 8". Tenderer shall supply all materials for this work. Inspection By representative of MCL before use. [RM=Running Meter]
[i] 1.2 Meter
[ii] 1.0 Meter
[iii] 0.8 Meter
Supply and Fixing of cable route marker as per drawing in technical specification at a distance of 100 mtrs. Along the trench and at places where the cable route has taken diversion as per instruction of site Engineer, this includes casting of foundation at site and fixing of the marker in the foundation made earlier at site as per railway directives and specifications (SDO/Cable laying/020 dt.31.10.2011), this includes proper curing of the structure, All materials required including marker for this like cement, sand 15 mm chips and steel rod of ISI marks should be supplied by the tenderer. Cable Route Marker will be Inspection by the Representative of MCL
Excavation of trenches in all kinds of soils including soft rocky area and clearing of track etc. to a depth of 1.0 M and width of 0.3 M for track crossing /pucca road/level crossing gate/platform/station circulating area or any other place as advised by site Engineer including transportation and laying of DWC/RCC/Split RCC/G.I. pipes with or without coupler. This includes repairing of track/pucca road/level crossing gate/ platform/station circulating area surface to original position by ramming and concreting wherever required soon after the work is over. DWC/RCC/GI pipes shall be supplied by the MCL. DWC pipes wherever required shall be supplied in 6 Mtr. length and shall be cut to size as per requirement. All other materials including cement are to be supplied by the contractor.
Excavation of trenches including clearing of roots of trees etc., in rocky area up to a depth to be indicated by MCL Engineer at site as per the site condition [Minimum 0.6 meter] and width 0.3 Mts. at the bottom. This includes concreting & plastering as per the instructions of site Engineer and complete back filling by digging earth from a lead of 30 Mtr. In case 0.8 meter depth or higher is achieved no concreting is required, otherwise concreting up to 100 mm thickness should be done. All materials required for the above works shall be supplied by the Contractor.
Laying of Signalling/4 Quad/ 6 Quad/ Power Cable/Telecom cables/ Jelly filled cables of all sizes in excavated trench, through GI/RCC/DWC pipes etc. wherever required. This includes transportation of cables from the stores to work site and transportation of empty cable drums with left over cables from site to the stores. The length of cable laid includes the length of cable coil for termination purpose. NOTE: The cables are to be carefully handled during loading, un-loading and transportation to work site. Any damage found in the cable after final testing, in view of mishandling of cables, shall be made good by the Tenderer. Cable should be maggered before and after laying and recorded in a register and submitted to the site Engineer.
Transportation, laying of all sizes of split double walled corrugated (DWC) pipes in the cable trench parallel to track or as advised by site engineer.
Trenching and fixing of G.I. pipes of different sizes/DWC pipes in hard rocky area up to a depth of 0.3 M to 0.6 M or at places as per instruction of site Engineer and concreting [1 : 3 : 6] up to height of 100 mm above the pipes. G.I. pipes with the socket/ DWC pipes shall be supplied by the MCL. All other materials required for the works shall be supplied by the contractor. Note: [1] In case of girder bridges, G.I. pipes shall be suitably clamped by the contractor as advised by the site Engineer. Clamps shall be supplied by the contractor. [2] The work including excavation of trenches in hard rock area up to a depth of 0.3 M to 0.6 M and back filling, ramming after completion of work where ever required. [3] In case of concrete bridges clearing of ballast for laying of pipes and re arranging the MCL ballast after completion of work shall be done by the contractor.
Surge Protection Device for 230 V AC input to PC, complete with enclosure and connected wire as per technical specification No:RS-SPD-5.
Surge protection Device for 110V AC input to signals complete with connected wire .
Surge protection Device for 110V DC input to IPS Goomty, complete with connected wire as per technical specificition No:RS-SPD-7.
Surge Protection Device for 24V DC supply complete with connected wire as per technical specification No: TS-SPD-3.
Surge Protection Device for 12V DC supply complete with connected wire as per technical specification No: TS-SPD-3.
Transportation, installation, testing and commissioning of Multi section digital axle counter (MSDAC) in complete system with all DPs of different track section configuration as per enclosed drawing. Axle counter device complete with standard accessories shall be supplied by the MCL. All sorts of terminals, sealed wires, condensers, resistances etc., HDPE pipes and all other materials required for the above work shall be supplied by the contractor. This includes design, installation, testing, commissioning of MSDAC evaluation arrangement with all necessary modules cards, interface cables, software and other materials etc., execution of associated work for working of axle counter through OFC/Quad cable. The tenderer shall ensure that axle countr installed by the OEM.
Track crossing by horizontal boring method as per technical specification given in Tender document.
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE - B1 (EI Supply Schedule) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bid is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Design, manufacture, supply and transportation of Electronic Interlocking System (Distributed/Centerlized Configuration System with hot stand by features) for Station complete as per the special conditions of contract & Technical Specifications. This includes supply of Computer Maintenance Console-1 No, Computer Operator Console-2 Nos, Surge Protection Devices, DC-DC Converters and FAT & SAT for the EI System. The Equipment shall confirm to RDSO/SPN/192/2019 Ver.2 or RDSO/SPN/203/2011 Ver.1 with latest amendments and as per enclosed technical specifications. Inspection by RDSO. NOTE 1:- This includes supply of Relay Rack and all interface relays for EI system. NOTE 2:-If required depending upon yard alteration, Additional cards/modules/sub-items and Essential spares shall be procured as per the variation clause incorporated in this tender document. The tenderer shall supply the spares as per the accepted rate of Items/Sub-items/Modules of item No-1 of Sch-B-I and as per same terms & conditions. NOTE 3: a) The successful bidder shall submit an undertaking from RDSO approved EI OEM before the supply of material to confirm compliance with extant RDSO guidelines and to meet contract specific requirements. b) MOU with the same RDSO approved source covering supply of the equipment of the EI, Installation,Testing & commisimnning of EI including after sales. support, required during the warranty period and beyond warranty period and before supply of equipment.
Supply of EI equipment for the routes up to 70 routes
Supply of EI equipment beyond 70 routes but upto 200 routes. [Rates of EI equipent upto 70 routes will be taken as per (a), & for additional routes will be taken as per (b).]
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE - B2 (Supply Schedule) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bid is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Supply of Steel Apparatus case 'large Size' as per Drg. No - CON/SK/1/1/86 and Spec.No. IRS:S-10/78 (adv) with latest amnd. with "E" type lock and key of ward No-32 with handle. Inspection by RITES.
Supply of Steel Apparatus case 'Half Size' as per Drg.No.S&T/CON/BBS/92/90 with 'E' type lock & Key. Ward No. 32. Inspection by RITES.
Supply of double walled corrugated pipe 6 mtr in length, 120 mm outer dia and 103 mm inner dia, with one suitable coupler conforming to RDSO Specification No. RDSO/SPN/204/2011 Version 1.1 Amdt 1 or latest for under ground cable protection . Colour-Orange. Inspection by RITES. Note: If required, the DWC pipe shall be supplied split in two halves.
Supply of Perforated G.I. pipe of 100 mm dia with socket. G.I. pipe of make TATA/JINDAL shall be as per IS: 1239 part-I/2004 Specification for medium gauge and shall be perforated by drilling 7 mm dia holes length wise in zig-zag manner staggered at a distance of 300 mm. Inspection by the Representative of MCL.
Supply of split double walled corrugated(DWC) pipes of HDPE confirming to IS:14930,Part-II(ISI marked on pipe)with IP:67 protection of size Minimum outer dia 250mm & minimum inner dia-217mm with out socket /coupler. The HDPE/DWC pipe should have anti-rodent properties and fire resistant TEC specification to GR/DWC/34/01.sept-07 with latest ammendment. Inspection by RITES.
Supply of Relay AC Immune, plug-in type, style 'QNA1', Neutral line, 24V DC 8F/8B contacts, Front and back contacts metal to carbon, complete with plug board, retaining clip and connectors conforming to BRS:931A,IRS: S-60, IRS: S-34, IRS: S-23 (As applicable). Interlocking code: ABDGH. Inspection by RDSO.
Supply of Relay Non-AC immune , plug in type, style QN1, neutral line, 24V or 50V DC 8F/8B contacts metal to carbon with plug board, retaining clip and connectors confirming to BRS: 930, IRS: S-34 and IRS: S-23 (As applicable). The interlocking code for this unit shall be ABCDF for 24V and ABDEF for 50V. Inspection by RDSO. NOTE:- Depending upon the EI System, the operating voltage of the relay may change. Accordingly the quantity of relays of different operating voltage needs to be approved by MCL on request of the OEM of EI System. The contractor shall supply the compatible relays at the same rate.
Supply of Relay plug-in type Point Contactor relay AC immune plug in type style QBCA1 DC based contactor ,24 V DC with 2 HF ,4B contacts ,Heavy duty metal to carbon front contacts and back contacts metal to carbon ,complete with plug board retaining clip and connectors confirming to BRS : 943 ,IRS S-34, and IRS S -23. Interlocking code for this unit shall be BCEJK. Inspection by RDSO.
Relay plug in type , Style AC-LED: ALL aspect, AC lamp proving Relay unit with in built current transformer type, slow release neutral line relay, 4F/4B contact , front and back contact metal to carbon shall be suitable for working in series with 110V AC, LED signal lamp rated at 15W conforming to RDSO Spec No- STS/E/Relay/AC lit LED/signal/09-2002, Amdt. 1, BRS:941A, IRS:S:34 & IRS:S:23 {as applicable}. The interlocking code for this unit shall be ABDHK. Inspection by RDSO.
Surge Protection Device for 230 V AC input to PC, complete with enclosure and connected wire as per technical specification No:RS-SPD-5.
Surge protection Device for 110V AC input to signals complete with connected wire as per technical specificition No:RS-SPD-7 .
Surge protection Device for 110V DC input to IPS Goomty, complete with connected wire as per technical specificition No:RS-SPD-7.
Surge Protection Device for 24V DC supply complete with connected wire as per technical specification No: TS-SPD-3.
Surge Protection Device for 12V DC supply complete with connected wire as per technical specification No: TS-SPD-3.
Design, Manufacture, Supply of High Frequency Digital Axle Counter Multi-Section type complete system including central evaluator(s), final track clearance relay for each track section, reset boxes, LV boxes, detection points, mushroom housing for the trackside electronics and all other accessories fully wired to the ultimate capacity and fully equipped for all DPs/Nos of detection points (incuding interconnection cards to make common DP or dual DP) this as per RDSO/SPN/176/2013 version 3.0 or latest. conforming to existing yard. Inspection by RDSO. (This includes earthing of track device if required).
For Red Aspect
For Yellow Aspect
LED signal lighting unit for shunt signal with polycarbonate lens conforming to Indian Raiwlay chromatically standards and Specn. No. RDSO/SPN/153/2004 REV.-3 with latest amendment (This includes fuses and other accessories required for fixing). Inspection by RDSO.
6 core X 1.5 sq. mm.
12 core X 1.5 sq. mm.
24 core X 1.5 sq. mm.
Underground jelly Filled 6 Quad Cable for Signalling & Telecom Installations Confirming to IRS: TC-30/2005 (Ver. 1) with latest amendment having 0.9mm dia Copper Conductor. Inspection by RDSO
Supply of MS flat of size 40mm x 6mm at site which includes loading, unloading, transportation and fixing. Inspection by representative of Railway.
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE - C (Drawing & Design) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bid is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
For a Eight-Line Station or more
Route Control Charts (RCC)
Logic Circuits
Interface Circuits
stage.html
html • 0.03 MB
cancelled_1.pdf
pdf • 0.24 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
tenderdoc_merged.pdf
Tender Documents • 5.64 MB
BOQ_301968.xls
BOQ • 0.75 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .