Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 and Most reasonable | |
| 2 | L2₹9.9 L+₹3,915.21 (0.40%)Rejected-Finance | L2 | Rejected-Finance Being Not L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Documents are not in Order |
Tender Value
Refer Docs
EMD Value
₹19,980
Closing Date
10 Aug 2022, 6:00 pmClosed
AGE(I) DALHOUSIE
AGE(I) DALHOUSIE PIN-176305
CERTAIN MAINT WORK TO REFRIGERATOR AC COOLING APPLIANCES AND REPAIR PAINTING OF ROOF SHEET AT DALHOUSIE AND BAKHLOH CANTT
2022_MES_537414_1
8880/2022-23/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE(I) DALHOUSIE
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE(I) DALHOUSIE
₹19,980
Yes
AGE(I) DALHOUSIE
26 Nov 2022
12 Jul 2022
12 Aug 2022
12 Jul 2022
10 Aug 2022
27 Jul 2022
12 Jul 2022 - 22 Jul 2022
22 Jul 2022
Amount
M&L for general servicing / repairs / maintenance by authorised dealer/ represntative of cold storage unit by leak testing with N- 2 gas under constant pressure of 250 PSI after complete transfer of refrigerant gas from the entire system, rectification of leakage by cutting and brazing the refrigeration system wherever required. Replacement of 'O' Ring tefflonwasher of valves copper tubing, safety valves, flare nuts etc. Neutralising after the pressure hold good for atleast 24 hours vaccumisation, charging the system with refrigerant gas including complete testing at site all as specified and directed. Note:- Gas charging including in the quoted rate and no extra payment to be made.
M&L for general servicing / repairs / maintenance by authorised dealer/ represntative of cold storage unit by tightening / rectification of electric circuit of all units and controll wiring , phase seqquence, including replacement of fused indication lamp, cleaning of all power contacts, rectification of minor defects complete testing at site all as specified and directed.
M&L for general servicing/ repair and maintenance of window type AC's of capacity 1.5/2.0 TR comprising of the following tasks at different location of any condition & and transporting to contractor workshop to carry out necessary repair including refixing at site, commissioning, testing, painting of AC's and writing of MES Number complete all as specified and directed :- (i) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. (ii) Carry out running test of operation of blower and compressor and ensure that satisfactory functioning of all parts. (iii) Inspecting for leakage in the system. (iv) Checking the earth continuity of electrical parts. (v) Checking the functioning of thermostat. (vi) Inspection of electrical parts. (vii) Testing the machine for satisfactory operation. Note:- (i) Any part found unserviceable / defective shall be measured and paid separately under respective item here-in-after. (ii) Make of parts shall be as per original window type AC.
S&F in replacement of air filter of window type AC 1.5/2.0 TR capacity asper existing Make & Model as required at site complete all as specified and directed. Make: - Coir foam or equivalent make ISI marked.
S& F in replacement of cooling coil as per existing Make and Model suitable for 1.5/2.0 TR capacity window air conditioner commissioning & testing complete all as specified and directed.
S&F in replacement of fan & blower motor as per existing make & model & suitable for 1.5/2.0 TR capacity window air conditioner complete all as specfied and directed.
S&F in replacement of fan blade as per existing make & model & suitable for 1.5/2.0 TR capacity window air conditioner complete all as specified and directed
M&L for charging of Refrigerant (R-22) to 1.5/2.0 TR Air conditioner up to maintain reqd temperature as per site condition complete all as specified and directed. Note :- (i) Refrigernat (R-22) shall be deemed to be included in the quoted rate. (ii) Empty / filled cylinder shall be responsibility of contractor and he shall be liable for all risk against same deemed to be including in the quoted rate.
S&F in repair compressor Hermatically sealed unit suitable for 1.5/2.0 TR AC window type ISI marked suitable for working on 230 volts single phase including filling of gas R-22 of required quantity including testing on full load complete all as specified and as directed. make- Emerson copland or equivalent approved make.
S& F in replacement of Running capacitor 36/45 MFD. Make: Usha/ Caital/ Epcos or equivalent complete all as specified and directed.
S& F in replacement of Starting capacitor 80/100 MFD. Make: Usha/ Caital/ Epcos or equivalent complete all as specified and directed.
S&F in replacement of Electronic circuit board for window type air conditioners suitable for 1.5 Ton AC window type ISI marked as per the existing make complete all as specified and directed..
S&F in replacement of Gas filter for 1.5/2.0 Ton AC make: Vijay /Goldstar
S&F in replacement of Thermostat switch for 1.5/2.0 Ton AC make: Renutrol/Indfoss complete all as specified and directed.
S&F in replacement of Front grill suitable size Make: Gem/Usha/Fedferlloyed/ Carrier air conditioner.
M&L for general servicing/repair & maintenace of Refrigerator 165 to 320 Ltr capacity comprising of the following tasks at different location and disconnecting and taking out unserviceable parts such as relay over load, thermostat, gas filter, bulb etc including fixing new parts with new nut bolts and washers etc re-assembling the refrigerator after repairing and testing complete including welding / Brazing works where ever required complete all as specified and as directed including and transporting to contractor workshop to carry out necessary repair complete all as specified and directed :- (i) Inspecting, taking down, brushing cleaning with blower including acid/ detergent wash of condenser and cooling coil. (ii) Carry out operation of blower and compressor and ensure that satisfactory funtioning of all parts. (iii) Inspecting the leakage in the system. (iv) Checking of the earth continuity of electrical parts. (v) Checking the functioning of thermostat (vi) Inspection of all electrical parts (vii) Testing the machine for satisfactory operation. (viii) Check and correct all electrical wiring & test its functioning. (ix) Testing of Refrigerator after repair. Note:- (i) Any parts found unservicable/defective shall be measured and paid separately under respectivel item here-in-after. (ii) Make of parts shall be as per original Refrigerator.
Supply and fixing in replacemrn of old unserviceable spare parts of Refrigeratator for capacity 180 ltr to 310 ltr and fixing new spare partrs with complete testing after completion of work complete suitable for make (Whirlpool/ classic/Godraj/LG) and list of items are as under:-
PTC relay OLP HE 48/115 (Make: Whirlpool / Classic / Godrej / LG)
Door handle suitable for 165 - 310 Ltrs capacity refrigerators.
Overload protector for refrigerator 1/6 HP (Make: Whirlpool / Classic / Godrej / LG)
Overload protector for refrigerator 1/8 HP (Make: Whirlpool / Classic / Godrej / LG)
Thermostat suitable for 165-30 Ltr refrigerator (Make: Ranutrol /Indfoss)
Vibration Pad for AC Compresssor of Refrigerator any capacity
Water west tray for Refrigerator suitable for 310 Ltr capacity
Section pipe insulator for Refrigerator suitable for 310 Ltr capacity
Stand Shoe for Refrigerator
Freezer Door frame for Refrigerator suitable for 310 Ltr capacity
Bulb holder for Refrigerator
Bulb Cover for Refrigerator suitable for 310 Ltr capacity
Vegitable Tray glass for Refrigerator suitable for 310 Ltr capacity
Vegitable Tray glass for Refrigerator suitable for 180/190 Ltr capacity
Freezer Hings
Healing Condenser for Refrigerator suitable for 310 Ltr capacity
Base Plate for Refrigerator suitable for 310 Ltr capacity
Door lock for Refrigerator 310/190 Ltr capacity
Door switch for Refrigerator 310/190 Ltr capacity
Heating condeser for Refrigerator 190 Ltr capacity
Compressor guard plate for Refrigerator suitable for 310 Ltr capacity
Freezer door Frame for Refrigerator suitable for 180/190 Ltr capacity
S&F in replacement of burnt compressor Company make original as per existing Make & model & suitable for refrigerator of capacity 165-190 Ltr complete all as specified and directed . Gas charging will be measured and paid saparately.
S&F in replacement of burnt compressor Company make original as per existing Make & model & suitable for refrigerator of capacity 215-310 Ltr complete all as specified and directed . Gas charging will be measured and paid saparately.
Disconnecting and taking down refrigerator (165 to 320 Ltr Cap) of any make and size for repairs & including detecting of leakage in the system rectifying the same, dehydration & recharging of gas (R-134a) & testing the refrigerator for smooth & satisfactory operation complete all as specified and directed .NOTE:- (i) Filling / recharging of gas (R-134a) shall be deemed to be included in the quoted rate (ii) Empty / filled cylinder shall be responsibility of contractor and he shall be liable for all risk against same deemed to be included in the quoted rate.
S&F in repair ice chamber (Freezer) for 165 / 175 /285 /300 /315 Ltr refrigerator surrounded by frezzer pipes complete all as specified and as directed . Make : Whirlpool / Kelvinator / Godrej /LG
Supply and fixing in replacement of cooling coil for 285 / 300 / 310 Ltr of any make refrigerator. Make: Whirlpool / Godrej/LG
Supply and fixing in replacement of cooling coil for 165/175 Ltrs of any make refrigeratror. Make: Whirlpool/Godrej/LG
Supply & fixing in replacement of single phase, wall mounted copper wound, air cooled type with digital display of output voltage 220V ± 9% and calibration accuracy ± 3% Voltage stablizer 5 KVA, range of 170-260V all as specified and directed by Engr-in-Charge. Make:- Volina / V Guard / Aplab
M&L for opening of the stablizer/A/C protectors, removing of the all internal parts, replaceing of the unserviceable PCB, rewidning of T/F replacement of indicating lamp, volt meter fuse cutout, relay reocnnecting back and testing complete of the following size all as specified and directed.
(a) 0.5 KVA capacity
(b) 1 KVA capacity
(e) 5 KVA capacity
M&L for general servicing/repair & maintenace by authroised dealer/ representative of Deep Freezer 300 to 320 Ltr capacity comprising of the following tasks at different location and disconnecting and taking out unserviceable parts such as relay over load, thermostat, gas filter, bulb etc. including fixing new parts with new parts with new nut bolt and washers etc reassembling the Deep Frezzer after repairing and testing complete including welding / Brezing works where ever required complete all as specified and as directed including and transporting to contractor workshop to carry out necessary repair complete all as specified and directed. (i) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. (ii) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. (iii) Inspecting the leakage in the system (iv) check and correct all electrical parts. (vii) Testing the machine for satisfactory operation. (viii) Check and correct all electrical wiring & test its functioning (ix) Testign of Refrigerator after repair. Note:- (i) Any parts found unserviceable/defective shall be measured and paid separately under respectivel item here-in-after. (ii) Make of parts shall be as per original Deep Freezer.
S&F in repair compressor Hermatically sealed unit suitable for 320 Ltr deep freezer of existing make suitable for working on 230 volts single phase with filling of gas R-22 of required quantity including testing on full load complete all as specified and directed.
Supply and replacing old u/s cable and fixing of PVC cooper cable 4 sqmm 3 core for all connection with stablizer, refrigerator, deep freeaers all as specified and directed by Engineer-in-Charge.
S&F sheet metal enclosure with single pole and neutral enclosure with 2 pin and earth plug and socket complete with one single pole MCB of capaicty, 20 Amps 230 Volts including removing of the old U/S all as directed Make:- Stanard.
S&F plug top 3 pin 5 Amps 230 Volts including removing of the old U/S all as directed.
All as per item No.30 above but 15 Amps
M&L for writing SM No. MES No. etc. on Refrigerator, Deep freezer & AC at site approved shade/color of synthetic enamel paint , hight of letter 20/40 mm and up to 20 Nos in words/Figures complete all as specified and directed
M&L for servicing of waterpurification system with replacement of choked filter, memberan, pvc pipe, UV protection memberan with complete cleaning and proper testing of water after complete replacement of all unserviceable items inside the waterpruification system for capacity of 8 Ltr to 14 Ltr for make of Kent/ Aquaguard or equivalent other make all as specified and directed by Engineer-in-Charge
M&L for servicing of water Dispenser system with replacement of water guard, up middle plate, switch plate, hot thermostat, drier filter, hot taps, drain box with fillign of refregent ges R-134a with complete testing of Cold and Hot water system and proper testing of all electrical wiring after complete replacement of all unserviceable items inside the Water Dispenser system for capacity of 20 Ltr for make of VOLTAS or equivalent other make all as specified and directed by Engineer-in-Charge
Supplying, fixing, jointing, connecting & testing in trenches XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts /on wall surface as in repairs/replacement of old unserviceable cable of following sizes all as specified and directed.
(a) 2 core 16 Sqmm
(b) 4 core 16 Sqmm
M&L for sand cushioning for cable protection 8 cm below the cable and 15 cm above the cable complete all as specified and directed
Supply and lay burnt bricks sub class `B’ of size 230x115x75mm laid dry over sand cushioning in trenches as protection on the cable all as directed
Excavation in trenches in any type of soil n. exc 1.5mtr wide and n. exc 1.5mtr depth for GI tubing and getting out in Hard/dense soil all as specified.
M&L for returning, filling in including sperading, leveling watering and well ramming in layers n. exc 25 cm thick each layers in soil all as specified and directed.
M&L for removal of surplus soil to a distance not exceeding 50 mtr and deposting where directed and at a level not exceeding 1.5 mtr above the starting point all as specified and directed by Engr-in-Charge.
Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick burried directly in ground any type of soil including rock soil alos (earth pit not less than 2.25 Mtr below ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised iron lead wire 4.0 mm as earthing lead by means of bolts, nuts, check nuts, as earth lead complete including 40mm bore dia protection pipe GI medium grade upto 7.5 mtr length, watering pipe 15mm bore dia GI medium grade 1.70m length, charcoal & salt filling, necessary earth work in any type of soil including rocky soil also, concrete pit, funnel removal of surplus soil upto 50m distance all as per electrical plate No.3 of SSR Part-I and connected to earthing test point, main board including testing on completion all as specified and as directed by Engr-in-charge.
Dismantling plain or corrugated steel sheeting any gauge, thickness, including naintal or similar pattern roof coverings.
S&F Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with L-type or J-type or cranked hook bolts, in roofs, walls etc. with grade of zinc coating 275 all complete as specified and directed.
S&F 0.8mm thick plain, galvanised, mild steel sheeting in ridges, hips, valley gutters, drip & straight flashins (length and girth as fixed) having zinc coating @ 120 gm/sqm fixed with 'L' type or 'J' type or cranked hook bolt complete as directed.
Ditto as per srl item 43 and 44 but Except sheeting (any Thickness) and all as specified and as directed
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. (Make TATA or JSW)
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Preparation of old painted steel surfaces (such as CGI sheet, Window grill ,GI water tube, fencing post etc.) and applying two coat of synthetic enamel paint complete all as specified
Preparation of new steel surfaces (such as CGI sheet, Window grill ,GI water tube, fencing post etc.) and applying two coat of synthetic enamel paint complete all as specified
Dismantling timber scantling 40sqcm and over in section in any position in framed work all as specified.
M&L for second class hardwood in scantlings in framed work and fixed clean sawn etc all as specified.
M/S ONKAR SINGH PATHANIA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .